Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Laryngol Otol ; : 1-5, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38449092

RESUMEN

BACKGROUND: Using Otoplan software, it is possible to measure the cochlea before cochlear implant surgery. Until now, computed tomography (CT) of the cochlea has been necessary for this purpose. The aim of this study was to find out whether measuring the cochlea with magnetic resonance imaging (MRI) using Otoplan is possible with the same accuracy. METHODS: The cochlea of 44 patients of the local cochlear implant centre was measured by Otoplan using high-resolution CT-bone and MRI images, and the determined lengths were compared. RESULTS: No significant difference was found between the cochlear lengths measured, regardless of whether the length measurement was based on a CT or an MRI data set. CONCLUSION: For the determination of cochlear length prior to cochlear implant surgery, MRI images are just as suitable as CT images, therefore CT is not mandatory for length measurement by Otoplan, which could reduce the patient's radiation exposure.

2.
Epilepsia ; 65(5): 1462-1474, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38436479

RESUMEN

OBJECTIVE: Interictal blood-brain barrier dysfunction in chronic epilepsy has been demonstrated in animal models and pathological specimens. Ictal blood-brain barrier dysfunction has been shown in humans in vivo using an experimental quantitative magnetic resonance imaging (MRI) protocol. Here, we hypothesized that interictal blood-brain barrier dysfunction is also present in people with drug-resistant epilepsy. METHODS: Thirty-nine people (21 females, mean age at MRI ± SD = 30 ± 8 years) with drug-resistant epilepsy were prospectively recruited and underwent interictal T1-relaxometry before and after administration of a paramagnetic contrast agent. Likewise, quantitative T1 was acquired in 29 people without epilepsy (12 females, age at MRI = 48 ± 18 years). Quantitative T1 difference maps were calculated and served as a surrogate imaging marker for blood-brain barrier dysfunction. Values of quantitative T1 difference maps inside hemispheres ipsilateral to the presumed seizure onset zone were then compared, on a voxelwise level and within presumed seizure onset zones, to the contralateral side of people with epilepsy and to people without epilepsy. RESULTS: Compared to the contralateral side, ipsilateral T1 difference values were significantly higher in white matter (corrected p < .05), gray matter (uncorrected p < .05), and presumed seizure onset zones (p = .04) in people with epilepsy. Compared to people without epilepsy, significantly higher T1 difference values were found in the anatomical vicinity of presumed seizure onset zones (p = .004). A subgroup of people with hippocampal sclerosis demonstrated significantly higher T1 difference values in the ipsilateral hippocampus and in regions strongly interconnected with the hippocampus compared to people without epilepsy (corrected p < .01). Finally, z-scores reflecting the deviation of T1 difference values within the presumed seizure onset zone were associated with verbal memory performance (p = .02) in people with temporal lobe epilepsy. SIGNIFICANCE: Our results indicate a blood-brain barrier dysfunction in drug-resistant epilepsy that is detectable interictally in vivo, anatomically related to the presumed seizure onset zone, and associated with cognitive deficits.


Asunto(s)
Barrera Hematoencefálica , Epilepsia Refractaria , Imagen por Resonancia Magnética , Humanos , Barrera Hematoencefálica/fisiopatología , Barrera Hematoencefálica/patología , Barrera Hematoencefálica/diagnóstico por imagen , Femenino , Masculino , Adulto , Persona de Mediana Edad , Epilepsia Refractaria/fisiopatología , Epilepsia Refractaria/diagnóstico por imagen , Adulto Joven , Estudios Prospectivos , Epilepsia/fisiopatología , Epilepsia/diagnóstico por imagen
3.
Eur Radiol ; 33(12): 8974-8985, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37368108

RESUMEN

OBJECTIVES: Image-based detection of intralesional fat in focal liver lesions has been established in diagnostic guidelines as a feature indicative of hepatocellular carcinoma (HCC) and associated with a favorable prognosis. Given recent advances in MRI-based fat quantification techniques, we investigated a possible relationship between intralesional fat content and histologic tumor grade in steatotic HCCs. METHODS: Patients with histopathologically confirmed HCC and prior MRI with proton density fat fraction (PDFF) mapping were retrospectively identified. Intralesional fat of HCCs was assessed using an ROI-based analysis and the median fat fraction of steatotic HCCs was compared between tumor grades G1-3 with non-parametric testing. ROC analysis was performed in case of statistically significant differences (p < 0.05). Subgroup analyses were conducted for patients with/without liver steatosis and with/without liver cirrhosis. RESULTS: A total of 57 patients with steatotic HCCs (62 lesions) were eligible for analysis. The median fat fraction was significantly higher for G1 lesions (median [interquartile range], 7.9% [6.0─10.7%]) than for G2 (4.4% [3.2─6.6%]; p = .001) and G3 lesions (4.7% [2.8─7.8%]; p = .036). PDFF was a good discriminator between G1 and G2/3 lesions (AUC .81; cut-off 5.8%, sensitivity 83%, specificity 68%) with comparable results in patients with liver cirrhosis. In patients with liver steatosis, intralesional fat content was higher than in the overall sample, with PDFF performing better in distinguishing between G1 and G2/3 lesions (AUC .92; cut-off 8.8%, sensitivity 83%, specificity 91%). CONCLUSIONS: Quantification of intralesional fat using MRI PDFF mapping allows distinction between well- and less-differentiated steatotic HCCs. CLINICAL RELEVANCE: PDFF mapping may help optimize precision medicine as a tool for tumor grade assessment in steatotic HCCs. Further investigation of intratumoral fat content as a potential prognostic indicator of treatment response is encouraged. KEY POINTS: • MRI proton density fat fraction mapping enables distinction between well- (G1) and less- (G2 and G3) differentiated steatotic hepatocellular carcinomas. • In a retrospective single-center study with 62 histologically proven steatotic hepatocellular carcinomas, G1 tumors showed a higher intralesional fat content than G2 and G3 tumors (7.9% vs. 4.4% and 4.7%; p = .004). • In liver steatosis, MRI proton density fat fraction mapping was an even better discriminator between G1 and G2/G3 steatotic hepatocellular carcinomas.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Enfermedad del Hígado Graso no Alcohólico , Humanos , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Hígado/patología , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Estudios Retrospectivos , Protones , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Cirrosis Hepática/patología
4.
J Clin Med ; 12(9)2023 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-37176498

