Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Orthop ; 57: 17-22, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38948502

RESUMEN

Introduction: Short stem prostheses were originally designed for younger and more active patients. In recent years, they have been increasingly offered to older patients. This study evaluates the mid-to long-term survival of a short stem prosthesis and the changes in periprosthetic bone density following implantation of a cementless short hip stem in patients over 60 years of age. Methods: 118 patients aged over 60 received short stem prostheses. Clinical examination included Harris Hip Score (HHS) and Hip Disability and Osteoarthritis Outcome Score (HOOS). 93 patients were followed clinically for at least five years. 53 patients underwent dual-energy x-ray absorptiometry (DXA) and radiographic evaluation. Follow-up intervals were preoperative and postoperative (t0), at approximately six months (t1), at approximately two years (t2), and at approximately five years or later (t3). Results: Over a mean 6.7-year observation period for all 118 patients, one stem revision occurred due to a traumatic periprosthetic stem fracture. The five-year survival rate for the endpoint survival of the Metha® stem in 95 at-risk patients is 99.2%. HHS improved significantly from t0 55.3 ± 11.5 (range 30-79) to t3 95.3 ± 8.6 (range 57-100) at a mean of 8.0 years (p < 0.001). HOOS improved significantly in each subscale (p < 0.001). Bone mineral density (BMD) was available for review in 53 patients after a mean of 7.1 years. BMD increased from t0 to t3 in region of interest (ROI) 3 (+0.4%) and ROI 6 (+2.9%) and decreased in ROI 1 (-10.3%), ROI 2 (-9.8%), ROI 4 (-5.3%), ROI 5 (-3.4%) and ROI 7 (-23.1%). Conclusions: The evaluated short stem prosthesis shows a remarkably high survival rate in elderly patients, accompanied by excellent clinical results. Load transfer measurements show a metaphyseal-diaphyseal pattern with a trend towards increased diaphyseal transfer over the period observed.

2.
Antibiotics (Basel) ; 12(11)2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37998769

RESUMEN

BACKGROUND: The number of periprosthetic joint infections caused by vancomycin-resistant pathogens is increasing. Currently, no PMMA cement is commercially available to cover VRE. Daptomycin shows promising results in treating infection, offering a good safety profile and a reduced risk of developing resistance. The purpose of this in vitro study was to investigate the mechanical stability, handling properties, elution behavior, and antimicrobial effectiveness of PMMA cement loaded with three different daptomycin concentrations in comparison to commercially available antibiotic-loaded bone cement (ALBC). METHODS: Mechanical properties and handling characteristics (ISO 5833, DIN 53435), HPLC elution, antimicrobial effectiveness with proliferation assay (DIN 17025), and inhibition zone testing were investigated. RESULTS: All tested daptomycin concentrations met the ISO and DIN standards for mechanical strength. Loading of 40 g of PMMA cement with 0.5 g of daptomycin did not show any antimicrobial effectiveness, in contrast to 1.0 g and 1.5 g. PMMA cement with 1.5 g of daptomycin was the best in terms of elution and effectiveness, and it showed good ISO mechanical strength; ISO doughing was sticky for a little longer and setting was faster compared to the vancomycin-containing reference cement. CONCLUSION: PMMA cement containing 0.5 g of gentamicin and 1.5 g of daptomycin could be a good alternative to the already established COPAL® (Wehrheim, Germany) G+V for the treatment of PJIs caused by VRE.

