Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Osteoporos Sarcopenia ; 10(2): 78-83, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39035229

RESUMEN

Objectives: Evaluation of sarcopenia from computed tomography (CT) is often based on measuring skeletal muscle area on a single transverse slice. Automatic segmentation of muscle volume has a lower variance and may be a better proxy for the total muscle volume than single-slice areas. The aim of the study was to determine which abdominal and thoracic anatomical volumes were best at predicting the total muscle volume. Methods: A cloud-based artificial intelligence tool (recomia.org) was used to segment all skeletal muscle of the torso of 994 patients who had performed whole-torso CT 2008-2020 for various clinical indications. Linear regression models for several anatomical volumes and single-slice areas were compared with regard to predicting the total torso muscle volume. Results: The muscle volume from the tip of the coccyx and 25 cm cranially was the best of the abdominal volumes and was significantly better than the L3 slice muscle area (R2 0.935 vs 0.830, P < 0.0001). For thoracic volumes, the muscle volume between the top of the sternum to the lower bound of the Th12 vertebra showed the best correlation with the total volume, significantly better than the Th12 slice muscle area (R2 0.892 vs 0.775, P < 0.0001). Adjusting for body height improved the correlation slightly for all measurements but did not significantly change the ordering. Conclusions: We identified muscle volumes that can be reliably segmented by automated image analysis which is superior to single slice areas in predicting total muscle volume.

2.
Scand J Urol ; 59: 90-97, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698545

RESUMEN

OBJECTIVE: To evaluate whether artificial intelligence (AI) based automatic image analysis utilising convolutional neural networks (CNNs) can be used to evaluate computed tomography urography (CTU) for the presence of urinary bladder cancer (UBC) in patients with macroscopic hematuria. METHODS: Our study included patients who had undergone evaluation for macroscopic hematuria. A CNN-based AI model was trained and validated on the CTUs included in the study on a dedicated research platform (Recomia.org). Sensitivity and specificity were calculated to assess the performance of the AI model. Cystoscopy findings were used as the reference method. RESULTS: The training cohort comprised a total of 530 patients. Following the optimisation process, we developed the last version of our AI model. Subsequently, we utilised the model in the validation cohort which included an additional 400 patients (including 239 patients with UBC). The AI model had a sensitivity of 0.83 (95% confidence intervals [CI], 0.76-0.89), specificity of 0.76 (95% CI 0.67-0.84), and a negative predictive value (NPV) of 0.97 (95% CI 0.95-0.98). The majority of tumours in the false negative group (n = 24) were solitary (67%) and smaller than 1 cm (50%), with the majority of patients having cTaG1-2 (71%). CONCLUSIONS: We developed and tested an AI model for automatic image analysis of CTUs to detect UBC in patients with macroscopic hematuria. This model showed promising results with a high detection rate and excessive NPV. Further developments could lead to a decreased need for invasive investigations and prioritising patients with serious tumours.


Asunto(s)
Inteligencia Artificial , Hematuria , Tomografía Computarizada por Rayos X , Neoplasias de la Vejiga Urinaria , Urografía , Humanos , Hematuria/etiología , Hematuria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/complicaciones , Masculino , Anciano , Femenino , Tomografía Computarizada por Rayos X/métodos , Urografía/métodos , Persona de Mediana Edad , Redes Neurales de la Computación , Sensibilidad y Especificidad , Anciano de 80 o más Años , Estudios Retrospectivos , Adulto
3.
Clin Physiol Funct Imaging ; 44(4): 332-339, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38563413

RESUMEN

BACKGROUND: We developed a fully automated artificial intelligence (AI)AI-based-based method for detecting suspected lymph node metastases in prostate-specific membrane antigen (PSMA)(PSMA) positron emission tomography-computed tomography (PET-CT)(PET-CT) images of prostate cancer patients by using data augmentation that adds synthetic lymph node metastases to the images to expand the training set. METHODS: Synthetic data were derived from original training images to which new synthetic lymph node metastases were added. Thus, the original training set from a previous study (n = 420) was expanded by one synthetic image for every original image (n = 840), which was used to train an AI model. The performance of the AI model was compared to that of nuclear medicine physicians and a previously developed AI model. The human readers were alternately used as a reference and compared to either another reading or AI model. RESULTS: The new AI model had an average sensitivity of 84% for detecting lymph node metastases compared with 78% for human readings. Our previously developed AI method without synthetic data had an average sensitivity of 79%. The number of false positive lesions were slightly higher for the new AI model (average 3.3 instances per patient) compared to human readings and the previous AI model (average 2.8 instances per patient), while the number of false negative lesions was lower. CONCLUSIONS: Creating synthetic lymph node metastases, as a form of data augmentation, on [18F]PSMA-1007F]PSMA-1007 PETPET-CT-CT images improved the sensitivity of an AI model for detecting suspected lymph node metastases. However, the number of false positive lesions increased somewhat.


