1.
Eur J Radiol ; 127: 108980, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32320912

RESUMEN

PURPOSE: In addition to a breast density category, temporal changes in breast density have gained attention as a dynamic breast cancer risk marker. This case-control study aimed to investigate a potential change in breast density preceding tumor development and the relationship of this potential change to prognostic pathological tumor variables. METHOD: A total of 51 consecutive, eligible-for-analyses, biopsy-proven breast cancers were diagnosed between 1 st of August and 31 st of December 2014 at Skåne University Hospital, Sweden. Mammogram data and patient- and tumor characteristics were retrieved retrospectively from medical charts. Breast density was quantitatively estimated using LIBRA (a free open source software package). The cases were matched for year of birth, number of screening rounds, and date for first and last mammograms with controls from the Malmö Breast Tomosynthesis Screening Trial in a 1:2 ratio, resulting in median time between mammograms of 4.5 (1.3-11.9) years for cases and 4.7 (1.4-11.1) years for controls, averaging approximately three screening rounds (1-6 rounds). RESULTS: We detected a statistically significant difference in breast density change over time, with cases showing an increase in breast density (1.7 %) as compared to controls (-0.3 %) (p = 0.045). We found that in women with breast cancer, older women (≥ 55 years) experienced a higher breast density increase compared to younger women (5.1 % vs. 0.3 %, p = 0.002). CONCLUSIONS: There was a statistically significant difference in density change, where women with breast cancer showed an increased density over time, which was particularly evident in women > 55 years of age.


Asunto(s)
Densidad de la Mama , Neoplasias de la Mama/diagnóstico por imagen , Mamografía/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Estudios de Casos y Controles , Femenino , Humanos , Mamografía/estadística & datos numéricos , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Suecia
2.
Eur J Radiol ; 116: 21-26, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31153567

RESUMEN

PURPOSE: To assess the effect on reducing the out-of-plane artifacts from metal objects in breast tomosynthesis (BT) using a novel artifact-reducing reconstruction algorithm in specimen radiography. METHODS AND MATERIALS: The study was approved by the Regional Ethical Review Board. BT images of 18 partial- and whole mastectomy specimens from women with breast cancer were acquired before and after a needle was inserted close to the lesion. The images were reconstructed using both a standard reconstruction algorithm, and a novel algorithm; the latter uses pre-segmentation to remove highly attenuating artifact-inducing objects from projection images before reconstruction. Images were separately reconstructed with and without segmentation, and combined into an artifact-reduced reconstruction. Standard and artifact-reduced BT-algorithms were compared visually and quantitatively using clinical images of mastectomy specimens and a physical anthropomorphic phantom. Six readers independently assessed the visibility of the lesion with and without artifact-reduction in a side-by-side comparison. A quantitative analysis was performed, comparing the signal-difference to background ratio (SDBR) and artifact spread function (ASF) between the two reconstruction methods. RESULTS: The magnitude of out-of-plane artifacts was clearly reduced with the novel reconstruction compared to BT-images without artifact reduction. Lesion masking by artifacts was largely averted; tumour visibility was comparable to standard BT images without a needle. In 76 ± 8% (standard deviation) of cases overall, readers could confidently state needle location. The same figure was 94 ± 6% for whole mastectomy cases, compared to 62 ± 17% for partial mastectomies. With metal artifact reduction, SDBR increased by 97% in the phantom, and by 69% in the mastectomies. The artifact spread function was substantially narrower. CONCLUSION: Artifact reduction in BT using a novel reconstruction method enables qualitatively and quantitatively improved clinical use of BT when metal artifacts can be a limiting factor such as in tomosynthesis-guided biopsy.


Asunto(s)
Algoritmos , Artefactos , Neoplasias de la Mama/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Mamografía/métodos , Biopsia , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Femenino , Humanos , Mastectomía , Metales
3.
J Med Imaging (Bellingham) ; 6(3): 031406, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30746394

RESUMEN

Assessment of breast density at the point of mammographic examination could lead to optimized breast cancer screening pathways. The onsite breast density information may offer guidance of when to recommend supplemental imaging for women in a screening program. A software application (Insight BD, Siemens Healthcare GmbH) for fast onsite quantification of volumetric breast density is evaluated. The accuracy of the method is assessed using breast tissue equivalent phantom experiments resulting in a mean absolute error of 3.84%. Reproducibility of measurement results is analyzed using 8427 exams in total, comparing for each exam (if available) the densities determined from left and right views, from cranio-caudal and medio-lateral oblique views, from full-field digital mammograms (FFDM) and digital breast tomosynthesis (DBT) data and from two subsequent exams of the same breast. Pearson correlation coefficients of 0.937, 0.926, 0.950, and 0.995 are obtained. Consistency of the results is demonstrated by evaluating the dependency of the breast density on women's age. Furthermore, the agreement between breast density categories computed by the software with those determined visually by 32 radiologists is shown by an overall percentage agreement of 69.5% for FFDM and by 64.6% for DBT data. These results demonstrate that the software delivers accurate, reproducible, and consistent measurements that agree well with the visual assessment of breast density by radiologists.

5.
Eur Radiol ; 29(1): 330-336, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29943180

RESUMEN

OBJECTIVES: To compare software estimates of volumetric breast density (VBD) based on breast tomosynthesis (BT) projections to those based on digital mammography (DM) images in a large screening cohort, the Malmö Breast Tomosynthesis Screening Trial (MBTST). METHODS: DM and BT images of 9909 women (enrolled 2010-2015) were retrospectively analysed with prototype software to estimate VBD. Software calculation is based on a physics model of the image acquisition process and incorporates the effect of masking in DM based on accumulated dense tissue areas. VBD (continuously and categorically) was compared between BT [central projection (mediolateral oblique view (MLO)] and two-view DM, and with radiologists' BI-RADS density 4th ed. scores. Agreement and correlation were investigated with weighted kappa (κ), Spearman's correlation coefficient (r), and Bland-Altman analysis. RESULTS: There was a high correlation (r = 0.83) between VBD in DM and BT and substantial agreement between the software breast density categories [observed agreement, 61.3% and 84.8%; κ = 0.61 and ĸ = 0.69 for four (a/b/c/d) and two (fat involuted vs. dense) density categories, respectively]. There was moderate agreement between radiologists' BI-RADS scores and software density categories in DM (ĸ = 0.55) and BT (ĸ = 0.47). CONCLUSIONS: In a large public screening setting, we report a substantial agreement between VBD in DM and BT using software with special focus on masking effect. This automated and objective mode of measuring VBD may be of value to radiologists and women when BT is used as the primary breast cancer screening modality. KEY POINTS: • There was a high correlation between continuous volumetric breast density in DM and BT. • There was substantial agreement between software breast density categories (four groups) in DM and BT; with clinically warranted binary software breast density categories, the agreement increased markedly. • There was moderate agreement between radiologists' BI-RADS scores and software breast density categories in DM and BT.


Asunto(s)
Densidad de la Mama , Neoplasias de la Mama/diagnóstico , Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Programas Informáticos , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC
6.
Lancet Oncol ; 19(11): 1493-1503, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30322817