3.
Clin Biomech (Bristol, Avon) ; 109: 106079, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37651899

RESUMEN

BACKGROUND: Preparing the medullary space of the femur aims to create an ideal form-fitting of cementless implants to provide sufficient initial stability, which is crucial for osseous integration, ensuring good long-term results. Hammering the implant into the proximal femur creates a press-fit anchoring of the endoprosthesis in the medullary space. Implanting the optimal size of the shaft for best fitting should avoid damage to the bone. Modified acoustic signals in connection with implantation are being detected by surgeons and might be related to the primary stability of the implant. METHODS: This study aims to explore the relationship between frequency sound patterns and the change in stem stability. For this purpose, n = 32 Metha® short stems were implanted in a clinical setting by the same surgeon. During implantation, the sounds were recorded. To define a change in the acoustic system response during the operation, the individual blows of the implantation sequence were correlated with one another. FINDINGS: An algorithm was able to subdivide through sound analysis two groups of hammer blows (area 1 and area 2) since the characteristics of these groups showed significant differences within the frequency range of 100 Hz to 24 kHz. The edge between both groups, detected by the algorithm, was validated with expert surgeons' classifications of the same data. INTERPRETATION: In conclusion, monitoring, the hammer blows sound might allow quantification of the primary stability of the implant. Sound analysis including patient parameters and a classification algorithm could provide a precise characterization of implant stability.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Diseño de Prótesis , Fémur/cirugía , Acústica
4.
Med Eng Phys ; 119: 104027, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37634907

RESUMEN

Early aseptic loosening following primary total knee arthroplasty related to several factors might appear at the interface implant-cement or cement-bone. A standardized in vitro model might provide information on the relevance of single variable parameter of cementation including technique and cement respectively bone structure on fixation strength. Micromotion measurement using different directions of load should detect the primary stability of the interfaces. An open-cell rigid foam model was used for cementation of PFC-Sigma tibial trays with Palacos®. Pins were applied to the model for continuous non-destructive measurement. Relative micromotions for rotation, valgus-varus and extension flexion stress were detected at the interfaces as well as cement penetration was measured. The reproducibility of the measurement could be shown for all interfaces in extension-flexion movements. For rotation a negative trend was shown for the interface cement-prosthesis and cement-bone concerning varus-valgus stress reflecting varying surgical cementation technique. More micromotion related to extension-flexion force might reflect the design of the implant. Measurement of relative micromotion and cement distribution appear accurate to detect small differences of movement at different interfaces of cemented tibial implants and the results are reproducible for most parameter. An increased number of specimens should achieve statistical relevance for all measurements.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Miembros Artificiales , Reproducibilidad de los Resultados , Cementos para Huesos , Clavos Ortopédicos
5.
Med Eng Phys ; 111: 103932, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36792236

RESUMEN

Aseptic loosening is a frequent cause for revision of endoprosthesis. X-ray examinations like Radio-Stereometry-Analysis (RSA) are among the most widely used in vivo methods for its detection. Nevertheless, this method is not used routinely because of bone marker and related radiation exposure. This work aims at creating a new in vivo concept to detect implant stability measuring micromotions without x-ray and to develop a corresponding algorithm. Based on the assumption of contactless measurement, the input parameters for the algorithm are the distances of each ultrasound sensor to the object (prosthesis and bone) and its position. First, the number of parameters necessary for a precise reconstruction and measurement of micromotions between objects had to be defined. Therefore, the algorithm has been tested with simulations of these parameters. Two experimental measurements, either using contact sensors or ultrasound, were used to prove the accuracy of the algorithm. Simulations indicate a high accuracy with three distances as initial parameters for each object. Contact measurements show precise representation of micromotion, and the contactless measurements show the possibility of detecting various materials with a high resolution. This work lays the foundations for non-invasive detection of micromotions between the implant-bone interface.


Asunto(s)
Prótesis de Cadera , Diseño de Prótesis , Huesos
6.
Clin Biomech (Bristol, Avon) ; 102: 105875, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36634601

