Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Clin Exp Allergy ; 54(4): 241-252, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38332535

RESUMEN

Atopic dermatitis (AD) is a chronic inflammatory skin disease for which new targeted therapies are currently available. Due to the increased rates of ocular surface disease (OSD) reported during treatment with these new targeted treatments, more insight into the occurrence and pathomechanism of OSD in moderate-to-severe AD patients is needed. Therefore, this review's first part highlights that most patients with moderate-to-severe AD already have characteristics of OSD before starting targeted treatment. Remarkably, not all AD patients with OSD report ocular symptoms. OSD in AD is associated with less conjunctival goblet cells (GC) compared to healthy controls. In addition, OSD severity in AD patients is associated with high AD activity, the presence of eyelid and/or facial eczema, and high levels of AD-related severity biomarkers in tear fluid. The second part of this review highlights that pre-existing ocular pathology (e.g. in combination with the use of ophthalmic medication or eyelid eczema) may be associated with the development of dupilumab-associated ocular surface disease (DAOSD). During dupilumab treatment, DAOSD (which can be new-onset OSD or worsening of pre-existing OSD) is observed in approximately one-third of the dupilumab-treated AD patients. Anti-inflammatory ophthalmic treatment improves DAOSD, and dose reduction of dupilumab may also be an effective treatment option. The pathomechanism of DAOSD is still not fully elucidated. In a prospective study low, but stable conjunctival GC numbers were observed in moderate-to-severe AD patients, before and during dupilumab treatment. However, the Mucin 5 AC (MUC5AC) expression of GCs decreased during dupilumab treatment, suggesting an impairment of the GC function by dupilumab treatment. In addition, higher dupilumab tear fluid levels were found in dupilumab-treated AD patients with moderate-to-severe OSD compared to patients with no or mild OSD, whereas the dupilumab serum levels are similar. Clinicians should be aware of the frequent occurrence of OSD in moderate-to-severe AD patients, and a low-threshold referral to an ophthalmologist is recommended.


Asunto(s)
Dermatitis Atópica , Eccema , Humanos , Anticuerpos Monoclonales/uso terapéutico , Estudios Prospectivos , Resultado del Tratamiento , Terapia Biológica , Índice de Severidad de la Enfermedad
2.
J Thromb Haemost ; 21(12): 3490-3500, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37741510

RESUMEN

BACKGROUND: Accurate measurement of emicizumab in the presence of factor (F) VIII is required in patients with severe hemophilia A treated with emicizumab, as well as additional need for FVIII substitution or emicizumab prophylaxis in patients with acquired or moderate to mild hemophilia A. However, the presence of FVIII potentially biases the results. OBJECTIVES: To assess the impact of plasma FVIII activity on determined emicizumab levels and evaluate different strategies for correction for or preanalytical inhibition of FVIII. METHODS: Evaluated strategies comprised of the following: (1) calculation of actual emicizumab plasma levels based on measured FVIII activities and FVIII-affected emicizumab values, (2) preanalytical heat treatment (56 °C for 40 minutes), and (3) neutralization of FVIII activity using FVIII inhibitors. Emicizumab levels and FVIII activities were measured using a modified FVIII one-stage clotting assay and a chromogenic FVIII assay based on bovine factors, respectively. RESULTS: Spiking experiments revealed a consistent linear association between FVIII activities and determined (FVIII-affected) emicizumab results at different emicizumab input levels (∼0.12 µg/mL per IU/dL of FVIII). This principally allowed for mathematical correction of measured emicizumab levels in the presence of FVIII. While a 40% to 50% activity loss of intrinsic plasma emicizumab through heat treatment was observed in patient samples, emicizumab spiked into FVIII-deficient plasma was not or only marginally affected. Application of inhibitor-based FVIII neutralization led to good agreement of results when compared with direct quantification of emicizumab by liquid chromatography-tandem mass spectrometry. CONCLUSION: Inhibitor-based FVIII neutralization appears to be a feasible strategy for accurate measurement of plasma emicizumab levels in the presence of FVIII activity.


