Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Metrologia ; 50(6): 663-678, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26361398

RESUMEN

This paper reports an interlaboratory comparison that evaluated a protocol for measuring and analysing the particle size distribution of discrete, metallic, spheroidal nanoparticles using transmission electron microscopy (TEM). The study was focused on automated image capture and automated particle analysis. NIST RM8012 gold nanoparticles (30 nm nominal diameter) were measured for area-equivalent diameter distributions by eight laboratories. Statistical analysis was used to (1) assess the data quality without using size distribution reference models, (2) determine reference model parameters for different size distribution reference models and non-linear regression fitting methods and (3) assess the measurement uncertainty of a size distribution parameter by using its coefficient of variation. The interlaboratory area-equivalent diameter mean, 27.6 nm ± 2.4 nm (computed based on a normal distribution), was quite similar to the area-equivalent diameter, 27.6 nm, assigned to NIST RM8012. The lognormal reference model was the preferred choice for these particle size distributions as, for all laboratories, its parameters had lower relative standard errors (RSEs) than the other size distribution reference models tested (normal, Weibull and Rosin-Rammler-Bennett). The RSEs for the fitted standard deviations were two orders of magnitude higher than those for the fitted means, suggesting that most of the parameter estimate errors were associated with estimating the breadth of the distributions. The coefficients of variation for the interlaboratory statistics also confirmed the lognormal reference model as the preferred choice. From quasi-linear plots, the typical range for good fits between the model and cumulative number-based distributions was 1.9 fitted standard deviations less than the mean to 2.3 fitted standard deviations above the mean. Automated image capture, automated particle analysis and statistical evaluation of the data and fitting coefficients provide a framework for assessing nanoparticle size distributions using TEM for image acquisition.

2.
Nanotoxicology ; 4(1): 73-83, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20795903

RESUMEN

Endotoxin has established health impacts and may be a potential confounding factor in toxicity studies of engineered nanomaterials (ENM). We aimed to characterize endotoxin contamination for a representative set of carbon-based ENM. The established method for quantifying endotoxin relies on its activity in a complex biochemical assay system. Because of their physical and chemical properties, measurement of endotoxin associated with many ENM presents non-trivial technical challenges. We have made progress in identifying and implementing methods for ENM analysis with respect to endotoxin content, revealing varying levels of endotoxin contamination in the ENM examined here. The physical association of ENM and endotoxin and their shared physiological effects suggest the possibility that contaminating endotoxin may contribute to the toxicity that is ascribed to ENM. We found in this small number of samples that endotoxin levels were not related to type of ENM or surface area but may be introduced randomly during manufacture.


Asunto(s)
Endotoxinas/metabolismo , Contaminación de Equipos , Materiales Manufacturados/microbiología , Nanoestructuras/microbiología , Animales , Endotoxinas/química , Humanos , Estructura Molecular , Nanoestructuras/química , Distribución Aleatoria , Medición de Riesgo
3.
Biosecur Bioterror ; 4(1): 41-54, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16545023

RESUMEN

The prospect of biological attacks is a growing strategic threat. Covert aerosol attacks inside a building are of particular concern. In the summer of 2005, the Center for Biosecurity of the University of Pittsburgh Medical Center convened a Working Group to determine what steps could be taken to reduce the risk of exposure of building occupants after an aerosol release of a biological weapon. The Working Group was composed of subject matter experts in air filtration, building ventilation and pressurization, air conditioning and air distribution, biosecurity, building design and operation, building decontamination and restoration, economics, medicine, public health, and public policy. The group focused on functions of the heating, ventilation, and air conditioning systems in commercial or public buildings that could reduce the risk of exposure to deleterious aerosols following biological attacks. The Working Group's recommendations for building owners are based on the use of currently available, off-the-shelf technologies. These recommendations are modest in expense and could be implemented immediately. It is also the Working Group's judgment that the commitment and stewardship of a lead government agency is essential to secure the necessary financial and human resources and to plan and build a comprehensive, effective program to reduce exposure to aerosolized infectious agents in buildings.


Asunto(s)
Microbiología del Aire , Contaminación del Aire Interior/prevención & control , Bioterrorismo/prevención & control , Control de Enfermedades Transmisibles/métodos , Planificación en Desastres , Ambiente Controlado , Gestión de Riesgos/métodos , Comités Consultivos , Aerosoles/toxicidad , Aire Acondicionado/instrumentación , Comercio/normas , Filtración/instrumentación , Calefacción/instrumentación , Humanos , Liderazgo , Pennsylvania , Instalaciones Públicas/normas , Ventilación/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...