Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Br J Clin Pharmacol ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38886107

RESUMEN

AIMS: Acute coronary syndrome (ACS) represents a major cause of death. Bisoprolol is commonly used in the management of ACS. This study aims to investigate the impact of CYP2D6*2A, CYP2D6*4 and CYP3A5*3 genetic polymorphisms on pharmacokinetics and clinical response of bisoprolol in ACS patients. METHODS: This is an open-label cohort study that included 127 ACS patients and studied the effect of CYP3A5*3, CYP2D6*2A and CYP2D6*4 genotyping using real-time polymerase chain reaction on steady state bisoprolol plasma peak concentration analysed by high performance liquid chromatography-fluorescence detector. RESULTS: Regarding CYP3A5*3, the mean peak bisoprolol concentration for CC, CT and TT genotypes were 4.25 ± 1.20, 3.93 ± 1.10 and 1.79 ± 0.69 ng/mL, respectively (P < .001). Higher systolic (126 ± 5.47 mmHg), diastolic blood pressure (82 ± 2.73 mmHg) and heart rate (97.80 ± 3.03 beats/min) were also observed in CYP3A5*3 TT carriers (P < .05). In CYP2D6*2A, the peak concentration of bisoprolol was lower in CC carriers (3.54 ± 1 ng/mL) compared to GG (4.38 ± 1.25 ng/mL) and GC carriers (4.07 ± 1.29 ng/mL, P = .019). In CYP2D6*4, the mean bisoprolol peak concentration in CC carriers was 3.98 ± 1.31 ng/mL, which was lower than T allele carriers (4.5 ± 0.8, P = .02). No differences in heart rate, systolic, diastolic blood pressure or bisoprolol dose were observed among CYP2D6*2A or CYP2D6*4 variants. Smokers exhibited lower bisoprolol peak concentration (3.96 ± 1.2 ng/mL) compared to nonsmokers (4.55 ± 1.34 ng/mL, P = .037). CONCLUSION: There is an association between CYP3A5*3, CYP2D6*4, CYP2D6*2A variants and bisoprolol peak concentration, which may serve as a guide in the future in choosing the optimum dose of bisoprolol in ACS patients.

2.
Arch Pharm (Weinheim) ; : e2400313, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38943448

RESUMEN

The evident ecological impact of human actions, like air pollution, global warming, and ozone depletion, underscores the need for environmentally friendly approaches across various domains, including analytical chemistry. This study aimed to establish a validated, eco-friendly, and sustainable approach utilizing a fluorescence detector coupled with high-performance liquid chromatography for quantifying the antihyperglycemic agent dapagliflozin (DAPA), in human plasma. This method employed a C18 Microsorb MV (4.5 × 250 mm, 5 µm [particle size]) column at 40°C, with 40:60% v/v isocratic elution of acetonitrile and (0.1%) orthophosphoric acid as the mobile phase at 1 mL/min flow rate. DAPA and the internal standard demonstrated their greatest response by performing excitation at 225 nm (λex) and recording chromatograms at an emission wavelength (λem) equal to 305 nm. The presented approach demonstrated high linearity between 50 and 2000 ng/mL and full adherence to the guidelines of the US Food and Drug Administration regarding the validation of bioanalytical methods. The described technique was effectively used for quantification of DAPA in human plasma samples from a healthy male participant who received a tablet of 10 mg DAPA. Analytical Eco-Scale, Analytical GREEnness metric, and the recently created ChlorTox Scale were utilized for greenness assessment. Additionally, the "Red, Green, and Blue 12" model was used in whiteness evaluation.