RESUMEN

BACKROUND: Surgical treatment of proximal humeral fractures poses a major challenge, especially in osteoporotic bone. At present, there appears to exist neither a suitable model for research to optimize the osteosynthesis processes nor are the structural data available which are required for developing such a model. Therefore, the aim of this study is to determine the microscopic morphology and Young's modulus of cancellous bone from human humeral heads considering osteoporotic changes. METHODS: Cylindrical samples were taken from ten fresh-frozen human humeral heads and structural analysis was done with µCT. Ten rod-like trabeculae were prepared from five of the humeral heads each which were measured and tested mechanically. For this purpose, the trabeculae were fixed on a slide and rotated axially under a stereo microscope. The sample cross-section and the depending moment of inertia were extracted from the image data. The samples were then loaded in a 2-point bending test and Young's moduli of the samples were determined. RESULTS: It could be shown that with increasing age of the donor, ossified portion of the cancellous bone decreased (p < 0.05). The average degree of mineralization of the bone was 1.24 (±0.06) g/mm3, which decreased with increasing age (p < 0.05). The determined Young's modulus averaged 1.33 (±1.76) GPa. INTERPRETATION: The verified structural parameter showed osteoporotic changes in the examined bone. This study for the first time determined Young's modulus of single trabeculae of cancellous bone of osteoporotically altered human humeral heads. Implementing the non-destructive sample measurement before exposure resulted in a methodical improvement.


Asunto(s)
Densidad Ósea , Hueso Esponjoso , Humanos , Módulo de Elasticidad , Fenómenos Biomecánicos , Huesos
7.
AJP Rep ; 11(3): e123-e126, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34603843

RESUMEN

Group B Streptococcus (GBS) disease is a leading cause of invasive bacterial infections among neonates. We present the case of an 11-day-old neonate with septic arthritis as a rare presentation of late-onset disease (LOD) with a favorable short-term outcome. GBS is a leading cause of neonatal infection. Early-onset disease (EOD) is defined as infection from birth to 6 days of age, while LOD occurs from 7 days to approximately 3 months of age. EOD is acquired through vertical transmission and can be reduced through application of intrapartum antibiotic prophylaxis (IAP). LOD can be acquired from the mother or from environmental sources, unlikely to be prevented by IAP. The most common presentation of EOD is bacteremia (83%), pneumonia (9%), and meningitis (7%). While the clinical picture in both EOD and LOD frequently resembles in LOD hamatogenous spreading may predispose neonates to present with uncommon organ manifestation other than the classic systemic signs of sepsis, for example, septic arthritis. Herein, we report on the management and outcome of a term neonate with late onset GqBS bacteremia and subtle clinical symptoms of septic monoarthritis.

8.
J Orthop ; 21: 302-308, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32581456

RESUMEN

INTRODUCTION: Good osteointegration of implants requires sufficient primary stability. Aim of this study was to examine the influence of screw fixation on the primary stability of press-fit cups. METHODS: Two press-fit acetabular cups were tested with regard to the influence and number of screws and their primary stability. RESULTS: For the relatively thin-walled Allofit®-S cup, an influence of the number of screws on the different forms of movement could be demonstrated. CONCLUSIONS: We see a clear influence of the cup wall thickness on the elastic deformability and accordingly on the primary stability of the examined cups.

9.
Cell Tissue Bank ; 21(3): 457-468, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32314113

RESUMEN

Allogeneic bone derived from living donors being necessary to match demand for bone transplantation and thermodisinfection of femoral heads is an established sterilization method. During the thermodisinfection the peripheral bone is exposed to maximum 86 °C for 94 min providing 82.5 °C within the center of the femoral head for at least 15 min. This study examined the compression force of the central and representative peripheral regions of native and thermodisinfected human femoral heads to observe wether different duration and intensity of heat exposure might alter mechanic behaviour. Slices from the equatorial region of human femoral heads were taken from each 14 native and thermodisinfected human femoral heads. The central area revealed a significantly higher compression force for native (p ≤ 0.001) and for thermodisinfected bone (p = 0.002 and p = 0.005) compared with peripheral regions since no relevant differences were found between the peripheral and intermediate areas themselves. A small reduction of compression force for thermodisinfected bone was shown since this did not appear significant due to the small number of specimens. The heat exposure did not alter the pre-existing anatomical changes of the microarchitecture of the native femoral heads from the center towards the peripheral regions. The heterogeneity of microstructure of the femoral head might be of interest concerning clinical applications of bone grafts since the difference between native and thermodisinfected bone appears moderate as shown previously. The different quantity of heat exposure did not reveal any significant influence on compression force which might enable thermodisinfection of preformed bone pieces for surgical indications.


