Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Breast Cancer Res Treat ; 198(3): 573-582, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36802316

RESUMEN

PURPOSE: Accurate evaluation of breast cancer on bioptic samples is of fundamental importance to guide therapeutic decisions, especially in the neoadjuvant or metastatic setting. We aimed to assess concordance for oestrogen receptor (ER), progesterone receptor (PR), c-erbB2/HER2 and Ki-67. We also reviewed the current literature to evaluate our results in the context of the data available at present. METHODS: We included patients who underwent both biopsy and surgical resection for breast cancer at San Matteo Hospital, Pavia, Italy, between January 2014 and December 2020. ER, PR, c-erbB2, and Ki-67 immunohistochemistry concordance between biopsy and surgical specimen was evaluated. ER was further analysed to include the recently defined ER-low-positive in our analysis. RESULTS: We evaluated 923 patients. Concordance between biopsy and surgical specimen for ER, ER-low-positive, PR, c-erbB2 and Ki-67 was, respectively, 97.83, 47.8, 94.26, 68 and 86.13%. Cohen's κ for interobserver agreement was very good for ER and good for PR, c-erbB2 and Ki-67. Concordance was especially low (37%) in the c-erbB2 1 + category. CONCLUSION: Oestrogen and progesterone receptor status can be safely assessed on preoperative samples. The results of this study advise caution in interpreting biopsy results regarding ER-low-positive, c-erbB2/HER and Ki-67 results due to a still suboptimal concordance. The low concordance for c-erbB2 1 + cases underlines the importance of further training in this area, in the light of the future therapeutic perspectives.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/cirugía , Neoplasias de la Mama/tratamiento farmacológico , Receptores de Progesterona , Antígeno Ki-67 , Biomarcadores de Tumor , Pronóstico , Inmunohistoquímica , Receptor ErbB-2 , Biopsia , Receptores de Estrógenos
2.
Eur Radiol ; 32(11): 7388-7399, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35648209

RESUMEN

OBJECTIVES: To evaluate the potential of contrast-enhanced mammography (CEM) for reducing the biopsy rate of screening recalls. METHODS: Recalled women were prospectively enrolled to undergo CEM alongside standard assessment (SA) through additional views, tomosynthesis, and/or ultrasound. Exclusion criteria were symptoms, implants, allergy to contrast agents, renal failure, and pregnancy. SA and CEM were independently evaluated by one of six radiologists, who recommended biopsy or 2-year follow-up. Biopsy rates according to SA or recombined CEM (rCEM) were compared with the McNemar's test. Diagnostic performance was calculated considering lesions with available final histopathology. RESULTS: Between January 2019 and July 2021, 220 women were enrolled, 207 of them (median age 56.6 years) with 225 suspicious findings analysed. Three of 207 patients (1.4%) developed mild self-limiting adverse reactions to iodinated contrast agent. Overall, 135/225 findings were referred for biopsy, 90/225 by both SA and rCEM, 41/225 by SA alone and 4/225 by rCEM alone (2/4 being one DCIS and one invasive carcinoma). The rCEM biopsy rate (94/225, 41.8%, 95% CI 35.5-48.3%) was 16.4% lower (p < 0.001) than the SA biopsy rate (131/225, 58.2%, 95% CI 51.7-64.5%). Considering the 124/135 biopsies with final histopathology (44 benign, 80 malignant), rCEM showed a 93.8% sensitivity (95% CI 86.2-97.3%) and a 65.9% specificity (95% CI 51.1-78.1%), all 5 false negatives being ductal carcinoma in situ detectable as suspicious calcifications on low-energy images. CONCLUSIONS: Compared to SA, the rCEM-based work-up would have avoided biopsy for 37/225 (16.4%) suspicious findings. Including low-energy images in interpretation provided optimal overall CEM sensitivity. KEY POINTS: • The work-up of suspicious findings detected at mammographic breast cancer screening still leads to a high rate of unnecessary biopsies, involving between 2 and 6% of screened women. • In 207 recalled women with 225 suspicious findings, recombined images of contrast-enhanced mammography (CEM) showed a 93.8% sensitivity and a 65.9% specificity, all 5 false negatives being ductal carcinoma in situ detectable on low-energy images as suspicious calcifications. • CEM could represent an easily available one-stop shop option for the morphofunctional assessment of screening recalls, potentially reducing the biopsy rate by 16.4%.