RESUMEN

BACKGROUND: Digital breast tomosynthesis is an advancement of the mammographic technique, with the potential to increase detection of lesions during breast cancer screening. The main aim of the Malmö Breast Tomosynthesis Screening Trial (MBTST) was to investigate the accuracy of one-view digital breast tomosynthesis in population screening compared with standard two-view digital mammography. METHODS: In this prospective, population-based screening study, of women aged 40-74 years invited to attend national breast cancer screening at Skåne University Hospital, Malmö, Sweden, a random sample was asked to participate in the trial (every third woman who was invited to attend regular screening was invited to participate). Participants had to be able to speak English or Swedish and were excluded from the study if they were pregnant. Participants underwent screening with two-view digital mammography (ie, craniocaudal and mediolateral oblique views) followed by one-view digital breast tomosynthesis with reduced compression in the mediolateral oblique view (with a wide tomosynthesis angle of 50°) at one screening visit. Images were read with masked double reading and scoring by two separate reading groups, one for each method, made up of seven radiologists. Any cancer detected with a malignancy probability score of three or higher by any reader in either group was discussed in a consensus meeting of at least two readers, from which the decision of whether or not to recall the woman for further investigation was made. The primary outcome measures were sensitivity and specificity of breast cancer detection. Secondary outcome measures were screening performance measures of cancer detection, recall, and interval cancers (cancers clinically detected between screenings), and positive predictive value for screen recalls and negative predictive value of each method. Outcomes were analysed in the per-protocol population. Follow-up of the participants for at least 2 years allowed for identification of interval cancers. This trial is registered with ClinicalTrials.gov, number NCT01091545. FINDINGS: Between Jan 27, 2010, and Feb 13, 2015, of 21 691 women invited, 14 851 (68%) agreed to participate. Three women withdrew consent during follow-up and were excluded from the analyses. 139 breast cancers were detected in 137 (<1%) of 14 848 women. Sensitivity was higher for digital breast tomosynthesis than for digital mammography (81·1%, 95% CI 74·2-86·9, vs 60·4%, 52·3-68·0) and specificity was slightly lower for digital breast tomosynthesis than was for digital mammography (97·2%, 95% CI 97·0-97·5, vs 98·1%, 97·9-98·3). The proportion of cancers detected was significantly higher with digital breast tomosynthesis than with digital mammography (8·7 cancers per 1000 women screened, 95% CI 7·3-10·3 vs 6·5 cancers per 1000 screened, 5·2-7·9; p<0·0001). The proportion of women recalled after discussion was higher among cancers detected by digital breast tomosynthesis than for those detected by digital mammography after consensus (3·6%, 95% CI 3·3-3·9 vs 2·5%, 2·2-2·8; p<0·0001). The positive predictive value for screen recalls was 24·1% (95% CI 20·5-28·0) for digital breast tomosynthesis and 25·9% (21·6-30·7) for digital mammography, and the negative predictive value was 99·8% (99·7-99·9) and 99·6% (99·4-99·7), respectively. The proportion of women who developed interval cancers after trial screening was 1·48 cancers per 1000 women screened (95% CI 0·93-2·24). INTERPRETATION: Breast cancer screening by use of one-view digital breast tomosynthesis with a reduced compression force has higher sensitivity at a slightly lower specificity for breast cancer detection compared with two-view digital mammography and has the potential to reduce the radiation dose and screen-reading burden required by two-view digital breast tomosynthesis with two-view digital mammography. FUNDING: The Swedish Cancer Society, The Swedish Research Council, The Breast Cancer Foundation, The Swedish Medical Society, The Crafoord Foundation, The Gunnar Nilsson Cancer Foundation, The Skåne University Hospital Foundation, Governmental funding for clinical research, The South Swedish Health Care Region, The Malmö Hospital Cancer Foundation and The Cancer Foundation at the Department of Oncology, Skåne University Hospital.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Suecia
7.
Med Phys ; 45(7): 3019-3030, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29704868

RESUMEN

PURPOSE: The task-based assessment of image quality using model observers is increasingly used for the assessment of different imaging modalities. However, the performance computation of model observers needs standardization as well as a well-established trust in its implementation methodology and uncertainty estimation. The purpose of this work was to determine the degree of equivalence of the channelized Hotelling observer performance and uncertainty estimation using an intercomparison exercise. MATERIALS AND METHODS: Image samples to estimate model observer performance for detection tasks were generated from two-dimensional CT image slices of a uniform water phantom. A common set of images was sent to participating laboratories to perform and document the following tasks: (a) estimate the detectability index of a well-defined CHO and its uncertainty in three conditions involving different sized targets all at the same dose, and (b) apply this CHO to an image set where ground truth was unknown to participants (lower image dose). In addition, and on an optional basis, we asked the participating laboratories to (c) estimate the performance of real human observers from a psychophysical experiment of their choice. Each of the 13 participating laboratories was confidentially assigned a participant number and image sets could be downloaded through a secure server. Results were distributed with each participant recognizable by its number and then each laboratory was able to modify their results with justification as model observer calculation are not yet a routine and potentially error prone. RESULTS: Detectability index increased with signal size for all participants and was very consistent for 6 mm sized target while showing higher variability for 8 and 10 mm sized target. There was one order of magnitude between the lowest and the largest uncertainty estimation. CONCLUSIONS: This intercomparison helped define the state of the art of model observer performance computation and with thirteen participants, reflects openness and trust within the medical imaging community. The performance of a CHO with explicitly defined channels and a relatively large number of test images was consistently estimated by all participants. In contrast, the paper demonstrates that there is no agreement on estimating the variance of detectability in the training and testing setting.