1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 29(1): 13-6, 37, 2005 Jan.
Artículo en Chino | MEDLINE | ID: mdl-15875685

RESUMEN

A portable ECG monitor is introduced in the paper, which has a temporary intravenous and transesophageal fixable rate pacing function. During the PSVT attack, the tachyarrythmia can be stopped by the transesophageal cardiac pacing while the ECG signals are monitored. The instrument has some advantages such as small size, low price and good practicality. It is worth while introducing and popularizing it to all hospitals.


Asunto(s)
Electrocardiografía Ambulatoria , Monitoreo Ambulatorio/instrumentación , Marcapaso Artificial , Procesamiento de Señales Asistido por Computador , Electrocardiografía Ambulatoria/instrumentación , Diseño de Equipo , Bloqueo Cardíaco/diagnóstico , Bloqueo Cardíaco/terapia , Frecuencia Cardíaca , Humanos , Marcapaso Artificial/clasificación , Programas Informáticos , Taquicardia/diagnóstico , Taquicardia/terapia
2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 21(5): 819-23, 2004 Oct.
Artículo en Chino | MEDLINE | ID: mdl-15553866

RESUMEN

Polygraph has become a necessary instrument in interventional cardiology and fundamental research of medicine up to the present. In this study, a LabView development system (DS) (developed by NI in U.S.) used as software platform, a DAQ data acquisition module and universal computer used as hardware platform, were creatively coupled with our self-made low noise multi-channels preamplifier to develop Multi-channels electrocardiograph. The device possessed the functions such as real time display of physiological process, digit highpass and lowpass, 50Hz filtered and gain adjustment, instant storing, random playback and printing, and process control stimulation. Besides, it was small-sized, economically practical and easy to operate. It could advance the spread of cardiac intervention treatment in hospitals.


Asunto(s)
Electrocardiografía/instrumentación , Monitoreo Intraoperatorio , Procesamiento de Señales Asistido por Computador , Monitoreo Fisiológico , Programas Informáticos
3.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 21(4): 650-3, 2004 Aug.
Artículo en Chino | MEDLINE | ID: mdl-15357453

RESUMEN

A temporary demand pacemaker with electrocardiosignal display is introduced in this paper. Double way low-noise electrocardiosignal preamplifier, amplitude limiter, high and low pass filter, 50 Hz notch filter, TTL level generator and stimulating pulse formation circuit are components of the hardware electrocircuit. The demand pacing and the electrocardiosignal display are separately controlled by the software in which the double microcontrollers communications technique is used. In this study, liquid crystal display is firstly used in body surface electrocardiosignal display or intracardial electrophysiologic signal display when the temporary demand pacemaker is installed and put into use. The machine has proven clinically useful and can be of wide appliation.


Asunto(s)
Electrocardiografía , Marcapaso Artificial , Humanos