Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39311975

RESUMEN

PURPOSE: To analyze anatomical and functional outcomes of cryopreserved human amniotic membrane (hAM) transplant in refractory macular hole (MH) surgery, present retinal layers structure after MH closure, identify visual acuity improvement determinants and complication rate. METHODS: Prospective and interventional case series including seventeen patients: 13 refractory and 4 chronic (8, 15, 18 and 30-years) MH. All patients underwent vitrectomy, hAM subretinal transplant, tamponade and positioning. Complete ophthalmological examination, axial length, best-corrected visual acuity, retinography, optical coherence tomography (OCT) and autofluorescence were recorded. RESULTS: Mean follow-up was 31 months (range 6-53). Mean LogMAR visual acuity (1.71 ± 0.42) improved significantly (1.13 ± 0.41) (P < 0.001). Patients with better baseline BCVA ended up with better final BCVA (P = 0.018). Mean MH minimum linear diameter was 831 ± 252 µm and base diameter was 1409 ± 358 µm. MH closed in all patients. Transitory ocular hypertension in one patient and transient vitreous cavity haemorrhage in another were the only postoperative complications. OCT matched scans showed plug integration and inner retinal layers rearrangement. MH size did not correlate with final BCVA. Autofluorescence showed no developing atrophy signs during long-term follow-up. CONCLUSION: Cryopreserved human amniotic membrane transplant may be a valuable approach to achieve macular hole closure and visual acuity improvement in refractory MH. KEY MESSAGES: What is known Human amniotic membrane transplantation is a recent surgical technique for refractory, chronic or extra-large macular holes. This surgical procedure has a shallow learning curve, high macular hole closure rate, does not require silicone oil tamponade and has very low complication rate. What is new Subretinal amniotic membrane transplant technique was successful at closing all patients' macular holes and improving visual acuity. Concerning final visual acuity predictors neither preoperative characteristics, namely the macular hole size or duration, etiology, lens status or axial length, nor surgical procedure modifications such as flap shape or tamponade lead to different outcomes. Our series included patients with refractory macular holes due to failed extended ILM peeling, failed inverted flap technique, failed autologous retinal transplant and failed epiretinal amniotic membrane transplant suggesting the technique's effectiveness in challenging refractory cases.

2.
Ophthalmic Surg Lasers Imaging Retina ; 51(3): 187-A2, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32211909

RESUMEN

BACKGROUND AND OBJECTIVE: To compare complete internal limiting membrane (ILM) peeling with the inverted flap technique for macular hole (MH) surgery. PATIENTS AND METHODS: An electronic database search on PubMed, CENTRAL, and ClinicalTrials.gov was performed. Inclusion criteria were comparative prospective/retrospective studies including patients with MH of any size with at least 6 months of follow-up. The primary outcome was MH closure rate. Secondary outcomes were best-corrected visual acuity improvement and surgery-related adverse events. RESULTS: Sixteen papers enrolling 1,403 eyes were included (733 ILM peeling, 670 inverted flap). MH mean minimum diameter and time of symptomatic evolution were higher in the inverted flap group (531.1 µm ± 188.8 µm vs. 602.8 µm ± 223.8 µm; 10.4 ± 20.2 months vs. 12.0 ± 18.4 months; P < .01). Overall, MH closure rate was superior with the inverted flap technique (risk-ratio [RR]: 1.25; 95% confidence interval [CI], 1.14-1.38; P < .0001), as well as in all subgroups: idiopathic large MH (n = 362; RR: 1.12; 95% CI, 1.05-1.20; P < .001), myopic MH without retinal detachment (n = 133; RR: 1.35; 95% CI, 1.14-1.59; P < .001), and MH retinal detachment (n = 198; RR: 1.89; 95% CI, 1.31-2.73; P < .001). CONCLUSION: This meta-analysis suggests the inverted flap technique is more effective in achieving MH closure. [Ophthalmic Surg Lasers Imaging Retina. 2020;51:187-195.].