RESUMEN

Osteomyelitis (OM) remains one of the most feared complications in bone surgery and trauma. Its diagnosis remains a major challenge due to lack of guidelines. The aim of this study was to prospectively analyze the value of the most common and available diagnostic tools and to establish an OM score to derive treatment recommendations. All patients with suspected OM were included in a prospective pilot study. All patients underwent blood sampling for C-reactive protein and white blood cell count analysis. Magnetic resonance imaging (MRI), and microbiologic and histopathologic samples, were taken from representative sites of initial debridement. All patients were treated according to their OM test results and followed for at least one year. Subsequently, the value of individual or combined diagnostic tools was analyzed in patients with confirmed OM and in patients in whom OM was ruled out. Based on these findings, an OM score was developed that included MRI, microbiology, and histopathology. The score identified all control patients and all but one OM patient, resulting in a correct diagnosis of 93.3%, which was validated in a second independent larger cohort. This was the first study to analyze the value of the most commonly used tools to diagnose OM. The proposed OM score provides a simple scoring system to safely interpret test results with high accuracy.

5.
J Am Heart Assoc ; 12(9): e029492, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-37119085

RESUMEN

Background The objective of this study was to investigate cardiac abnormalities in intensive care unit (ICU) survivors of critical illness and to determine whether temporary acute kidney injury (AKI) is associated with more pronounced findings on cardiovascular magnetic resonance. Methods and Results There were 2175 patients treated in the ICU (from 2015 until 2021) due to critical illness who were screened for study eligibility. Post-ICU patients without known cardiac disease were prospectively recruited from March 2021 to May 2022. Participants underwent cardiovascular magnetic resonance including assessment of cardiac function, myocardial edema, late gadolinium enhancement, and mapping including extracellular volume fraction. Student t test, Mann-Whitney U test, and χ2 tests were used. There were 48 ICU survivors (46±15 years of age, 28 men, 29 with AKI and continuous kidney replacement therapy, and 19 without AKI) and 20 healthy controls who were included. ICU survivors had elevated markers of myocardial fibrosis (T1: 995±31 ms versus 957±21 ms, P<0.001; extracellular volume fraction: 24.9±2.5% versus 22.8±1.2%, P<0.001; late gadolinium enhancement: 1% [0%-3%] versus 0% [0%-0%], P<0.001), more frequent focal late gadolinium enhancement lesions (21% versus 0%, P=0.03), and an impaired left ventricular function (eg, ejection fraction: 57±6% versus 60±5%, P=0.03; systolic longitudinal strain: 20.3±3.7% versus 23.1±3.5%, P=0.004) compared with healthy controls. ICU survivors with AKI had higher myocardial T1 (1002±33 ms versus 983±21 ms; P=0.046) and extracellular volume fraction values (25.6±2.6% versus 23.9±1.9%; P=0.02) compared with participants without AKI. Conclusions ICU survivors of critical illness without previously diagnosed cardiac disease had distinct abnormalities on cardiovascular magnetic resonance including signs of myocardial fibrosis and systolic dysfunction. Findings were more abnormal in participants who experienced AKI with necessity of continuous kidney replacement therapy during their ICU stay. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05034588.


Asunto(s)
Lesión Renal Aguda , Cardiomiopatías , Cardiopatías Congénitas , Masculino , Humanos , Adulto , Medios de Contraste , Enfermedad Crítica , Gadolinio , Imagen por Resonancia Cinemagnética , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Cardiomiopatías/patología , Fibrosis , Espectroscopía de Resonancia Magnética , Sobrevivientes , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/etiología
6.
Invest Radiol ; 58(3): 209-215, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36070533

RESUMEN

OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time. MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates. RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants. CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.