Asunto(s)
Fuerza Compresiva , Desinfección , Cabeza Femoral/patología , Calor , Fenómenos Biomecánicos , Colágeno Tipo I/metabolismo , Humanos
11.
Cell Tissue Bank ; 17(4): 629-642, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27631323

RESUMEN

The rising number of primary joint replacements worldwide causes an increase of revision surgery of endoprostheses due bacterial infection. Revision surgery using non-cemented implants seems beneficial for the long-term outcome and the use of antibiotic-impregnated bone grafts might control the infection and give a good support for the implant. In this study we evaluated the release of antibiotics from fresh-frozen and lyophilized allogeneic bone grafts. Lyophilized bone chips and fresh frozen bone chips were mixed with gentamicin sulphate, gentamicin palmitate, vancomycin, calcium carbonate/calcium sulphate impregnated with gentamicin sulphate, and calcium carbonate/calcium sulphate bone substitute material impregnated with vancomycin. The efficacy of each preparation was measured by drug release tests and bacterial susceptibility using B. subtilis, S. aureus and methicillin-resistant Staphylococcus aureus. The release of gentamicin from lyophilized bone was similar to the release rate from fresh frozen bone during all the experimental time. That fact might be related to the similar porosity and microstructure of the bone chips. The release of gentamicin from lyophilized and fresh frozen bone was high in the first and second day, decreasing and keeping a low rate until the end of the second week. Depending on the surgical strategy either polymethylmethacrylate or allogeneic bone are able to deliver sufficient concentrations of gentamicin to achieve bacterial inhibition within two weeks after surgery. In case of uncemented revision of joint replacements allogeneic bone is able to deliver therapeutic doses of gentamicin and peak levels immediately after implantation during a fortnight. The use of lyophilized and fresh frozen bone allografts as antibiotic carriers is recommended for prophylaxis of bone infection.


Asunto(s)
Antibacterianos/administración & dosificación , Portadores de Fármacos/química , Cabeza Femoral/química , Cabeza Femoral/trasplante , Gentamicinas/administración & dosificación , Vancomicina/administración & dosificación , Aloinjertos/química , Aloinjertos/microbiología , Antibacterianos/farmacología , Bacillus subtilis/efectos de los fármacos , Infecciones Bacterianas/tratamiento farmacológico , Sustitutos de Huesos/química , Trasplante Óseo , Cabeza Femoral/microbiología , Liofilización , Gentamicinas/farmacología , Humanos , Donadores Vivos , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Staphylococcus aureus/efectos de los fármacos , Trasplante Homólogo , Vancomicina/farmacología
12.
Cell Tissue Bank ; 17(3): 427-37, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27344440

RESUMEN

Revision surgery of joint replacements is increasing and raises the demand for allograft bone since restoration of bone stock is crucial for longevity of implants. Proceedings of bone grafts influence the biological and mechanic properties differently. This study examines the effect of thermodisinfection on mechanic properties of cancellous bone. Bone cylinders from both femoral heads with length 45 mm were taken from twenty-three 6-8 months-old piglets, thermodisinfected at 82.5 °C according to bone bank guidelines and control remained native. The specimens were stored at -20 °C immediately and were put into 21 °C Ringer's solution for 3 h before testing. Shear and pressure modulus were tested since three point bending force was examined until destruction. Statistical analysis was done with non-parametric Wilcoxon, t test and SPSS since p < 0.05 was significant. Shear modulus was significantly reduced by thermodisinfection to 1.02 ± 0.31 GPa from 1.28 ± 0.68 GPa for unprocessed cancellous bone (p = 0.029) since thermodisinfection reduced pressure modulus not significantly from 6.30 ± 4.72 GPa for native specimens to 4.97 ± 2.23 GPa and maximum bending force was 270.03 ± 116.68 N for native and 228.80 ± 70.49 N for thermodisinfected cancellous bone. Shear and pressure modulus were reduced by thermodisinfection around 20 % and maximum bending force was impaired by about 15 % compared with native cancellous bone since only the reduction of shear modulus reached significance. The results suggest that thermodisinfection similarly affects different mechanic properties of cancellous bone and the reduction of mechanic properties should not relevantly impair clinical use of thermodisinfected cancellous bone.