Asunto(s)
Neoplasias de la Mama , Calcinosis , Carcinoma Intraductal no Infiltrante , Humanos , Femenino , Persona de Mediana Edad , Carcinoma Intraductal no Infiltrante/patología , Mamografía/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Detección Precoz del Cáncer/métodos , Calcinosis/patología , Medios de Contraste/farmacología
3.
Cancers (Basel) ; 13(4)2021 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-33670739

RESUMEN

Background: Considering highly selected patients with ductal carcinoma in situ (DCIS), active surveillance is a valid alternative to surgery. Our study aimed to show the reliability of post-biopsy complete lesion removal, documented by mammogram, as additional criterion to select these patients. Methods: A total of 2173 vacuum-assisted breast biopsies (VABBs) documented as DCIS were reviewed. Surgery was performed in all cases. We retrospectively collected the reports of post-VABB complete lesion removal and the histological results of the biopsy and surgery. We calculated the rate of upgrade of DCIS identified on VABB upon excision for patients with post-biopsy complete lesion removal and for those showing residual lesion. Results: We observed 2173 cases of DCIS: 408 classified as low-grade, 1262 as intermediate-grade, and 503 as high-grade. The overall upgrading rate to invasive carcinoma was 15.2% (330/2173). The upgrade rate was 8.2% in patients showing mammographically documented complete removal of the lesion and 19% in patients without complete removal. Conclusion: The absence of mammographically documented residual lesion following VABB was found to be associated with a lower upgrading rate of DCIS to invasive carcinoma on surgical excision and should be considered when deciding the proper management DCIS diagnosis.

4.
Eur Radiol ; 31(2): 920-927, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32816199

RESUMEN

PURPOSE: Breast lesions classified as of "uncertain malignant potential" represent a heterogeneous group of abnormalities with an increased risk of associated malignancy. Clinical management of B3 lesions diagnosed on vacuum-assisted breast biopsy (VABB) is still challenging: surgical excision is no longer the only available treatment and VABB may be sufficient for therapeutic excision. The aim of the present study is to evaluate the positive predictive value (PPV) for malignancy in B3 lesions that underwent surgical excision, identifying possible upgrading predictive factors and characterizing the malignant lesions eventually diagnosed. These results are compared with a subset of patients with B3 lesions who underwent follow-up. METHODS: A total of 1250 VABBs were performed between January 2006 and December 2017 at our center. In total, 150 B3 cases were diagnosed and 68 of them underwent surgical excision. VABB findings were correlated with excision histology. A PPV for malignancy for each B3 subtype was derived. RESULTS: The overall PPV rate was 28%, with the highest upgrade rate for atypical ductal hyperplasia (41%), followed by classical lobular neoplasia (29%) and flat epithelial atypia (11%). Only two cases of carcinoma were detected in the follow-up cohort, both associated with atypical ductal hyperplasia at VABB. CONCLUSION: Open surgery is recommended in case of atypical ductal hyperplasia while, for other B3 lesions, excision with VABB only may be an acceptable alternative if radio-pathological correlation is assessed, if all microcalcifications have been removed by VABB, and if the lesion lacks high-risk cytological features. KEY POINTS: • Surgical treatment is strongly recommended in case of ADH, while the upgrade rate in case of pure FEA, especially following complete microcalcification removal by VABB, may be sufficiently low to advice surveillance as a management strategy. • The use of 11-G- or 8-G-needle VABB, resulting in possible complete diagnostic excision of the lesion, can be an acceptable alternative in case of RS, considering open surgery only for selected high-risk patients. • LN management is more controversial: surgical excision may be recommended following classical LN diagnosis on breast biopsy if an additional B3 lesion is concurrently detected while in the presence of isolated LN with adequate radiological-pathological correlation follow-up alone could be an acceptable option.