Asunto(s)
Imagen por Resonancia Magnética , Neoplasias de la Próstata , Humanos , Masculino , Persona de Mediana Edad , Anciano , Imagen por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Neoplasias de la Próstata/diagnóstico por imagen , Relación Señal-Ruido , Artefactos
7.
Eur Heart J Cardiovasc Imaging ; 24(7): 949-960, 2023 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-36423215

RESUMEN

AIMS: The exact role of portal hypertension in cirrhotic cardiomyopathy remains unclear, and it is uncertain whether cardiac abnormalities also occur in non-cirrhotic portal hypertension (NCPH). This magnetic resonance imaging (MRI) study aimed to evaluate the presence of subclinical myocardial dysfunction, oedema, and fibrosis in NCPH. METHODS AND RESULTS: In this prospective study (2018-2022), participants underwent multiparametric abdominal and cardiac MRI including assessment of cardiac function, myocardial oedema, late gadolinium enhancement (LGE), and abdominal and cardiac mapping [T1 and T2 relaxation times, extracellular volume fraction (ECV)]. A total of 111 participants were included [44 participants with NCPH (48 ± 15 years; 23 women), 47 cirrhotic controls, and 20 healthy controls]. The cirrhotic group was dichotomized (Child A vs. Child B/C). NCPH participants demonstrated a more hyperdynamic circulation compared with healthy controls (cardiac index: 3.7 ± 0.6 vs. 3.2 ± 0.8 L/min/m², P = 0.004; global longitudinal strain: -27.3 ± 4.6 vs. -24.6 ± 3.5%, P = 0.022). The extent of abnormalities indicating myocardial fibrosis and oedema in NCPH was comparable with Child A cirrhosis (e.g. LGE presence: 32 vs. 33 vs. 69%, P = 0.004; combined T1 and T2 elevations: 46 vs. 27 vs. 69%, P = 0.017; NCPH vs. Child A vs. Child B/C). Correlations between splenic T1 and myocardial T1 values were found (r = 0.41; P = 0.007). Splenic T1 values were associated with the presence of LGE (odds ratio, 1.010; 95% CI: 1.002, 1.019; P = 0.013). CONCLUSION: MRI parameters of myocardial fibrosis and oedema were altered in participants with NCPH to a similar extent as in compensated cirrhosis and were associated with splenic markers of portal hypertension, indicating specific portal hypertensive cardiomyopathy.


Asunto(s)
Cardiomiopatías , Hipertensión Portal , Niño , Humanos , Femenino , Medios de Contraste , Estudios Prospectivos , Gadolinio , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/etiología , Fibrosis , Imagen por Resonancia Magnética/métodos , Miocardio/patología , Edema/diagnóstico por imagen , Edema/etiología , Edema/patología , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/etiología , Hipertensión Portal/patología , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas
8.
J Cardiovasc Magn Reson ; 24(1): 55, 2022 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-36384752

RESUMEN

BACKGROUND: To evaluate the great vessels in young children with complex congenital heart disease (CHD) using non-contrast cardiovascular magnetic resonance angiography (CMRA) based on three-dimensional relaxation-enhanced angiography without contrast (REACT) in comparison to contrast-enhanced steady-state CMRA. METHODS: In this retrospective study from April to July 2021, respiratory- and electrocardiogram-gated native REACT CMRA was compared to contrast-enhanced single-phase steady-state CMRA in children with CHD who underwent CMRA at 3T under deep sedation. Vascular assessment included image quality (1 = non-diagnostic, 5 = excellent), vessel diameter, and diagnostic findings. For statistical analysis, paired t-test, Pearson correlation, Bland-Altman analysis, Wilcoxon test, and intraclass correlation coefficients (ICC) were applied. RESULTS: Thirty-six young children with complex CHD (median 4 years, interquartile range, 2-5; 20 males) were included. Native REACT CMRA was obtained successfully in all patients (mean scan time: 4:22 ± 1:44 min). For all vessels assessed, diameters correlated strongly between both methods (Pearson r = 0.99; bias = 0.04 ± 0.61 mm) with high interobserver reproducibility (ICC: 0.99 for both CMRAs). Native REACT CMRA demonstrated comparable overall image quality to contrast-enhanced CMRA (3.9 ± 1.0 vs. 3.8 ± 0.9, P = 0.018). With REACT CMRA, better image quality was obtained at the ascending aorta (4.8 ± 0.5 vs. 4.3 ± 0.8, P < 0.001), coronary roots (e.g., left: 4.1 ± 1.0 vs. 3.3 ± 1.1, P = 0.001), and inferior vena cava (4.6 ± 0.5 vs. 3.2 ± 0.8, P < 0.001). In all patients, additional vascular findings were assessed equally with native REACT CMRA and the contrast-enhanced reference standard (n = 6). CONCLUSION: In young children with complex CHD, REACT CMRA can provide gadolinium-free high image quality, accurate vascular measurements, and equivalent diagnostic quality compared to standard contrast-enhanced CMRA.


Asunto(s)
Cardiopatías Congénitas , Angiografía por Resonancia Magnética , Masculino , Humanos , Niño , Preescolar , Angiografía por Resonancia Magnética/métodos , Estudios Retrospectivos , Reproducibilidad de los Resultados , Medios de Contraste , Valor Predictivo de las Pruebas , Cardiopatías Congénitas/diagnóstico por imagen
9.
Radiol Cardiothorac Imaging ; 4(3): e210318, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35833169

RESUMEN

Purpose: To evaluate the diagnostic performance of layer-specific cardiac MRI feature-tracking (FT) strain analysis in patients with acute myocarditis. Materials and Methods: Seventy patients (mean age, 43 years ± 19 [SD]; 46 men) with clinically defined acute myocarditis and 42 healthy controls who underwent cardiac MRI from March 2014 to November 2018 were retrospectively analyzed. FT-based left ventricular peak systolic global longitudinal strain (GLS) and global circumferential strain (GCS) were assessed at subendocardial, midmyocardial, and subepicardial layers. The 2018 Lake Louise criteria (LLC) were assessed. Patients with myocarditis were dichotomized into two groups: those with preserved and those with reduced ejection fraction. For statistical analysis, unpaired t test, one-way analysis of variance, Pearson correlation, and receiver operating characteristic analysis were used. Results: GLS and GCS values of all layers (eg, midmyocardial GCS: -21.3% ± 5.5 vs -28.0% ± 4.3; P < .001) were impaired in patients with myocarditis compared with controls. Only subepicardial GLS (-20.0% ± 3.3 vs -17.5% ± 3.3; P < .001) and midmyocardial GCS values (-28.0% ± 4.3 vs -23.1% ± 4.3; P < .001) could differentiate between controls and patients with preserved ejection fraction. Midmyocardial GCS correlated with inflammatory myocardial parameters (eg, late gadolinium enhancement percentage, r = 0.48, P < .001). Midmyocardial GCS (area under the receiver operating characteristic curve [AUC], 0.82) and subepicardial GLS (AUC, 0.77) had the highest diagnostic performance for acute myocarditis diagnosis (P < .05 against all other strain parameters). The diagnostic performance of the 2018 LLC was significantly improved by inclusion of these two strain parameters (AUC, 0.92 vs 0.97; P = .04). Conclusion: Diagnostic performance of cardiac MRI FT strain was different between myocardial layers in acute myocarditis, with midmyocardial GCS and subepicardial GLS providing the highest diagnostic performance.Keywords: MRI, Cardiac, Heart, Left Ventricle, Inflammation, Tissue Characterization, MR-Functional Imaging, Feature-Tracking Strain, Acute Myocarditis Supplemental material is available for this article. © RSNA, 2022.

10.
Sci Rep ; 12(1): 9422, 2022 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-35676399

RESUMEN

We aimed to investigate the diagnostic utility of MRI extracellular volume fraction (ECV) for the assessment of liver cirrhosis severity as defined by Child-Pugh class. In this retrospective study, 90 patients (68 cirrhotic patients and 22 controls), who underwent multiparametric liver MRI, were identified. Hepatic T1 relaxation times and ECV were assessed. Clinical scores of liver disease severity were calculated. One-way analysis of variance (ANOVA) followed by Tukey's multiple comparison test, Spearman's correlation coefficient, and receiver operating characteristic (ROC) analysis were used for statistical analysis. In cirrhotic patients, hepatic native T1 increased depending on Child-Pugh class (620.5 ± 78.9 ms (Child A) vs. 666.6 ± 73.4 ms (Child B) vs. 828.4 ± 91.2 ms (Child C), P < 0.001). ECV was higher in cirrhotic patients compared to the controls (40.1 ± 11.9% vs. 25.9 ± 4.5%, P < 0.001) and increased depending of Child-Pugh class (33.3 ± 6.0% (Child A) vs. 39.6 ± 4.9% (Child B) vs. 52.8 ± 1.2% (Child C), P < 0.001). ECV correlated with Child-Pugh score (r = 0.64, P < 0.001). ECV allowed differentiating between Child-Pugh classes A and B, and B and C with an AUC of 0.785 and 0.944 (P < 0.001, respectively). The diagnostic performance of ECV for differentiating between Child-Pugh classes A and B, and B and C was higher compared to hepatic native T1 (AUC: 0.651 and 0.910) and MELD score (AUC: 0.740 and 0.795) (P < 0.05, respectively). MRI-derived ECV correlated with Child-Pugh score and had a high diagnostic performance for the discrimination of different Child-Pugh classes. ECV might become a valuable non-invasive biomarker for the assessment of liver cirrhosis severity.


Asunto(s)
Cirrosis Hepática , Imagen por Resonancia Magnética , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Curva ROC , Estudios Retrospectivos
11.
Invest Radiol ; 57(10): 689-695, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35510876

RESUMEN

OBJECTIVE: High spatial and temporal resolution contrast-enhanced magnetic resonance angiography (MRA) with gadolinium-based contrast agents (GBCAs) at standard dose offers both detailed anatomic information on both arterial and venous vessels and hemodynamic characteristics. Several preclinical and clinical dynamic 3-dimensional (3D) MRA studies that focused on arterial vessels only proposed that high image quality may also be achieved with significantly reduced GBCA doses, calling into question the need to use standard doses. A systematic analysis of GBCA doses and resulting image quality for both arteries and veins has not yet been performed. The purpose of this study was therefore to systematically analyze dose-dependent vascular enhancements in dynamic 3D-MRA of the thoracoabdominal vasculature at 1.5 T in an animal model to determine the optimal contrast agent protocol for optimized vascular assessment. MATERIALS AND METHODS: The vascular enhancement in thoracoabdominal dynamic 3D-MRA (time-resolved angiography with interleaved stochastic trajectories, TWIST at 1.5 T) was interindividually and intraindividually compared in 5 anesthetized Göttingen minipigs using gadobutrol at the standard dose (0.1 mmol/kg body weight, ie, 0.1 mL/kg) and at reduced doses (0.08, 0.06, 0.04, 0.02 mmol/kg) in a randomized order. All injections were performed at 2 mL/s followed by 20 mL saline. Images were quantitatively analyzed, measuring signal intensities in 5 regions that covered the passage of the GBCA through the body at different representative stages of circulation (pulmonary, arterial, and venous system). The evaluation of GBCA dose-dependent signal intensity changes in the different vascular regions was performed by linear regression analysis.The qualitative image analysis of dynamic 3D-MRA by 3 independent radiologists included the visibility of 25 arterial and venous vessel segments at different stages of GBCA passage. Possible quality losses were statistically tested by comparing image quality ratings at the reduced dose with that of the standard dose using Friedman test followed by Dunn post hoc test for multiple comparison. Significance was stated at P < 0.05. RESULTS: Quantitative analysis revealed shorter time-to-peak intervals and bolus durations in line with decreasing GBCA dose and volume in all vessels. Although the peak signal was almost independent of the administered GBCA dose at the level of the pulmonary trunk, a linear signal decrease in the abdominal aorta ( r2 = 0.96), the renal arteries ( r2 = 0.99), the inferior vena cava ( r2 = 0.99), and the portal vein ( r2 = 0.97) was observed. Cumulative analysis of arterial segments revealed significantly lower image quality at doses below 40% of the standard dose, whereas in venous segments, significantly lower image quality was observed at doses below 60% of the standard dose. CONCLUSIONS: In dynamic 3D-MRA at 1.5 T, dose reduction leads to a signal loss that is most pronounced in the venous system and results in significantly lower image quality according to the dose and vessels of interest. Careful dose reduction is thus required according to the specific diagnostic needs. For dynamic 3D-MRA of the arterial and venous system, GBCA doses of at least 60% of the standard dose up to the full dose are preferable, whereas 40% of the standard dose seems feasible if only the arterial system is to be imaged.


Asunto(s)
Medios de Contraste , Angiografía por Resonancia Magnética , Animales , Reducción Gradual de Medicamentos , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Porcinos , Porcinos Enanos
12.
Rofo ; 194(9): 1003-1011, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35272355

RESUMEN

PURPOSE: To evaluate cardiac MRI characteristics in patients with suspected hypersensitivity myocarditis following mRNA COVID-19 vaccination. MATERIALS AND METHODS: Patients clinically suspected of acute myocarditis after COVID-19 vaccination were retrospectively analyzed and compared against a healthy control group. Cardiac MRI protocol included parameters such as T1 and T2 relaxation times, extracellular volume (ECV), T2 signal intensity ratio, and late gadolinium enhancement (LGE). Lymph node size was assessed in the patient group on the injection side. Student t-test, analyses of variance (ANOVA) with Tukey post-hoc test, and χ2 test were used for statistical analysis. RESULTS: 20 patients with clinically suspected post-vaccine myocarditis (28 ±â€Š12 years; 12 men) and 40 controls (31 ±â€Š11 years; 25 men) were evaluated. According to the 2018 Lake Louise criteria (LLC), patients with clinically suspected myocarditis were further subdivided into an LLC-positive group (n = 9) and an LLC-negative group (n = 11). The mean time of symptom onset after vaccination was 1.1 ±â€Š1.2 days (LLC-positive) and 6.5 ±â€Š9.2 days (LLC-negative). Group differences in inflammatory variables between myocarditis patients and control subjects were more pronounced in the LLC-positive group (e. g., T1 relaxation time: 1041 ±â€Š61 ms [LLC positive] vs. 1008 ±â€Š79 ms [LLC-negative] vs. 970 ±â€Š25 ms [control]; p <.001; or T2 signal intensity ratio 2.0 ±â€Š0.3 vs. 1.6 ±â€Š0.3 [LLC-negative] and vs. 1.6 ±â€Š0.3 [control], p = .012). LLC-positive patients were significantly faster in receiving an MRI after initial symptom onset (8.8 ±â€Š6.1 days vs. 52.7 ±â€Š33.4 days; p = .001) and had higher troponin T levels (3938 ±â€Š5850 ng/l vs. 9 ±â€Š11 ng/l; p <.001). LGE lesions were predominantly located at the subepicardium of the lateral wall. Axillary lymphadenopathy was more frequent in the LLC-positive group compared to the LLC-negative group (8/9 [89 %] vs. 0/11 [0 %], p < 0.001). CONCLUSION: Vaccine-induced myocarditis should be considered in patients with acute symptom onset after mRNA vaccination, especially if elevated serum troponin T is observed. Imaging findings of vaccine-induced myocarditis are similar to virus-induced myocarditis, allowing for the use of the Lake Louise Criteria for diagnostic purposes. KEY POINTS: · Vaccine-induced hypersensitivity myocarditis can be confirmed with cardiac MRI. · Especially patients with sudden onset of symptoms and elevated serum troponin T had positive cardiac MRI findings. · Cardiac MRI characteristics of vaccine-induced myocarditis are similar to those in virus-induced myocarditis. CITATION FORMAT: · Kravchenko D, Isaak A, Mesropyan N et al. Cardiac MRI in Suspected Acute Myocarditis After COVID-19 mRNA Vaccination. Fortschr Röntgenstr 2022; 194: 1003 - 1011.


Asunto(s)
COVID-19 , Miocarditis , Adolescente , Adulto , Vacunas contra la COVID-19 , Medios de Contraste , Femenino , Gadolinio , Humanos , Imagen por Resonancia Magnética , Masculino , Valor Predictivo de las Pruebas , ARN Mensajero , Estudios Retrospectivos , Troponina T , Vacunación , Adulto Joven
13.
Diagnostics (Basel) ; 12(2)2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35204469

RESUMEN

This study aimed to evaluate the diagnostic and prognostic value of cardiac magnetic resonance in acute peripartum cardiomyopathy (PPCM). A total of 17 patients with PPCM in the acute stage and 15 healthy controls were retrospectively analyzed regarding myocardial function, edema, late gadolinium enhancement (LGE), and T1 and T2 mappings (T1, T2). Echocardiographic follow-ups were performed. Functional recovery was defined as a left ventricular ejection fraction (LVEF) of ≥50%. Patients with PPCM displayed biventricular dysfunction with reduced myocardial strain parameters and left ventricular and atrial dilatation, as well as diffuse myocardial edema (T2 signal intensity ratio: 2.10 ± 0.34 vs. 1.58 ± 0.21, p < 0.001; T1: 1070 ± 51 ms vs. 980 ± 28 ms, p = 0.001; T2: 63 ± 5 ms vs. 53 ± 2 ms, p < 0.001). Visual myocardial edema was present in 10 patients (59%). LGE was positive in 2 patients (12%). A total of 13 patients (76%) showed full LVEF recovery. The absence of visual myocardial edema and impairment of strain parameters were associated with delayed LVEF recovery. Multivariable Cox regression analysis revealed global longitudinal strain as an independent prognostic factor for LVEF recovery. In conclusion, biventricular systolic dysfunction with diffuse myocardial edema seems to be present in acute PPCM. Myocardial edema and strain may have prognostic value for LVEF recovery.

14.
Invest Radiol ; 57(7): 470-477, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35136004

RESUMEN

OBJECTIVE: Robust dynamic contrast-enhanced T1-weighted images are crucial for accurate detection and categorization of focal liver lesions in liver/abdominal magnetic resonance imaging (MRI). As optimal dynamic imaging usually requires multiple breath-holds, its inherent susceptibility to motion artifacts frequently results in degraded image quality in incompliant patients. Because free-breathing imaging may overcome this drawback, the intention of this study was to evaluate a dynamic MRI sequence acquired during free breathing using the variable density, elliptical centric golden angle radial stack-of-stars radial sampling scheme, which so far has not been implemented in 4-dimensional applications. MATERIALS AND METHODS: In a prospective pilot study, 27 patients received a routine abdominal MRI protocol including the prototype free-breathing sequence (4DFreeBreathing) for dynamic imaging. This enables more convenient and faster reconstruction through variable density, elliptical centric golden angle radial stack-of-stars without the use of additional reconstruction hardware, and even higher motion robustness through soft-gating. A standard breath-hold sequence performed subsequently served as reference standard. Of the continuous dynamic data sets, each dynamic phase was analyzed regarding image quality, motion artifacts and vessel conspicuity using 5-point Likert scales. Furthermore, correct timing of the late arterial phase was compared with the preexaminations. RESULTS: 4DFreeBreathing delivered motion-free dynamic images with high temporal resolution in each subject. Overall image quality scores were rated good or excellent for 4DFreeBreathing and the gold standard without significant differences (P = 0.34). There were significantly less motion artifacts in the 4DFreeBreathing sequence (P < 0.0001), whereas vessel conspicuity in each dynamic phase was comparable for both groups (P = 0.45, P > 0.99, P = 0.22, respectively). Correct timing of the late arterial phase could be achieved in 27 of 27 (100%) examinations using 4DFreeBreathing versus 35 of 53 (66%) preexaminations using gold standard (P < 0.001). CONCLUSION: The benefit of convenient and fast image reconstruction combined with the superiority in motion robustness and timing compared with standard breath hold sequences renders 4DFreeBreathing an attractive alternative to existing free-breathing techniques in dynamic liver MRI.


Asunto(s)
Medios de Contraste , Aumento de la Imagen , Artefactos , Estudios de Factibilidad , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Proyectos Piloto , Estudios Prospectivos , Respiración
15.
Diagnostics (Basel) ; 11(12)2021 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-34943551