Asunto(s)
Hueso Esponjoso/fisiología , Desinfección/métodos , Temperatura , Animales , Fenómenos Biomecánicos , Estrés Mecánico , Sus scrofa , Torsión Mecánica , Soporte de Peso
13.
Arch Orthop Trauma Surg ; 136(4): 585-92, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26873243

RESUMEN

INTRODUCTION: Treatment of implant-associated osteomyelitis regularly involves the use of systemic antibiotics in addition to surgical intervention. However, it remains unclear if perioperative systemic application of bactericide substances can improve overall outcome in models of severe intramedullary infection. The present study investigated the use of systemic gentamicin in addition to a controlled local release from a highly lipophilic gentamicinpalmitate compound while the previous study showed efficacy of sole antibiotic implant-coating. METHODS: Forty male Sprague-Dawley rats were divided into two groups receiving an intramedullary femoral injection of 10(2) CFU of a common methicillin susceptible Staphylococcus aureus strain (MSSA Rosenbach). Group I received an uncoated implant whereas group II received a coated implant. All animals received a single shot intraperitoneal application of gentamicinsulfate directly after wound closure while the historical control group III (n = 20) had no antibiotic treatment at all. Animals were observed for 28 and 42 days. Serum haptoglobin and relative weight gain were assessed as well as roll over cultures of explanted femur nails and histological scores of periprosthetic infection in dissected femora. RESULTS: Systemic application of gentamicin combined with antibiotic-coated implant did not further reduce bacterial growth significantly compared with systemic or local antibiotic application alone. Combined local and systemic therapy reduced serum haptoglobin significantly after day 7, 28 and 42 whereas systemic application alone did not compare to controls. CONCLUSIONS: Systemic perioperative and implant-associated application of antibiotics were both comparably effective to treat implant-associated infections whereas the combined antibiotic therapy further reduced systemic signs of infection time dependent.


Asunto(s)
Antibacterianos/administración & dosificación , Artroplastia de Reemplazo de Rodilla/instrumentación , Gentamicinas/administración & dosificación , Prótesis de la Rodilla/efectos adversos , Osteomielitis/prevención & control , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones Estafilocócicas/prevención & control , Animales , Antibacterianos/uso terapéutico , Gentamicinas/uso terapéutico , Inyecciones Intraperitoneales , Masculino , Osteomielitis/etiología , Infecciones Relacionadas con Prótesis/etiología , Ratas , Ratas Sprague-Dawley , Infecciones Estafilocócicas/etiología , Resultado del Tratamiento
14.
Int Orthop ; 39(5): 981-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25380688

RESUMEN

PURPOSE: Implant-associated osteomyelitis still represents a demanding challenge due to unfavourable biological conditions, bacterial properties and incremental resistance to antibiotic treatment. Therefore different bactericide or bacteriostatic implant coatings have been developed recently to control local intramedullary infections. Controlled local release of gentamicin base from a highly lipophilic gentamicin palmitate compound achieves extended intramedullary retention times and thus may improve its bactericide effect. METHODS: Forty male Sprague-Dawley rats were divided into two groups receiving an intramedullary femoral injection of 10(2) colony-forming units (CFU) of a common methicillin susceptible Staphylococcus aureus strain (MSSA Rosenbach) and either an uncoated femur nail (Group I) or a nail coated with gentamicin palmitate (Group II). Animals were observed for 28 and 42 days. Serum haptoglobin and relative weight gain were assessed as well as rollover cultures of explanted femur nails and histological scores of periprosthetic infection in dissected femurs. RESULTS: Implants coated with gentamicin palmitate significantly reduced periprosthetic bacterial growth as well as signs of systemic inflammation compared with uncoated implants. CONCLUSIONS: Gentamicin palmitate appears to be a viable coating for the prevention of implant-associated infections. These findings will have to be confirmed in larger animal models as well as in clinical trials.


Asunto(s)
Gentamicinas/administración & dosificación , Osteomielitis/prevención & control , Infecciones Relacionadas con Prótesis/prevención & control , Animales , Antibacterianos/administración & dosificación , Antibacterianos/uso terapéutico , Profilaxis Antibiótica/métodos , Materiales Biocompatibles Revestidos/administración & dosificación , Modelos Animales de Enfermedad , Masculino , Osteomielitis/microbiología , Infecciones Relacionadas con Prótesis/microbiología , Ratas Sprague-Dawley , Infecciones Estafilocócicas/prevención & control
15.
Cytotherapy ; 17(2): 152-62, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25453724

RESUMEN

BACKGROUND AIMS: The discovery of regenerative and immunosuppressive capacities of mesenchymal stromal cells (MSCs) raises hope for patients with tissue-damaging or severe, treatment-refractory autoimmune disorders. We previously presented a method to expand human MSCs in a bioreactor under standardized Good Manufacturing Practice conditions. Now we characterized the impact of critical treatment conditions on MSCs with respect to immunosuppressive capabilities and proliferation. METHODS: MSC proliferation and survival after γ irradiation were determined by 5-carboxyfluorescein diacetate N-succinimidyl ester and annexinV/4',6-diamidino-2-phenylindole (DAPI) staining, respectively. T-cell proliferation assays were used to assess the effect of γ irradiation, passaging, cryopreservation, post-thaw equilibration time and hypoxia on T-cell suppressive capacities of MSCs. Quantitative polymerase chain reaction and ß-galactosidase staining served as tools to investigate differences between immunosuppressive and non-immunosuppressive MSCs. RESULTS: γ irradiation of MSCs abrogated their proliferation while vitality and T-cell inhibitory capacity were preserved. Passaging and long cryopreservation time decreased the T-cell suppressive function of MSCs, and postthaw equilibration time of 5 days restored this capability. Hypoxic culture markedly increased MSC proliferation without affecting their T-cell-suppressive capacity and phenotype. Furthermore, T-cell suppressive MSCs showed higher CXCL12 expression and less ß-galactosidase staining than non-suppressive MSCs. DISCUSSION: We demonstrate that γ irradiation is an effective strategy to abrogate MSC proliferation without impairing the cells' immunosuppressive function. Hypoxia significantly enhanced MSC expansion, allowing for transplantation of MSCs with low passage number. In summary, our optimized MSC expansion protocol successfully addressed the issues of safety and preservation of immunosuppressive MSC function after ex vivo expansion for therapeutic purposes.


Asunto(s)
Hipoxia de la Célula/fisiología , Proliferación Celular/efectos de la radiación , Rayos gamma/efectos adversos , Trasplante de Células Madre Mesenquimatosas/métodos , Células Madre Mesenquimatosas/efectos de la radiación , Adulto , Células Cultivadas , Quimiocina CXCL12/biosíntesis , Criopreservación , Fluoresceínas , Humanos , Terapia de Inmunosupresión/métodos , Inmunosupresores/efectos de la radiación , Activación de Linfocitos/inmunología , Activación de Linfocitos/efectos de la radiación , Células Madre Mesenquimatosas/citología , Persona de Mediana Edad , Linfocitos T/inmunología , beta-Galactosidasa/metabolismo
16.
Cell Tissue Bank ; 16(1): 73-81, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24692177

