1.
Eur Radiol Exp ; 8(1): 70, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38890175

RESUMEN

BACKGROUND: The potential role of cardiac computed tomography (CT) has increasingly been demonstrated for the assessment of diffuse myocardial fibrosis through the quantification of extracellular volume (ECV). Photon-counting detector (PCD)-CT technology may deliver more accurate ECV quantification compared to energy-integrating detector CT. We evaluated the impact of reconstruction settings on the accuracy of ECV quantification using PCD-CT, with magnetic resonance imaging (MRI)-based ECV as reference. METHODS: In this post hoc analysis, 27 patients (aged 53.1 ± 17.2 years (mean ± standard deviation); 14 women) underwent same-day cardiac PCD-CT and MRI. Late iodine CT scans were reconstructed with different quantum iterative reconstruction levels (QIR 1-4), slice thicknesses (0.4-8 mm), and virtual monoenergetic imaging levels (VMI, 40-90 keV); ECV was quantified for each reconstruction setting. Repeated measures ANOVA and t-test for pairwise comparisons, Bland-Altman plots, and Lin's concordance correlation coefficient (CCC) were used. RESULTS: ECV values did not differ significantly among QIR levels (p = 1.000). A significant difference was observed throughout different slice thicknesses, with 0.4 mm yielding the highest agreement with MRI-based ECV (CCC = 0.944); 45-keV VMI reconstructions showed the lowest mean bias (0.6, 95% confidence interval 0.1-1.4) compared to MRI. Using the most optimal reconstruction settings (QIR4. slice thickness 0.4 mm, VMI 45 keV), a 63% reduction in mean bias and a 6% increase in concordance with MRI-based ECV were achieved compared to standard settings (QIR3, slice thickness 1.5 mm; VMI 65 keV). CONCLUSIONS: The selection of appropriate reconstruction parameters improved the agreement between PCD-CT and MRI-based ECV. RELEVANCE STATEMENT: Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility. KEY POINTS: • CT is increasingly promising for myocardial tissue characterization, assessing focal and diffuse fibrosis via late iodine enhancement and ECV quantification, respectively. • PCD-CT offers superior performance over conventional CT, potentially improving ECV quantification and its agreement with MRI-based ECV. • Tailoring PCD-CT reconstruction parameters optimizes ECV quantification compared to MRI, potentially improving its clinical utility.


Asunto(s)
Imagen por Resonancia Magnética , Miocardio , Tomografía Computarizada por Rayos X , Humanos , Femenino , Persona de Mediana Edad , Masculino , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Anciano , Fotones , Adulto , Procesamiento de Imagen Asistido por Computador/métodos , Corazón/diagnóstico por imagen
2.
Eur J Radiol ; 176: 111517, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38805884

RESUMEN

PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria , Fantasmas de Imagen , Fotones , Relación Señal-Ruido , Humanos , Angiografía por Tomografía Computarizada/métodos , Masculino , Femenino , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Algoritmos
3.
Eur J Radiol ; 176: 111534, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38820951

RESUMEN

PURPOSE: Radiological reporting is transitioning to quantitative analysis, requiring large-scale multi-center validation of biomarkers. A major prerequisite and bottleneck for this task is the voxelwise annotation of image data, which is time-consuming for large cohorts. In this study, we propose an iterative training workflow to support and facilitate such segmentation tasks, specifically for high-resolution thoracic CT data. METHODS: Our study included 132 thoracic CT scans from clinical practice, annotated by 13 radiologists. In three iterative training experiments, we aimed to improve and accelerate segmentation of the heart and mediastinum. Each experiment started with manual segmentation of 5-25 CT scans, which served as training data for a nnU-Net. Further iterations incorporated AI pre-segmentation and human correction to improve accuracy, accelerate the annotation process, and reduce human involvement over time. RESULTS: Results showed consistent improvement in AI model quality with each iteration. Resampled datasets improved the Dice similarity coefficients for both the heart (DCS 0.91 [0.88; 0.92]) and the mediastinum (DCS 0.95 [0.94; 0.95]). Our AI models reduced human interaction time by 50 % for heart and 70 % for mediastinum segmentation in the most potent iteration. A model trained on only five datasets achieved satisfactory results (DCS > 0.90). CONCLUSIONS: The iterative training workflow provides an efficient method for training AI-based segmentation models in multi-center studies, improving accuracy over time and simultaneously reducing human intervention. Future work will explore the use of fewer initial datasets and additional pre-processing methods to enhance model quality.