RESUMEN

Previous studies suggest an impact of body composition on outcome in melanoma patients. We aimed to determine the prognostic value of CT-based body composition assessment in patients receiving immune checkpoint inhibitor therapy for treatment of metastatic disease using a deep learning approach. One hundred seven patients with staging CT examinations prior to initiation of checkpoint inhibition between January 2013 and August 2019 were retrospectively evaluated. Using an automated deep learning-based body composition analysis pipeline, parameters for estimation of skeletal muscle mass (skeletal muscle index, SMI) and adipose tissue compartments (visceral adipose tissue index, VAI; subcutaneous adipose tissue index, SAI) were derived from staging CT. The cohort was binarized according to gender-specific median cut-off values. Patients below the median were defined as having low SMI, VAI, or SAI, respectively. The impact on outcome was assessed using the Kaplan-Meier method with log-rank tests. A multivariable logistic regression model was built to test the impact of body composition parameters on 3-year mortality. Patients with low SMI displayed significantly increased 1-year (25% versus 9%, p = 0.035), 2-year (32% versus 13%, p = 0.017), and 3-year mortality (38% versus 19%, p = 0.016). No significant differences with regard to adipose tissue compartments were observed (3-year mortality: VAI, p = 0.448; SAI, p = 0.731). On multivariable analysis, low SMI (hazard ratio (HR), 2.245; 95% confidence interval (CI), 1.005-5.017; p = 0.049), neutrophil-to-lymphocyte ratio (HR, 1.170; 95% CI, 1.076-1.273; p < 0.001), and Karnofsky index (HR, 0.965; 95% CI, 0.945-0.985; p = 0.001) remained as significant predictors of 3-year mortality. Lowered skeletal muscle index as an indicator of sarcopenia was associated with worse outcome in patients with metastatic melanoma receiving immune checkpoint inhibitor therapy.

16.
J Cardiovasc Magn Reson ; 23(1): 117, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-34689811

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance angiography (CMRA) is a non-invasive imaging modality of choice in pediatric patients with congenital heart disease (CHD). This study was aimed to evaluate the diagnostic utility of a respiratory- and electrocardiogram-gated steady-state CMRA with modified Dixon (mDixon) fat suppression technique and compressed sensing in comparison to standard first-pass CMRA in pediatric patients with CHD at 3 T. METHODS: In this retrospective single center study, pediatric CHD patients who underwent CMR with first-pass CMRA followed by mDixon steady-state CMRA at 3 T were analyzed. Image quality using a Likert scale from 5 (excellent) to 1 (non-diagnostic) and quality of fat suppression were assessed in consensus by two readers. Blood-to-tissue contrast and quantitative measurements of the thoracic vasculature were assessed separately by two readers. CMRA images were reevaluated by two readers for additional findings, which could be identified only on either one of the CMRA types. Paired Student t test, Wilcoxon test, and intraclass correlation coefficients (ICCs) were used for statistical analysis. RESULTS: 32 patients with CHD (3.3 ± 1.7 years, 13 female) were included. Overall image quality of steady-state mDixon CMRA was higher compared to first-pass CMRA (4.5 ± 0.5 vs. 3.3 ± 0.5; P < 0.001). Blood-to-tissue contrast ratio of steady-state mDixon CMRA was comparable to first-pass CMRA (7.85 ± 4.75 vs. 6.35 ± 2.23; P = 0.133). Fat suppression of steady-state mDixon CMRA was perfect in 30/32 (94%) cases. Vessel diameters were greater in first-pass CMRA compared to steady-state mDixon CMRA with the greatest differences at the level of pulmonary arteries and veins (e.g., right pulmonary artery for reader 1: 10.4 ± 2.4 vs. 9.9 ± 2.3 mm, P < 0.001). Interobserver agreement was higher for steady-state mDixon CMRA for all measurements compared to first-pass CMRA (ICCs > 0.92). In 9/32 (28%) patients, 10 additional findings were identified on mDixon steady-state CMRA (e.g., partial anomalous venous return, abnormalities of coronary arteries, subclavian artery stenosis), which were not depicted using first-pass CMRA. CONCLUSIONS: Steady-state mDixon CMRA offers a robust fat suppression, a high image quality, and diagnostic utility for the assessment of the thoracic vasculature in pediatric CHD patients.


Asunto(s)
Cardiopatías Congénitas , Angiografía por Resonancia Magnética , Niño , Medios de Contraste , Vasos Coronarios , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Valor Predictivo de las Pruebas , Estudios Retrospectivos
18.
Pediatr Radiol ; 51(13): 2470-2480, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34435226

RESUMEN

BACKGROUND: The diagnostic value of cardiac magnetic resonance imaging (MRI) employing the 2018 Lake Louise criteria in pediatric and adolescent patients with acute myocarditis is undefined. OBJECTIVE: To evaluate the diagnostic value of the Lake Louise criteria in pediatric and adolescent patients with suspected acute myocarditis and to show the utility of cardiac MRI for follow-up in this patient cohort. MATERIALS AND METHODS: Forty-three patients (age range: 8-21 years) with suspected acute myocarditis and 13 control patients who underwent cardiac MRI were retrospectively analyzed. T2-weighted and late gadolinium enhancement imaging were performed in all patients. T1 and T2 mapping were available in 26/43 patients (60%). The Lake Louise criteria were assessed. In 27/43 patients (63%), cardiac MRI follow-up was available. Receiver operating characteristic analysis, Pearson's correlation coefficient and paired Student's t-test were used for statistical analysis. RESULTS: In the total cohort, the Lake Louise criteria achieved a sensitivity of 86% (95% confidence interval [CI]: 72-95%) and a specificity of 100% (95% CI: 79-100%) for the diagnosis of acute myocarditis. In the subgroup of patients with available mapping parameters, the diagnostic performance of the Lake Louise criteria was higher when mapping parameters were implemented into the score (area under the receiver operating characteristic curve: 0.944 vs. 0.870; P=0.033). T2 relaxation times were higher in patients with admission to the intermediate care unit and were associated with the length of intermediate care unit stay (r=0.879, P=0.049). Cardiac MRI markers of active inflammation decreased on follow-up examinations (e.g., T1 relaxation times: 1,032±39 ms vs. 975±33 ms, P<0.001; T2 relaxation times: 58±5 ms vs. 54±5 ms, P=0.003). CONCLUSION: The Lake Louise criteria have a high diagnostic performance for the diagnosis of acute myocarditis and are a valuable tool for follow-up in pediatric and adolescent patients. The mapping techniques enhance the diagnostic performance of the 2018 Lake Louise criteria.