Asunto(s)
Membrana Basal/cirugía , Retina/patología , Perforaciones de la Retina/cirugía , Agudeza Visual , Vitrectomía/métodos , Humanos , Retina/cirugía , Perforaciones de la Retina/diagnóstico , Tomografía de Coherencia Óptica
3.
Retina ; 40(7): 1299-1305, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31259810

RESUMEN

PURPOSE: To examine the influence of the inverted flap (IF) internal limiting membrane (ILM) technique in macular hole (MH) closure on outer retinal layers after MH surgery. METHODS: Retrospective study. Postoperative position of ILM, recovery rate of external limiting membrane and ellipsoid zone, and best-corrected visual acuity were evaluated. The Inserted group, where the IF is placed inside the hole, was compared with the Cover group, where the IF completely covers the hole. RESULTS: Sixty-two eyes of 58 patients who underwent vitrectomy and ILM peeling with the IF technique for large MHs (>400 µm) with successful MH closure and a follow-up of 12 months were evaluated. In the 24 eyes of the Inserted group, there was no regeneration of external limiting membrane or ellipsoid zone after 12 months. In the 38 eyes of Cover group, external limiting membrane recovered in 55.3% of patients 1 month after surgery, and in 86.1% after 12 months. The elipsoid zone layer was present in 58% of the patients. CONCLUSION: Poorer anatomical and visual results were associated with the IF technique where ILM insertion occurs compared with ILM placed over the hole. These findings suggest that insertion of the ILM in the hole might prevent outer retinal layers realignment and visual recovery in MH surgery.


Asunto(s)
Membrana Basal/cirugía , Endotaponamiento/métodos , Mácula Lútea/patología , Perforaciones de la Retina/cirugía , Colgajos Quirúrgicos , Vitrectomía/métodos , Anciano , Femenino , Estudios de Seguimiento , Humanos , Mácula Lútea/cirugía , Masculino , Perforaciones de la Retina/diagnóstico , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual
4.
J Ophthalmol ; 2019: 1345683, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31191990

RESUMEN

PURPOSE: The aim of this work was to describe the ultrastructure and behavior of peeled internal limiting membrane (ILM) in macular hole (MH) surgery. METHODS: Seven patients with MH were included, and vitrectomy with ILM peeling was performed in all patients. The ILM inverted flap technique was used. Two other flaps of ILM of the same patient were collected and studied using light and transmission electron microscopy (TEM). ILM cell type, distribution, and morphology were analyzed, and the proliferation or fusion potential of the ILM interface was evaluated. RESULTS: ILM vitreous sides in apposition showed signs of proliferative fibrotic activity, producing a basal membrane that merges ILM sides. CONCLUSIONS: Epiretinal cells in ILM show proliferative capacity, with formation of microfibrils between adjacent sides of the ILM, which may explain adherence of ILM flaps to the hole border, contributing to closure of the hole in MH surgery. This trail is registered with NCT03799575.

5.
Ophthalmol Retina ; 2(9): 913, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-31047225
6.
Ophthalmic Res ; 59(1): 24-29, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28977805

RESUMEN

PURPOSE: To highlight tomographic structural changes of retinal layers after internal limiting membrane (ILM) peeling in macular hole surgery. METHODS: Nonrandomized prospective, interventional study in 38 eyes (34 patients) subjected to pars plana vitrectomy and ILM peeling for idiopathic macular hole. Retinal layers were assessed in nasal and temporal regions before and 6 months after surgery using spectral domain optical coherence tomography. RESULTS: Total retinal thickness increased in the nasal region and decreased in the temporal region. The retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) showed thinning on both nasal and temporal sides of the fovea. The thickness of the outer plexiform layer (OPL) increased. The outer nuclear layer (ONL) and outer retinal layers (ORL) increased in thickness after surgery in both nasal and temporal regions. CONCLUSION: ILM peeling is associated with important alterations in the inner retinal layer architecture, with thinning of the RNFL-GCL-IPL complex and thickening of OPL, ONL, and ORL. These structural alterations can help explain functional outcome and could give indications regarding the extent of ILM peeling, even though peeling seems important for higher rate of hole closure.


Asunto(s)
Membrana Epirretinal/cirugía , Retina/patología , Vitrectomía/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Estudios Prospectivos , Células Ganglionares de la Retina/patología , Perforaciones de la Retina/patología , Perforaciones de la Retina/cirugía , Tomografía de Coherencia Óptica , Vitrectomía/efectos adversos
7.
Eur J Ophthalmol ; 28(3): 311-316, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29108397

RESUMEN

PURPOSE: To provide a spectral-domain optical coherence tomography (SD-OCT)-based analysis of retinal layers thickness and nasal displacement of closed macular hole after internal limiting membrane peeling in macular hole surgery. METHODS: In this nonrandomized prospective interventional study, 36 eyes of 32 patients were subjected to pars plana vitrectomy and 3.5 mm diameter internal limiting membrane (ILM) peeling for idiopathic macular hole (IMH). Nasal and temporal internal retinal layer thickness were assessed with SD-OCT. Each scan included optic disc border so that distance between optic disc border and fovea were measured. RESULTS: Thirty-six eyes had a successful surgery with macular hole closure. Total nasal retinal thickening (p<0.001) and total temporal retinal thinning (p<0.0001) were observed. Outer retinal layers increased thickness after surgery (nasal p<0.05 and temporal p<0.01). Middle part of inner retinal layers (mIRL) had nasal thickening (p<0.001) and temporal thinning (p<0.05). The mIRL was obtained by deducting ganglion cell layer (GCL) and retinal nerve fiber layer (RNFL) thickness from overall thickness of the inner retinal layer. Papillofoveal distance was shorter after ILM peeling in macular hole surgery (3,651 ± 323 µm preoperatively and 3,361 ± 279 µm at 6 months; p<0.0001). CONCLUSIONS: Internal limiting membrane peel is associated with important alteration in inner retinal layer architecture, with thickening of mIRL and shortening of papillofoveal distance. These factors may contribute to recovery of disrupted foveal photoreceptor and vision improvement after IMH closure.


Asunto(s)
Membrana Basal/cirugía , Membrana Epirretinal/cirugía , Retina/patología , Perforaciones de la Retina/cirugía , Vitrectomía , Anciano , Femenino , Fóvea Central , Humanos , Masculino , Persona de Mediana Edad , Disco Óptico , Tamaño de los Órganos , Estudios Prospectivos , Retina/diagnóstico por imagen , Perforaciones de la Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos
8.
Eur J Ophthalmol ; 27(1): 45-48, 2017 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-27338117

RESUMEN

PURPOSE: Subluxated or malpositioned intraocular lenses (IOLs) and inadequate capsular support is a challenge for every ophthalmic surgeon. Iris suture of an IOL seems to be an easy technique for the management of dislocated 3-piece IOL, allowing the IOL to be placed behind the iris, far from the trabecular meshwork and corneal endothelium. The purpose of this study is to assess the results of pars plana vitrectomy (PPV) and iris suture of dislocated 3-piece acrylic IOLs. METHODS: In this retrospective, nonrandomized, interventional case consecutive study, of a total of 103 dislocated IOLs, 36 eyes were considered for analysis. All 36 eyes had subluxated or totally luxated 3-piece IOL and underwent iris suture at the Ophthalmology Department of Santa Maria Hospital-North Lisbon Hospital Center, Portugal, from January 2011 until November 2015. All patients underwent 3-port 23-G PPV. The optic zone of the dislocated IOL was placed anterior to the iris with the haptics behind, in the posterior chamber. Haptics were sutured to iris followed by placement of the optics behind iris plane. Postoperative measures included best-corrected visual acuity (BCVA), IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and development of macular edema. RESULTS: A total of 36 eyes of 36 patients were included. All underwent successful iris fixation of dislocated 3-piece IOL. Mean overall follow-up was 15.9 months (range 3-58 months). At presentation, 16 eyes (44.4%) had a luxated IOL and 20 eyes (55.6%) a subluxated IOL. As underlying cause, 17 eyes (47.2%) had a history of complicated cataract surgery, 5 eyes (13.9%) had a traumatic dislocation of the IOL, and 6 eyes (16.7%) had a previous vitreoretinal surgery. A total of 8 eyes (22.2%) had late spontaneous IOL dislocation after uneventful cataract surgery. The mean preoperative BCVA was 1.09 ± 0.70 logarithm of the minimal angle of resolution (logMAR) units and mean postoperative BCVA was 0.48 ± 0.58 of logMAR units. The mean visual acuity improvement was 4.08 ± 5.33 lines on the logMAR scale. In this study, every IOL was stable at the last follow-up. As late complications, macular edema occurred in 1 patient and retinal detachment occurred in 2 patients. There were no cases of endophthalmitis. CONCLUSIONS: Iris suture fixation of subluxated IOL is a good treatment option for eyes with dislocated IOLs, leading to long-term stability of the IOL. The advantage of this procedure is using the same IOL in a closed eye surgery. No astigmatic difference is expected as no large corneal incision is needed.


Asunto(s)
Migracion de Implante de Lente Artificial/cirugía , Iris/cirugía , Implantación de Lentes Intraoculares , Técnicas de Sutura , Adulto , Anciano , Anciano de 80 o más Años , Migracion de Implante de Lente Artificial/etiología , Extracción de Catarata , Endotelio Corneal/cirugía , Femenino , Estudios de Seguimiento , Humanos , Lentes Intraoculares , Masculino , Persona de Mediana Edad , Polimetil Metacrilato , Portugal , Complicaciones Posoperatorias , Estudios Retrospectivos , Agudeza Visual/fisiología , Vitrectomía/métodos
9.
Int Med Case Rep J ; 9: 337-340, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27843355

RESUMEN

SUMMARY: Iris-claw intraocular lens (ICIOL) for aphakia needs a large 5.4 mm corneal incision for its implantation. The technique needs corneal suture, associated with some postoperative astigmatism. Foldable ICIOL is used in phakic patients undergoing refractive surgery and has the advantage of a sutureless small corneal incision. We report a case of a high myopic patient with dislocated intraocular lens (IOL) and no capsular support. Dislocated IOL with its capsular bag was released with three-port, 23-gauge vitrectomy; placed in the anterior chamber; sliced; and extruded through a 3.2-mm corneal incision, where a foldable ICIOL was introduced and placed retropupillary. This technique achieved a stable fixation of the IOL. Retropupillary implantation of a foldable ICIOL on aphakic patients has advantages over that of a polymethylmethacrylate (PMMA) ICIOL due to smaller corneal incision. The technique may be safe and easy to perform. PURPOSE: The purpose of this report was to describe the technique of retropupillary implantation of a foldable iris-claw intraocular lens (ICIOL) in a patient with dislocated intraocular lens (IOL) in mid vitreous cavity. METHODS: Foldable ICIOL (Artiflex® Myopia Model 401) is used in phakic patients undergoing refractive surgery and has the advantage of a sutureless small corneal incision. We report a case of a high myopic patient with dislocated IOL and no capsular support. The calculation was a -5.0 D IOL for retropupilar position, and a foldable ICIOL was introduced through a 3.2-mm corneal incision and placed retropupillary. RESULTS: The technique was easy to achieve. IOL was properly positioned retropupillary and maintained stable. There was no ocular hypertension and no anterior chamber flare or iris atrophy. CONCLUSION: Retropupillary implantation of a foldable ICIOL on aphakic patients has advantages over that of a PMMA ICIOL due to smaller corneal incision. The technique may be safe and easy to perform.

10.
Int Med Case Rep J ; 9: 261-5, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27621670

RESUMEN

BACKGROUND: Nowadays, dislocated intraocular lenses (IOLs) and inadequate capsular support are becoming a challenge for every ophthalmic surgeon. Explantation of dislocated IOL and iris claw IOL (ICIOL) are the techniques that have been used in our ophthalmic department. The aim of this study is to report our technique for retropupillar ICIOL. METHODS: This study is a retrospective case series. A total of 105 eyes with dislocated IOL from the patients at the Department of Ophthalmology in Santa Maria Hospital, a tertiary reference hospital in Lisbon, Portugal, from January 2012 until January 2016, had been analyzed. Of these 105 eyes, 66 eyes had dislocated one-piece IOL and 39 eyes had dislocated three-piece IOL. The latter underwent iris suture of the same IOL and were excluded from this study. The remaining 66 eyes with dislocated one-piece IOL underwent pars plana vitrectomy, that is, explantation of dislocated IOL through corneal incision and an implantation of retropupillary ICIOL. Operative data and postoperative outcomes included best corrected visual acuity, IOL position, intraocular pressure, pigment dispersion, clinical signs of endothelial cell loss, and anterior chamber depth. RESULTS: The mean follow-up was 23 months (range: 6-48 months). The mean preoperative best corrected visual acuity was 1.260±0.771 logMAR, and postoperative best corrected visual acuity was 0.352±0.400 logMAR units. Mean vision gain was 0.909 logMar units. The patients had the following complications: 1) retinal detachment was found in one patient, 2) corneal edema was found in three patients, 3) high intraocular pressure was observed in twelve patients, 4) subluxation of the IOL was observed in one patient, and 5) macular edema was found in three eyes. CONCLUSION: The results demonstrate that retropupillary ICIOL is an easy and effective method for the correction of aphakia in patients not receiving capsule support. The safety of this procedure must be interpreted in the context of a surgery usually indicated in complicated cases.