RESUMEN

Thermodisinfection of human femoral heads from living donors harvested during hip joint replacement is an established processing procedure. This study was designed to examine the influence of heat sterilization on pull out strength of cancellous bone and storage at different temperatures up to 2 years since we had previously studied the storage of unprocessed cancellous bone. Porcine cancellous bone resembling human bone structure was obtained from 140 proximal humerus of 6-8 months old piglets. Pull out strength of screws after thermodisinfection was compared with unprocessed cancellous bone and tested immediately and after 6, 12 and 24 months of storage at -20 and -80 °C. A three-way ANOVA was performed and significance level was 5 %. The thermodisinfected bone showed a pull out force of 2729 N (1657-3568 N). The reduction of pull out strength compared with unprocessed bone over all periods of storage was 276 N on average with 95 % confidence interval ranging from 166 N to 389 N (p < 0.0001). Different freezing temperatures did not influence this mechanic property within 24 months storage and showed no difference compared with fresh frozen bone. Thermodisinfection of cancellous bone preserves tensile strength necessary for clinical purposes. The storage at -20 °C for at least 2 years did not show relevant decrease of pull out strength compared with -80 °C without difference between thermodisinfected and fresh frozen bone. The increase of the storage temperature to -20 °C for at least 2 years should be considered.


Asunto(s)
Trasplante Óseo , Criopreservación , Desinfección/métodos , Animales , Cabeza Femoral , Humanos , Donadores Vivos , Porcinos , Temperatura
17.
Biomed Tech (Berl) ; 57(6): 473-80, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23152399

RESUMEN

BACKGROUND: Cement augmentation of pedicle screws increases fixation strength in an osteoporotic spine. This study was designed to determine the cement distribution and the correlation between the pull-out strength of the augmented screw and the cement volume within polyurethane (PU) foam. METHODS: Twenty-eight cannulated pedicle screws (6×45 mm) (Peter Brehm, Erlangen, Germany) with four holes at the distal end of the screw were augmented with the acrylic Stabilit ER Bone Cement Vertebral Augmentation System (DFine Inc., San Jose, CA, USA) and implanted into open-cell rigid PU foam (Pacific Research Laboratories, Vashon Island, WA, USA) with a density of 0.12 g/cm3, resembling severe osteoporosis. Volumetric measurement of the cement with consideration of the distribution around the screws was done with multislice computed tomography scan (Somatom Definition, Siemens, Erlangen, Germany). Pull-out strength was tested with a servohydraulic system (MTS System Corporation, Eden Prairie, MN, USA), and nonaugmented screws served as control. Pearson's correlation coefficient with significance level α=0.05 and one-way analysis of variance test were used. RESULTS: We found a high (r=0.88) and significant (p<0.01) correlation between the cement volume and the pull-out strength, which increased by more than 5-fold with a volume of 3 ml. The correlation appeared linear at least up to 4 ml cement volume and failure always occurred at the cement-bone interface. The cement distribution was symmetric and circular around the most proximal hole, with a distance of 14 mm from the tip, and nearly 90% of the cement was found 6 mm distal and cranial to it. The 95% confidence interval for the relative amount of cement was 37%-41% within 2 mm of the most proximal hole. CONCLUSION: Compared with the control, a cement volume between 2.0 and 3.0 ml increased the pull-out strength significantly and is relevant for clinical purposes, whereas a volume of 0.5 ml did not. A cement volume beyond 3.0 ml should further increase the pull-out strength because the correlation was linear at least up to 4.0 ml, but the possibility of in vivo cement leakage with increasing volume has to be considered. Pressure-controlled cement application might be a tool to avoid this complication. The cement almost completely penetrated the most proximal perforation.


