Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
MAGMA ; 27(1): 63-70, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23748497

RESUMEN

OBJECT: MR imaging of low-gamma nuclei at the ultrahigh magnetic field of 21.1 T provides a new opportunity for understanding a variety of biological processes. Among these, chlorine and sodium are attracting attention for their involvement in brain function and cancer development. MATERIALS AND METHODS: MRI of (35)Cl and (23)Na were performed and relaxation times were measured in vivo in normal rat (n = 3) and in rat with glioma (n = 3) at 21.1 T. The concentrations of both nuclei were evaluated using the center-out back-projection method. RESULTS: T 1 relaxation curve of chlorine in normal rat head was fitted by bi-exponential function (T 1a = 4.8 ms (0.7) T 1b = 24.4 ± 7 ms (0.3) and compared with sodium (T 1 = 41.4 ms). Free induction decays (FID) of chlorine and sodium in vivo were bi-exponential with similar rapidly decaying components of [Formula: see text] ms and [Formula: see text] ms, respectively. Effects of small acquisition matrix and bi-exponential FIDs were assessed for quantification of chlorine (33.2 mM) and sodium (44.4 mM) in rat brain. CONCLUSION: The study modeled a dramatic effect of the bi-exponential decay on MRI results. The revealed increased chlorine concentration in glioma (~1.5 times) relative to a normal brain correlates with the hypothesis asserting the importance of chlorine for tumor progression.


Asunto(s)
Neoplasias Encefálicas/patología , Cloro/química , Glioma/patología , Imagen por Resonancia Magnética/métodos , Sodio/química , Animales , Progresión de la Enfermedad , Diseño de Equipo , Imagenología Tridimensional , Ratas
2.
J Magn Reson ; 221: 110-6, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22750638

RESUMEN

A tunable 900 MHz transmit/receive volume coil was constructed for ¹H MR imaging of biological samples in a 21.1 T vertical bore magnet. To accommodate a diverse range of specimen and RF loads at such a high frequency, a sliding-ring adaptation of a low-pass birdcage was implemented through simultaneous alteration of distributed capacitance. To make efficient use of the constrained space inside the vertical bore, a modular probe design was implemented with a bottom-adjustable tuning and matching apparatus. The sliding ring coil displays good homogeneity and sufficient tuning range for different samples of various dimensions representing large span of RF loads. High resolution in vivo and ex vivo images of large rats (up to 350 g), mice and human postmortem tissues were obtained to demonstrate coil functionality and to provide examples of potential applications at 21.1 T.


Asunto(s)
Neuroimagen/instrumentación , Algoritmos , Enfermedad de Alzheimer/patología , Animales , Encéfalo/patología , Cadáver , Campos Electromagnéticos , Diseño de Equipo , Humanos , Ratones , Fantasmas de Imagen , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...