Asunto(s)
Glutamato Carboxipeptidasa II , Ganglios Linfáticos , Metástasis Linfática , Tomografía Computarizada por Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Neoplasias de la Próstata , Humanos , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Glutamato Carboxipeptidasa II/metabolismo , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Reproducibilidad de los Resultados , Antígenos de Superficie/metabolismo , Inteligencia Artificial , Automatización , Anciano , Interpretación de Imagen Asistida por Computador/métodos , Persona de Mediana Edad , Radiofármacos
4.
Adv Radiat Oncol ; 9(3): 101383, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38495038

RESUMEN

Purpose: Meticulous manual delineations of the prostate and the surrounding organs at risk are necessary for prostate cancer radiation therapy to avoid side effects to the latter. This process is time consuming and hampered by inter- and intraobserver variability, all of which could be alleviated by artificial intelligence (AI). This study aimed to evaluate the performance of AI compared with manual organ delineations on computed tomography (CT) scans for radiation treatment planning. Methods and Materials: Manual delineations of the prostate, urinary bladder, and rectum of 1530 patients with prostate cancer who received curative radiation therapy from 2006 to 2018 were included. Approximately 50% of those CT scans were used as a training set, 25% as a validation set, and 25% as a test set. Patients with hip prostheses were excluded because of metal artifacts. After training and fine-tuning with the validation set, automated delineations of the prostate and organs at risk were obtained for the test set. Sørensen-Dice similarity coefficient, mean surface distance, and Hausdorff distance were used to evaluate the agreement between the manual and automated delineations. Results: The median Sørensen-Dice similarity coefficient between the manual and AI delineations was 0.82, 0.95, and 0.88 for the prostate, urinary bladder, and rectum, respectively. The median mean surface distance and Hausdorff distance were 1.7 and 9.2 mm for the prostate, 0.7 and 6.7 mm for the urinary bladder, and 1.1 and 13.5 mm for the rectum, respectively. Conclusions: Automated CT-based organ delineation for prostate cancer radiation treatment planning is feasible and shows good agreement with manually performed contouring.

5.
Eur J Nucl Med Mol Imaging ; 51(8): 2293-2307, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38456971

RESUMEN

PURPOSE: Multiple myeloma (MM) is a highly heterogeneous disease with wide variations in patient outcome. [18F]FDG PET/CT can provide prognostic information in MM, but it is hampered by issues regarding standardization of scan interpretation. Our group has recently demonstrated the feasibility of automated, volumetric assessment of bone marrow (BM) metabolic activity on PET/CT using a novel artificial intelligence (AI)-based tool. Accordingly, the aim of the current study is to investigate the prognostic role of whole-body calculations of BM metabolism in patients with newly diagnosed MM using this AI tool. MATERIALS AND METHODS: Forty-four, previously untreated MM patients underwent whole-body [18F]FDG PET/CT. Automated PET/CT image segmentation and volumetric quantification of BM metabolism were based on an initial CT-based segmentation of the skeleton, its transfer to the standardized uptake value (SUV) PET images, subsequent application of different SUV thresholds, and refinement of the resulting regions using postprocessing. In the present analysis, ten different uptake thresholds (AI approaches), based on reference organs or absolute SUV values, were applied for definition of pathological tracer uptake and subsequent calculation of the whole-body metabolic tumor volume (MTV) and total lesion glycolysis (TLG). Correlation analysis was performed between the automated PET values and histopathological results of the BM as well as patients' progression-free survival (PFS) and overall survival (OS). Receiver operating characteristic (ROC) curve analysis was used to investigate the discrimination performance of MTV and TLG for prediction of 2-year PFS. The prognostic performance of the new Italian Myeloma criteria for PET Use (IMPeTUs) was also investigated. RESULTS: Median follow-up [95% CI] of the patient cohort was 110 months [105-123 months]. AI-based BM segmentation and calculation of MTV and TLG were feasible in all patients. A significant, positive, moderate correlation was observed between the automated quantitative whole-body PET/CT parameters, MTV and TLG, and BM plasma cell infiltration for all ten [18F]FDG uptake thresholds. With regard to PFS, univariable analysis for both MTV and TLG predicted patient outcome reasonably well for all AI approaches. Adjusting for cytogenetic abnormalities and BM plasma cell infiltration rate, multivariable analysis also showed prognostic significance for high MTV, which defined pathological [18F]FDG uptake in the BM via the liver. In terms of OS, univariable and multivariable analysis showed that whole-body MTV, again mainly using liver uptake as reference, was significantly associated with shorter survival. In line with these findings, ROC curve analysis showed that MTV and TLG, assessed using liver-based cut-offs, could predict 2-year PFS rates. The application of IMPeTUs showed that the number of focal hypermetabolic BM lesions and extramedullary disease had an adverse effect on PFS. CONCLUSIONS: The AI-based, whole-body calculations of BM metabolism via the parameters MTV and TLG not only correlate with the degree of BM plasma cell infiltration, but also predict patient survival in MM. In particular, the parameter MTV, using the liver uptake as reference for BM segmentation, provides solid prognostic information for disease progression. In addition to highlighting the prognostic significance of automated, global volumetric estimation of metabolic tumor burden, these data open up new perspectives towards solving the complex problem of interpreting PET scans in MM with a simple, fast, and robust method that is not affected by operator-dependent interventions.