Asunto(s)
Cementos para Huesos/uso terapéutico , Tornillos Óseos , Huesos/fisiopatología , Huesos/cirugía , Osteoporosis/fisiopatología , Osteoporosis/cirugía , Huesos/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Análisis de Falla de Equipo , Fricción/efectos de los fármacos , Dureza/efectos de los fármacos , Humanos , Ensayo de Materiales , Diseño de Prótesis , Estadística como Asunto , Resistencia a la Tracción/efectos de los fármacos
18.
Transfus Med Hemother ; 39(1): 36-40, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22896765

RESUMEN

BACKGROUND: The recommendations for storage temperature of allogeneic bone are varying between -20 °C and -70 °C and down to -80 °C. The necessary temperature of storage is not exactly defined by scientific data, and the effect of different storage temperatures onto the biomechanical and the biological behavior is discussed controversially. METHODS: The historical development of storage temperature of bone banks is described. A survey on literature concerning the biomechanical and biological properties of allograft bone depending on the procurement and storage temperature is given as well as on national and international regulations on storage conditions of bone banks (European Council, American Association of Tissue Banks (AATB), European Association of Tissue Banks (EATB)). RESULTS: Short-term storage up to 6 months is recommended with -20 °C and -40 °C for a longer period (AATB), and EATB recommends storage at -40 °C and even -80 °C while the regulations of the German German Medical Association (Bundesärztekammer) from 2001 recommend storage at -70 °C. Duration of storage at -20 °C can be maintained at least for 2 years. The potential risk of proteolysis with higher storage temperatures remains, but a definite impairment of bone ingrowth due to a storage at -20 °C was not shown in clinical use, and no adverse biomechanical effects of storage at -20 °C could be proven. CONCLUSION: Biomechanical studies showed no clinically relevant impairment of biomechanical properties of cancellous bone due to different storage temperatures. Sterilization procedures bear the advantage of inactivating enzymatic activity though reducing the risk of proteolysis. In those cases a storage temperature of -20 °C can be recommended for at least a period of 2 years, and the risk of undesired effects seems to be low for native unprocessed bone.

19.
PM R ; 4(5): 335-41, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22464951

RESUMEN

OBJECTIVE: To explore the reliability of the Zebris CMS 20 ultrasound analysis system with pointer application for measuring end-range flexion, end-range extension, and neutral kyphosis angle of the thoracic spine. SETTING: The study was performed within the School of Physiotherapy in cooperation with the Orthopedic Department at a University Hospital. PARTICIPANTS: The thoracic spines of 28 healthy subjects were measured. METHODS: Measurements for neutral kyphosis angle, end-range flexion, and end-range extension were taken once at each time point. The bone landmarks were palpated by one examiner and marked with a pointer containing 2 transmitters using a frequency of 40 kHz. A third transmitter was fixed to the pelvis, and 3 microphones were used as receiver. The real angle was calculated by the software. Bland-Altman plots with 95% limits of agreement, intraclass correlations (ICC), standard deviations of mean measurements, and standard error of measurements were used for statistical analyses. The test-retest reliability in this study was measured within a 24-hour interval. MAIN OUTCOME MEASUREMENTS: Statistical parameters were used to judge reliability. RESULTS: The mean kyphosis angle was 44.8° with a standard deviation of 17.3° at the first measurement and a mean of 45.8° with a standard deviation of 16.2° the following day. The ICC was high at 0.95 for the neutral kyphosis angle, and the Bland-Altman 95% limits of agreement were within clinical acceptable margins. The ICC was 0.71 for end-range flexion and 0.34 for end-range extension, whereas the Bland-Altman 95% limits of agreement were wider than with the static measurement of kyphosis. Compared with static measurements, the analysis of motion with 3-dimensional ultrasound showed an increased standard deviation for test-retest measurements. CONCLUSIONS: The test-retest reliability of ultrasound measuring of the neutral kyphosis angle of the thoracic spine was demonstrated within 24 hours. Bland-Altman 95% limits of agreement and the standard deviation of differences did not appear to be clinically acceptable for measuring flexion and extension.


Asunto(s)
Imagenología Tridimensional/métodos , Cifosis/diagnóstico por imagen , Vértebras Torácicas/diagnóstico por imagen , Adulto , Femenino , Estudios de Seguimiento , Humanos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...