Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 267
Filtrar
1.
JOR Spine ; 7(3): e1337, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39015135

RESUMEN

Introduction: Modic changes (MC) are bone marrow lesions of vertebral bones, which can be detected with magnetic resonance imaging (MRI) adjacent to degenerated intervertebral discs. Defined by their appearance on T1 and T2 weighted images, there are three interconvertible types: MC1, MC2, and MC3. The inter-observer variability of the MRI diagnosis is high, therefore a diagnostic serum biomarker complementing the MRI to facilitate diagnosis and follow-up would be of great value. Methods: We used a highly sensitive and reproducible proteomics approach: DIA/SWATH-MS to find serum biomarkers in a subset of the Northern Finland Birth Cohort 1966. Separately, we measured a panel of factors involved in inflammation and angiogenesis to confirm some potential biomarkers published before with an ELISA-based method called V-Plex. Results: We found neither an association between the serum concentrations of the proteins detected with DIA/SWATH-MS with the presence of MC, nor a correlation with the size of the MC lesions. We did not find any association between the factors measured with the V-Plex and the presence of MC or their size. Conclusion: Altogether, our study suggests that a robust and generally usable biomarker to facilitate the diagnosis of MC cannot readily be found in serum.

2.
Eur Spine J ; 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38987513

RESUMEN

BACKGROUND: Clinical prediction models (CPM), such as the SCOAP-CERTAIN tool, can be utilized to enhance decision-making for lumbar spinal fusion surgery by providing quantitative estimates of outcomes, aiding surgeons in assessing potential benefits and risks for each individual patient. External validation is crucial in CPM to assess generalizability beyond the initial dataset. This ensures performance in diverse populations, reliability and real-world applicability of the results. Therefore, we externally validated the tool for predictability of improvement in oswestry disability index (ODI), back and leg pain (BP, LP). METHODS: Prospective and retrospective data from multicenter registry was obtained. As outcome measure minimum clinically important change was chosen for ODI with ≥ 15-point and ≥ 2-point reduction for numeric rating scales (NRS) for BP and LP 12 months after lumbar fusion for degenerative disease. We externally validate this tool by calculating discrimination and calibration metrics such as intercept, slope, Brier Score, expected/observed ratio, Hosmer-Lemeshow (HL), AUC, sensitivity and specificity. RESULTS: We included 1115 patients, average age 60.8 ± 12.5 years. For 12-month ODI, area-under-the-curve (AUC) was 0.70, the calibration intercept and slope were 1.01 and 0.84, respectively. For NRS BP, AUC was 0.72, with calibration intercept of 0.97 and slope of 0.87. For NRS LP, AUC was 0.70, with calibration intercept of 0.04 and slope of 0.72. Sensitivity ranged from 0.63 to 0.96, while specificity ranged from 0.15 to 0.68. Lack of fit was found for all three models based on HL testing. CONCLUSIONS: Utilizing data from a multinational registry, we externally validate the SCOAP-CERTAIN prediction tool. The model demonstrated fair discrimination and calibration of predicted probabilities, necessitating caution in applying it in clinical practice. We suggest that future CPMs focus on predicting longer-term prognosis for this patient population, emphasizing the significance of robust calibration and thorough reporting.

3.
Front Neurol ; 15: 1411182, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38978814

RESUMEN

Introduction: New diagnostic techniques are a substantial research focus in degenerative cervical myelopathy (DCM). This cross-sectional study determined the significance of cardiac-related spinal cord motion and the extent of spinal stenosis as indicators of mechanical strain on the cord. Methods: Eighty-four DCM patients underwent MRI/clinical assessments and were classified as MRI+ [T2-weighted (T2w) hyperintense lesion in MRI] or MRI- (no T2w-hyperintense lesion). Cord motion (displacement assessed by phase-contrast MRI) and spinal stenosis [adapted spinal canal occupation ratio (aSCOR)] were related to neurological (sensory/motor) and neurophysiological readouts [contact heat evoked potentials (CHEPs)] by receiver operating characteristic (ROC) analysis. Results: MRI+ patients (N = 31; 36.9%) were more impaired compared to MRI- patients (N = 53; 63.1%) based on the modified Japanese Orthopedic Association (mJOA) subscores for upper {MRI+ [median (Interquartile range)]: 4 (4-5); MRI-: 5 (5-5); p < 0.01} and lower extremity [MRI+: 6 (6-7); MRI-: 7 (6-7); p = 0.03] motor dysfunction and the monofilament score [MRI+: 21 (18-23); MRI-: 24 (22-24); p < 0.01]. Both patient groups showed similar extent of cord motion and stenosis. Only in the MRI- group displacement identified patients with pathologic assessments [trunk/lower extremity pin prick score (T/LEPP): AUC = 0.67, p = 0.03; CHEPs: AUC = 0.73, p = 0.01]. Cord motion thresholds: T/LEPP: 1.67 mm (sensitivity 84.6%, specificity 52.5%); CHEPs: 1.96 mm (sensitivity 83.3%, specificity 65.6%). The aSCOR failed to show any relation to the clinical assessments. Discussion: These findings affirm cord motion measurements as a promising additional biomarker to improve the clinical workup and to enable timely surgical treatment particularly in MRI- DCM patients. Clinical trial registration: www.clinicaltrials.gov, NCT02170155.

4.
Int J Spine Surg ; 18(3): 287-294, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38960609

RESUMEN

BACKGROUND: Anterior cervical discectomy and fusion (ACDF) for the surgical treatment of cervical degenerative disease often includes an intervertebral cage, which restores disc height and lordosis while promoting fusion . Cage materials include titanium (TTN) or polyetheretherketone (PEEK). Controversy in material selection stems from higher fusion rates with TNN, despite a higher subsidence rate, while PEEK cages demonstrate superior preservation of interspace height. Combining the advantages of both materials, TTN-coated PEEK (TCPEEK) cages were developed, featuring a PEEK core with similar stiffness to the bone, enveloped with a TTN coat, improving osteointegration. However, the potential superiority of TCPEEK over TTN cages has not been investigated. This study aimed to compare clinical and radiographic outcomes following single- or double-level ACDF using either TTN or TCPEEK cages. METHODS: This retrospective single-center study included patients undergoing single- or double-level ACDF between 2017 and 2019. Clinical outcomes included the Neck Disability Index and revision surgery incidence. Radiographic parameters included cervical and segmental lordosis, C2 to C7 sagittal vertical axis, fusion, subsidence, and adjacent segment degeneration at a minimum 12-month follow-up. RESULTS: A total of 45 patients (16 TTN; 29 TCPEEK) and 58 cervical levels (21 TTN; 37 TCPEEK) were included. Both cages significantly improved Neck Disability Index scores (TTN -10.0; TCPEEK -14.1) without significant differences. Two single-level TCPEEK patients required revision surgery due to non-union. In the radiological assessments, no significant difference was found for subsidence rates (TTN 52.4%; TCPEEK 56.8%), adjacent segment degeneration, cervical and segmental lordosis, and changes in C2 to C7 sagittal vertical axis. Though not statistically significant, fusion rates trended slightly higher with TTN (90.5%) vs TCPEEK cages (86.5%). CONCLUSION: TTN and TCPEEK cages achieve satisfactory clinical and radiological outcomes in single- or double-level ACDF. This finding suggests that the choice between them can be based on other factors, such as surgeon preference or availability, rather than specific material properties. CLINICAL RELEVANCE: This study found that the selection of ACDF cage material did not affect clinical outcomes.

5.
Toxicon ; : 108032, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39029562

RESUMEN

When patients present with an unknown puncture wound, emergency physicians need to consider regional hazards, in addition to standard mechanical injury etiologies. In the Southwestern United States, one such hazard is the rattlesnake. In this report, we present a case in which a rattlesnake envenomation was not considered as a possible cause for a puncture wound of unknown origin, which resulted in an envenomation left untreated for 7 days. A full dry bite observation period of twelve hours with serial physical exams and laboratory analysis with guidance from the region poison control center might have led to earlier recognition of an envenomation and antivenom administration. A male patient in his late 70's felt a painon his right ankle while in his backyard in southern Arizona. He did not see the cause and assumed he had sustained an insect bite. He went to the ED that day with minor pain and swelling and was discharged home. One week later, he re-presented severely anemic with edema and ecchymosis to the entire right lower extremity that developed over several days after his first ED visit.. He was admitted for antivenom and blood transfusion and discharged on hospital day three. For as long as humans continue to interact with the natural world, venomous creature encounters are going to continue to happen. Rattlesnake envenomation should be included in a physician's differential diagnosis even if one is not witnessed, especially in regions with high rattlesnake activity. In addition to assessing for other potential causes of undifferentiated puncture wounds, serial physical examinations and laboratory testing (with guidance of the regional poison center) are necessary to rule out rattlesnake envenomation..

