Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36032198

RESUMEN

Leakage of human cerebrospinal fluid (CSF) caused by trauma or other reasons presents exceptional challenges in clinical analysis and can have severe medical repercussions. Conventional test methods, including enzyme-linked immunosorbent assay and immunofixation electrophoresis testing, typically are performed at a few clinical reference laboratories, which may potentially delay proper diagnosis and treatment. At the same time, medical imaging can serve as a secondary diagnosis tool. This work presented here reports the use of a point-of-care electrochemical sensor for detection of beta-2-transferrin (B2T), a unique isomer of transferrin that is present exclusively in human CSF but is absent in other bodily fluids. Limits of detection were examined via serial dilution of human samples with known B2T concentrations down to 7 × 10-12 g B2T/ml while maintaining excellent sensitivity. Nine human samples with varying levels of B2T were compared using up to 100 times dilution to confirm the validity of sensor output across different patient samples.

2.
J Prosthet Dent ; 127(6): 918-924, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33483139

RESUMEN

STATEMENT OF PROBLEM: A silicon carbide (SiC) protective coating has been developed for dental ceramics, but whether the coated ceramics can match the classical VITA shades is unclear. PURPOSE: The purpose of this observational in vitro study was to evaluate the color adaptability of SiC-coated dental ceramics by testing the hypotheses that SiC-coated disks can be fabricated to match standard tooth shades and have a perceptible color match rate of at least 50% for disks with a color difference (ΔE)<2.0. The effects of ΔE, shade hue, shade value, observer sex, years of experience, profession, and shade guide orientation on color perception were studied. MATERIAL AND METHODS: SiC-coated disks were fabricated to color match (ΔEab<3.3) all 16 VITA classical shades. Uncoated disks of each VITA shade were used as the reference materials to determine whether the SiC-coated disks were color matched to the classical VITA shade guide. Three ΔE formulas (76, 94, and 2000) were applied and compared. Participants (N=120) with an average of 22 years of experience included dental school students, dental faculty members, and dental assistants. Pseudoisochromatic plate and the Farnsworth D-15 Panel test for assessing color deficiency and color blindness were administered. Participants then attempted to match SiC-coated disks to standard shade guides arranged by value or hue. All spectrophotometer readings and color matching were conducted in a light booth with standardized daylight illumination. Statistical analysis used the Fisher's exact test to determine factors associated with improved matching performance (α=.05). RESULTS: A significant difference in color match rate was found between disks with ΔE<2.0 (63.9%) and ΔE≥2.0 (41.7%) (P<.001). Arranging shade by value (72.2%) instead of hue (67.2%) produced better color matching (P<.001). Sex (P=.430), profession (P=.708), and years of experience (P=.902) had no significant influence on color matching. CONCLUSIONS: SiC-coated disks were successfully fabricated to match all VITA classical shades, and clinical visual color matching results confirmed that ΔE was a useful metric in optimizing color matching for the SiC-coated dental ceramics.


Asunto(s)
Diseño de Prótesis Dental , Coloración de Prótesis , Compuestos Inorgánicos de Carbono , Cerámica/uso terapéutico , Color , Percepción de Color , Humanos , Compuestos de Silicona
3.
J Funct Biomater ; 12(3)2021 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-34564201

RESUMEN

Peri-implantitis leads to implant failure and decreases long-term survival and success rates of implant-supported prostheses. The pathogenesis of this disease is complex but implant corrosion is believed to be one of the many factors which contributes to progression of this disease. A nanostructured titanium dioxide layer was introduced using anodization to improve the functionality of dental implants. In the present study, we evaluated the corrosion performance of silicon carbide (SiC) on anodized titanium dioxide nanotubes (ATO) using plasma-enhanced chemical vapor deposition (PECVD). This was investigated through a potentiodynamic polarization test and bacterial incubation for 30 days. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to analyze surface morphologies of non-coated and SiC-coated nanotubes. Energy dispersive X-ray (EDX) was used to analyze the surface composition. In conclusion, SiC-coated ATO exhibited improved corrosion resistance and holds promise as an implant coating material.