Asunto(s)
Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Inteligencia Artificial , Mediastino/diagnóstico por imagen , Corazón/diagnóstico por imagen
4.
Diagnostics (Basel) ; 14(9)2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38732280

RESUMEN

This study evaluated a deep neural network (DNN) algorithm for automated aortic diameter quantification and aortic dissection detection in chest computed tomography (CT). A total of 100 patients (median age: 67.0 [interquartile range 55.3/73.0] years; 60.0% male) with aortic aneurysm who underwent non-enhanced and contrast-enhanced electrocardiogram-gated chest CT were evaluated. All the DNN measurements were compared to manual assessment, overall and between the following subgroups: (1) ascending (AA) vs. descending aorta (DA); (2) non-obese vs. obese; (3) without vs. with aortic repair; (4) without vs. with aortic dissection. Furthermore, the presence of aortic dissection was determined (yes/no decision). The automated and manual diameters differed significantly (p < 0.05) but showed excellent correlation and agreement (r = 0.89; ICC = 0.94). The automated and manual values were similar in the AA group but significantly different in the DA group (p < 0.05), similar in obese but significantly different in non-obese patients (p < 0.05) and similar in patients without aortic repair or dissection but significantly different in cases with such pathological conditions (p < 0.05). However, in all the subgroups, the automated diameters showed strong correlation and agreement with the manual values (r > 0.84; ICC > 0.9). The accuracy, sensitivity and specificity of DNN-based aortic dissection detection were 92.1%, 88.1% and 95.7%, respectively. This DNN-based algorithm enabled accurate quantification of the largest aortic diameter and detection of aortic dissection in a heterogenous patient population with various aortic pathologies. This has the potential to enhance radiologists' efficiency in clinical practice.

5.
Acad Radiol ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38734579

RESUMEN

RATIONALE AND OBJECTIVES: Coronary CT angiography (CCTA) has recently been established as a first-line test in patients with suspected coronary artery disease (CAD). Due to the increased use of CCTA, strategies to reduce radiation and contrast medium (CM) exposure are of high importance. The aim of this study was to evaluate the performance of automated tube voltage selection (ATVS)-adapted CM injection protocol for CCTA compared to a clinically established triphasic injection protocol in terms of image quality, radiation exposure, and CM administration MATERIAL AND METHODS: Patients undergoing clinically indicated CCTA were prospectively enrolled from July 2021 to July 2023. Patients underwent CCTA using a modified triphasic CM injection protocol tailored to the tube voltage by the ATVS algorithm, in a range of 70 to 130 kV with a 10 kV interval. The injection protocol consisted of two phases of mixed CM and saline boluses with different proportions to assure a voltage-specific iodine delivery rate, followed by a third phase of saline flush. This cohort was compared to a control group identified retrospectively and scanned on the same CT system but with a standard triphasic CM protocol. Radiation and contrast dose, subjective and objective image quality (contrast-to-noise-ratio [CNR] and signal-to-noise-ratio [SNR]) were compared between the two groups. RESULTS: The final population consisted of 120 prospective patients matched with 120 retrospective controls, with 20 patients in each kV group. The 120 kV group was excluded from the statistical analysis due to insufficient sample size. A significant CM reduction was achieved in the prospective group overall (46.0 [IQR 37.0-52.0] vs. 51.3 [IQR 40.1-73.0] mL, p < 0.001) and at all kV levels too (all pairwise p < 0.001). There were no significant differences in radiation dose (6.13 ± 4.88 vs. 5.97 ± 5.51 mSv, p = 0.81), subjective image quality (median score of 4 [3-5] vs. 4 [3-5], p = 0.40), CNR, and SNR in the aorta and the left anterior descending coronary artery (all p > 0.05). CONCLUSION: ATVS-adapted CM injection protocol allows for diagnostic quality CCTA with reduced CM volume while maintaining similar radiation exposure, subjective and objective image quality.