3.
BMC Chem ; 17(1): 132, 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37794494

RESUMEN

The establishment and validation of a straightforward, accurate, and eco-friendly capillary zone electrophoretic-diode array detection (CZE-DAD) procedure has been presented for concurrent measurement of two common antibiotics, namely, linezolid (LIN) and cefixime trihydrate (CEF), in their binary mixture or combined dosage form. The selected fused silica capillary has total and effective lengths equal to 58.5 cm and 50 cm, respectively, with a 50 µm internal diameter. Injections were performed utilizing 100 mM borate buffer at pH 10.2 as the background electrolyte (BGE) with a 15.0 s injection time. The finally utilized voltage was 30 kV. DAD was programmed to measure LIN at 250 nm and CEF at 285 nm. In less than 6 min, the two cited drugs were resolved at 2.51 and 5.47 min for LIN and CEF respectively. The introduced procedure had a linear response in the concentration range of 5-50 µg/mL for both analytes with correlation coefficients > 0.9999. Detection and quantification limits were 1.213 and 4.042 µg/mL, respectively, for LIN and 0.301 and 1.004 µg/mL, respectively, for CEF. Validation was conducted according to the International Council for Harmonization (ICH), concerning linearity, detection and quantitation limits, range, accuracy, precision, selectivity, and robustness. Precision was found acceptable due to the low relative standard deviation (RSD%) values that did not exceed 1.86% either for repeatability or for intermediate precision. Additionally, the adequately recovered concentrations and the low values of percentage relative error (Er%) provide evidence of the accuracy of the proposed method. On the other hand, the robustness of the introduced method was affirmed by the acceptable RSD% values that did not exceed 0.6% after deliberate changes in the following procedure parameters: buffer concentration, buffer pH, and wavelength. Finally, the ability of the presented method to quantify the two tested drugs in laboratory-prepared tablets was confirmed by the adequate recoveries (≥ 99%) utilizing the standard-addition procedure, along with the absence of any significant difference between the proposed method and the reference method as proven by the student's t-test and the variance-ratio F-test values that did not exceed the theoretical ones. The analytical Eco-Scale and the analytical GREEness metric (AGREE) were the tools utilized for greenness assessment. This CZE procedure is the first electro-driven separation method that was utilized for the analysis of both antibiotics in their combined laboratory-prepared tablets with no interference from the co-formulated adjuvants.

4.
BMC Chem ; 17(1): 124, 2023 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-37742031

RESUMEN

Implementing powerful and sustainable research that complies with green analytical chemistry (GAC) and white analytical chemistry (WAC) fundamentals can downsize the environmental compliance costs and fruitfully affects practical and economic issues. Within this framework, rapid and white analytical micellar electrokinetic capillary chromatography (MEKC) methodology was developed for the synchronized estimation of the antihyperlipidemic drugs Ezetimibe (EZE), Atorvastatin (ATO), Rosuvastatin (ROS) and Simvastatin (SIM). The technique was established using fused silica capillary (50 cm, 50 µm id) and the background electrolyte was 0.025 M borate buffer pH 9.2 containing 0.025 M sodium dodecyl sulfate (SDS) and 10% v/v acetonitrile as the organic modifier. Diode array detector was adjusted at 243 nm for ATO and ROS and 237 nm for EZE and SIM. Separation was accomplished within 10 min with migration times of 4.12, 5.42, 8.23 and 8.74 min for ROS, ATO, EZE and SIM respectively. The 4 drugs were quantitated in the concentration range of 10-100 µg/mL and the correlation coefficients were not less than 0.9993. The high sensitivity was illustrated by values of the detection and quantitation limits. The limits of detection for ROS, ATO, EZE and SIM were 0.52, 0.75, 0.42 and 0.64 µg/mL, respectively, whereas, the limits of quantitation values were 1.73, 2.50, 1.40 and 2.13 µg/mL for the studied drugs, respectively. In addition to validation, as reported by the ICH guidelines, greenness and whiteness assessment using the novel AGREE calculator and the holistic functionality model RGB12 were performed. The results proved the efficiency and whiteness of the suggested technique to be routinely implemented in quality control laboratories for the assay of the four drugs and the binary mixtures of EZE with either ATO, ROS or SIM in fixed-dose combined tablets.