Asunto(s)
Inteligencia Artificial , Médula Ósea , Fluorodesoxiglucosa F18 , Mieloma Múltiple , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/metabolismo , Masculino , Femenino , Persona de Mediana Edad , Médula Ósea/diagnóstico por imagen , Médula Ósea/metabolismo , Anciano , Pronóstico , Adulto , Anciano de 80 o más Años , Análisis de Supervivencia , Procesamiento de Imagen Asistido por Computador
6.
Semin Nucl Med ; 54(1): 141-149, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37357026

RESUMEN

Prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (PET/CT) has emerged as an important imaging technique for prostate cancer. The use of PSMA PET/CT is rapidly increasing, while the number of nuclear medicine physicians and radiologists to interpret these scans is limited. Additionally, there is variability in interpretation among readers. Artificial intelligence techniques, including traditional machine learning and deep learning algorithms, are being used to address these challenges and provide additional insights from the images. The aim of this scoping review was to summarize the available research on the development and applications of AI in PSMA PET/CT for prostate cancer imaging. A systematic literature search was performed in PubMed, Embase and Cinahl according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A total of 26 publications were included in the synthesis. The included studies focus on different aspects of artificial intelligence in PSMA PET/CT, including detection of primary tumor, local recurrence and metastatic lesions, lesion classification, tumor quantification and prediction/prognostication. Several studies show similar performances of artificial intelligence algorithms compared to human interpretation. Few artificial intelligence tools are approved for use in clinical practice. Major limitations include the lack of external validation and prospective design. Demonstrating the clinical impact and utility of artificial intelligence tools is crucial for their adoption in healthcare settings. To take the next step towards a clinically valuable artificial intelligence tool that provides quantitative data, independent validation studies are needed across institutions and equipment to ensure robustness.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Próstata/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Inteligencia Artificial , Radioisótopos de Galio , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología
7.
Eur J Hybrid Imaging ; 7(1): 14, 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37544941

RESUMEN

BACKGROUND: Segmenting the whole-body somatostatin receptor-expressing tumour volume (SRETVwb) on positron emission tomography/computed tomography (PET/CT) images is highly time-consuming but has shown value as an independent prognostic factor for survival. An automatic method to measure SRETVwb could improve disease status assessment and provide a tool for prognostication. This study aimed to develop an artificial intelligence (AI)-based method to detect and quantify SRETVwb and total lesion somatostatin receptor expression (TLSREwb) from [68Ga]Ga-DOTA-TOC/TATE PET/CT images. METHODS: A UNet3D convolutional neural network (CNN) was used to train an AI model with [68Ga]Ga-DOTA-TOC/TATE PET/CT images, where all tumours were manually segmented with a semi-automatic method. The training set consisted of 148 patients, of which 108 had PET-positive tumours. The test group consisted of 30 patients, of which 25 had PET-positive tumours. Two physicians segmented tumours in the test group for comparison with the AI model. RESULTS: There were good correlations between the segmented SRETVwb and TLSREwb by the AI model and the physicians, with Spearman rank correlation coefficients of r = 0.78 and r = 0.73, respectively, for SRETVwb and r = 0.83 and r = 0.81, respectively, for TLSREwb. The sensitivity on a lesion detection level was 80% and 79%, and the positive predictive value was 83% and 84% when comparing the AI model with the two physicians. CONCLUSION: It was possible to develop an AI model to segment SRETVwb and TLSREwb with high performance. A fully automated method makes quantification of tumour burden achievable and has the potential to be more widely used when assessing PET/CT images.