6.
Eur J Radiol ; 174: 111386, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38447431

RESUMEN

PURPOSE: Studies have shown the incremental value of strain imaging in various cardiac diseases. However, reproducibility and generalizability has remained an issue of concern. To overcome this, simplified algorithms such as rapid atrioventricular strains have been proposed. This multicenter study aimed to assess the reproducibility of rapid strains in a real-world setting and identify potential predictors for higher interobserver variation. METHODS: A total of 4 sites retrospectively identified 80 patients and 80 healthy controls who had undergone cardiac magnetic resonance imaging (CMR) at their respective centers using locally available scanners with respective field strengths and imaging protocols. Strain and volumetric parameters were measured at each site and then independently re-evaluated by a blinded core lab. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess inter-observer agreement. In addition, backward multiple linear regression analysis was performed to identify predictors for higher inter-observer variation. RESULTS: There was excellent agreement between sites in feature-tracking and rapid strain values (ICC ≥ 0.96). Bland-Altman plots showed no significant bias. Bi-atrial feature-tracking and rapid strains showed equally excellent agreement (ICC ≥ 0.96) but broader limits of agreement (≤18.0 % vs. ≤3.5 %). Regression analysis showed that higher field strength and lower temporal resolution (>30 ms) independently predicted reduced interobserver agreement for bi-atrial strain parameters (ß = 0.38, p = 0.02 for field strength and ß = 0.34, p = 0.02 for temporal resolution). CONCLUSION: Simplified rapid left ventricular and bi-atrial strain parameters can be reliably applied in a real-world multicenter setting. Due to the results of the regression analysis, a minimum temporal resolution of 30 ms is recommended when assessing atrial deformation.


Asunto(s)
Imagen por Resonancia Cinemagnética , Imagen por Resonancia Magnética , Humanos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Imagen por Resonancia Cinemagnética/métodos , Atrios Cardíacos , Variaciones Dependientes del Observador , Función Ventricular Izquierda
7.
Radiology ; 310(2): e231956, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38376407

RESUMEN

Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Humanos , Masculino , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Constricción Patológica , Angiografía por Tomografía Computarizada , Estudios Retrospectivos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Angiografía Coronaria
8.
Eur Radiol ; 34(4): 2140-2151, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38379017

RESUMEN

Cardiovascular MR imaging has become an indispensable noninvasive tool in diagnosing and monitoring a broad range of cardiovascular diseases. Key to its clinical success and efficiency are appropriate clinical indication triage, technical expertise, patient safety, standardized preparation and execution, quality assurance, efficient post-processing, structured reporting, and communication and clinical integration of findings. Technological advancements are driving faster, more accessible, and cost-effective approaches. This ESR Essentials article presents a ten-step guide for implementing a cardiovascular MR program, covering indication assessments, optimized imaging, post-processing, and detailed reporting. Future goals include streamlined protocols, improved tissue characterization, and automation for greater standardization and efficiency. CLINICAL RELEVANCE STATEMENT: The growing clinical role of cardiovascular MR in risk assessment, diagnosis, and treatment planning highlights the necessity for radiologists to achieve expertise in this modality, advancing precision medicine and healthcare efficiency. KEY POINTS: • Cardiovascular MR is essential in diagnosing and monitoring many acute and chronic cardiovascular pathologies. • Features such as technical expertise, quality assurance, patient safety, and optimized tailored imaging protocols, among others, are essential for a successful cardiovascular MR program. • Ongoing technological advances will push rapid multi-parametric cardiovascular MR, thus improving accessibility, patient comfort, and cost-effectiveness. KEY POINTS: • Cardiovascular MR is essential in diagnosing and monitoring a wide array of cardiovascular pathologies (Level of Evidence: High). • A successful cardiovascular MR program depends on standardization (Level of Evidence: Low). • Future developments will increase the efficiency and accessibility of cardiovascular MR (Level of Evidence: Low).