Asunto(s)
Anticuerpos Biespecíficos , Hemofilia A , Hemostáticos , Humanos , Animales , Bovinos , Factor VIII/uso terapéutico , Hemofilia A/diagnóstico , Hemofilia A/tratamiento farmacológico , Tiempo de Tromboplastina Parcial , Anticuerpos Biespecíficos/farmacología , Anticuerpos Biespecíficos/uso terapéutico , Hemostáticos/uso terapéutico
3.
Pharmaceutics ; 15(5)2023 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-37242719

RESUMEN

Monoclonal antibodies (mAbs), such as infliximab, are important treatment options for different diseases. Immunogenicity is a major risk, resulting in anti-drug antibodies (ADAs), being associated with adverse events and loss of response, influencing long-term outcomes. The development of ADAs against infliximab is primarily measured by immunoassays like radioimmunoassay (RIA). Although liquid chromatography-tandem mass spectrometry (LC-MS/MS) is increasingly utilized across different fields, this technique is currently not used for ADAs against infliximab measurements. Therefore, we developed the first LC-MS/MS method. Stable isotopically labeled infliximab antigen-binding fragments (SIL IFX F(ab')2) were used to bind and measure ADAs indirectly. Protein A magnetic beads were used to capture IgG, including ADAs, whereafter SIL IFX F(ab')2 was added for labeling. After washing, internal standard addition, elution, denaturation and digestion samples were measured by LC-MS/MS. Internal validation showed good linearity between 0.1 and 16 mg/L (R2 > 0.998). Sixty samples were used for cross-validation with RIA, and no significant difference between ADA concentrations was found. The methods had high correlation (R = 0.94, p < 0.001) and excellent agreement, intraclass correlation coefficient = 0.912 (95% confidence interval 0.858-0.947, p < 0.001). We present the first ADA against the infliximab LC-MS/MS method. The method is amendable for quantifying other ADAs, making it applicable as a template for future ADA methods.

6.
Clin Transl Allergy ; 13(1): e12221, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36705509

RESUMEN

BACKGROUND: The patho-mechanism of ocular surface disease (OSD) in dupilumab-treated atopic dermatitis (AD) patients remains unclear. The aim of this study is to measure dupilumab levels in tear fluid and serum, and relate these findings to the severity of OSD during dupilumab treatment in AD patients. METHODS: This prospective study included dupilumab-treated moderate-to-severe AD patients who were seen by a dermatologist and an ophthalmologist before the start of dupilumab (baseline), and after 4 and 28 weeks of dupilumab treatment. Dupilumab levels in tear fluid and serum were measured by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Additionally, a pilot study was conducted to measure dupilumab on conjunctival epithelial cells using flow cytometry and LC-MS/MS. RESULTS: At baseline, 89.6% (n = 43/48) of the patients had OSD, with 50.0% having moderate-to-severe OSD. After 28 weeks of dupilumab treatment, the median dupilumab tear fluid levels were 0.55 mg/L (IQR 0.35-1.31) and 0.29 mg/L (IQR 0.16-0.60) in patients with moderate-to-severe OSD and patients with no or mild OSD, respectively (p = 0.02). Dupilumab levels could be detected on conjunctival epithelial cells of 5 AD patients treated with dupilumab for 4 weeks. CONCLUSION: Patients with moderate-to-severe OSD had higher dupilumab tear fluid levels compared to patients with no or mild OSD, indicating that dupilumab reaches the ocular surface. Dupilumab was also detected in conjunctival cell suspensions and was found to directly bind CD45-conjunctival epithelial cells. This suggests that AD-induced changes of the conjunctival epithelium may play a role in the development of OSD as well as increased local drug availability.

7.
Res Pract Thromb Haemost ; 6(4): e12725, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35702589

RESUMEN

Background: Emicizumab is a new treatment option for people with hemophilia A. Emicizumab was approved with a body-weight-based dosage regimen, without laboratory monitoring requirements. Guidelines, however, recommend measuring emicizumab concentrations when the presence of antidrug antibodies is suspected. Furthermore, drug monitoring can be useful in clinical decision making, in adherence checking, and for research purposes. Therefore, we developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying emicizumab. We performed a validation study on this LC-MS/MS method quantifying emicizumab in the plasma of people with hemophilia A. Methods: Sample preparation for LC-MS/MS analysis included ammonium sulfate protein precipitation and trypsin digestion. A signature peptide of emicizumab and a matching stable isotope-labeled internal standard were used to quantify emicizumab by LC-MS/MS analysis. Validation was performed in accordance with the "Guideline on Bioanalytical Method Validation" of the European Medicines Agency (EMA). The LC-MS/MS method was cross validated against a modified and calibrated (r 2 Diagnostics) one-stage clotting assay (OSA). Conclusions: The LC-MS/MS method demonstrated linearity over a wide range of emicizumab concentrations, far exceeding the concentrations observed in people with hemophilia A. Precision and accuracy were excellent, and all other validation parameters were also within the acceptance EMA criteria. Cross validation showed that the LC-MS/MS method and the OSA-based method can be used interchangeably for drug monitoring of emicizumab without the application of a correction factor.

8.
Pharmaceuticals (Basel) ; 14(7)2021 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-34206798

RESUMEN

(1) Background: Busulfan has been used as a conditioning regimen in allogeneic hematopoietic cell stem transplantation (HSCT). Owing to a large inter-individual variation in pharmacokinetics, therapeutic drug monitoring (TDM)-guided busulfan dosing is necessary to reduce graft failure and relapse rate. As there exists no TDM of busulfan administration for HCT in Taiwan, we conducted a pilot study to assess the TDM-dosing of busulfan in the Taiwanese population; (2) Methods: Seven patients with HCT from The Koo Foundation Sun Yat-Sen Cancer Center, Taipei, Taiwan, received conditioning regimens consisting of intravenous busulfan and other chemotherapies. After the initial busulfan dose, blood samples were collected for busulfan TDM at 5 min, 1 h, 2 h, and 3 h. Busulfan was extracted and detected by performing stable-isotope dilution LC-MS/MS. Plasma busulfan concentration was quantified and used for dose adjustment. Potential adverse effects of busulfan, such as mucositis and hepatic veno-occlusive disease (VOD), were also evaluated; (3) Results: The LC-MS/MS method was validated with an analyte recovery of 88-99%, within-run and between-run precision of <15%, and linearity ranging from 10 to 10,000 ng/mL. Using TDM-guided busulfan dosing, dose adjustment was necessary and performed in six out of seven patients (86%) with successful engraftments in all patients (100%). Mild mucositis was observed, and VOD was diagnosed in only one patient; (4) Conclusions: This single-center study in Taiwan demonstrated the importance of busulfan TDM in increasing the success rate of HCT transplantation. It is also necessary to further investigate the optimal busulfan target value in the Taiwanese population in the future.

9.
Rheumatology (Oxford) ; 61(1): 377-382, 2021 12 24.
Artículo en Inglés | MEDLINE | ID: mdl-33878159

RESUMEN

OBJECTIVE: The objective of this study was to assess the relationship between adalimumab trough concentrations and treatment response in paediatric patients with JIA. METHODS: This was a monocentric cohort study of JIA patients treated with adalimumab. Clinical data and samples were collected during routine follow-up. Adalimumab trough concentrations were quantified by a novel liquid chromatography-tandem mass spectrometry assay. Anti-adalimumab antibodies were measured in samples with trough concentrations of ≤5mg/l. Disease activity was evaluated using the clinical Juvenile Arthritis DAS with 71-joint count (cJADAS71). Response to adalimumab was defined according to recent international treat-to-target guidelines. RESULTS: A total of 35 adalimumab trough samples were available from 34 paediatric patients with JIA. Although there was no significant difference in adalimumab dose, trough concentrations were significantly lower in patients with secondary failure [median 1.0 mg/l; interquartile range (IQR) 1.0-5.3] compared with patients with primary failure (median 13.97 mg/l; IQR 11.81-16.67) or an adequate response (median 14.94 mg/l; IQR 10.31-16.19) to adalimumab. CONCLUSION: Adalimumab trough concentrations were significantly lower in JIA patients with secondary failure compared with patients with primary failure or an adequate response to adalimumab. Our results suggest that trough concentration measurements could identify JIA patients who require increased adalimumab doses to achieve or maintain therapeutic drug concentrations.


Asunto(s)
Adalimumab/uso terapéutico , Antirreumáticos/uso terapéutico , Artritis Juvenil/tratamiento farmacológico , Adalimumab/inmunología , Adalimumab/farmacocinética , Adolescente , Antirreumáticos/inmunología , Antirreumáticos/farmacocinética , Niño , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
10.
Int J Lab Hematol ; 42(6): 819-826, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32633067

RESUMEN

INTRODUCTION: Haemophilia A is a hereditary bleeding disorder caused by a factor VIII (FVIII) deficiency. As biomarker, FVIII activity is used to classify disease severity and to monitor treatment. The one-stage clotting assay (OSA) is performed to measure FVIII activity, but OSA's limitations may result in misclassification of disease severity or suboptimal monitoring of treatment. Measurement of FVIII plasma concentration with liquid chromatography-tandem mass spectrometry (LC-MS/MS) might overcome these challenges. The objective is to investigate the correlation between FVIII activity and concentration, and determinants for differences between the two methods. METHODS: In this cross-sectional study, all haemophilia A patients receiving standard-of-care were eligible for inclusion. Within the activity categories of <1 IU/dL, 1-5 IU/dL, >5-40 IU/dL, >40-150 IU/dL and >150-600 IU/dL, we randomly selected 15-20 plasma samples and compared FVIII concentration (LC-MS/MS) to FVIII activity (OSA) with linear regression and Bland-Altman analysis. Potential determinants for differences were analysed with linear regression. RESULTS: Inclusion was 87 samples. Bland-Altman analysis demonstrated an overall mean difference of -1% with an SD of 64% between the two methods. Large differences were correlated with the presence of anti-FVIII antibodies (133% [95% CI: 81, 185] n = 5) and use of exogenous FVIII products (-37% [95% CI: -65,-9] n = 58), for example plasma-derived and B-domain-modified FVIII products. CONCLUSIONS: Despite good overall correlation between the two methods, relative differences were large, especially for samples with anti-FVIII antibodies or exogenous FVIII products. These differences may have clinical impact. More research is needed to determine the value of FVIII plasma concentration in comparison with FVIII activity.


Asunto(s)
Factor VIII/metabolismo , Hemofilia A/sangre , Espectrometría de Masas en Tándem , Adulto , Biomarcadores/sangre , Pruebas de Coagulación Sanguínea , Estudios Transversales , Femenino , Humanos , Masculino , Prueba de Estudio Conceptual
11.
Ther Drug Monit ; 41(5): 640-647, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31584927

RESUMEN

BACKGROUND: Therapeutic drug monitoring of tumor necrosis factor alpha (TNF-α) inhibitors such as adalimumab (ADM) and infliximab (IFX) is considered of added value for patients with systemic inflammatory diseases. In contrast to enzyme-linked immunosorbent assay methods, liquid chromatography-tandem mass spectrometry methods allow for simultaneous quantification of multiple target antibodies in 1 run and thus providing a higher sample throughput. We describe a fast sample work-up strategy for the absolute and simultaneous quantification of ADM and IFX therapeutic monoclonal antibodies in human plasma samples using a target-specific sample purification in combination with liquid chromatography-tandem mass spectrometry. METHODS: The sample purification was based on the selective capture of ADM and IFX in human plasma or serum using biotinylated TNF-α (b-TNF-α), which was coated on a streptavidin 96-well plate. After elution, analytes were heat denatured and trypsin digested to obtain signature peptides for quantification. Stable isotopically labeled ADM and IFX were introduced as internal standard before sample purification. RESULTS: The method was successfully validated following current European medicines agency guidelines. The linear dynamic rage for both analytes were 1-32 mcg/mL with an excellent mean coefficient of determination, R = 0.9994 for ADM and 0.9996 for IFX. Within-run and between-run imprecision and accuracy were within acceptance criteria. Cross-validation against enzyme-linked immunosorbent assay method showed a high between-method correlation R = 0.962 for ADM and R = 0.982 for IFX. CONCLUSIONS: This method provides an easy, efficient, and cost-effective workflow for therapeutic drug monitoring patients treated with ADM or IFX.