8.
Eur J Nucl Med Mol Imaging ; 50(12): 3697-3708, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37493665

RESUMEN

PURPOSE: [18F]FDG PET/CT is an imaging modality of high performance in multiple myeloma (MM). Nevertheless, the inter-observer reproducibility in PET/CT scan interpretation may be hampered by the different patterns of bone marrow (BM) infiltration in the disease. Although many approaches have been recently developed to address the issue of standardization, none can yet be considered a standard method in the interpretation of PET/CT. We herein aim to validate a novel three-dimensional deep learning-based tool on PET/CT images for automated assessment of the intensity of BM metabolism in MM patients. MATERIALS AND METHODS: Whole-body [18F]FDG PET/CT scans of 35 consecutive, previously untreated MM patients were studied. All patients were investigated in the context of an open-label, multicenter, randomized, active-controlled, phase 3 trial (GMMG-HD7). Qualitative (visual) analysis classified the PET/CT scans into three groups based on the presence and number of focal [18F]FDG-avid lesions as well as the degree of diffuse [18F]FDG uptake in the BM. The proposed automated method for BM metabolism assessment is based on an initial CT-based segmentation of the skeleton, its transfer to the SUV PET images, the subsequent application of different SUV thresholds, and refinement of the resulting regions using postprocessing. In the present analysis, six different SUV thresholds (Approaches 1-6) were applied for the definition of pathological tracer uptake in the skeleton [Approach 1: liver SUVmedian × 1.1 (axial skeleton), gluteal muscles SUVmedian × 4 (extremities). Approach 2: liver SUVmedian × 1.5 (axial skeleton), gluteal muscles SUVmedian × 4 (extremities). Approach 3: liver SUVmedian × 2 (axial skeleton), gluteal muscles SUVmedian × 4 (extremities). Approach 4: ≥ 2.5. Approach 5: ≥ 2.5 (axial skeleton), ≥ 2.0 (extremities). Approach 6: SUVmax liver]. Using the resulting masks, subsequent calculations of the whole-body metabolic tumor volume (MTV) and total lesion glycolysis (TLG) in each patient were performed. A correlation analysis was performed between the automated PET values and the results of the visual PET/CT analysis as well as the histopathological, cytogenetical, and clinical data of the patients. RESULTS: BM segmentation and calculation of MTV and TLG after the application of the deep learning tool were feasible in all patients. A significant positive correlation (p < 0.05) was observed between the results of the visual analysis of the PET/CT scans for the three patient groups and the MTV and TLG values after the employment of all six [18F]FDG uptake thresholds. In addition, there were significant differences between the three patient groups with regard to their MTV and TLG values for all applied thresholds of pathological tracer uptake. Furthermore, we could demonstrate a significant, moderate, positive correlation of BM plasma cell infiltration and plasma levels of ß2-microglobulin with the automated quantitative PET/CT parameters MTV and TLG after utilization of Approaches 1, 2, 4, and 5. CONCLUSIONS: The automated, volumetric, whole-body PET/CT assessment of the BM metabolic activity in MM is feasible with the herein applied method and correlates with clinically relevant parameters in the disease. This methodology offers a potentially reliable tool in the direction of optimization and standardization of PET/CT interpretation in MM. Based on the present promising findings, the deep learning-based approach will be further evaluated in future prospective studies with larger patient cohorts.


Asunto(s)
Mieloma Múltiple , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Inteligencia Artificial , Médula Ósea/metabolismo , Fluorodesoxiglucosa F18/metabolismo , Glucólisis , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/patología , Pronóstico , Radiofármacos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Carga Tumoral
9.
Nucl Med Mol Imaging ; 57(2): 110-116, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36998589

RESUMEN

Purpose: Classification of focal skeleton/bone marrow uptake (BMU) can be challenging. The aim is to investigate whether an artificial intelligence-based method (AI), which highlights suspicious focal BMU, increases interobserver agreement among a group of physicians from different hospitals classifying Hodgkin's lymphoma (HL) patients staged with [18F]FDG PET/CT. Methods: Forty-eight patients staged with [18F]FDG PET/CT at Sahlgenska University Hospital between 2017 and 2018 were reviewed twice, 6 months apart, regarding focal BMU. During the second time review, the 10 physicians also had access to AI-based advice regarding focal BMU. Results: Each physician's classifications were pairwise compared with the classifications made by all the other physicians, resulting in 45 unique pairs of comparisons both without and with AI advice. The agreement between the physicians increased significantly when AI advice was available, which was measured as an increase in mean Kappa values from 0.51 (range 0.25-0.80) without AI advice to 0.61 (range 0.19-0.94) with AI advice (p = 0.005). The majority of the physicians agreed with the AI-based method in 40 (83%) of the 48 cases. Conclusion: An AI-based method significantly increases interobserver agreement among physicians working at different hospitals by highlighting suspicious focal BMU in HL patients staged with [18F]FDG PET/CT.

10.
Clin Physiol Funct Imaging ; 43(2): 71-77, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36331059

RESUMEN

BACKGROUND: Carotid atherosclerosis is a major cause of stroke, traditionally diagnosed late. Positron emission tomography/computed tomography (PET/CT) with 18 F-sodium fluoride (NaF) detects arterial wall micro-calcification long before macro-calcification becomes detectable by ultrasound, CT or magnetic resonance imaging. However, manual PET/CT processing is time-consuming and requires experience. We compared a convolutional neural network (CNN) approach with manual segmentation of the common carotids. METHODS: Segmentation in NaF-PET/CT scans of 29 healthy volunteers and 20 angina pectoris patients were compared for segmented volume (Vol) and mean, maximal, and total standardized uptake values (SUVmean, SUVmax, and SUVtotal). SUVmean was the average of SUVmeans within the VOI, SUVmax the highest SUV in all voxels in the VOI, and SUVtotal the SUVmean multiplied by the Vol of the VOI. Intra and Interobserver variability with manual segmentation was examined in 25 randomly selected scans. RESULTS: Bias for Vol, SUVmean, SUVmax, and SUVtotal were 1.33 ± 2.06, -0.01 ± 0.05, 0.09 ± 0.48, and 1.18 ± 1.99 in the left and 1.89 ± 1.5, -0.07 ± 0.12, 0.05 ± 0.47, and 1.61 ± 1.47, respectively, in the right common carotid artery. Manual segmentation lasted typically 20 min versus 1 min with the CNN-based approach. Mean Vol deviation at repeat manual segmentation was 14% and 27% in left and right common carotids. CONCLUSIONS: CNN-based segmentation was much faster and provided SUVmean values virtually identical to manually obtained ones, suggesting CNN-based analysis as a promising substitute of slow and cumbersome manual processing.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluoruro de Sodio , Humanos , Inteligencia Artificial , Arterias Carótidas/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Cintigrafía
11.
Diagnostics (Basel) ; 12(9)2022 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-36140502

RESUMEN

Here, we aimed to develop and validate a fully automated artificial intelligence (AI)-based method for the detection and quantification of suspected prostate tumour/local recurrence, lymph node metastases, and bone metastases from [18F]PSMA-1007 positron emission tomography-computed tomography (PET-CT) images. Images from 660 patients were included. Segmentations by one expert reader were ground truth. A convolutional neural network (CNN) was developed and trained on a training set, and the performance was tested on a separate test set of 120 patients. The AI method was compared with manual segmentations performed by several nuclear medicine physicians. Assessment of tumour burden (total lesion volume (TLV) and total lesion uptake (TLU)) was performed. The sensitivity of the AI method was, on average, 79% for detecting prostate tumour/recurrence, 79% for lymph node metastases, and 62% for bone metastases. On average, nuclear medicine physicians' corresponding sensitivities were 78%, 78%, and 59%, respectively. The correlations of TLV and TLU between AI and nuclear medicine physicians were all statistically significant and ranged from R = 0.53 to R = 0.83. In conclusion, the development of an AI-based method for prostate cancer detection with sensitivity on par with nuclear medicine physicians was possible. The developed AI tool is freely available for researchers.

12.
Clin Physiol Funct Imaging ; 42(5): 327-332, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35760559

RESUMEN

INTRODUCTION: Recently, a tool called the positron emission tomography (PET)-assisted reporting system (PARS) was developed and presented to classify lesions in PET/computed tomography (CT) studies in patients with lung cancer or lymphoma. The aim of this study was to validate PARS with an independent group of lung-cancer patients using manual lesion segmentations as a reference standard, as well as to evaluate the association between PARS-based measurements and overall survival (OS). METHODS: This study retrospectively included 115 patients who had undergone clinically indicated (18F)-fluorodeoxyglucose (FDG) PET/CT due to suspected or known lung cancer. The patients had a median age of 66 years (interquartile range [IQR]: 61-72 years). Segmentations were made manually by visual inspection in a consensus reading by two nuclear medicine specialists and used as a reference. The research prototype PARS was used to automatically analyse all the PET/CT studies. The PET foci classified as suspicious by PARS were compared with the manual segmentations. No manual corrections were applied. Total lesion glycolysis (TLG) was calculated based on the manual and PARS-based lung-tumour segmentations. Associations between TLG and OS were investigated using Cox analysis. RESULTS: PARS showed sensitivities for lung tumours of 55.6% per lesion and 80.2% per patient. Both manual and PARS TLG were significantly associated with OS. CONCLUSION: Automatically calculated TLG by PARS contains prognostic information comparable to manually measured TLG in patients with known or suspected lung cancer. The low sensitivity at both the lesion and patient levels makes the present version of PARS less useful to support clinical reading, reporting and staging.