Asunto(s)
Enfermedades Cardiovasculares , Corazón , Humanos , Imagen por Resonancia Magnética/métodos , Enfermedades Cardiovasculares/diagnóstico por imagen
9.
AJR Am J Roentgenol ; 222(3): e2330481, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38197760

RESUMEN

BACKGROUND. Calcium blooming causes stenosis overestimation on coronary CTA. OBJECTIVE. The purpose of this article was to evaluate the impact of virtual monoenergetic imaging (VMI) reconstruction level on coronary artery stenosis quantification using photon-counting detector (PCD) CT. METHODS. A phantom containing two custom-made vessels (representing 25% and 50% stenosis) underwent PCD CT acquisitions without and with simulated cardiac motion. A retrospective analysis was performed of 33 patients (seven women, 26 men; mean age, 71.3 ± 9.0 [SD] years; 64 coronary artery stenoses) who underwent coronary CTA by PCD CT followed by invasive coronary angiography (ICA). Scans were reconstructed at nine VMI energy levels (40-140 keV). Percentage diameter stenosis (PDS) was measured, and bias was determined from the ground-truth stenosis percentage in the phantom and ICA-derived quantitative coronary angiography measurements in patients. Extent of blooming artifact was measured in the phantom and in calcified and mixed plaques in patients. RESULTS. In the phantom, PDS decreased for 25% stenosis from 59.9% (40 keV) to 13.4% (140 keV) and for 50% stenosis from 81.6% (40 keV) to 42.3% (140 keV). PDS showed lowest bias for 25% stenosis at 90 keV (bias, 1.4%) and for 50% stenosis at 100 keV (bias, -0.4%). Blooming artifacts decreased for 25% stenosis from 61.5% (40 keV) to 35.4% (140 keV) and for 50% stenosis from 82.7% (40 keV) to 52.1% (140 keV). In patients, PDS for calcified plaque decreased from 70.8% (40 keV) to 57.3% (140 keV), for mixed plaque decreased from 69.8% (40 keV) to 56.3% (140 keV), and for noncalcified plaque was 46.6% at 40 keV and 54.6% at 140 keV. PDS showed lowest bias for calcified plaque at 100 keV (bias, 17.2%), for mixed plaque at 140 keV (bias, 5.0%), and for noncalcified plaque at 40 keV (bias, -0.5%). Blooming artifacts decreased for calcified plaque from 78.4% (40 keV) to 48.6% (140 keV) and for mixed plaque from 73.1% (40 keV) to 44.7% (140 keV). CONCLUSION. For calcified and mixed plaque, stenosis severity measurements and blooming artifacts decreased at increasing VMI reconstruction levels. CLINICAL IMPACT. PCD CT with VMI reconstruction helps overcome current limitations in stenosis quantification on coronary CTA.


Asunto(s)
Estenosis Coronaria , Placa Aterosclerótica , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada/métodos , Estudios Retrospectivos , Constricción Patológica , Tomografía Computarizada por Rayos X/métodos , Estenosis Coronaria/diagnóstico por imagen
10.
J Thorac Imaging ; 39(2): 101-110, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37265250

