Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Pharm Biomed Anal ; 31(5): 937-51, 2003 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-12684106

RESUMEN

Roxifiban (DMP 754) is a glycoprotein (GP) IIb/IIIa antagonist. Following oral administration to humans, roxifiban is metabolized to its primary active zwitterionic form, XV459, and several minor, active, hydrolyzed and hydroxylated metabolites, namely, M1a (DPC-AD3508), M1b (DPC-AD6128), M2 (SW156), M3 (DPC-AG2185), M8a (DPC-AF5814), and M8b (DPC-AF5818). Quantification of these metabolites in humans was not workable with a previous analytical method due to ion suppression of at least four of the analytes by a competitive displacer, DMP 728. This compound, which is another GP IIb/IIIa antagonist with very high affinity for the platelet receptor, was added to harvested blood samples in millimolar quantity to liberate XV459 from the GP IIb/IIIa receptor. An automated ion exchange solid phase extraction (IX-SPE) procedure was developed to selectively extract the seven metabolites of roxifiban and its deuterated internal standard while specifically excluding DMP 728. Among the six hydroxylation metabolites, there were two pairs of epimeric diastereomers (M1a/M1b and M8a/M8b) and one pair of geometric isomers (M2/M3), corresponding to three critical chromatographic pairs that needed to be base-line resolved because of the lack of specificity of MS/MS detection for these isomers. A new LC/MS/MS assay was developed to simultaneously quantify the seven metabolites in human plasma. The assay method was validated under GLP conditions over the concentration range of 0.5 to 80 nM for each of the analytes and successfully applied to assaying approximately 500 plasma samples from clinical trials.


Asunto(s)
Amidinas/sangre , Isoxazoles/sangre , Mesilatos/sangre , Péptidos Cíclicos/sangre , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Amidinas/metabolismo , Calibración , Cromatografía Líquida de Alta Presión/métodos , Humanos , Isoxazoles/metabolismo , Espectrometría de Masas/métodos , Reproducibilidad de los Resultados
2.
J Chromatogr B Biomed Sci Appl ; 761(2): 195-201, 2001 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-11587349

RESUMEN

A method for the quantification of 2'-deoxy-3'-thiacytidine (lamivudine, 3-TC), which incorporated the use of 3-isobutyl-methylxanthine as internal standard (I.S.) was developed and validated in human plasma, using HPLC with UV absorbance detection. Using solid-phase extraction, 3-TC and I.S. were selectively extracted from human plasma. Subsequently, chromatographic separation was performed using a YMC phenyl column with ion-pair chromatography and detection at 270 nm. The method was validated over a concentration range of 10 to 5,000 ng/ml using 0.5 ml of human plasma. The extraction recovery for both 3-TC and I.S. was greater than 95%. The determination of inter- and intra-day precision (RSD) was less than 10% at all concentration levels, while the inter- and intra-day accuracy (% difference) was less than 6%.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Lamivudine/sangre , Inhibidores de la Transcriptasa Inversa/sangre , Humanos , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Thromb Res ; 86(3): 221-32, 1997 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-9175243

RESUMEN

The pharmacokinetic-pharmacodynamic (PK/PD) relationship of a novel platelet glycoprotein IIb/IIIa receptor antagonist, XU063, was evaluated as a function of biological matrix in beagle dogs. The disposition of 14C-radioactivity in various blood or plasma matrices and kinetics of inhibition of adenosine diphosphate (ADP) induced platelet aggregation were determined in beagle dogs following an intravenous infusion of 14C-XU063 at 2 micrograms/kg for 45 min. The 14C-radioactivity was maximum in platelet poor plasma (PPP) harvested from blood collected in EDTA and lowest in PPP harvested from blood collected in citrated vacutainers over the entire concentration versus time profile during and post infusion. The 14C-radioactivity values in blood and platelet rich plasma (PRP) were comparable and were between EDTA PPP and citrated PPP values. The resultant estimates of the PK and PD parameters of 14C-XU063 varied widely depending on the type of matrix used. The systemic clearance values for 14C-XU063 were 1 and 10 mL/min/kg for EDTA and citrated PPP, respectively. The values for the volume of distribution at steady-state were 0.2 and 1.3 L/kg, for EDTA and citrated PPP, respectively. The terminal elimination half-life appeared independent of the matrix with a median value of 2 h. The estimated ex vivo IC50 values of XU063 ranged from 0.4 ng/mL (citrated PPP, platelet free drug) to 7 ng/mL (EDTA PPP, total drug). These results demonstrated the dependence of PK and PD parameters of antiplatelet agent XU063 on the type of biological matrix used to determine concentrations of XU063. The pros and cons of various blood sample collection methods for the evaluation of PK/PD relationship of potential antiplatelet agents are presented.