Asunto(s)
Miocarditis , Enfermedad Aguda , Adolescente , Adulto , Niño , Medios de Contraste , Gadolinio , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Miocarditis/diagnóstico por imagen , Estudios Retrospectivos , Adulto Joven
19.
J Cardiovasc Magn Reson ; 23(1): 91, 2021 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-34275486

RESUMEN

BACKGROUND: To evaluate a non-contrast respiratory- and electrocardiogram-gated 3D cardiovascular magnetic resonance angiography (CMRA) based on magnetization-prepared Dixon method (relaxation-enhanced angiography without contrast and triggering, REACT) for the assessment of the thoracic vasculature in congenital heart disease (CHD) patients. METHODS: 70 patients with CHD (mean 28 years, range: 10-65 years) were retrospectively identified in this single-center study. REACT-CMRA was applied with respiratory- and cardiac-gating. Image quality (IQ) of REACT-CMRA was compared to standard non-gated multi-phase first-pass-CMRA and respiratory- and electrocardiogram-gated steady-state-CMRA. IQ of different vessels of interest (ascending aorta, left pulmonary artery, left superior pulmonary vein, right coronary ostium, coronary sinus) was independently assessed by two readers on a five-point Likert scale. Measurements of vessel diameters were performed in predefined anatomic landmarks (ascending aorta, left pulmonary artery, left superior pulmonary vein). Both readers assessed artifacts and vascular abnormalities. Friedman test, chi-squared test, and Bland-Altman method were used for statistical analysis. RESULTS: Overall IQ score of REACT-CMRA was higher compared to first-pass-CMRA (3.5 ± 0.4 vs. 2.7 ± 0.4, P < 0.001) and did not differ from steady-state-CMRA (3.5 ± 0.4 vs. 3.5 ± 0.6, P = 0.99). Non-diagnostic IQ of the defined vessels of interest was observed less frequently on REACT-CMRA (1.7 %) compared to steady-state- (4.3 %, P = 0.046) or first-pass-CMRA (20.9 %, P < 0.001). Close agreements in vessel diameter measurements were observed between REACT-CMRA and steady-state-CMRA (e.g. ascending aorta, bias: 0.38 ± 1.0 mm, 95 % limits of agreement (LOA): - 1.62-2.38 mm). REACT-CMRA showed high intra- (bias: 0.04 ± 1.0 mm, 95 % LOA: - 1.9-2.0 mm) and interobserver (bias: 0.20 ± 1.1 mm, 95 % LOA: - 2.0-2.4 mm) agreements regarding vessel diameter measurements. Fat-water separation artifacts were observed in 11/70 (16 %) patients on REACT-CMRA but did not limit diagnostic utility. Six vascular abnormalities were detected on REACT-CMRA that were not seen on standard contrast-enhanced CMRA. CONCLUSIONS: Non-contrast-enhanced cardiac-gated REACT-CMRA offers a high diagnostic quality for assessment of the thoracic vasculature in CHD patients.


Asunto(s)
Cardiopatías Congénitas , Angiografía por Resonancia Magnética , Medios de Contraste , Angiografía Coronaria , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
20.
Invest Radiol ; 56(11): 680-691, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34324464

RESUMEN

ABSTRACT: Whole-body magnetic resonance imaging (MRI) systems with a field strength of 3 T have been offered by all leading manufacturers for approximately 2 decades and are increasingly used in clinical diagnostics despite higher costs. Technologically, MRI systems operating at 3 T have reached a high standard in recent years, as well as the 1.5-T devices that have been in use for a longer time. For modern MRI systems with 3 T, more complexity is required, especially for the magnet and the radiofrequency (RF) system (with multichannel transmission). Many clinical applications benefit greatly from the higher field strength due to the higher signal yield (eg, imaging of the brain or extremities), but there are also applications where the disadvantages of 3 T might outweigh the advantages (eg, lung imaging or examinations in the presence of implants). This review describes some technical features of modern 1.5-T and 3-T whole-body MRI systems, and reports on the experience of using both types of devices in different clinical settings, with all sections written by specialist radiologists in the respective fields.This first part of the review includes an overview of the general physicotechnical aspects of both field strengths and elaborates the special conditions of diffusion imaging. Many relevant aspects in the application areas of musculoskeletal imaging, abdominal imaging, and prostate diagnostics are discussed.


Asunto(s)
Imagen por Resonancia Magnética , Imagen de Cuerpo Entero , Encéfalo/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...