RESUMEN

PURPOSE: The purpose of this study was to investigate the effect of integrated evaluation of resting static computed tomography perfusion (CTP) and coronary computed tomography angiography (CCTA)-derived fractional flow reserve (FFR CT ) on therapeutic decision-making and predicting major adverse cardiovascular events (MACEs) in patients with suspected coronary artery disease. MATERIALS AND METHODS: In this post hoc analysis of a prospective trial of CCTA in patients assigned to either CCTA or CCTA plus FFR CT arms, 500 patients in the CCTA plus FFR CT arm were analyzed. Both resting static CTP and FFR CT were evaluated by using the conventional CCTA. Perfusion defects in the myocardial segments with ≥50% degree of stenosis in the supplying vessels were defined as resting static CTP positive, and any vessel with an FFR CT value of ≤0.80 was considered positive. Patients were divided into 3 groups: (1) negative CTP-FFR CT match group (resting static CTP-negative and FFR CT -negative group); (2) mismatch CTP-FFR CT group (resting static CTP-positive and FFR CT -negative or resting static CTP-negative and FFR CT -positive group); and (3) positive CTP-FFR CT match group (resting static CTP-positive and FFR CT -positive group). We compared the revascularization-to-invasive coronary angiography ratio and the MACE rate among 3 subgroups at 1- and 3-year follow-ups. The adjusted Cox hazard proportional model was used to assess the prognostic value of FFR CT and resting static CTP to determine patients at risk of MACE. RESULTS: Patients in the positive CTP-FFR CT match group were more likely to undergo revascularization at the time of invasive coronary angiography compared with those in the mismatch CTP-FFR CT group (81.4% vs 57.7%, P =0.033) and the negative CTP-FFR CT match group (81.4% vs 33.3%, P= 0.001). At 1- and 3-year follow-ups, patients in the positive CTP-FFR CT match group were more likely to have MACE than those in the mismatch CTP-FFR CT group (10.5% vs 4.2%, P= 0.046; 35.6% vs 9.4%, P <0.001) and the negative CTP-FFR CT match group (10.5% vs 0.9%, P <0.001; 35.6% vs 5.4%, P <0.001). A positive CTP-FFR CT match was strongly related to MACE at 1-year (hazard ratio=8.06, P= 0.003) and 3-year (hazard ratio=6.23, P <0.001) follow-ups. CONCLUSION: In patients with suspected coronary artery disease, the combination of FFR CT with resting static CTP could guide therapeutic decisions and have a better prognosis with fewer MACE in a real-world scenario.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Ensayos Clínicos como Asunto
11.
J Thorac Imaging ; 39(2): 93-100, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37889562

RESUMEN

PURPOSE: To evaluate a novel deep learning (DL)-based automated coronary labeling approach for structured reporting of coronary artery disease according to the guidelines of the Society of Cardiovascular Computed Tomography (CT) on coronary CT angiography (CCTA). PATIENTS AND METHODS: A retrospective cohort of 104 patients (60.3 ± 10.7 y, 61% males) who had undergone prospectively electrocardiogram-synchronized CCTA were included. Coronary centerlines were automatically extracted, labeled, and validated by 2 expert readers according to Society of Cardiovascular CT guidelines. The DL algorithm was trained on 706 radiologist-annotated cases for the task of automatically labeling coronary artery centerlines. The architecture leverages tree-structured long short-term memory recurrent neural networks to capture the full topological information of the coronary trees by using a two-step approach: a bottom-up encoding step, followed by a top-down decoding step. The first module encodes each sub-tree into fixed-sized vector representations. The decoding module then selectively attends to the aggregated global context to perform the local assignation of labels. To assess the performance of the software, percentage overlap was calculated between the labels of the algorithm and the expert readers. RESULTS: A total number of 1491 segments were identified. The artificial intelligence-based software approach yielded an average overlap of 94.4% compared with the expert readers' labels ranging from 87.1% for the posterior descending artery of the right coronary artery to 100% for the proximal segment of the right coronary artery. The average computational time was 0.5 seconds per case. The interreader overlap was 96.6%. CONCLUSIONS: The presented fully automated DL-based coronary artery labeling algorithm provides fast and precise labeling of the coronary artery segments bearing the potential to improve automated structured reporting for CCTA.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Aprendizaje Profundo , Masculino , Humanos , Femenino , Angiografía por Tomografía Computarizada/métodos , Inteligencia Artificial , Estudios Retrospectivos , Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen
12.
Radiologie (Heidelb) ; 64(2): 134-141, 2024 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-37947866

RESUMEN

Posttraumatic instability accounts for more than 95% of all shoulder instabilities with the highest incidence in patients between 20 and 30 years of age. In this age group, lesions of the capsulolabral complex are the most common sequelae after the first shoulder dislocation. Typical acute findings are the Bankart and Perthes lesions and humeral avulsion of the glenohumeral ligament (HAGL). Chronic sequelae are anterior labroligamentous periosteal sleeve avulsion (ALPSA) lesions, and nonclassifiable lesions with deficient anterioinferior labrum and glenohumeral ligaments. Recently, quantification of Hill-Sachs and bony Bankart lesions with glenoid defects have become the focus of interest: bipolar bone loss has emerged to be one important factor of recurrent instability that has not been addressed during the first stabilizing operation. The glenoid track concept emphasizes the importance of bipolar bone loss, where the glenoid track refers to the contact area between the humeral head and the glenoid at the end-range of motion in abduction, extension and external rotation. Any lesion of the humeral head that extends beyond the glenoid track is considered high risk for engagement of the humeral head at the glenoid margin with subsequent dislocation. Both the Hill-Sachs interval and the glenoid track can be determined using computed tomography (CT) and magnetic resonance imaging and, thus, help to define the status of the shoulder (on-track vs. off-track), which is prerequisite for planning the appropriate operative procedure. Similar tendencies also exist for posttraumatic posterior instabilities which are much rarer.


Asunto(s)
Inestabilidad de la Articulación , Luxación del Hombro , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/cirugía , Hombro , Luxación del Hombro/diagnóstico por imagen , Luxación del Hombro/cirugía , Luxación del Hombro/complicaciones , Cabeza Humeral/patología , Cabeza Humeral/cirugía
13.
Eur Radiol ; 34(3): 1692-1703, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658887

RESUMEN

OBJECTIVES: 2D real-time (RT) phase-contrast (PC) MRI is a promising alternative to conventional PC MRI, which overcomes problems due to irregular heartbeats or poor respiratory control. This study aims to evaluate a prototype compressed sensing (CS)-accelerated 2D RT-PC MRI technique with shared velocity encoding (SVE) for accurate beat-to-beat flow measurements. METHODS: The CS RT-PC technique was implemented using a single-shot fast RF-spoiled gradient echo with SVE by symmetric velocity encoding, and acquired with a temporal resolution of 51-56.5 ms in 1-5 heartbeats. Both aortic dissection phantom (n = 8) and volunteer (n = 7) studies were conducted using the prototype CS RT (CS, R = 8), the conventional (GRAPPA, R = 2), and the fully sampled PC sequences on a 3T clinical system. Flow parameters including peak velocity, peak flow rate, net flow rate, and maximum velocity were calculated to compare the performance between different methods using linear regression, intraclass correlation (ICC), and Bland-Altman analyses. RESULTS: Comparisons of the flow measurements at all locations in the phantoms demonstrated an excellent correlation (all R2 ≥ 0.93) and agreement (all ICC ≥ 0.97) with negligible means of differences. In healthy volunteers, a similarly good correlation (all R2 ≥ 0.80) and agreement (all ICC ≥ 0.90) were observed; however, CS RT slightly underestimated the maximum velocities and flow rates (~ 12%). CONCLUSION: The highly accelerated CS RT-PC technique is feasible for the evaluation of flow patterns without requiring breath-holding, and it allows for rapid flow assessment in patients with arrhythmia or poor breath-hold capacity. CLINICAL RELEVANCE STATEMENT: The free-breathing real-time flow MRI technique offers improved spatial and temporal resolutions, as well as the ability to image individual cardiac cycles, resulting in superior image quality compared to the conventional PC technique when imaging patients with arrhythmias, especially those with atrial fibrillation. KEY POINTS: • The highly accelerated prototype CS RT-PC MRI technique with improved temporal resolution by the concept of SVE is feasible for beat-to-beat flow evaluation without requiring breath-holding. • The results of the phantom and in vivo quantitative flow evaluation show the ability of the prototype CS RT-PC technique to obtain reliable flow measurements similarly to the conventional PC MRI. • With less than 12% underestimation, excellent agreements between the two techniques were shown for the measurements of peak velocities and flow rates.


Asunto(s)
Fibrilación Atrial , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Velocidad del Flujo Sanguíneo , Reproducibilidad de los Resultados
14.
J Thorac Imaging ; 39(2): 127-135, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982533

RESUMEN

BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Humanos , Femenino , Masculino , Estudios Retrospectivos , Imagen por Resonancia Cinemagnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Reproducibilidad de los Resultados , Ventrículos Cardíacos , Función Ventricular Izquierda
15.
J Cardiovasc Comput Tomogr ; 18(1): 69-74, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38097408

