Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Otol Neurotol ; 45(5): 564-571, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38728560

RESUMEN

OBJECTIVE: To investigate the safety and feasibility of precise delivery of a long-acting gel formulation containing 6% dexamethasone (SPT-2101) to the round window membrane for the treatment of Menière's disease. STUDY DESIGN: Prospective, unblinded, cohort study. SETTING: Tertiary care neurotology clinic. PATIENTS: Adults 18 to 85 years with a diagnosis of unilateral definite Menière's disease per Barany society criteria. INTERVENTIONS: A single injection of a long-acting gel formulation under direct visualization into the round window niche. MAIN OUTCOME MEASURES: Procedure success rate, adverse events, and vertigo control. Vertigo control was measured with definitive vertigo days (DVDs), defined as any day with a vertigo attack lasting 20 minutes or longer. RESULTS: Ten subjects with unilateral Menière's disease were enrolled. Precise placement of SPT-2101 at the round window was achieved in all subjects with in-office microendoscopy. Adverse events included one tympanic membrane perforation, which healed spontaneously after the study, and two instances of otitis media, which resolved with antibiotics. The average number of DVDs was 7.6 during the baseline month, decreasing to 3.3 by month 1, 3.7 by month 2, and 1.9 by month 3. Seventy percent of subjects had zero DVDs during the third month after treatment. CONCLUSIONS: SPT-2101 delivery to the round window is safe and feasible, and controlled trials are warranted to formally assess efficacy.


Asunto(s)
Dexametasona , Enfermedad de Meniere , Ventana Redonda , Humanos , Enfermedad de Meniere/tratamiento farmacológico , Dexametasona/administración & dosificación , Dexametasona/uso terapéutico , Persona de Mediana Edad , Masculino , Femenino , Anciano , Adulto , Resultado del Tratamiento , Estudios Prospectivos , Anciano de 80 o más Años , Preparaciones de Acción Retardada , Estudios de Cohortes , Vértigo/tratamiento farmacológico , Antiinflamatorios/administración & dosificación , Antiinflamatorios/uso terapéutico , Geles , Adulto Joven
2.
Retina ; 40(8): 1520-1528, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31436674

RESUMEN

PURPOSE: To develop an animal model of vitreous hemorrhage (VH) to explore the impact of surgical parameters on VH associated with insertion of the Port Delivery System with ranibizumab (PDS) implant. METHODS: Ninety eyes from 45 treatment-naive male Yucatan minipigs received PDS implant insertion or a sham procedure. The effect of prophylactic pars plana hemostasis, scleral incision length, scleral cauterization, surgical blade type/size, and viscoelastic usage on postsurgical VH was investigated. RESULTS: Postsurgical VH was detected in 60.0% (54/90) of implanted eyes. A systematic effect on VH was only detected for pars plana hemostasis before the pars plana incision. The percentage of eyes with VH was 96.6% (28/29) among eyes that did not receive prophylactic pars plana hemostasis and 42.4% (24/58) among eyes that did. There was no VH in eyes that received laser ablation of the pars plana using overlapping 1,000-ms spots; pars plana cautery or diathermy was less effective. The majority of all VH cases (83.3% [45/54]) were of mild to moderate severity (involving ≤25% of the fundus). CONCLUSION: In this minipig surgical model of VH, scleral dissection followed by pars plana laser ablation before pars plana incision most effectively mitigated VH secondary to PDS implant insertion.


Asunto(s)
Inhibidores de la Angiogénesis/administración & dosificación , Modelos Animales de Enfermedad , Sistemas de Liberación de Medicamentos , Ranibizumab/administración & dosificación , Esclerótica/cirugía , Cuerpo Vítreo/efectos de los fármacos , Hemorragia Vítrea/etiología , Animales , Implantes de Medicamentos , Estudios de Seguimiento , Homeostasis , Presión Intraocular/fisiología , Masculino , Porcinos , Porcinos Enanos , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Agudeza Visual/fisiología , Hemorragia Vítrea/diagnóstico , Hemorragia Vítrea/prevención & control
3.
Ophthalmology ; 126(8): 1141-1154, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30946888