Asunto(s)
Neoplasias Pulmonares , Tomografía Computarizada por Tomografía de Emisión de Positrones , Anciano , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Pronóstico , Radiofármacos , Estudios Retrospectivos
13.
Eur J Nucl Med Mol Imaging ; 49(10): 3412-3418, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35475912

RESUMEN

PURPOSE: The aim of this study was to develop and validate an artificial intelligence (AI)-based method using convolutional neural networks (CNNs) for the detection of pelvic lymph node metastases in scans obtained using [18F]PSMA-1007 positron emission tomography-computed tomography (PET-CT) from patients with high-risk prostate cancer. The second goal was to make the AI-based method available to other researchers. METHODS: [18F]PSMA PET-CT scans were collected from 211 patients. Suspected pelvic lymph node metastases were marked by three independent readers. A CNN was developed and trained on a training and validation group of 161 of the patients. The performance of the AI method and the inter-observer agreement between the three readers were assessed in a separate test group of 50 patients. RESULTS: The sensitivity of the AI method for detecting pelvic lymph node metastases was 82%, and the corresponding sensitivity for the human readers was 77% on average. The average number of false positives was 1.8 per patient. A total of 5-17 false negative lesions in the whole cohort were found, depending on which reader was used as a reference. The method is available for researchers at www.recomia.org . CONCLUSION: This study shows that AI can obtain a sensitivity on par with that of physicians with a reasonable number of false positives. The difficulty in achieving high inter-observer sensitivity emphasizes the need for automated methods. On the road to qualifying AI tools for clinical use, independent validation is critical and allows performance to be assessed in studies from different hospitals. Therefore, we have made our AI tool freely available to other researchers.


Asunto(s)
Medicina Nuclear , Médicos , Neoplasias de la Próstata , Inteligencia Artificial , Radioisótopos de Galio , Humanos , Metástasis Linfática/diagnóstico por imagen , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Radiofármacos
14.
Clin Physiol Funct Imaging ; 42(4): 225-232, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35319166

RESUMEN

BACKGROUND: Current imaging modalities are often incapable of identifying nociceptive sources of low back pain (LBP). We aimed to characterize these by means of positron emission tomography/computed tomography (PET/CT) of the lumbar spine region applying tracers 18 F-fluorodeoxyglucose (FDG) and 18 F-sodium fluoride (NaF) targeting inflammation and active microcalcification, respectively. METHODS: Using artificial intelligence (AI)-based quantification, we compared PET findings in two sex- and age-matched groups, a case group of seven males and five females, mean age 45 ± 14 years, with ongoing LBP and a similar control group of 12 pain-free individuals. PET/CT scans were segmented into three distinct volumes of interest (VOIs): lumbar vertebral bodies, facet joints and intervertebral discs. Maximum, mean and total standardized uptake values (SUVmax, SUVmean and SUVtotal) for FDG and NaF uptake in the 3 VOIs were measured and compared between groups. Holm-Bonferroni correction was applied to adjust for multiple testing. RESULTS: FDG uptake was slightly higher in most locations of the LBP group including higher SUVmean in the intervertebral discs (0.96 ± 0.34 vs. 0.69 ± 0.15). All NaF uptake values were higher in cases, including higher SUVmax in the intervertebral discs (11.63 ± 3.29 vs. 9.45 ± 1.32) and facet joints (14.98 ± 6.55 vs. 10.60 ± 2.97). CONCLUSION: Observed intergroup differences suggest acute inflammation and microcalcification as possible nociceptive causes of LBP. AI-based quantification of relevant lumbar VOIs in PET/CT scans of LBP patients and controls appears to be feasible. These promising, early findings warrant further investigation and confirmation.


Asunto(s)
Calcinosis , Dolor de la Región Lumbar , Adulto , Inteligencia Artificial , Femenino , Fluorodesoxiglucosa F18 , Humanos , Inflamación/complicaciones , Inflamación/diagnóstico por imagen , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/etiología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Fluoruro de Sodio
15.
EJNMMI Phys ; 9(1): 6, 2022 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-35113252

RESUMEN

BACKGROUND: Metabolic positron emission tomography/computed tomography (PET/CT) parameters describing tumour activity contain valuable prognostic information, but to perform the measurements manually leads to both intra- and inter-reader variability and is too time-consuming in clinical practice. The use of modern artificial intelligence-based methods offers new possibilities for automated and objective image analysis of PET/CT data. PURPOSE: We aimed to train a convolutional neural network (CNN) to segment and quantify tumour burden in [18F]-fluorodeoxyglucose (FDG) PET/CT images and to evaluate the association between CNN-based measurements and overall survival (OS) in patients with lung cancer. A secondary aim was to make the method available to other researchers. METHODS: A total of 320 consecutive patients referred for FDG PET/CT due to suspected lung cancer were retrospectively selected for this study. Two nuclear medicine specialists manually segmented abnormal FDG uptake in all of the PET/CT studies. One-third of the patients were assigned to a test group. Survival data were collected for this group. The CNN was trained to segment lung tumours and thoracic lymph nodes. Total lesion glycolysis (TLG) was calculated from the CNN-based and manual segmentations. Associations between TLG and OS were investigated using a univariate Cox proportional hazards regression model. RESULTS: The test group comprised 106 patients (median age, 76 years (IQR 61-79); n = 59 female). Both CNN-based TLG (hazard ratio 1.64, 95% confidence interval 1.21-2.21; p = 0.001) and manual TLG (hazard ratio 1.54, 95% confidence interval 1.14-2.07; p = 0.004) estimations were significantly associated with OS. CONCLUSION: Fully automated CNN-based TLG measurements of PET/CT data showed were significantly associated with OS in patients with lung cancer. This type of measurement may be of value for the management of future patients with lung cancer. The CNN is publicly available for research purposes.