RESUMEN

BACKGROUND: We sought to compare the degree of maximal stenosis and the rate of invasive coronary angiography (ICA) recommendations in patients who underwent coronary CT angiography (CCTA) with photon-counting detector CT (PCD-CT) versus those who underwent CCTA with whole heart coverage energy-integrating detector CT (EID-CT). METHODS: In our retrospective single-center study, we included consecutive patients with suspected CAD who underwent CCTA performed with either PCD-CT or a 280-slice EID-CT. The degree of coronary stenosis was classified as no CAD, minimal (1-24 â€‹%), mild (25-49 â€‹%), moderate (50-69 â€‹%), severe stenosis (70-99 â€‹%), or occlusion. RESULTS: A total of 812 consecutive patients were included in the analysis, 401 patients scanned with EID-CT and 411 patients with PCD-CT (mean age: 58.4 â€‹± â€‹12.4 years, 45.4 â€‹% female). Despite the higher total coronary artery calcium score (CACS) in the PCD-CT group (10 [interquartile range (IQR) â€‹= â€‹0-152.8] vs 1 [IQR â€‹= â€‹0-94], p â€‹< â€‹0.001), obstructive CAD was more frequently reported in the EID-CT vs PCD-CT group (no CAD: 28.7 â€‹% vs 26.0 â€‹%, minimal: 23.2 â€‹% vs 30.9 â€‹%, mild: 19.7 â€‹% vs 23.4 â€‹%, moderate: 14.5 â€‹% vs 9.7 â€‹%, severe: 11.5 â€‹% vs 8.5 â€‹% and occlusion: 2.5 â€‹% vs 1.5 â€‹%, respectively, p â€‹= â€‹0.025). EID-CT was independently associated with downstream ICA (OR â€‹= â€‹2.76 [95%CI â€‹= â€‹1.58-4.97] p â€‹< â€‹0.001) in the overall patient population, in patients with CACS<400 (OR â€‹= â€‹2.18 [95%CI â€‹= â€‹1.13-4.39] p â€‹= â€‹0.024) and in patients with CACS≥400 (OR â€‹= â€‹3.83 [95%CI â€‹= â€‹1.42-11.05] p â€‹= â€‹0.010). CONCLUSION: In patients who underwent CCTA with PCD-CT the number of subsequent ICAs was lower as compared to patients who were scanned with EID-CT. This difference was greater in patients with extensive coronary calcification.


Asunto(s)
Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Angiografía Coronaria , Estudios Retrospectivos , Constricción Patológica , Estudios Prospectivos , Valor Predictivo de las Pruebas , Derivación y Consulta , Fantasmas de Imagen
16.
Int J Cardiol ; 399: 131684, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38151162

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CCTA)-based fractional flow reserve (CT-FFR) allows for noninvasive determination of the functional severity of anatomic lesions in patients with coronary artery disease. The aim of this study was to intra-individually compare CT-FFR between photon-counting detector (PCD) and conventional energy-integrating detector (EID) CT systems. METHODS: In this single-center prospective study, subjects who underwent clinically indicated CCTA on an EID-CT system were recruited for a research CCTA on PCD-CT within 30 days. Image reconstruction settings were matched as closely as possible between EID-CT (Bv36 kernel, iterative reconstruction strength level 3, slice thickness 0.5 mm) and PCD-CT (Bv36 kernel, quantum iterative reconstruction level 3, virtual monoenergetic level 55 keV, slice thickness 0.6 mm). CT-FFR was measured semi-automatically using a prototype on-site machine learning algorithm by two readers. CT-FFR analysis was performed per-patient and per-vessel, and a CT-FFR ≤ 0.75 was considered hemodynamically significant. RESULTS: A total of 22 patients (63.3 ± 9.2 years; 7 women) were included. Median time between EID-CT and PCD-CT was 5.5 days. Comparison of CT-FFR values showed no significant difference and strong agreement between EID-CT and PCD-CT in the per-vessel analysis (0.88 [0.74-0.94] vs. 0.87 [0.76-0.93], P = 0.096, mean bias 0.02, limits of agreement [LoA] -0.14/0.19, r = 0.83, ICC = 0.92), and in the per-patient analysis (0.81 [0.60-0.86] vs. 0.76 [0.64-0.86], P = 0.768, mean bias 0.02, LoA -0.15/0.19, r = 0.90, ICC = 0.93). All included patients were classified into the same category (CT-FFR > 0.75 vs ≤0.75) with both CT systems. CONCLUSIONS: CT-FFR evaluation is feasible with PCD-CT and it shows a strong agreement with EID-CT-based evaluation when images are similarly reconstructed.