5.
J AOAC Int ; 105(3): 739-747, 2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35015848

RESUMEN

BACKGROUND: The antiviral drug GS-5734 remdesivir is a new phosphoramidate prodrug developed initially as a treatment for Ebola virus which then proved to have antiviral properties against other viruses. After clinical trials, it was the first antiviral to be approved by the U.S. Food and Drug Administration in 2020 to treat severe coronavirus (COVID-19) cases. The widespread current pandemic gave an urge to its fast production and marketing. Thus, new analytical methods must be available for its analysis in a fast and easy manner with low cost to be applicable in all laboratories. OBJECTIVE: In the current study, a green and economic micellar electrokinetic chromatographic (MEKC) method is proposed for remdesivir analysis. METHODS: A fused-silica capillary (58.5 cm × 50 µm id, 50 cm effective length) with 20 mM borate buffer (pH 9) and 25 mM sodium dodecyl sulfate was used under a positive potential of 30 kV at 25°C with detection at 245 nm. RESULTS: Remdesivir analysis was achieved in approximately 5 min. The method proved to be linear in range of 1-50 µg/mL with correlation coefficient, r > 0.999. CONCLUSION: The MEKC method proposed was applied to the analysis of remdesivir in its commercial vials. The method was validated per International Conference on Harmonization guidelines. HIGHLIGHTS: Green chemistry has been the focus of the analytical community in the past few years. This method is considered green due to its low energy and solvent consumption without sacrificing the method's sensitivity or selectivity. The method's green profile has been assessed by different greenness assessment scales to ensure the method is eco-friendly and can be used in the pharmaceutical industry.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Cromatografía Capilar Electrocinética Micelar , Adenosina Monofosfato/análogos & derivados , Alanina/análogos & derivados , Antivirales , Cromatografía Capilar Electrocinética Micelar/métodos , Humanos , Micelas , Reproducibilidad de los Resultados
6.
J AOAC Int ; 104(2): 339-347, 2021 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-33259587

RESUMEN

OBJECTIVE: Two chromatographic methods were described for simultaneous determination of the antihypertensive drugs amlodipine besylate (AML) and bisoprolol fumarate (BIS). METHODS: Method I applies micellar electrokinetic capillary chromatography using a deactivated fused silica capillary (25 cm effective length × 50 µm internal diameter). The background electrolyte consisted of 0.01 M borate buffer (pH 9.2) containing 0.025 M sodium dodecyl sulphate and methanol in the ratio of 80:20 (v/v). Valsartan (VAL) was used as an internal standard. Diode array detector was set at 238, 224, and 210 nm for measuring AML, BIS, and VAL, respectively. Method II involves using ultra-performance liquid chromatography with fluorescence detection. Zorbax SB-C8 column (2.1 × 100 mm, 1.8 µm particle size) was used with isocratic elution of the mobile phase composed of 0.1% trifluoroacetic acid, acetonitrile, and methanol in the ratio of 55:35:10 (v/v) at a flow rate of 0.6 mL/min. Fluorescence detection was done using excitation wavelengths 230 and 370 nm and emission wavelengths 305 and 450 nm for BIS and AML, respectively. Validation parameters were carefully studied including linearity, ranges, precision, accuracy, robustness, detection, and quantification limits. RESULTS: Method I showed good linearity over the range 10-100 µg/mL for both dugs. Method II's linear ranges were 0.001-0.1 and 0.02-1 µg/mL for BIS and AML, respectively. CONCLUSION: The proposed methods were successfully validated and applied for assay of the studied drugs in their fixed-dose combination tablets. HIGHLIGHTS: To the best of our knowledge, this study suggests the first electro-chromatographic and LC with fluorescence detection methods for simultaneous determination of amlodipine and bisoprolol.


Asunto(s)
Amlodipino , Cromatografía Capilar Electrocinética Micelar , Antihipertensivos , Bisoprolol , Cromatografía Líquida de Alta Presión , Valsartán
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...