16.
J Nucl Cardiol ; 29(4): 2001-2010, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-33982202

RESUMEN

BACKGROUND: We aimed to establish and test an automated AI-based method for rapid segmentation of the aortic wall in positron emission tomography/computed tomography (PET/CT) scans. METHODS: For segmentation of the wall in three sections: the arch, thoracic, and abdominal aorta, we developed a tool based on a convolutional neural network (CNN), available on the Research Consortium for Medical Image Analysis (RECOMIA) platform, capable of segmenting 100 different labels in CT images. It was tested on 18F-sodium fluoride PET/CT scans of 49 subjects (29 healthy controls and 20 angina pectoris patients) and compared to data obtained by manual segmentation. The following derived parameters were compared using Bland-Altman Limits of Agreement: segmented volume, and maximal, mean, and total standardized uptake values (SUVmax, SUVmean, SUVtotal). The repeatability of the manual method was examined in 25 randomly selected scans. RESULTS: CNN-derived values for volume, SUVmax, and SUVtotal were all slightly, i.e., 13-17%, lower than the corresponding manually obtained ones, whereas SUVmean values for the three aortic sections were virtually identical for the two methods. Manual segmentation lasted typically 1-2 hours per scan compared to about one minute with the CNN-based approach. The maximal deviation at repeat manual segmentation was 6%. CONCLUSIONS: The automated CNN-based approach was much faster and provided parameters that were about 15% lower than the manually obtained values, except for SUVmean values, which were comparable. AI-based segmentation of the aorta already now appears as a trustworthy and fast alternative to slow and cumbersome manual segmentation.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluoruro de Sodio , Aorta/diagnóstico por imagen , Inteligencia Artificial , Humanos , Redes Neurales de la Computación , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
17.
Clin Imaging ; 81: 54-59, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34598006

RESUMEN

BACKGROUND: Osteoporosis is an underdiagnosed and undertreated disease worldwide. Recent studies have highlighted the use of simple vertebral trabecular attenuation values for opportunistic osteoporosis screening. Meanwhile, machine learning has been used to accurately segment large parts of the human skeleton. PURPOSE: To evaluate a fully automated deep learning-based method for lumbar vertebral segmentation and measurement of vertebral volumetric trabecular attenuation values. MATERIAL AND METHODS: A deep learning-based method for automated segmentation of bones was retrospectively applied to non-contrast CT scans of 1008 patients (mean age 57 years, 472 female, 536 male). Each vertebral segmentation was automatically reduced by 7 mm in all directions in order to avoid cortical bone. The mean and median volumetric attenuation values from Th12 to L4 were obtained and plotted against patient age and sex. L1 values were further analyzed to facilitate comparison with previous studies. RESULTS: The mean L1 attenuation values decreased linearly with age by -2.2 HU per year (age > 30, 95% CI: -2.4, -2.0, R2 = 0.3544). The mean L1 attenuation value of the entire population cohort was 140 HU ± 54. CONCLUSIONS: With results closely matching those of previous studies, we believe that our fully automated deep learning-based method can be used to obtain lumbar volumetric trabecular attenuation values which can be used for opportunistic screening of osteoporosis in patients undergoing CT scans for other reasons.


Asunto(s)
Aprendizaje Profundo , Osteoporosis , Absorciometría de Fotón , Densidad Ósea , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteoporosis/diagnóstico por imagen , Estudios Retrospectivos
18.
J Nucl Cardiol ; 29(5): 2531-2539, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34386861