Asunto(s)
Adalimumab/sangre , Infliximab/sangre , Plasma/química , Anticuerpos Monoclonales/sangre , Cromatografía Liquida/métodos , Monitoreo de Drogas/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Espectrometría de Masas en Tándem/métodos , Factor de Necrosis Tumoral alfa/antagonistas & inhibidores
12.
J Pharm Biomed Anal ; 175: 112781, 2019 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-31398627

RESUMEN

Patients with hemophilia A are currently diagnosed and monitored by measuring the activity of coagulation factor VIII (FVIII) in plasma mostly with the one-stage clotting assay (OSA). Although the OSA is routinely available in many clinical laboratories, it has in some circumstances relatively low sensitivity and specificity. Therefore, the FVIII activity as a biomarker does not always correlate with the bleeding phenotype. Therefore, we have developed a liquid chromatography tandem mass spectrometry method to quantify the concentration of coagulation FVIII in plasma which would allow us to investigate the relation between FVIII plasma concentration, FVIII activity and bleeding tendency in future studies. LC-MS/MS method was set up by firstly dissociation Von Willebrand factor (VWF) from coagulation factor VIII by triggering the coagulation cascade to occur thus generating active factor VIII (FVIIIa). FVIIIa was then selectively extracted by means of immunoaffinity interaction using anti-FVIII camelid nanobody, after which FVIIIa was eluted, heat denatured and trypsin digested. Finally, a FVIII specific peptide was used as a surrogate for quantification by mass spectrometry. Critical method parameters such as antibody amount, incubation time, sample volume and type of streptavidin 96 well plate were optimized. The method was validated according to European Medicines Agency (EMA) guidelines where an LLOQ of 1 ng/mL was obtained using 50 µL of citrate plasma sample. Within-run and between-run accuracy and precision for quality control (QC) samples, LLOQ (1 ng/mL), QC Low (5 ng/mL), QC Med (150 ng/mL), QC High (300 ng/mL) were within the threshold of 15% relative standard deviation (RSD) and Bias. The selective immunoaffinity method which was used in combination with a highly sensitive mass spectrometer allowed for an unpresented LLOQ of 1 ng/mL utilizing 50 µL plasma sample. This method will be used to investigate the beneficial value of FVIII plasma concentration which may be used in conjunction with FVIII activity for patient diagnosis and dosage optimization.


Asunto(s)
Anticuerpos/química , Camélidos del Nuevo Mundo/metabolismo , Factor VIII/química , Factor VIII/metabolismo , Plasma/química , Animales , Cromatografía Liquida/métodos , Hemofilia A/sangre , Humanos , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodos , Factor de von Willebrand/química
13.
Anal Chim Acta ; 1080: 22-34, 2019 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-31409472

RESUMEN

The promising pipeline of therapeutic monoclonal antibodies (mAbs) demands robust bioanalytical methods with swift development times for pharmacokinetic studies. Over the past decades ligand binding assays were the methods of choice for absolute quantification. However, the production of the required anti-idiotypic antibodies and ligands limits high-throughput method development for sensitive, accurate, and reproducible quantification of therapeutic mAbs. In recent years, high-resolution liquid chromatography tandem mass-spectrometry (LC-MS) systems have enabled absolute quantification of therapeutic mAbs with short method development times. These systems have additional benefits, such as a large linear dynamic range, a high specificity and the option of multiplexing. Here, we briefly discuss the current strategies for the quantification of therapeutic mAbs in biological matrices using LC-MS analysis based on top-down and middle-down quantitative proteomics. Then, we present the widely used bottom-up method in a six-step workflow, which can be used as guidance for quantitative LC-MS/MS method development of mAbs. Finally, strengths and weaknesses of the bottom-up method, which currently provides the most benefits, are discussed in detail.