4.
Materials (Basel) ; 14(16)2021 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-34442878

RESUMEN

The objective of this study was to investigate the potential of titanium nanotubes to promote the proliferation of human osteoblasts and to reduce monomicrobial biofilm adhesion. A secondary objective was to determine the effect of silicon carbide (SiC) on these nanostructured surfaces. Anodized titanium sheets with 100-150 nm nanotubes were either coated or not coated with SiC. After 24 h of osteoblast cultivation on the samples, cells were observed on all titanium sheets by SEM. In addition, the cytotoxicity was evaluated by CellTiter-BlueCell assay after 1, 3, and 7 days. The samples were also cultivated in culture medium with microorganisms incubated anaerobically with respective predominant periodontal bacteria viz. Porphyromonas gingivalis, Treponema denticola, and Tannerella forsythia as monoinfection at 37 °C for 30 days. The biofilm adhesion and coverage were evaluated through surface observation using Scanning Electron Microscopy (SEM). The results demonstrate that Ti nanostructured surfaces induced more cell proliferation after seven days. All groups presented no cytotoxic effects on human osteoblasts. In addition, SEM images illustrate that Ti nanostructured surfaces exhibited lower biofilm coverage compared to the reference samples. These results indicate that Ti nanotubes promoted osteoblasts proliferation and induced cell proliferation on the surface, compared with the controls. Ti nanotubes also reduced biofilm adhesion on titanium implant surfaces.

5.
Materials (Basel) ; 14(14)2021 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-34300732

RESUMEN

Tooth decay is a prevalent disease that initiates when the oral pH becomes acidic. Fluoride and/or bioactive glass (NovaMin) were used to regenerate/repair teeth that had been decalcified. In this present study, we investigated the effect of fluoride and/or bioactive glass (NovaMin) on remineralization of hydroxyapatite (HA) discs, which mimic the enamel surface of natural teeth. HA discs were etched with phosphoric acid and treated with one of the following toothpastes: (1) Sensodyne toothpaste with fluoride; (2) Sensodyne toothpaste with fluoride and bioactive glass (NovaMin); (3) Tom's toothpaste without fluoride or bioactive glass (NovaMin); and (4) Tom's toothpaste with bioactive glass (NovaMin). The toothpastes were applied on the etched discs for two minutes, once a day for 15 days. Scanning electron microscopy (SEM) was used to analyze surface morphologies and X-ray photoelectron spectroscopy (XPS) was used to analyze surface compositions. Tom's toothpaste with only NovaMin demonstrated the most remineralization potential compared with the other groups. In conclusion, incorporating bioactive glass (NovaMin) into toothpastes could benefit the repair and remineralization of teeth.

6.
Artículo en Inglés | MEDLINE | ID: mdl-34055475

RESUMEN

Detection of the SARS-CoV-2 spike protein and inactivated virus was achieved using disposable and biofunctionalized functional strips, which can be connected externally to a reusable printed circuit board for signal amplification with an embedded metal-oxide-semiconductor field-effect transistor (MOSFET). A series of chemical reactions was performed to immobilize both a monoclonal antibody and a polyclonal antibody onto the Au-plated electrode used as the sensing surface. An important step in the biofunctionalization, namely, the formation of Au-plated clusters on the sensor strips, was verified by scanning electron microscopy, as well as electrical measurements, to confirm successful binding of thiol groups on this Au surface. The functionalized sensor was externally connected to the gate electrode of the MOSFET, and synchronous pulses were applied to both the sensing strip and the drain contact of the MOSFET. The resulting changes in the dynamics of drain waveforms were converted into analog voltages and digital readouts, which correlate with the concentration of proteins and virus present in the tested solution. A broad range of protein concentrations from 1 fg/ml to 10 µg/ml and virus concentrations from 100 to 2500 PFU/ml were detectable for the sensor functionalized with both antibodies. The results show the potential of this approach for the development of a portable, low-cost, and disposable cartridge sensor system for point-of-care detection of viral diseases.