6.
Trials ; 25(1): 461, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38978089

RESUMEN

BACKGROUND: The preoperative body surface and nasal decolonization may reduce the risk of surgical site infections (SSI) but yields conflicting results in the current orthopedic literature. METHODS: We perform a single-center, randomized-controlled, superiority trial in favor of the preoperative decolonization using a commercial product (octenidine® set). We will randomize a total number of 1000 adult elective orthopedic patients with a high risk for SSI and/or wound complications (age ≥ 80 years, chronic immune-suppression, American Society of Anesthesiologists score 3-4 points) between a decolonization (octenisan® wash lotion 1 × per day and octenisan® md nasal gel 2-3 × per day; during 5 days) and no decolonization. Decolonized patients will additionally fill a questionnaire regarding the practical difficulties, the completeness, and the adverse events of decolonization. The primary outcomes are SSI and revision surgeries for postoperative wound problems until 6 weeks postoperatively (or 1 year for surgeries with implants or bone). Secondary outcomes are unplanned revision surgeries for non-infectious problems and all adverse events. With 95% event-free surgeries in the decolonization arm versus 90% in the control arm, we formally need 2 × 474 elective orthopedic surgeries included during 2 years. DISCUSSION: In selected adult orthopedic patients with a high risk for SSI, the presurgical decolonization may reduce postoperative wound problems, including SSI. TRIAL REGISTRATION: ClinicalTrial.gov NCT05647252. Registered on 9 December 2022. PROTOCOL VERSION: 2 (5 December 2022).


Asunto(s)
Antiinfecciosos Locales , Procedimientos Quirúrgicos Electivos , Procedimientos Ortopédicos , Reoperación , Infección de la Herida Quirúrgica , Humanos , Infección de la Herida Quirúrgica/prevención & control , Procedimientos Ortopédicos/efectos adversos , Antiinfecciosos Locales/administración & dosificación , Antiinfecciosos Locales/efectos adversos , Piridinas/administración & dosificación , Piridinas/uso terapéutico , Piridinas/efectos adversos , Resultado del Tratamiento , Estudios de Equivalencia como Asunto , Anciano de 80 o más Años , Femenino , Masculino , Factores de Riesgo , Piel/microbiología , Cuidados Preoperatorios/métodos , Iminas
7.
Eur Spine J ; 2024 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-38825607

RESUMEN

BACKGROUND: Cervical posterior instrumentation and fusion is often performed to avoid post-laminectomy kyphosis. However, larger comparative analyses of cervical laminectomy with or without fusion are sparse. METHODS: A retrospective, two-center, comparative cohort study included patients after stand-alone dorsal laminectomy with (n = 91) or without (n = 46) additional fusion for degenerative cervical myelopathy with a median follow-up of 59 (interquartile range (IQR) 52) months. The primary outcome was the C2-7 Cobb angle and secondary outcomes were Neck Disability Index (NDI), modified Japanese Orthopaedic Association (mJOA) scale, revision rates, T1 slope and C2-7 sagittal vertical axis (C2-7 SVA) at final follow-up. Logistic regression analysis adjusted for potential confounders (i.e. age, operated levels, and follow-up). RESULTS: Preoperative C2-7 Cobb angle and T1 slope were higher in the laminectomy group, while the C2-7 SVA was similar. The decrease in C2-7 Cobb angle from pre- to postoperatively was more pronounced in the laminectomy group (- 6° (IQR 20) versus -1° (IQR 7), p = 0.002). When adjusting for confounders, the decrease in C2-7 Cobb angle remained higher in the laminectomy group (coefficient - 12 (95% confidence interval (CI) -18 to -5), p = 0.001). However, there were no adjusted differences for postoperative NDI (- 11 (- 23 to 2), p = 0.10), mJOA, revision rates, T1 slope and C2-7 SVA. CONCLUSION: Posterior cervical laminectomy without fusion is associated with mild loss of cervical lordosis of around 6° in the mid-term after approximately five years, however without any clinical relevance regarding NDI or mJOA in well-selected patients (particularly in shorter segment laminectomies of < 3 levels).

8.
Pilot Feasibility Stud ; 10(1): 70, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698433

RESUMEN

INTRODUCTION: Blinding is a methodologically important aspect in randomised controlled trials yet frequently overlooked in trials of spinal manual therapy interventions for back pain. To help inform the blinding methods of a future, double-placebo-controlled trial comparing spinal manual therapy and nerve root injection for lumbosacral radicular pain, we set four objectives: (1) to assess the feasibility of blinding participants, randomly allocated to an active or placebo-control spinal manual therapy intervention protocol, (2) to assess the feasibility of blinding outcome assessors within the trial, (3) to explore the influence of spinal manual therapy experience and low back pain on blinding, and (4) to explore factors contributing to perceptions about intervention assignment among participants and outcome assessors. METHODS AND ANALYSIS: Two-parallel-group, single-centre, placebo-controlled, methodological blinding feasibility randomised trial. We will recruit between 60 and 100 adults with or without back pain and with or without experience of spinal manual therapy from Zurich, Switzerland. Participants will be randomised to either an active spinal manual therapy or a placebo-control spinal manual therapy protocol-both interventions delivered over two study visits, up to two weeks apart. The primary outcome is participant blinding using the Bang blinding index within each intervention arm immediately after each of the two study visits. Secondary outcomes are participant blinding using the James blinding index, outcome assessor blinding (Bang and James blinding indices), self-reported factors influencing perceived intervention assignment among participants and outcome assessors, and participant-reported credibility and expectancy of study interventions. Other outcomes-included to blind the study objective from participants-are lumbar spine range of motion, self-rated general health, satisfaction with care, pain intensity, and function. Intervention provider outcomes include intervention component fidelity and quality of intervention delivery. ETHICS AND DISSEMINATION: The independent ethics commission of Canton Zurich granted ethical approval for this study (KEK 2023-00381). Written informed consent will be obtained from all participants. Findings will be disseminated in scientific conferences and a peer-reviewed publication and inform the blinding methods of a future double-placebo controlled trial comparing spinal manual therapy and nerve root injection for lumbosacral radicular pain-the SALuBRITY trial. TRIAL REGISTRATION: NCT05778396.

9.
Eur Spine J ; 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38733400

RESUMEN

PURPOSE: To analyze the effect of endplate weakness prior to PLIF or TLIF cage implantation and compare it to the opposite intact endplate of the same vertebral body. In addition, the influence of bone quality on endplate resistance was investigated. METHODS: Twenty-two human lumbar vertebrae were tested in a ramp-to-failure test. One endplate of each vertebral body was tested intact and the other after weakening with a rasp (over an area of 200 mm2). Either a TLIF or PLIF cage was then placed and the compression load was applied across the cage until failure of the endplate. Failure was defined as the first local maximum of the force measurement. Bone quality was assessed by determining the Hounsfield units (HU) on CT images. RESULTS: With an intact endplate and a TLIF cage, the median force to failure was 1276.3N (693.1-1980.6N). Endplate weakening reduced axial endplate resistance to failure by 15% (0-23%). With an intact endplate and a PLIF cage, the median force to failure was 1057.2N (701.2-1735.5N). Endplate weakening reduced axial endplate resistance to failure by 36.6% (7-47.9%). Bone quality correlated linearly with the force at which endplate failure occurred. Intact and weakened endplates showed a strong positive correlation: intact-TLIF: r = 0.964, slope of the regression line (slope) = 11.8, p < 0.001; intact-PLIF: r = 0.909, slope = 11.2, p = 5.5E-05; weakened-TLIF: r = 0.973, slope = 12.5, p < 0.001; weakened-PLIF: r = 0.836, slope = 6, p = 0.003. CONCLUSION: Weakening of the endplate during cage bed preparation significantly reduces the resistance of the endplate to subsidence to failure: endplate load capacity is reduced by 15% with TLIF and 37% with PLIF. Bone quality correlates with the force at which endplate failure occurs.

10.
Toxicon ; 244: 107775, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38782188

RESUMEN

Patients occasionally present with reports of ocular exposure to fluids from rattlesnakes, claiming or suspecting the substance to be venom. This study set out to evaluate and characterize reported cases of suspected venom-induced ophthalmia in humans. A retrospective review of rattlesnake exposures reported to the Arizona Poison and Drug Information Center over a 24-year period was conducted for ocular exposures. Recorded information included patient demographics, clinical course, laboratory results, and treatments. Documentation regarding interactions between patients and snakes was reviewed by Arizona Poison and Drug Information Center herpetologists to evaluate what substance was expelled from the snake resulting in ocular exposure. Our review of rattlesnake encounters found a total of 26 ocular exposure cases. Patient demographics were largely intentional interactions and involved the male sex. Symptoms ranged from asymptomatic to minor effects with 46.2% managed from home and treated with fluid irrigation. A review of cases by herpetologists concluded the exposure patients commonly experienced was to snake musk. Kinematics of venom expulsion by rattlesnakes conclude the venom gland must be compressed, fangs erected to ≥60o, and fang sheath compressed against the roof of the mouth for venom expulsion. Evidence suggests the chance of venom "spitting" by rattlesnakes is close to zero. Rattlesnakes are documented to forcefully expel airborne malodorous "musk" defensively. An important distinction to remember is musk has a foul odor and is usually colorless, while venom is comparatively odorless and yellow. Rattlesnake venom-induced ophthalmia is a rare event as venom expulsion requires the kinematics of feeding or defensive bites. If the rattlesnake is not in the process of biting or otherwise contacting some other object with its mouth, it is more biologically plausible patients are being exposed to snake musk as a deterrent. Whether it's venom or musk, topical exposure to the eyes should prompt immediate irrigation.


Asunto(s)
Venenos de Crotálidos , Crotalus , Mordeduras de Serpientes , Animales , Arizona , Humanos , Masculino , Estudios Retrospectivos , Femenino , Venenos de Crotálidos/toxicidad , Adulto , Persona de Mediana Edad , Adolescente , Anciano , Niño , Ojo/efectos de los fármacos , Adulto Joven , Centros de Control de Intoxicaciones
11.
JOR Spine ; 7(2): e1330, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38585427

RESUMEN

Introduction: The emerging field of the disc microbiome challenges traditional views of disc sterility, which opens new avenues for novel clinical insights. However, the lack of methodological consensus in disc microbiome studies introduces discrepancies. The aims of this study were to (1) compare the disc microbiome of non-Modic (nonMC), Modic type 1 change (MC1), and MC2 discs to findings from prior disc microbiome studies, and (2) investigate if discrepancies to prior studies can be explained with bioinformatic variations. Methods: Sequencing of 16S rRNA in 70 discs (24 nonMC, 25 MC1, and 21 MC2) for microbiome profiling. The experimental setup included buffer contamination controls and was performed under aseptic conditions. Methodology and results were contrasted with previous disc microbiome studies. Critical bioinformatic steps that were different in our best-practice approach and previous disc microbiome studies (taxonomic lineage assignment, prevalence cut-off) were varied and their effect on results were compared. Results: There was limited overlap of results with a previous study on MC disc microbiome. No bacterial genera were shared using the same bioinformatic parameters. Taxonomic lineage assignment using "amplicon sequencing variants" was more sensitive and detected 48 genera compared to 22 with "operational taxonomic units" (previous study). Increasing filter cut-off from 4% to 50% (previous study) reduced genera from 48 to 4 genera. Despite these differences, both studies observed dysbiosis with an increased abundance of gram-negative bacteria in MC discs as well as a lower beta-diversity. Cutibacterium was persistently detected in all groups independent of the bioinformatic approach, emphasizing its prevalence. Conclusion: There is dysbiosis in MC discs. Bioinformatic parameters impact results yet cannot explain the different findings from this and a previous study. Therefore, discrepancies are likely caused by different sample preparations or true biologic differences. Harmonized protocols are required to advance understanding of the disc microbiome and its clinical implications.

12.
Spine Deform ; 12(4): 989-1000, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38558382

RESUMEN

PURPOSE: Hypoplastic pedicles of the thoracolumbar spine (<5 mm diameter) are often found in syndromic deformities of the spine and pose a challenge in pedicle screw instrumentation. 3D-printed patient-specific guides might help overcome anatomical difficulties when instrumenting pedicles with screws, thereby reducing the necessity for less effective fixation methods such as hooks or sublaminar wires. In this study, the surgical feasibility and clinical outcome of patients with hypoplastic pedicles following pedicle screw instrumentation with 3D-printed patient-specific guides were assessed. METHODS: Hypoplastic pedicles were identified on preoperative computed tomography (CT) scans in six patients undergoing posterior spinal fusion surgery between 2017 and 2020. Based on these preoperative CT scans, patient-specific guides were produced to help with screw instrumentation of these thin pedicles. Postoperatively, pedicle-screw-related complications or revisions were analyzed. RESULTS: 93/105 (88.6%) pedicle screws placed with patient-specific guides were instrumented. 62/93 (66.7%) of these instrumented pedicles were defined as hypoplastic with a mean width of 3.07 mm (SD ±0.98 mm, 95% CI [2.82-3.32]). Overall, 6 complications in the 62 hypoplastic pedicles (9.7%) were observed and included intraoperatively managed 4 cerebrospinal fluid leaks, 1 pneumothorax and 1 delayed revision due to 2 lumbar screws (2/62, 3.3%) impinging the L3 nerve root causing a painful radiculopathy. The mean follow-up time was 26.7 (SD ±11.7) months. Complications were only noted when the pedicle-width-to-screw-diameter ratio measured less than 0.62. CONCLUSION: Patient-specific 3D-printed guides can aid in challenging instrumentation of hypoplastic pedicles in the thoracolumbar spine, especially if the pedicle-width-to-screw-diameter ratio is greater than 0.62.


Asunto(s)
Tornillos Pediculares , Impresión Tridimensional , Fusión Vertebral , Vértebras Torácicas , Humanos , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Masculino , Femenino , Vértebras Torácicas/cirugía , Vértebras Torácicas/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Vértebras Lumbares/cirugía , Vértebras Lumbares/diagnóstico por imagen , Adolescente , Estudios de Factibilidad , Adulto , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología
13.
Comput Methods Programs Biomed ; 247: 108096, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38447314

RESUMEN

BACKGROUND AND OBJECTIVE: As part of spinal fusion surgery, shaping the rod implant to align with the anatomy is a tedious, error-prone, and time-consuming manual process. Inadequately contoured rod implants introduce stress on the screw-bone interface of the pedicle screws, potentially leading to screw loosening or even pull-out. METHODS: We propose the first fully automated solution to the rod bending problem by leveraging the advantages of augmented reality and robotics. Augmented reality not only enables the surgeons to intraoperatively digitize the screw positions but also provides a human-computer interface to the wirelessly integrated custom-built rod bending machine. Furthermore, we introduce custom-built test rigs to quantify per screw absolute tensile/compressive residual forces on the screw-bone interface. Besides residual forces, we have evaluated the required bending times and reducer engagements, and compared our method to the freehand gold standard. RESULTS: We achieved a significant reduction of the average absolute residual forces from for the freehand gold standard to (p=0.0015) using the bending machine. Moreover, our bending machine reduced the average time to instrumentation per screw from to . Reducer engagements per rod were significantly decreased from an average of 1.00±1.14 to 0.11±0.32 (p=0.0037). CONCLUSION: The combination of augmented reality and robotics has the potential to improve surgical outcomes while minimizing the dependency on individual surgeon skill and dexterity.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Humanos , Ensayo de Materiales , Vértebras Lumbares/cirugía , Fenómenos Biomecánicos
14.
Foot Ankle Int ; 45(4): 338-347, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38390712

RESUMEN

BACKGROUND: Several demographic and clinical risk factors for recurrent ankle instability have been described. The main objective of this study was to investigate the potential influence of morphologic characteristics of the ankle joint on the occurrence of recurrent instability and the functional outcomes following a modified Broström-Gould procedure for chronic lateral ankle instability. METHODS: Fifty-eight ankles from 58 patients (28 males and 30 females) undergoing a modified Broström-Gould procedure for chronic lateral ankle instability between January 2014 and July 2021 were available for clinical and radiological evaluation. Based on the preoperative radiographs, the following radiographic parameters were measured: talar width (TW), tibial anterior surface (TAS) angle, talar height (TH), talar radius (TR), tibiotalar sector (TTS), and tibial lateral surface (TLS) angle. The history of recurrent ankle instability and the functional outcome using the Karlsson Score were assessed after a minimum follow-up of 2 years. RESULTS: Recurrent ankle instability was reported in 14 patients (24%). The TTS was significantly lower in patients with recurrent ankle instability (69.8 degrees vs 79.3 degrees) (P < .00001). The multivariate logistic regression model confirmed the TTS as an independent risk factor for recurrent ankle instability (OR = 1.64) (P = .003). The receiver operating characteristic curve analysis revealed that patients with a TTS lower than 72 degrees (=low-TTS group) had an 82-fold increased risk for recurrent ankle instability (P = .001). The low-TTS group showed a significantly higher rate of recurrent instability (58% vs 8%; P = .0001) and a significantly lower Karlsson score (65 points vs 85 points; P < .00001). CONCLUSION: A smaller TTS was found to be an independent risk factor for recurrent ankle instability and led to poorer functional outcomes after a modified Broström-Gould procedure. LEVEL OF EVIDENCE: Level IV, retrospective cohort study.

15.
Trials ; 25(1): 69, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38243311

RESUMEN

BACKGROUND: The perioperative antibiotic prophylaxis with 1st or 2nd generation cephalosporins is evidence-based in orthopedic surgery. There are, however, situations with a high risk of prophylaxis-resistant surgical site infections (SSI). METHODS: We perform a superiority randomized controlled trial with a 10% margin and a power of 90% in favor of the broad-spectrum prophylaxis. We will randomize orthopedic interventions with a high risk for SSI due to selection of resistant pathogens (open fractures, surgery under therapeutic antibiotics, orthopedic tumor surgery, spine surgery with American Society of Anesthesiologists (ASA) score ≥ 3 points) in a prospective-alternating scheme (1:1, standard prophylaxis with cefuroxime versus a broad-spectrum prophylaxis of a combined single-shot of vancomycin 1 g and gentamicin 5 mg/kg parenterally). The primary outcome is "remission" at 6 weeks for most orthopedic surgeries or at 1 year for surgeries with implant. Secondary outcomes are the risk for prophylaxis-resistant SSI pathogens, revision surgery for any reason, change of antibiotic therapy during the treatment of infection, adverse events, and the postoperative healthcare-associated infections other than SSI within 6 weeks (e.g., urine infections or pneumonia). With event-free surgeries to 95% in the broad-spectrum versus 85% in the standard prophylaxis arm, we need 2 × 207 orthopedic surgeries. DISCUSSION: In selected patients with a high risk for infections due to selection of prophylaxis-resistant SSI, a broad-spectrum combination with vancomycin and gentamycin might prevent SSIs (and other postoperative infections) better than the prophylaxis with cefuroxime. TRIAL REGISTRATION: ClinicalTrial.gov NCT05502380. Registered on 12 August 2022. Protocol version: 2 (3 June 2022).


Asunto(s)
Profilaxis Antibiótica , Neoplasias , Procedimientos Ortopédicos , Humanos , Profilaxis Antibiótica/métodos , Cefuroxima , Neoplasias/cirugía , Neoplasias/tratamiento farmacológico , Procedimientos Ortopédicos/efectos adversos , Estudios Prospectivos , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/prevención & control , Vancomicina/uso terapéutico
16.
JOR Spine ; 7(1): e1291, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38222805

RESUMEN

Background: Lumbar spine pathology (LSP) is a common source of low back or leg pain, and paraspinal muscle in these patients demonstrates fatty and fibrotic infiltration, and cellular degeneration that do not reverse with exercise-based rehabilitation. However, it is unclear of this lack of response is due to insufficient exercise stimulus, or an inability to mount a growth response. The purpose of this study was to compare paraspinal muscle gene expression between individuals with LSP who do and do not undergo an acute bout of resistance exercise. Methods: Paraspinal muscle biopsies were obtained from 64 individuals with LSP undergoing spinal surgery. Eight participants performed an acute bout of machine-based lumbar extension resistance exercise preoperatively. Gene expression for 42 genes associated with adipogenic/metabolic, atrophic, fibrogenic, inflammatory, and myogenic pathways was measured, and differential expression between exercised and non-exercised groups was evaluated for (a) the full cohort, and (b) an age, gender, acuity, and etiology matched sub-cohort. Principal components analyses were used to identify gene expression clustering across clinical phenotypes. Results: The exercised cohort demonstrated upregulation of inflammatory gene IL1B, inhibition of extracellular matrix components (increased MMP3&9, decreased TIMP1&3, COL1A1) and metabolic/adipogenic genes (FABP4, PPARD, WNT10B), and downregulation of myogenic (MYOD, ANKRD2B) and atrophic (FOXO3) genes compared to the non-exercised cohort, with similar patterns in the matched sub-analysis. There were no clinical phenotypes significantly associated with gene expression profiles. Conclusion: An acute bout of moderate-high intensity resistance exercise did not result in upregulation of myogenic genes in individuals with LSP. The response was characterized by mixed metabolic and fibrotic gene expression, upregulation of inflammation, and downregulation of myogenesis.

17.
Spine J ; 24(4): 730-735, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37871659

RESUMEN

BACKGROUD CONTEXT: Pedicle screws are commonly used for posterior fixation of the lumbar spine. Inaccuracy of screw placement can lead to disastrous complications. PURPOSE: As fluoroscopic assisted pedicle screw instrumentation is the most frequently used technique, the aim of this study was to assess the specificity, sensitivity and accuracy of intraoperative fluoroscopy to detect mediolateral screw malpositioning. We also analyzed whether the addition of an oblique view could improve these parameters. STUDY DESIGN: On 12 human cadavers, 138 pedicle screws were placed intentionally either with 0 to 2 mm (75 screws), with 2 to 4 mm (six medial and 12 lateral screws) and with >4 mm (22 medial and 23 lateral screws) breach of the pedicle from Th12 to L5. METHODS: Three experienced spine surgeons evaluated the screw positioning in fluoroscopic AP views and 4 weeks later in AP views and additional oblique views. The surgeons' interpretation was compared with the effective screw position on postoperative CT scans. RESULTS: Pedicle breaches greater than 2 mm were detected in 68% with AP views and in 67% with additional oblique views (p=.742). The specificity of AP views was 0.86 and 0.93 with additional oblique views (p=<.01). The accuracy was 0.78 with AP views and 0.81 with AP + oblique views (p=.114). There was a substantial inter-reader agreement (Fleiss's kappa: 0.632). CONCLUSIONS: Fluoroscopic screening of pedicle screw misplacement has a limited sensitivity. Adding an oblique view improves specificity but not sensitivity and accuracy in detecting screw malpositions. CLINICAL SIGNIFICANCE: When in doubt of a screw malpositioning, other modalities than a fluoroscopic assisted pedicle screw instrumentation such as intraoperative CT imaging or an intraoperative exploration of the screw trajectory must be evaluated.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Humanos , Tornillos Pediculares/efectos adversos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Tomografía Computarizada por Rayos X/métodos , Fluoroscopía/métodos , Complicaciones Posoperatorias/etiología , Fusión Vertebral/métodos
18.
Skeletal Radiol ; 53(4): 665-673, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37804455