RESUMEN

PURPOSE: To evaluate the safety and efficacy of the Port Delivery System with ranibizumab (PDS) for neovascular age-related macular degeneration (nAMD) treatment. DESIGN: Phase 2, multicenter, randomized, active treatment-controlled clinical trial. PARTICIPANTS: Patients diagnosed with nAMD within 9 months who had received 2 or more prior anti-vascular endothelial growth factor intravitreal injections and were responsive to treatment. METHODS: Patients were randomized 3:3:3:2 to receive the PDS filled with ranibizumab 10 mg/ml, 40 mg/ml, 100 mg/ml, or monthly intravitreal ranibizumab 0.5-mg injections. MAIN OUTCOME MEASURES: Time to first implant refill assessed when the last enrolled patient completed the month 9 visit (primary efficacy end point), improvement in best-corrected visual acuity (BCVA) and central foveal thickness (CFT), and safety. RESULTS: The primary analysis population was 220 patients, with 58, 62, 59, and 41 patients in the PDS 10-mg/ml, PDS 40-mg/ml, PDS 100-mg/ml, and monthly intravitreal ranibizumab 0.5-mg arms, respectively. Median time to first implant refill was 8.7, 13.0, and 15.0 months in the PDS 10-mg/ml, PDS 40-mg/ml, and PDS 100-mg/ml arms, respectively. At month 9, the adjusted mean BCVA change from baseline was ‒3.2 Early Treatment Diabetic Retinopathy Study (ETDRS) letters, ‒0.5 ETDRS letters, +5.0 ETDRS letters, and +3.9 ETDRS letters in the PDS 10-mg/ml, PDS 40-mg/ml, PDS 100-mg/ml, and monthly intravitreal ranibizumab 0.5-mg arms, respectively. At month 9, the adjusted mean CFT change from baseline was similar in the PDS 100-mg/ml and monthly intravitreal ranibizumab 0.5-mg arms. The optimized PDS implant insertion and refill procedures were generally well tolerated. After surgical procedure optimization, postoperative vitreous hemorrhage rate was 4.5% (7/157; 1 event classified as serious). There was no evidence of implant clogging. CONCLUSIONS: In the phase 2 Ladder trial, the PDS was generally well tolerated and demonstrated a dose response across multiple end points in patients with nAMD. The PDS 100-mg/ml arm showed visual and anatomic outcomes comparable with monthly intravitreal ranibizumab 0.5-mg injections but with a reduced total number of ranibizumab treatments. The PDS has the potential to reduce treatment burden in nAMD while maintaining vision.


Asunto(s)
Inhibidores de la Angiogénesis/administración & dosificación , Preparaciones de Acción Retardada/administración & dosificación , Implantes de Medicamentos , Degeneración Macular/tratamiento farmacológico , Ranibizumab/administración & dosificación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Inyecciones Intravítreas , Masculino , Persona de Mediana Edad
4.
Ophthalmic Surg Lasers Imaging ; 40(2): 160-8, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19320305

RESUMEN

BACKGROUND AND OBJECTIVE: To investigate the surgical feasibility and safety of a long-term intravitreal triamcinolone acetonide (TA) sustained delivery system. MATERIALS AND METHODS: Pigmented rabbits were implanted with sustained-release formulations containing 925 microg of TA within a non-biodegradable polymer coating: Dose A (n = 15) with a slow delivery rate of 1 to 2 microg/day and Dose B (n = 15) releasing 3 to 5 microg/day. Additionally, a control group (n = 10) using a device coated with polymer only was implanted. The devices were surgically implanted through a 30-gauge sclerotomy into the vitreous cavity. The animals were clinically observed for up to 6 months after the surgery with complete ophthalmologic examinations. Histologic evaluation of a subset of eyes was performed at the conclusion of the study. RESULTS: Implants were successfully implanted in all 40 eyes. Ocular examinations revealed excellent implant tolerability. In all eyes, there was no significant postoperative inflammation at 1 week of follow-up. There was no increase in intraocular pressure during the follow-up period and histologic evaluation demonstrated no significant abnormalities. Minimal and localized vitreous hemorrhage was observed in 22.5% of implanted eyes and mostly cleared at 1 month after surgery. During the 6 months of follow up, localized lens opacities associated with physical implant contact developed in 66.6% of eyes. CONCLUSION: The surgical procedure using the intravitreal TA sustained delivery device is feasible. Surgical complications were generally mild, with lens opacities attributable to unique anatomical features of the rabbit eye. Long-term follow-up and histology revealed excellent implant tolerability.


Asunto(s)
Implantes de Medicamentos , Glucocorticoides/administración & dosificación , Triamcinolona Acetonida/administración & dosificación , Cuerpo Vítreo/efectos de los fármacos , Animales , Estudios de Factibilidad , Estudios de Seguimiento , Glucocorticoides/efectos adversos , Complicaciones Intraoperatorias , Complicaciones Posoperatorias , Conejos , Retina/efectos de los fármacos , Retina/patología , Esclerostomía/métodos , Triamcinolona Acetonida/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA