Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Echogr ; 34(1): 19-24, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38818314

RESUMEN

Background: In heart failure patients and reduced ejection fraction (HFrEF), assessing subtle changes in left ventricle (LV) function is crucial for monitoring treatment efficacy. This study aims to determine the effect of valsartan/sacubitril on LV ejection fraction (EF) assessed by two-dimensional (2D) transthoracic echocardiography (TTE) in comparison to that assessed by 2D TTE speckle tracking in patients with HFrEF ≤35% after 6 months of treatment. Patients and Methods: A prospective study will be conducted on 200 heart failure patients with reduced EF (HFrEF) undergoing sacubitril-valsartan treatment. Each participant underwent a comprehensive evaluation, including physical examination, history taking, serial 12-lead electrocardiogram, and 2D echo to evaluate cardiac parameters. In addition, 2D speckle tracking echocardiography (STE) assessments were conducted before and after 6 months of valsartan/sacubitril treatment. Results: The enrolled patients had an average age of 48 years with 63% females. At the beginning of the study, 9 (4.5%) patients were classified as New York Heart Association (NYHA) FC I, 120 (60%) as NYHA FC II, 64 (32%) as NYHA FC III, and 7 (3.5%) as FC IV. Following treatment, 82 (41%) patients improved to NYHA FC I, and 118 (59%) were in NYHA FC II. Notably, 82 (41%) patients showed improved left ventricular EF (LVEF), detected either by traditional TTE or STE, whereas 118 (59%) showed no improvement in EF through traditional TTE. In addition, 74 (37%) patients demonstrated improvement detected by STE. In contrast, 44 (22%) patients demonstrated no improvement in EF detected by either TTE or STE. Conclusion: STE was a more reliable diagnostic method for seeing early LVEF improvement in patients with HFrEF receiving valsartan/sacubitril treatment not seen by conventional TTE.

2.
Egypt Heart J ; 75(1): 98, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38038813

RESUMEN

BACKGROUND: Left atrial global longitudinal strain (LA GLS) has been used as a new assessment tool for left atrial function. This article aims to investigate the effect of balloon mitral valvuloplasty (BMV) in patients with severe rheumatic mitral stenosis on LA GLS and its relation to the mitral valve area achieved after the procedure. The study included 95 patients with severe mitral stenosis who fulfilled the criteria for BMV (case group) and 80 normal healthy subjects (control group). All included participants underwent complete echocardiographic examinations. For the case group, LA GLS was assessed by 2D speckle-tracking Echocardiography before valvuloplasty, immediately after, within 24 h, at 6 months, and at 12 months, and the results were compared. RESULTS: The impaired left-atrium strain in patients with severe mitral stenosis was improved immediately after BMV, and the improvement continued at 6 and 12 months post-BMV (23.1% ± 4.2 vs. 36.0% ± 4.9, 36.2% ± 4.5, and 40.1% ± 9.5, respectively p < 0.01). After BMV, there was a significant decrease in left atrial volume (76.3 ± 12.4 ml/m2 vs. 68.6 ± 10.4 ml/m2, p < 0.01) and a significant increase in the area occupied by the mitral valve (1.02 ± 0.18 cm2 vs. 1.60 ± 0.31 cm, p < 0.01). The immediate LA GLS and the mitral valve area were positively correlated (r = 0.64, p < 0.01). Furthermore, the immediate LA GLS was associated with significantly improved function class (p < 0.01). CONCLUSIONS: LA GLS can indicate left atrial (mainly reservoir) function. The improvement observed in patients after BMV may indicate that LA GLS can be used to evaluate the progress after BMV. TRIAL REGISTRATION: The study was approved by the local ethics committee of the Faculty of Medicine in Minia University (Registration No. MUFMIRB 324-4-2022). Institutional Review Board, Faculty of Medicine, Minia University, Egypt. 324-4-2022, 24 18 April, 2022.