11.
J Curr Glaucoma Pract ; 10(2): 76-8, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27536051

RESUMEN

AIMS: To report a case of a patient who developed uveitis-glaucoma-hyphema (UGH) syndrome after an uneventful cataract surgery and to discuss risk factors, diagnostic challenges, management options, and clinical implications. BACKGROUND: Uveitis-glaucoma-hyphema syndrome is a rare but potentially serious cataract surgery complication. Clinical manifestations include increased intraocular pressure (IOP), anterior chamber inflammation, and recurrent hyphema or microhyphema. Uveitis-glaucoma-hyphema Plus syndrome also includes accompanying vitreous hemorrhage. Although classically associated with rigid anterior chamber intraocular lenses (lOLs), cases of malpositioning and subluxated posterior chamber lOLs have also been described as possible triggers. CASE DESCRIPTION: We report a case of a 70-year-old Caucasian man who developed UGH Plus syndrome after an uneventful cataract surgery with an lOL implanted in the capsular bag. During postoperative follow-up, persistent intraocular inflammation, increased IOP, hyphema, and vitreous hemorrhage were consistent with this diagnosis. Slit-lamp examination demonstrated progressive localized iris atrophy, compatible with chafing of the posterior iris by the IOL haptic as the trigger for UGH syndrome. A pars plana vitrectomy was performed and a retropupillary intraocular lens was implanted. No further complications occurred during follow-up. CONCLUSION AND CLINICAL SIGNIFICANCE: Given the increasing prevalence of single-piece lOLs implanted in the capsular bag, it is important to recognize UGH syndrome as a rare but potentially serious complication. How to cite this article: Sousa DC, Leal I, Faria MY, Pinto LA. A Rare Manifestation of Uveitis-glaucoma-hyphema Syndrome. J Curr Glaucoma Pract 2016;10(2):76-78.

12.
Int Med Case Rep J ; 9: 149-53, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27382335

RESUMEN

OBJECTIVE: To report visual outcomes, complication rate, and safety of retropupillary iris-claw intraocular lens (ICIOL) in ectopia lentis in Marfan syndrome (MFS). DESIGN: Retrospective study. METHODS: Six eyes of three MFS patients with ectopia lentis underwent surgery for subluxation lens and retropupillary ICIOL implantation from October 2014 to October 2015 at the Department of Ophthalmology, Santa Maria Hospital in Lisbon, Portugal. Demographics, preoperative and postoperative best-corrected visual acuity (BCVA), and intraocular pressure were evaluated. Endothelium cell count was assessed using specular microscopy; anterior chamber depth was measured using Pentacam postoperatively; and intraocular lens position was viewed by ultrasound biomicroscopy. All patients were female; mean age was 20±14.264 years (range: 7-38 years). RESULTS: The average follow-up period was 6.66 months (range: 4-16 months). Preoperative BCVA was 0.568±0.149 logMAR units, and postoperative BCVA was 0.066±0.121 logMAR units. The mean BCVA gain was -0.502±0.221 on the logMAR scale. Postoperative average astigmatism and intraocular pressure were 1.292±0.697 mmHg (range: 0.5-2.25 mmHg) and 16 mmHg (range: 12-18 mmHg), respectively. The average endothelial cell density decreased from 3,121±178 cells/mm(2) before surgery to 2,835±533 cells/mm(2) after surgery (measured at last follow-up visit) and in the last follow-up, representing an average endothelial cell loss of 9.16%. Mean anterior chamber depth was 4.01 mm (±0.77 mm), as measured by Pentacam. No complications were found intra- or postoperatively in any of the six studied eyes. CONCLUSION: Retropupillary ICIOL implantation is a safe and effective procedure in the treatment of aphakia in MFS eyes, without capsular support after surgery for ectopia lens. The six eyes that underwent lensectomy and retropupillary ICIOL implantation have had excellent visual outcomes with no complications so far.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...