Asunto(s)
Angiografía por Tomografía Computarizada , Reserva del Flujo Fraccional Miocárdico , Humanos , Femenino , Angiografía por Tomografía Computarizada/métodos , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria/métodos , Fantasmas de Imagen
17.
Eur Radiol Exp ; 7(1): 79, 2023 12 12.
Artículo en Inglés | MEDLINE | ID: mdl-38087079

RESUMEN

BACKGROUND: Spleen stiffness measurement (SSM) performed by transient elastography at 100 Hz is a novel technology for the evaluation of portal hypertension in advanced chronic liver disease, but technical aspects are lacking. We aimed to evaluate the intraexamination variability of SSM and to determine the best transient elastography protocol for obtaining robust measurements to be used in clinical practice. METHODS: We analyzed 253 SSM exams with up to 20 scans for each examination, performed between April 2021 and June 2022. All SSM results were evaluated according to different protocols by dividing data into groups of n measurements (from 2 to 19). Considering as reference the median SSM values across all the 20 measurements, we calculated the distribution of the absolute deviations of each protocol from the reference median. This analysis was repeated 1,000 times by resampling the data. Distributions were also stratified by etiology (chronic liver disease versus clinically significant portal hypertension) and different SSM ranges: < 25 kPa, 25-75, and > 75 kPa. RESULTS: Overall, we observed that the spleen stiffness exam had less variability if it exceeded 12 measurements, i.e., absolute deviations ≤ 5 kPa at 95% confidence. For exams with higher SSM values (> 75 kPa), as seen in clinically significant portal hypertension, at least 15 measurements are highly recommendable. CONCLUSIONS: Fifteen scans per examination should be considered for each SSM exam performed at 100 Hz to achieve a low intraexamination variability within a reasonable time in clinical practice. RELEVANCE STATEMENT: Performing at least 15 scans per examination is recommended for 100 Hz SSM in order to achieve a low intraexamination variability, in particular for values > 75 kPa compatible with clinically significant portal hypertension. KEY POINTS: • Spleen stiffness measurement by transient elastography is used for stratification in patients with portal hypertension. • At 100 Hz, this method may have intraexamination variability. • A minimum of 15 scans per examination achieves a low intraexamination variability.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipertensión Portal , Humanos , Bazo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Hipertensión Portal/diagnóstico por imagen
18.
Diagnostics (Basel) ; 13(23)2023 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-38066763

RESUMEN

Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.

19.
Curr Heart Fail Rep ; 20(6): 484-492, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38019324

RESUMEN

PURPOSE OF REVIEW: Cardiac computed tomography (CT) is an established non-invasive imaging tool for the assessment of coronary artery disease. Furthermore, it plays a key role in the preinterventional work-up of patients presenting with structural heart disease. RECENT FINDINGS: CT is the gold standard for preprocedural annular assessment, device sizing, risk determination of annular injury, coronary occlusion or left ventricular outflow tract obstruction, calcification visualization and quantification of the target structure, and prediction of a co-planar fluoroscopic angulation for transcatheter interventions in patients with structural heart disease. It is further a key imaging modality in postprocedural assessment for prosthesis thrombosis, degeneration, or endocarditis. CT plays an integral part in the imaging work-up of novel transcatheter therapies for structural heart disease and postprocedural assessment for prosthesis thrombosis or endocarditis. This review provides a comprehensive overview of the key role of CT in the context of structural heart interventions.


Asunto(s)
Endocarditis , Cardiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Trombosis , Humanos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Válvula Aórtica/cirugía
20.
Eur Radiol Exp ; 7(1): 59, 2023 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-37875769

RESUMEN

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS: An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS: There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS: VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT: Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS: • Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. • Differences in VMI lead to decreased reproducibility for radiomic features. • VMI ≥ 90 keV increased the reproducibility of the radiomic features.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Reproducibilidad de los Resultados , Relación Señal-Ruido , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Miocardio