RESUMEN

BACKGROUND: Artificial intelligence (AI) is known to provide effective means to accelerate and facilitate clinical and research processes. So in this study it was aimed to compare a AI-based method for cardiac segmentation in positron emission tomography/computed tomography (PET/CT) scans with manual segmentation to assess global cardiac atherosclerosis burden. METHODS: A trained convolutional neural network (CNN) was used for cardiac segmentation in 18F-sodium fluoride PET/CT scans of 29 healthy volunteers and 20 angina pectoris patients and compared with manual segmentation. Parameters for segmented volume (Vol) and mean, maximal, and total standardized uptake values (SUVmean, SUVmax, SUVtotal) were analyzed by Bland-Altman Limits of Agreement. Repeatability with AI-based assessment of the same scans is 100%. Repeatability (same conditions, same operator) and reproducibility (same conditions, two different operators) of manual segmentation was examined by re-segmentation in 25 randomly selected scans. RESULTS: Mean (± SD) values with manual vs. CNN-based segmentation were Vol 617.65 ± 154.99 mL vs 625.26 ± 153.55 mL (P = .21), SUVmean 0.69 ± 0.15 vs 0.69 ± 0.15 (P = .26), SUVmax 2.68 ± 0.86 vs 2.77 ± 1.05 (P = .34), and SUVtotal 425.51 ± 138.93 vs 427.91 ± 132.68 (P = .62). Limits of agreement were - 89.42 to 74.2, - 0.02 to 0.02, - 1.52 to 1.32, and - 68.02 to 63.21, respectively. Manual segmentation lasted typically 30 minutes vs about one minute with the CNN-based approach. The maximal deviation at manual re-segmentation was for the four parameters 0% to 0.5% with the same and 0% to 1% with different operators. CONCLUSION: The CNN-based method was faster and provided values for Vol, SUVmean, SUVmax, and SUVtotal comparable to the manually obtained ones. This AI-based segmentation approach appears to offer a more reproducible and much faster substitute for slow and cumbersome manual segmentation of the heart.


Asunto(s)
Aterosclerosis , Tomografía Computarizada por Tomografía de Emisión de Positrones , Inteligencia Artificial , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Reproducibilidad de los Resultados , Fluoruro de Sodio
19.
Sci Rep ; 11(1): 23905, 2021 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-34903773

RESUMEN

To develop a fully automatic model capable of reliably quantifying epicardial adipose tissue (EAT) volumes and attenuation in large scale population studies to investigate their relation to markers of cardiometabolic risk. Non-contrast cardiac CT images from the SCAPIS study were used to train and test a convolutional neural network based model to quantify EAT by: segmenting the pericardium, suppressing noise-induced artifacts in the heart chambers, and, if image sets were incomplete, imputing missing EAT volumes. The model achieved a mean Dice coefficient of 0.90 when tested against expert manual segmentations on 25 image sets. Tested on 1400 image sets, the model successfully segmented 99.4% of the cases. Automatic imputation of missing EAT volumes had an error of less than 3.1% with up to 20% of the slices in image sets missing. The most important predictors of EAT volumes were weight and waist, while EAT attenuation was predicted mainly by EAT volume. A model with excellent performance, capable of fully automatic handling of the most common challenges in large scale EAT quantification has been developed. In studies of the importance of EAT in disease development, the strong co-variation with anthropometric measures needs to be carefully considered.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Aprendizaje Automático , Pericardio/diagnóstico por imagen , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/normas , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Programas Informáticos/normas
20.
Eur Radiol Exp ; 5(1): 50, 2021 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-34796422

RESUMEN

BACKGROUND: Radical cystectomy for urinary bladder cancer is a procedure associated with a high risk of complications, and poor overall survival (OS) due to both patient and tumour factors. Sarcopenia is one such patient factor. We have developed a fully automated artificial intelligence (AI)-based image analysis tool for segmenting skeletal muscle of the torso and calculating the muscle volume. METHODS: All patients who have undergone radical cystectomy for urinary bladder cancer 2011-2019 at Sahlgrenska University Hospital, and who had a pre-operative computed tomography of the abdomen within 90 days of surgery were included in the study. All patients CT studies were analysed with the automated AI-based image analysis tool. Clinical data for the patients were retrieved from the Swedish National Register for Urinary Bladder Cancer. Muscle volumes dichotomised by the median for each sex were analysed with Cox regression for OS and logistic regression for 90-day high-grade complications. The study was approved by the Swedish Ethical Review Authority (2020-03985). RESULTS: Out of 445 patients who underwent surgery, 299 (67%) had CT studies available for analysis. The automated AI-based tool failed to segment the muscle volume in seven (2%) patients. Cox regression analysis showed an independent significant association with OS (HR 1.62; 95% CI 1.07-2.44; p = 0.022). Logistic regression did not show any association with high-grade complications. CONCLUSION: The fully automated AI-based CT image analysis provides a low-cost and meaningful clinical measure that is an independent biomarker for OS following radical cystectomy.


Asunto(s)
Cistectomía , Neoplasias de la Vejiga Urinaria , Inteligencia Artificial , Cistectomía/efectos adversos , Femenino , Humanos , Masculino , Músculo Esquelético/diagnóstico por imagen , Estudios Retrospectivos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen , Neoplasias de la Vejiga Urinaria/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...