3.
Egypt Heart J ; 71(1): 19, 2019 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-31659518

RESUMEN

BACKGROUND: Results of percutaneous balloon mitral valvuloplasty (BMV) are basically dependent on suitable patient selection. Currently used two-dimensional (2D) echocardiography (2DE) scores have many limitations. Three-dimensional (3D) echocardiography (3DE)-based scores were developed for better patient selection and outcome prediction. We aimed to compare between 3D-Anwar and 2D-Wilkins scores in mitral assessment for BMV, and investigate the additive value of 3DE in prediction of immediate post-procedural outcome. Fifty patients with rheumatic mitral stenosis and candidates for BMV were included. Patients were subjected to 2D- and real-time 3D-transthoracic echocardiography (TTE) before and immediately after BMV for assessing MV area (MVA), 2D-Wilkins and 3D-Anwar score, commissural splitting, and mitral regurgitation (MR). Transesophageal echocardiography (TEE) was also undertaken immediately before and intra-procedural. Percutaneous BMV was performed by either multi-track or Inoue balloon technique. RESULTS: The 2DE underestimated post-procedural MVA than 3DE (p = 0.008). Patients with post-procedural suboptimal MVA or significant MR had higher 3D-Anwar score compared to 2D-Wilkins score (p = 0.008 and p = 0.03 respectively). The 3D-Anwar score showed a negative correlation with post-procedural MVA (r = - 0.48, p = 0.001). Receiver operating characteristic (ROC) curve analysis for both scores revealed superior prediction of suboptimal results by 3D-Anwar score (p < 0.0001). The 3DE showed better post-procedural posterior-commissural splitting than 2DE (p = 0.004). Results of both multi-track and Inoue balloon were comparable except for favorable posterior-commissural splitting by multi-track balloon (p = 0.04). CONCLUSION: The 3DE gave valuable additive data before BMV that may predict immediate post-procedural outcome and suboptimal results.

4.
Blood Press Monit ; 24(5): 221-224, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31116153

RESUMEN

INTRODUCTION: Microalbuminuria is a common early hypertension-mediated organ damage, which correlates with the overall cardiovascular risk and development of end-stage renal damage. Lately, blood pressure variability has shown an additive value over traditional BP measurement in prediction of cardiovascular and renal involvement. AIM: Investigate the relation between short-term blood pressure variability and microalbuminuria in controlled hypertensive patients. PATIENTS AND METHODS: Ninety non-diabetic hypertensive patients with controlled blood pressure and normal estimated glomerular filtration rate had 24-hour ambulatory blood pressure monitoring with calculation of short-term blood pressure variability indices (SD, coefficient of variation and average reading variability of systolic and diastolic blood pressure for 24-hour, daytime and nighttime], and measurement of the albumin/creatinine ratio. RESULTS: Patients were classified into group 1 (61 patients without microalbuminuria) and group 2 (29 patients with microalbuminuria). No significant difference was observed between both groups regarding age, sex, body mass index, office blood pressure, average 24-hour ambulatory blood pressure monitoring readings and dipping status, but significantly longer duration of hypertension in group 2. All blood pressure variability indices were significantly higher in group 2, which showed strong positive correlations with microalbuminuria level. Multivariate analysis represented an average reading variability of 24-hour systolic blood pressure as the most powerful independent predictor for microalbuminuria (r = 0.516, P = 0.001). Receiver operating characteristic curve analysis revealed that average reading variability of 24-hour systolic blood pressure (>12.55) could predict microalbuminuria (sensitivity = 89.7%, specificity = 88.5%, area under curve = 0.949, P = 0.001). CONCLUSION: Short-term blood pressure variability correlated well with early renal effects in controlled hypertensive patients. Average reading variability of 24-hour systolic blood pressure was the strongest predictor for microalbuminuria in such patients.


Asunto(s)
Albuminuria/etiología , Monitoreo Ambulatorio de la Presión Arterial , Presión Sanguínea , Hipertensión/complicaciones , Hipertensión/fisiopatología , Riñón/fisiopatología , Antihipertensivos/uso terapéutico , Presión Sanguínea/fisiología , Femenino , Tasa de Filtración Glomerular , Humanos , Hipertensión/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Análisis Multivariante , Sístole
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...