Asunto(s)
Neoplasias de la Mama , Carcinoma Intraductal no Infiltrante , Mama/diagnóstico por imagen , Mama/cirugía , Neoplasias de la Mama/cirugía , Humanos , Biopsia Guiada por Imagen , Mamografía , Valor Predictivo de las Pruebas , Estudios Retrospectivos
5.
Eur J Radiol ; 126: 108933, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32171109

RESUMEN

PURPOSE: To evaluate if baseline ADC from DWI sequences could predict response to treatment in patients with sacral chordoma not suitable for surgery treated with carbon ion radiotherapy (CIRT) alone compared with volume changes. METHODS: Fifty-nine patients with sacral chordoma not suitable for surgery underwent one cycle of CIRT alone and a minimum of 12-months follow-up. All patients underwent MRI before treatment (baseline), every three months in the first two years after treatment, and every six months afterwards. For each MRI, lesion volume was obtained and median, kurtosis, and skewness ADC were analyzed within the whole lesion volume. Volume changes between baseline and the last available follow-up were used to divide patients with partial response, progression of disease and stable disease (PR, PD, and SD). RESULTS: Ten patients were excluded since DWI sequences from baseline MRI were not available. ADC maps obtained from baseline DWI examinations of 50 lesions in the remaining 49 patients were considered. Seven lesions were categorized as PD, 30 PR, and 13 SD. PD showed significantly higher median ADC values at baseline (p = 0.003) compared with both PR and SD (1665vs1253vs1263 *10-6 mm²/s), and more negative skewness values (-0.26vs0.26vs0.08), although not significantly different (p = 0.16). CONCLUSIONS: Preliminary results suggest that baseline ADC could predict response to treatment with CIRT, particularly to detect potential non-responder patients.


Asunto(s)
Cordoma/diagnóstico por imagen , Cordoma/radioterapia , Imagen de Difusión por Resonancia Magnética/métodos , Radioterapia de Iones Pesados/métodos , Neoplasias de la Columna Vertebral/diagnóstico por imagen , Neoplasias de la Columna Vertebral/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Sacro/diagnóstico por imagen , Resultado del Tratamiento
6.
J Clin Ultrasound ; 45(9): 582-588, 2017 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-28734035

RESUMEN

Doppler ultrasonography is routinely used to identify abnormal blood flow. Nevertheless, conventional Doppler can be used to determine only the axial component of blood flow velocity and is angle dependent. A new method of multidimensional angle-independent estimation of flow velocity, called Vector Flow Imaging (VFI), has been proposed. It quantitatively evaluates the true velocity vector's amplitude and direction at any location into a vessel and displays a more intuitive depiction of the flow movements. High frame rate VFI, based on plane wave imaging, allows a detailed dynamic visualization of complex flow by showing even transient events, otherwise undetectable. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:582-588, 2017.


Asunto(s)
Vasos Sanguíneos/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Ultrasonografía/métodos , Velocidad del Flujo Sanguíneo/fisiología , Vasos Sanguíneos/fisiología , Humanos
7.
Insights Imaging ; 8(3): 319-328, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28500487

RESUMEN

Carotid artery atherosclerotic disease is still a significant cause of cerebrovascular morbidity and mortality. A new angle-independent technique, measuring and visualizing blood flow velocities in all directions, called vector flow imaging (VFI) is becoming available from several vendors. VFI can provide more intuitive and quantitative imaging of vortex formation, which is not clearly distinguishable in the color Doppler image. VFI, as quantitative method assessing disturbed flow patterns of the carotid bifurcation, has the potential to allow better understanding of the diagnostic value of complex flow and to enhance risk stratification. This pictorial review article will show which new information VFI adds for the knowledge of hemodynamics in comparison to the conventional ultrasound techniques. TEACHING POINTS: • VFI is an angle-independent technique measuring flow velocities in all directions. • This kind of VFI is based on a plane wave multidirectional excitation technique. • VFI allows quantitative assessment of carotid streamlines progression and visualizes vorticity. • VFI does not allow a precise comprehension of streamlines' 3D shape. • VFI allows a better understanding of carotid artery complex flows.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA