Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Ophthalmic Res ; 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38952136

RESUMEN

INTRODUCTION: To evaluate the long-term effectiveness and safety of XEN45 implant, either alone or in combination with cataract surgery, in patients with glaucoma. METHODS: Retrospective and single center study conducted on consecutive patients who underwent a XEN45 implant, either alone or in combination with cataract surgery, between November 2016 and October 2021. The primary endpoint was the mean IOP lowering from preoperative values. RESULTS: Among the 230 screened patients, 206 eyes (176 patients) were included. Fifty-three (25.7%) eyes had undergone XEN-alone and 153 (74.3%) eyes had undergone a combined procedure (XEN+Phacoemulsification). The mean preoperative intraocular pressure (IOP) was significantly higher in the XEN-alone (22.2±5.9 mmHg) than in the XEN+Phaco (19.8±4.5 mmHg) group (p=0.0035). In the overall study population, the mean preoperative IOP was significantly lowered from 20.5±5.0 mmHg to 15.8±4.4 at year-4, p<0.0001. The mean preoperative (95% CI) IOP was significantly lowered from 22.2 (20.6 to 23.8) mmHg and 19.8 (19.1 to 20.6) mmHg to 15.6 (12.2 to 16.9) mmHg and 15.9 (15.2 to 16.5) mmHg at year-4 in the XEN-alone and XEN+Phaco groups, respectively (p<0.0001 each, respectively). The number of ocular hypotensive medications was significant reduced from 2.6±1.0 drugs to 1.3±1.3 drugs, with no significant differences between XEN-alone and XEN+Phaco groups (p=0.1671). On the first postoperative day, 62 (30.1%) eyes presented some type of complication. Fifteen (7.3%) eyes underwent a needling procedure. CONCLUSION: XEN45, either alone or in combination with phacoemulsification, significantly lowered the IOP and reduce the need of ocular hypotensive medication in the long-term.

2.
Optom Vis Sci ; 98(10): 1177-1182, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34678837

RESUMEN

SIGNIFICANCE: Glaucoma patients treated with topical hypotensive eye drops often experience changes in the ocular surface, including the lid margin and the meibomian glands. In this study, the clinical parameters of the ocular surface have been analyzed to detect the presence of meibomian gland dysfunction-related dry eye disease. PURPOSE: This study aimed to evaluate the meibomian gland dysfunction in glaucoma patients secondary to topical antiglaucomatous treatment. METHODS: A total of 131 eyes from different patients with open-angle glaucoma treated with topical medication and 92 eyes from different patients with untreated ocular hypertension were consecutively and prospectively enrolled. The structure of the meibomian glands was assessed using noncontact meibography (Keratograph 5M; Oculus, Wetzlar, Germany), and their function was evaluated by measurement of meibomian glands expressibility, the duct appearance, and the Marx line location. Moreover, tear osmolarity measurement, corneal staining score (Oxford scale), and ocular symptom assessment (Ocular Surface Disease Index questionnaire) were performed. We also compared these variables in the glaucoma group according to the presence (or not) of preservative in topical treatment. RESULTS: Meibomian gland depletion was higher in glaucoma patients with topical medication (P < .001). Furthermore, the quantity of meibomian glands and expressibility of meibum in these patients were altered compared with the control group (P < .001 in both cases). In addition, the glaucoma group presented a higher degree of corneal staining as measured with the Oxford scale (P < .001). The Marx line location score was higher (P < .001 in central Marx line and P < .003 in temporal Marx line) in patients using drugs containing preservative than in those having preservative-free treatment. Logistical regression found that Marx line central, Marx line temporal, quantity of meibum expression, and quality of meibum expression have predictive ability to detect meibomian gland dysfunction-related dry eye disease. CONCLUSIONS: Glaucoma topical treatments produce meibomian gland dysfunction altering their structure and function, and this condition can be worsened using topical treatments containing preservative.


Asunto(s)
Síndromes de Ojo Seco , Enfermedades de los Párpados , Glaucoma de Ángulo Abierto , Disfunción de la Glándula de Meibomio , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/tratamiento farmacológico , Enfermedades de los Párpados/diagnóstico , Enfermedades de los Párpados/tratamiento farmacológico , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Humanos , Glándulas Tarsales/diagnóstico por imagen , Lágrimas
3.
BMC Ophthalmol ; 20(1): 35, 2020 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-31996159

RESUMEN

BACKGROUND: Bruch membrane opening-minimum rim width (BMO-MRW) assessment offers a new diagnostic use in glaucoma patients of the Glaucoma Module Premium Edition (GMPE) available for the Spectralis optical coherence tomography (OCT) system. The objective of our research was to evaluate the diagnostic benefits of examining BMO-MRW and peripapillary retinal nerve fibre layer (pRNFL) readings acquired with Spectralis OCT to distinguish between healthy and mild glaucoma patients, comparing those readings with the standard pRNFL application. Moreover, we investigated whether using a particular combination of BMO-MRW and pRNFL parameters with a linear discriminant function (LDF) could further enhance glaucoma diagnosis. METHODS: One hundred thirty-six eyes from 136 individuals were incorporated into this observational, prospective cross-sectional study: 68 mild primary open-angle glaucoma (POAG) patients according to the Hodapp-Parrish-Anderson criteria (mean deviation between 0 and - 6 dB) and 68 healthy control subjects selected by Propensity Score Matching. MRW and pRNFL thickness around the disc (diameters: 3.5 mm, 4.1 mm, and 4.7 mm) were obtained using the BMO-MRW protocol, and pRNFL thickness at 3.5 mm was obtained with the standard glaucoma application. The group data were contrasted. One sample was chosen at random to develop the LDF (teaching set: 34 healthy subjects and 34 POAG patients) using a combination of MRW and pRNFL parameters (acquired with the BMO-MRW protocol); the other sample provided a test of how the LDF performed on an independent group (validating set: 34 healthy subjects and 34 POAG patients). The receiver operating curves (ROCs) were plotted for every measurement and contrasted with the proposed LDF. The OCT parameters with the best area under the receiver operating characteristic curve (AUC) were determined. RESULTS: Global MRW and pRNFL thicknesses were significantly thinner in the POAG group (p <  0.001). The BMO-MRW parameters showed good diagnostic accuracy; the largest AUCs reached 0.875 for the LDF and 0.879 for global RNFL thickness using the standard glaucoma application. There were no statistical differences between the AUCs calculated. CONCLUSIONS: BMO-MRW parameters show a strong capability to differentiate between mild glaucoma and control eyes. Our LDF based on the new BMO-MRW OCT protocol did not perform better than isolated parameters.


Asunto(s)
Glaucoma/diagnóstico , Presión Intraocular/fisiología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Campos Visuales/fisiología , Anciano , Estudios Transversales , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC
4.
PLoS One ; 13(6): e0198397, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29879152

RESUMEN

PURPOSE: To evaluate the diagnostic ability of macular ganglion cell (mGCL) and macular retinal nerve fiber (mRNFL) layers, to detect early glaucomatous eyes, using the new segmentation software of Spectralis optical coherence tomography (OCT) device (Heidelberg Engineering). METHODS: A total of 83 eyes from 83 subjects were included in this observational, prospective cross-sectional study: 43 healthy controls and 40 early primary open-angle glaucoma (POAG) patients. All participants were examined using the Horizontal and Vertical Posterior Pole protocols, and the peripapillary RNFL (pRNFL) protocol of Spectralis OCT device. The new automated retinal segmentation software was applied to horizontal and vertical macular B-scans to determine mGCL and mRNFL thicknesses in each one of the 9 sectors of the Early Treatment Diagnostic Retinopathy Study circle. Thickness of each layer was compared between groups, and the sectors with better area under the receiver operating characteristic curve (AUC) were identified. RESULTS: mGCL was significantly thinner in the POAG group, especially in outer and inner temporal sectors (p<0.001); and mRNFL was significantly thinner in the POAG group in the outer inferior and the outer superior sector (p<0.001). Diagnostic accuracy of inner macular layers was good, and in general mGCL was superior to mRNFL. pRNFL obtained the best diagnostic capability (AUC, 0.886). Horizontal and vertical Posterior Pole protocols performed similarly. CONCLUSIONS: Inner macular layers using either horizontal or vertical B-scans, especially temporal sectors of mGCL, have good diagnostic capability to differentiate early glaucomatous eyes from control eyes; however, pRNFL has the highest diagnostic sensitivity for glaucoma detection.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico por imagen , Mácula Lútea/patología , Tomografía de Coherencia Óptica/instrumentación , Anciano , Estudios Transversales , Femenino , Glaucoma de Ángulo Abierto/patología , Humanos , Mácula Lútea/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Programas Informáticos
5.
Ophthalmic Res ; 59(1): 7-13, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28942454

RESUMEN

AIMS: To evaluate and compare peripapillary choroidal thickness (PPCT) in a wide area around the optic disk and various choroidal established zones in healthy controls and primary open-angle glaucoma (POAG) patients using a new swept-source (SS) optical coherence tomography (OCT) device. METHODS: A total of 246 eyes were finally included in this observational, prospective, cross-sectional study: 111 healthy controls and 135 POAG patients. The healthy subjects were divided into 2 populations: the teaching population (25 used to establish choroidal zones) and the validating population (86 used for comparing choroidal thickness with POAG patients). A 26 × 26 cube grid centered on the optic disk was generated using an SS-OCT to automatically measure choroidal thickness. Four choroidal zones were established and used to compare PPCT between healthy controls and POAG patients. RESULTS: PPCT was significantly thinner in zones 3 and 4 of the POAG group. The choroid exhibited a similar pattern in controls and patients with POAG; it was thickest in the superior region, followed in order by the temporal, nasal, and inferior regions. CONCLUSIONS: Peripapillary choroidal tissue shows a concentric pattern in both groups, and glaucoma patients present with peripapillary choroidal thinning compared with healthy subjects, especially in areas further away from the optic disk.


Asunto(s)
Coroides/patología , Glaucoma de Ángulo Abierto/patología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Estudios Transversales , Femenino , Humanos , Presión Intraocular , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tomografía de Coherencia Óptica/métodos , Campos Visuales
6.
Jpn J Ophthalmol ; 62(1): 41-47, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29022112

RESUMEN

PURPOSE: To evaluate automatic peripapillary choroidal thickness (PPCT) measurements in a wide area around the optic disc and various established zones in primary open-angle glaucoma (POAG) patients and age- and sex-matched healthy controls using a new swept-source optical coherence tomography (SS-OCT) device. STUDY DESIGN: Single center cross-sectional observational study. METHODS: A total of 135 POAG patients and 86 healthy subjects were consecutively enrolled. An optic disc 6.0 × 6.0 mm three-dimensional scan OD was obtained using the SS-OCT Triton. A 26 × 26 cube-grid centered in the optic disc was generated to automatically measure choroidal thickness. Seven choroidal zones were established (superior temporal, central, and nasal; inferior temporal, central, and nasal, and the optic nerve head) and compared between healthy controls and POAG patients. RESULTS: PPCT was significantly thinner in the central superior, nasal superior, and nasal inferior zones of the POAG subjects. Choroidal thickness in the central superior zone was 124.61 ± 54.95 µm in POAG group vs 156.17 ± 80.89 µm in healthy controls (p = 0.029); in the nasal superior zone, 133.84 ± 58.89 µm in the POAG group vs 168.34 ± 73.45 µm in healthy controls (p = 0.012); and in the nasal inferior zone, 113.45 ± 49.93 µm in the POAG group vs 137.47 ± 65.96 µm in healthy controls (p = 0.049). CONCLUSION: Compared with healthy subjects, glaucoma patients present with peripapillary choroidal thinning, especially in the central superior, nasal superior, and nasal inferior zones. The new SS-OCT could be a useful tool to evaluate choroidal thinning, and it could be an additional support to facilitate glaucoma diagnosis.


Asunto(s)
Coroides/patología , Glaucoma de Ángulo Abierto/diagnóstico , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Voluntarios Sanos , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Disco Óptico/patología , Tomografía de Coherencia Óptica/métodos , Tonometría Ocular , Pruebas del Campo Visual , Campos Visuales/fisiología
7.
Ophthalmic Res ; 57(4): 216-223, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28068662

RESUMEN

OBJECTIVES: To compare the circumpapillary retinal nerve fiber layer (cpRNFL) and the macular ganglion cell-inner plexiform layer (GCIPL) in glaucoma patients at different disease stages and to evaluate correlations between optical coherence tomography (OCT) parameters with central visual function and visual field (VF) indexes. PATIENTS AND METHODS: One hundred forty patients were included in this prospective cross-sectional study. Subjects diagnosed with chronic open-angle glaucoma and 20/40 or better vision were recruited and classified as having early, moderate, or severe VF defects based on Hodapp-Parrish-Anderson criteria. cpRNFL and macular GCIPL were measured using Cirrus high-definition OCT. Central retinal sensitivity and visual acuity were recorded. RESULTS: All OCT measurements differed significantly between patients with early and severe VF defects (p < 0.001). Correlations between central vision and VF indexes with OCT measurements were moderate but significant; better-correlated OCT parameters were the inferior cpRNFL quadrant, average cpRNFL thickness, inferior and inferior temporal GCIPL sectors, and minimum GCIPL thickness (r = 0.63-0.71, p < 0.001). Visual acuity was not correlated with either circumpapillary or macular OCT measurements. CONCLUSIONS: Inner macular parameters performed as well as cpRNFL in patients with different stages of glaucoma. Inferior macular GCIPL sectors, minimum GCIPL thickness, and the inferior cpRNFL quadrant best differentiate disease severity and correlate with central visual function and VF indexes.


Asunto(s)
Glaucoma/diagnóstico , Presión Intraocular/fisiología , Fibras Nerviosas/patología , Disco Óptico/diagnóstico por imagen , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Campos Visuales/fisiología , Anciano , Estudios Transversales , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Agudeza Visual , Pruebas del Campo Visual
8.
J Ophthalmol ; 2016: 7074016, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27872754

RESUMEN

Purpose. To compare contrast sensitivity, acquired color vision deficiency, and reading ability in patients with glaucoma at different stages of the disease and to establish correlations between visual field parameters and visual function scores. Methods. This prospective cross-sectional study included 121 glaucoma patients. Subjects with a diagnosis of chronic open angle glaucoma were recruited and classified according to Hodapp-Parrish-Anderson criteria. Patients with severe visual field defects were excluded because they were older, which could bias the interpretation of visual function tests. Contrast sensitivity was measured using the Pelli-Robson Chart and the CSV1000E test. Chromatic vision was evaluated using the Farnsworth-panel D15 and the L'Anthony D15 tests of Vision Color Recorder software. Reading ability was measured using Radner-Vissum test. Results. Contrast sensitivity (with photopic and mesopic luminance with glare) differed significantly between patients with early and moderate visual field defects (p < 0.05). Reading ability scores and results of the chromatic vision tests did not differ significantly between the two groups. Significant and moderate Spearman correlations between visual field indexes and contrast sensitivity tests were detected. Conclusions. Contrast sensitivity was significantly worse in patients with moderate glaucoma compared to those with early-stage glaucoma. Evaluation of visual function in clinical practice provides important information to address a glaucoma patient's vision complaints.

9.
Ophthalmic Res ; 56(2): 85-91, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27192975

RESUMEN

PURPOSE: To evaluate macular ganglion cell layer (GCL) and ganglion cell-inner plexiform layer (GCIPL) thicknesses in patients with obstructive sleep apnea (OSA) syndrome. METHODS: 73 OSA patients and 67 age-matched controls were consecutively and prospectively enrolled. All participants underwent at least one reliable standard automated perimetry (SAP) and were imaged with spectral-domain optical coherence tomography (OCT) using two different devices. The OCT parameters were compared between groups, and Pearson correlations between main indices of SAP and OCT parameters were calculated. RESULTS: The pattern standard deviation of SAP was higher in the OSA group (p = 0.001). Mean GCIPL thickness was 82.99 ± 10.30 and 80.78 ± 12.15 µm in the control and OSA groups, respectively (p = 0.25), and GCL thickness was 44.93 ± 11.42 µm in the control group and 48.81 ± 10.85 µm in OSA individuals (p = 0.47). Pearson correlations between the GCIPL-GCL measurements and the main indices of SAP were not significant. CONCLUSIONS: Neither GCIPL nor GCL thickness were reduced in OSA subjects compared with healthy individuals. Retinal sensitivity evaluated with SAP was however decreased in OSA patients.