7.
Materials (Basel) ; 14(2)2021 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-33445481

RESUMEN

The aim of this work is to investigate the effects produced by polymicrobial biofilm (Porphyromonas gingivalis, Streptococcus mutans, Streptococcus sanguinis, and Streptococcus salivarius) on the corrosion behavior of titanium dental implants. Pure titanium disks were polished and coated with titanium nitride (TiN) and silicon carbide (SiC) along with their quarternized versions. Next, the disks were cultivated in culture medium (BHI) with P. gingivalis, S. mutans, S. sanguinis, and S. salivarius and incubated anaerobically at 37 °C for 30 days. Titanium corrosion was evaluated through surface observation using Scanning Electron Microscope (SEM) and Atomic Force Microscopy (AFM). Furthermore, the Ti release in the medium was evaluated by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). SEM images showed that coated Ti disks exhibited lower corrosion compared to non-coated disks, except for the quartenized TiN. This was confirmed by AFM, where the roughness was higher in non-coated Ti disks. ICP showed that Ti levels were low in all coating disks. These results indicate that these SiC and TiN-based coatings could be a useful tool to reduce surface corrosion on titanium implant surfaces.

8.
Materials (Basel) ; 13(24)2020 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-33302431

RESUMEN

Titanium implants are commonly used in the field of dentistry for prosthetics such as crowns, bridges, and dentures. For successful therapy, an implant must bind to the surrounding bone in a process known as osseointegration. The objective for this ongoing study is to determine the potential of different implant surface coatings in providing the formation of hydroxyapatite (HA). The coatings include titanium nitride (TiN), silicon dioxide (SiO2), and quaternized titanium nitride (QTiN). The controls were a sodium hydroxide treated group, which functioned as a positive control, and an uncoated titanium group. Each coated disc was submerged in simulated body fluid (SBF), replenished every 48 h, over a period of 28 days. Each coating successfully developed a layer of HA, which was calculated through mass comparisons and observed using scanning electron microscopy (SEM) and energy dispersive analysis x-rays (EDX). Among these coatings, the quaternized titanium nitride coating seemed to have a better yield of HA. Further studies to expand the data concerning this experiment are underway.

9.
Materials (Basel) ; 13(23)2020 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-33276474

RESUMEN

Titanium (Ti) corrodes clinically in the presence of bacteria. We investigated this phenomenon as a function of Ti particles found in biopsied tissues around peri-implantitis sites and surface roughness of failed Ti implants. Tissue biopsies were surgically collected from peri-implantitis sites, processed, and embedded in resin. The resin-embedded samples were hand trimmed to the region of interest and semi-thick (500 nm) sections were collected onto coverslips. One section was toluidine blue post-stained as a reference. The remainder sections were left unstained for energy-dispersive X-ray spectroscopy (EDX) analysis. Processed samples were examined under scanning electron microscopy (SEM) and EDX. Corresponding failed implants were also removed and examined under SEM and EDX. Five out of eight biopsied samples demonstrated the presence of Ti particles in the soft tissue, suggesting the true rate among all failures was between 24.5% and 91.5% (the lower bound of a 95% confidence interval for the true rate of Ti presence). SEM analysis of failed implant bodies also indicated changes in surface morphology and appeared less detailed with decreased weight percent of Ti on the surface of the failed implants. In conclusion, Ti particles were noted in 5/8 biopsied samples. Surface morphologies were smoother in failed implants compared with the reference implant.

10.
Materials (Basel) ; 13(19)2020 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-33027910

RESUMEN

The effects of the presence of amalgam on titanium (Ti) dissolution in the oral environment under acidic, neutral, and basic conditions was studied. The presence of amalgam was found to suppress Ti release under acidic conditions due to the redeposition of TiOx/SnOx on the surface of the Ti. The redeposition of SnOx was due to the amalgam releasing its components (Hg, Cu, Sn, Ag) and the thermodynamic preference of Sn to oxidize, which was confirmed using mass measurements, ICP-MS analyses, and X-ray Photoelectron Spectroscopy (XPS). XPS depth profiling was performed to characterize the composition and oxidation states of the redeposited SnOx/TiOx film. Under basic conditions, the amalgam hindered Ti dissolution, but no redeposition of amalgam components was observed for the Ti.