Asunto(s)
Anticuerpos Monoclonales/sangre , Proteómica/métodos , Animales , Cromatografía Liquida/métodos , Humanos , Espectrometría de Masas en Tándem/métodos , Flujo de Trabajo
14.
J Transl Autoimmun ; 1: 100004, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32743494

RESUMEN

BACKGROUND: The development of anti-drug antibodies (ADA) in patients treated with therapeutic proteins can result in treatment failure. The clinically most relevant fraction of these antibodies are the neutralizing anti-drug antibodies (NAb) that block the pharmacological function of the drug. Consequently, the detection of NAb in plasma is a better predictor of loss of therapeutic response than increased levels of total anti-drug antibodies (ADA) test. Traditional assays to detect ADA and NAb have limited specificity, sensitivity and linear dynamic range. METHOD: Here, we demonstrate for the first time the potential of a LC-MS/MS method to measure the concentration of NAb against therapeutic proteins in plasma as exemplified with infliximab (IFX). We designed a competitive screening assay in which the presence of NAb in patients plasma prevents the binding of stable isotopically labeled (SIL) mAb infliximab to TNF-α ligand fixed on a 96-well plate. RESULTS: After washing, eluting and digesting, the signal intensity of SIL IFX-derived signature peptides was inversely and strongly correlated with NAb concentration in the sample: R2 â€‹= â€‹0.999. Evaluation data showed that the assay has a high specificity (100%) and a high sensitivity (94%) to predict NAb presence. Cross-validation against total ADA measured by a reference laboratory using radio immunoassay assay (RIA) for ADA provided a good correlation (r2 â€‹= â€‹0.79). CONCLUSION: We developed for the first time a robust and fast screening method on the basis of LC-MS/MS to determine the presence of NAb and its neutralizing capacity in plasma. The analyses of NAb can be combined with therapeutic mAb quantification. Furthermore, the quantification of the neutralizing capacity expressed as mAb mass equivalents opens the door to new personalized dosing strategies in patients with NAb.

15.
Anal Bioanal Chem ; 410(23): 5849-5858, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29938370

RESUMEN

Neuroblastoma is one of the most commonly found solid tumors in children. The monoclonal antibody dinutuximab (DNX) targets the sialic acid-containing glycosphingolipid GD2 expressed on almost all neuroblastoma tumor cells and induces cell lysis. However, the expression of GD2 is not limited to tumor cells only, but is also present on central nerve tissue and peripheral nerve cells explaining dinutuximab toxicity. The most common adverse reactions are pain and discomfort, which may lead to discontinuation of the treatment. Furthermore, there is little to no data available on exposure and effect relationships of dinutuximab. We, therefore, developed an easy method in order to quantify dinutuximab levels in human plasma. Ammonium sulfate (AS) was used to precipitate all immunoglobulins (IgGs) in human plasma. After centrifugation, supernatant containing albumin was decanted and the precipitated IgG fraction was re-dissolved in a buffer containing 0.5% sodium dodecyl sulfate (SDS). Samples were then reduced, alkylated, and digested with trypsin. Finally, a signature peptide in complementarity determining region 1 of DNX heavy chain was quantified on LC-MS/MS using a stable isotopically labeled peptide as internal standard. AS purification efficiently removed 97.5% of the albumin fraction in the supernatant layer. The validation performed on DNX showed that within-run and between-run coefficients of variation (CV) for lower limit of quantification (LLOQ) were 5.5 and 1.4%, respectively. The overall CVs for quality control (QC) low, QC med, and QC high levels were < 5%. Linearity in the range 1-32 mg/L was excellent (r2 > 0.999). Selectivity, stability, and matrix effect were in concordance with EMA guidelines. In conclusion, a method to quantify DNX in human plasma was successfully developed. In addition, the high and robust process efficiency enabled the utilization of a stable isotopically labeled (SIL) peptide instead of SIL DNX, which was commercially unavailable. Graphical abstract.