Asunto(s)
Isoxazoles/farmacología , Isoxazoles/farmacocinética , Inhibidores de Agregación Plaquetaria/farmacología , Inhibidores de Agregación Plaquetaria/farmacocinética , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Adenosina Difosfato/farmacología , Animales , Análisis Químico de la Sangre/métodos , Proteínas Sanguíneas/metabolismo , Recolección de Muestras de Sangre/métodos , Perros , Semivida , Técnicas In Vitro , Masculino , Tasa de Depuración Metabólica , Agregación Plaquetaria/efectos de los fármacos , Unión Proteica
4.
J Pharm Biomed Anal ; 14(12): 1717-25, 1996 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8887719

RESUMEN

A sensitive and specific high-performance liquid chromatographic method with electrochemical detection was developed for the simultaneous determination of naltrexone and its major metabolite, 6-beta-naltrexol, in human plasma. After alkalinizing 2 ml plasma samples with pH 9 sodium carbonate buffer, naltrexone and 6-beta-naltrexol were extracted into dichloromethane and then back-extracted into 0.017 M phosphoric acid. A portion of the acid extract was chromatographed on a YMC phenyl column using a mobile phase of methanol-phosphoric acid (50 mM) (20:80, v/v) (pH* 3.2) at a flow-rate of 1.2 ml min 1. Quantification was performed using an ESA Coulometric electrochemical detector. Acceptable intra-day and assay precision (RSD < 10%) and accuracy (< 16%) for both compounds were observed over concentration ranges of 0.25-50.0 ng ml-1 for naltrexone and 0.5-100 ng ml-1 for 6-beta-naltrexol. No degradation of either naltrexone or 6-beta-naltrexol was observed in frozen human plasma stored at -20 degrees C over an 8 month period. The method is sufficiently sensitive and selective to quantify plasma concentrations of naltrexone and 6-beta-naltrexol after oral doses of 50 mg of naltrexone to healthy subjects or alcoholic patients.


Asunto(s)
Naltrexona/análogos & derivados , Naltrexona/sangre , Antagonistas de Narcóticos/sangre , Cromatografía Liquida/métodos , Electroquímica/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Chromatogr B Biomed Appl ; 675(2): 273-8, 1996 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-8852715

RESUMEN

A sensitive and selective high-performance liquid chromatographic method for the determination of XR510 (I), a new non-peptide angiotensin II (AII) receptor antagonist with balanced affinity for AT1 and AT2 receptor subtypes is described. I and the internal standard, XR513, were extracted from acidified plasma by combined liquid-liquid/solid-phase extraction and chromatographed on a phenyl column with ultraviolet absorbance detection at a wavelength of 272 nm. The mobile phase consisted of a mixture of acetonitrile and sodium phosphate buffer. For both rat and dog plasma, the limit of quantitation was 5 ng/ml. This method has been validated and successfully utilized to investigate the disposition of I.


Asunto(s)
Antagonistas de Receptores de Angiotensina , Compuestos de Bifenilo/sangre , Cromatografía Líquida de Alta Presión/métodos , Imidazoles/sangre , Animales , Perros , Ratas , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría Ultravioleta
6.
J Chromatogr B Biomed Appl ; 657(1): 254-60, 1994 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-7952079

RESUMEN

A specific and sensitive HPLC assay for the determination of DMP 728 in dog and rat plasma has been developed. The method involves solid-phase extraction of DMP 728 and the internal standard from plasma using a C2 column. The extracted compounds are derivatized with benzoin under alkaline conditions. Using a mixture of acetonitrile and 0.1 M potassium phosphate buffer (25:75, v/v, pH 7.4) as mobile phase, the derivatized products are separated on a Regis semipermeable surface C8 column and monitored fluorometrically using 325 nm and 425 nm as excitation and emission wavelengths, respectively. The assay is linear from 2.5 to 1000 ng/ml in dog plasma and from 5 to 1000 ng/ml in rat plasma. The limit of quantitation is 2.5 ng/ml using 0.5 ml of dog plasma and 5 ng/ml using 0.5 ml of rat plasma. The assay has been used in pharmacokinetic studies of DMP 728 in dogs and rats.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Mesilatos/sangre , Péptidos Cíclicos/sangre , Inhibidores de Agregación Plaquetaria/sangre , Glicoproteínas de Membrana Plaquetaria/antagonistas & inhibidores , Acetonitrilos , Animales , Benzoína , Cromatografía Líquida de Alta Presión/estadística & datos numéricos , Perros , Femenino , Concentración de Iones de Hidrógeno , Hidróxidos , Mesilatos/farmacocinética , Péptidos Cíclicos/farmacocinética , Fosfatos , Inhibidores de Agregación Plaquetaria/farmacocinética , Compuestos de Potasio , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Temperatura , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...