11.
Materials (Basel) ; 13(15)2020 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-32722625

RESUMEN

To mitigate the corrosion of titanium implants and improve implant longevity, we investigated the capability to coat titanium implants with SiC and determined if the coating could remain intact after simulated implant placement. Titanium disks and titanium implants were coated with SiC using plasma-enhanced chemical vapor deposition (PECVD) and were examined for interface quality, chemical composition, and coating robustness. SiC-coated titanium implants were torqued into a Poly(methyl methacrylate) (PMMA) block to simulate clinical implant placement followed by energy dispersive spectroscopy to determine if the coating remained intact. After torquing, the atomic concentration of the detectable elements (silicon, carbon, oxygen, titanium, and aluminum) remained relatively unchanged, with the variation staying within the detection limits of the Energy Dispersive Spectroscopy (EDS) tool. In conclusion, plasma-enhanced chemical vapor deposited SiC was shown to conformably coat titanium implant surfaces and remain intact after torquing the coated implants into a material with a similar hardness to human bone mass.

12.
J Funct Biomater ; 11(2)2020 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-32560139

RESUMEN

Titanium nitride (TiN) and silicon carbide (SiC) adhesion properties to biofilm and the proliferation of human osteoblasts were studied. Quaternized titanium nitride (QTiN) was produced by converting the surface nitrogen on TiN to a positive charge through a quaternization process to further improve the antibacterial efficiency. The SiC required a nitridation within the plasma chamber of the surface layer before quaternization could be carried out to produce quaternized SiC (QSiC). The antimicrobial activity was evaluated on the reference strains of Porphyromonas gingivalis for 4 h by fluorescence microscopy using a live/dead viability kit. All the coatings exhibited a lower biofilm coverage compared to the uncoated samples (Ti-85.2%; TiN-24.22%; QTiN-11.4%; SiC-9.1%; QSiC-9.74%). Scanning Electron Microscope (SEM) images confirmed the reduction in P. gingivalis bacteria on the SiC and TiN-coated groups. After 24 h of osteoblast cultivation on the samples, the cell adhesion was observed on all the coated and uncoated groups. Fluorescence images demonstrated that the osteoblast cells adhered and proliferated on the surfaces. TiN and SiC coatings can inhibit the attachment of Porphyromonas gingivalis and promote osteoblast adhesion on the titanium used for implants. These coatings may possess the ability to prevent the development of peri-implantitis and stimulate osteointegration.

13.
Materials (Basel) ; 13(10)2020 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-32455653

RESUMEN

To improve the chemical durability of SiC-based coatings on glass-ceramics, the effects of annealing and N2 plasma treatment were investigated. Fluorapatite glass-ceramic disks were coated with SiC via plasma-enhanced chemical vapor deposition (PECVD), treated with N2 plasma followed by an annealing step, characterized, and then immersed in a pH 10 buffer solution for 30 days to study coating delamination. Post-deposition annealing was found to densify the deposited SiC and lessen SiC delamination during the pH 10 immersion. When the SiC was treated with a N2 plasma for 10 min, the bulk properties of the SiC coating were not affected but surface pores were sealed, slightly improving the SiC's chemical durability. By combining N2 plasma-treatment with a post-deposition annealing step, film delamination was reduced from 94% to 2.9% after immersion in a pH 10 solution for 30 days. X-ray Photoelectron spectroscopy (XPS) detected a higher concentration of oxygen on the surface of the plasma treated films, indicating a thin SiO2 layer was formed and could have assisted in pore sealing. In conclusion, post-deposition annealing and N2 plasma treatment where shown to significantly improve the chemical durability of PECVD deposited SiC films used as a coating for glass-ceramics.

14.
J Funct Biomater ; 11(2)2020 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-32443691

RESUMEN

A 200 nm plasma-enhanced chemical vapor-deposited SiC was used as a coating on dental ceramics to improve anti-bacterial properties for the applications of dental prosthesis. A thin SiO2 (20 nm) in the same system was deposited first, prior to SiC deposition, to improve the adhesion between SiC to dental ceramic. Silane and methane were the precursors for SiC deposition, and the SiO2 deposition employed silane and nitrous oxide as the precursors. SiC antimicrobial activity was evaluated on the proliferation of biofilm, Streptococcus sanguinis, and Streptococcus mutans on SiC-coated and uncoated dental ceramics for 24 h. The ceramic coating with SiC exhibited a biofilm coverage of 16.9%, whereas uncoated samples demonstrated a significantly higher biofilm coverage of 91.8%, measured with fluorescence and scanning electron microscopic images. The cytotoxicity of the SiC coating was evaluated using human periodontal ligament fibroblasts (HPdLF) by CellTiter-BlueCell viability assay. After 24 h of HPdLF cultivation, no obvious cytotoxicity was observed on the SiC coating and control group; both sets of samples exhibited similar cell adhesion and proliferation. SiC coating on a ceramic demonstrated antimicrobial activity without inducing cytotoxic effects.

15.
Materials (Basel) ; 13(5)2020 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-32182716

RESUMEN

The effect of a novel silicon carbide (SiC) coating on the chemical durability of a fluorapatite glass-ceramic veneer was investigated by examining weight loss and ion release levels. The hypothesis that this novel coating will exhibit significant corrosion resistance was tested. Inductively coupled plasma atomic emission spectrometer (ICP) was used for ion concentration determination and scanning electron microscopy (SEM) for surface morphology analyses. Samples were immersed in pH 10 and pH 2 buffer solutions to represent extreme conditions in the oral cavity. Analyses were done at 15 and 30 days. The SiC coated group demonstrated significant reduction in weight loss across all solutions and time points (p < 0.0001). Ion release analyses demonstrated either a marginally lower or a significantly lower release of ions for the SiC-coated disks. SEM analysis reveals planarization of surfaces by the SiC-coated group. The surfaces of coated samples were not as corroded as the non-coated samples, which is indicative of the protective nature of these coatings. In conclusion, SiC is a novel coating that holds promise for improving the performance of ceramic materials used for dental applications.

16.
J Am Ceram Soc ; 102(11): 6591-6599, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31819280

RESUMEN

SiO2/SiC coatings were deposited onto ceramics disks using plasma enhanced chemical vapor deposition. The effects of deposition pressure and gas-flow ratio on the refractive index, extinction coefficient, and SiC composition were studied. For the highest studied SiH4 to CH4 gas-flow ratio of 1.5, the refractive index increased by 17% from 2.53 (at the wavelength of 845 nm) to 2.96 (at the wavelength of 400 nm). For the lowest studied SiH4 to CH4 gas-flow ratio of 0.5, the refractive index only increased by 4% from 2.11 (at the wavelength of 845 nm) to 2.20 (at the wavelength of 400 nm). At higher deposition pressures, the variation in refractive index of the SiC coatings was significantly lower showing a slight increase from 1.93 (at a wavelength of 845 nm) to 1.96 at a wavelength of 400 nm. Except for the case of a low SiH4 to CH4 gas-flow ratio of 0.5, for light with wavelengths ≤ 650 nm, the extinction coefficient of the SiC coatings increased significantly. Light with a wavelength > 650 nm had an extinction coefficient near 0 in all cases. After annealing the sample at 400°C for 4 hours, hydrogen-related bonds broke and the stress of the film was reduced from -245 to -71 MPa. By utilizing different thicknesses of SiC, the full standard dental shade guide was matched with the ΔE of each coated disk being less than 3.3 compared to the shade guide.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...