Asunto(s)
Anticuerpos Monoclonales/sangre , Antineoplásicos/sangre , Monitoreo de Drogas/métodos , Neuroblastoma/tratamiento farmacológico , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Anticuerpos Monoclonales/análisis , Antineoplásicos/análisis , Precipitación Química , Cromatografía Líquida de Alta Presión , Humanos , Límite de Detección , Neuroblastoma/sangre
17.
J Chromatogr A ; 1454: 42-8, 2016 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-27264745

RESUMEN

The therapeutic monoclonal antibody Infliximab (IFX) is a widely used drug for the treatment of several inflammatory autoimmune diseases. However, approximately 10% of patients develop anti-infliximab antibodies (ATIs) rendering the treatment ineffective. Early detection of underexposure to unbound IFX would result in a timely switch of therapy which could aid in the treatment of this disease. Streptavidin coated 96 well plates were used to capture biotinylated-tumor necrosis factor -alpha (b-TNF-α), which in turn was used to selectively extract the active form of IFX in human serum. After elution, IFX was digested using trypsin and one signature peptide was selected for subsequent analysis on liquid chromatography-tandem mass spectrometry (LC-MS/MS). The internal standard used was a stable isotopic labeled IFX bio-similar. The assay was successfully validated according to European Medicines Agency (EMA) guidelines and was found to be linear in a range of 0.5-20µg/mL (r(2)=0.994). Lower limit of quantification for the assay (<20% CV) was 0.5µg/mL, requiring only 2µL of sample. Cross-validation against enzyme-linked immunosorbent assay (ELISA) resulted in a high correlation between methods (r(2)=0.95 with a ρc=0.83) and the accuracy was in line with previously published results. In conclusion, a sensitive, robust and cost-effective method was developed for the bio-analysis of IFX with LC-MS/MS by means of a target-based pre-analytical sample purification. Moreover, low volume and costs of consumables per sample promote its feasibility in (pre)clinical studies and in therapeutic drug monitoring. This method should be considered as first choice due to its accuracy and multiple degree of selectivity.


Asunto(s)
Cromatografía Liquida/métodos , Infliximab/sangre , Espectrometría de Masas en Tándem/métodos , Factor de Necrosis Tumoral alfa/metabolismo , Cromatografía Liquida/economía , Cromatografía Liquida/normas , Análisis Costo-Beneficio , Humanos , Infliximab/aislamiento & purificación , Infliximab/metabolismo , Modelos Lineales , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/economía , Espectrometría de Masas en Tándem/normas , Factor de Necrosis Tumoral alfa/química
18.
J Pharm Sci ; 105(4): 1519-25, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27019966

RESUMEN

Pharmaceutical oil depots are meant to release active substances at a sustained rate. Most of these depots contain benzyl alcohol (BOH) to facilitate the production and administration. Because BOH changes the solubility of components in both the body fluid and the oil formulation, it is relevant to know the change in the BOH concentration in the oil over time. In this study, volunteers were subcutaneously injected with an oil depot that contained 10% BOH, nandrolone decanoate, and cholecalciferol. The aim of this study was to determine the pharmacokinetic profiles of BOH and its metabolites benzoic acid and hippuric acid simultaneously in serum to estimate the BOH release out of the depot. For this, an HPLC bioassay was developed and adequately validated. Hereafter, the bioassay was applied to serum samples obtained at several time points between 0 and 35 days. BOH appeared immediately in serum after injection. The pharmacokinetic profile revealed that all BOH was depleted from the depot within 52 h after injection. Thus, the partition coefficient of active substances between the oil formulation and the body tissue changes rapidly in the first days after injection but will remain constant hereafter.


Asunto(s)
Alcohol Bencilo/administración & dosificación , Alcohol Bencilo/sangre , Preparaciones de Acción Retardada/química , Aceites/química , Anciano , Ácido Benzoico/sangre , Ácido Benzoico/metabolismo , Alcohol Bencilo/metabolismo , Cromatografía Líquida de Alta Presión , Femenino , Hipuratos/sangre , Hipuratos/metabolismo , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...