RESUMEN

OBJECTIVE: To compare the image quality of low-dose CT (LD-CT) with tin filtration of the lumbar spine after metal implants to standard clinical CT, and to evaluate the potential for metal artifact and dose reduction. MATERIALS AND METHODS: CT protocols were optimized in a cadaver torso. Seventy-four prospectively included patients with metallic lumbar implants were scanned with both standard CT (120 kV) and tin-filtered LD-CT (Sn140kV). CT dose parameters and qualitative measures (1 = worst,4 = best) were compared. Quantitative measures included noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and the width and attenuation of the most prominent hypodense metal artifact. Standard CT and LD-CT were assessed for imaging findings. RESULTS: Tin-filtered LD-CT was performed with 60% dose saving compared to standard CT (median effective dose 3.22 mSv (quartile 1-3: 2.73-3.49 mSv) versus 8.02 mSv (6.42-9.27 mSv; p < .001). Image quality of CT and tin-filtered low-dose CT was good with excellent depiction of anatomy, while image noise was lower for CT and artifacts were weaker for tin-filtered LD-CT. Quantitative measures also revealed increased noise for tin-filtered low-dose CT (41.5HU), lower SNR (2) and CNR (0.6) compared to CT (32HU,3.55,1.03, respectively) (all p < .001). However, tin-filtered LD-CT performed superior regarding the width and attenuation of hypodense metal artifacts (2.9 mm and -767.5HU for LD-CT vs. 4.1 mm and -937HU for CT; all p < .001). No difference between methods was observed in detection of imaging findings. CONCLUSION: Tin-filtered LD-CT with 60% dose saving performs comparable to standard CT in detection of pathology and surgery related complications after lumbar spinal instrumentation, and shows superior metal artifact reduction.


Asunto(s)
Estaño , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Tomografía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
19.
Arch Orthop Trauma Surg ; 144(3): 1077-1089, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38133802

RESUMEN

INTRODUCTION: The periacetabular osteotomy is a technically demanding procedure with the goal to improve the osseous containment of the femoral head. The options for controlled execution of the osteotomies and verification of the acetabular reorientation are limited. With the assistance of augmented reality, new possibilities are emerging to guide this intervention. However, the scientific knowledge regarding AR navigation for PAO is sparse. METHODS: In this cadaveric study, we wanted to find out, if the execution of this complex procedure is feasible with AR guidance, quantify the accuracy of the execution of the three-dimensional plan, and find out what has to be done to proceed to real surgery. Therefore, an AR guidance for the PAO was developed and applied on 14 human hip cadavers. The guidance included performance of the four osteotomies and reorientation of the acetabular fragment. The osteotomy starting points, the orientation of the osteotomy planes, as well as the reorientation of the acetabular fragment were compared to the 3D planning. RESULTS: The mean 3D distance between planned and performed starting points was between 9 and 17 mm. The mean angle between planned and performed osteotomies was between 6° and 7°. The mean reorientation error between the planned and performed rotation of the acetabular fragment was between 2° and 11°. CONCLUSION: The planned correction can be achieved with promising accuracy and without serious errors. Further steps for a translation from the cadaver to the patient have been identified and must be addressed in future work.


Asunto(s)
Realidad Aumentada , Humanos , Estudios de Factibilidad , Acetábulo/cirugía , Osteotomía/métodos , Cadáver
20.
Med Image Anal ; 91: 103027, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37992494

RESUMEN

Established surgical navigation systems for pedicle screw placement have been proven to be accurate, but still reveal limitations in registration or surgical guidance. Registration of preoperative data to the intraoperative anatomy remains a time-consuming, error-prone task that includes exposure to harmful radiation. Surgical guidance through conventional displays has well-known drawbacks, as information cannot be presented in-situ and from the surgeon's perspective. Consequently, radiation-free and more automatic registration methods with subsequent surgeon-centric navigation feedback are desirable. In this work, we present a marker-less approach that automatically solves the registration problem for lumbar spinal fusion surgery in a radiation-free manner. A deep neural network was trained to segment the lumbar spine and simultaneously predict its orientation, yielding an initial pose for preoperative models, which then is refined for each vertebra individually and updated in real-time with GPU acceleration while handling surgeon occlusions. An intuitive surgical guidance is provided thanks to the integration into an augmented reality based navigation system. The registration method was verified on a public dataset with a median of 100% successful registrations, a median target registration error of 2.7 mm, a median screw trajectory error of 1.6°and a median screw entry point error of 2.3 mm. Additionally, the whole pipeline was validated in an ex-vivo surgery, yielding a 100% screw accuracy and a median target registration error of 1.0 mm. Our results meet clinical demands and emphasize the potential of RGB-D data for fully automatic registration approaches in combination with augmented reality guidance.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Cirugía Asistida por Computador , Humanos , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/cirugía , Cirugía Asistida por Computador/métodos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...