Asunto(s)
Fibras Nerviosas/patología , Enfermedades de la Retina/etiología , Células Ganglionares de la Retina/patología , Apnea Obstructiva del Sueño/complicaciones , Tomografía de Coherencia Óptica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Enfermedades de la Retina/diagnóstico , Apnea Obstructiva del Sueño/fisiopatología
10.
BMC Ophthalmol ; 16: 40, 2016 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-27090783

RESUMEN

BACKGROUND: The effect of obstructive sleep apnea (OSA) syndrome in the peripapillary retinal nerve fiber layer (RNFL) thicknesses remains unclear. The purpose of this study was to assess RNFL measurements acquired using scanning laser polarimetry (SLP) and optical coherence tomography (OCT) in patients with OSA. METHODS: The sample of this cross-sectional study included 40 OSA patients and 45 age-matched controls, consecutively and prospectively selected. All participants underwent at least one reliable standard automated perimetry (SAP) test, while RNFL measurements were obtained using the SLP and OCT. The OSA group was divided into 3 sub-groups based on the apnea/hypopnea index (AHI): mild, moderate, or severe OSA. SAP, SLP, and OCT outcomes were compared between the control and OSA groups. The relationship between AHI and RNFL parameters was also evaluated. RESULTS: Age was not different between both groups. Mean deviation of SAP was -0.47 ± 0.9 dB and -1.43 ± 2.3 dB in the control and OSA groups, respectively (p = 0.01). RNFL thickness measured with OCT was similar between groups. OSA patients showed increased nerve fiber indicator (NFI; 20.9 ± 7.9 versus 16.42 ± 7.82; p = 0.01) and decreased superior average (59.74 ± 10.35 versus 63.73 ± 6.58; p = 0.03) obtained with SLP compared with healthy individuals. In the total sample, NFI and AHI were moderately correlated (r = 0.358; p = 0.001). In severe OSA subjects (n = 22), NFI and AHI had a Spearman correlation coefficient of 0.44 (p = 0.04). CONCLUSION: RNFL thickness measured with OCT did not differ significantly between groups. Severe OSA was related to a reduction of the RNFL thickness assessed by SLP.


Asunto(s)
Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Apnea Obstructiva del Sueño/diagnóstico , Adulto , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Polarimetría de Barrido por Laser , Tomografía de Coherencia Óptica , Pruebas del Campo Visual
11.
Ophthalmologica ; 2014 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-25427775

RESUMEN

Purpose: To assess the relationship between the retinal nerve fibre layer (RNFL) thickness and the frequency-doubling technology perimetry (FDT) outcome. Methods: Sixty-two healthy individuals and 72 glaucoma patients were prospectively selected. All participants underwent a reliable FDT and optical coherence tomography (OCT). Pearson correlations were calculated between the unlogged threshold values of FDT and RNFL thicknesses measured by OCT. Results: Mild to moderate correlations were found between a few points from FDT and RNFL thicknesses in the vertical axis. The nasal superior area of FDT and the RNFL thickness at the 7-o'clock position had the strongest correlation (0.434, p < 0.001). Conclusions: The poor agreement between FDT and OCT parameters suggests that both instruments assess different characteristics of glaucomatous optic neuropathy. The map obtained validates previously reported clinical findings and contributes to a better understanding of the structure-function relationship in glaucoma. © 2014 S. Karger AG, Basel.

12.
Invest Ophthalmol Vis Sci ; 55(11): 7119-25, 2014 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-25301881

RESUMEN

PURPOSE: To evaluate the outcomes of standard automated perimetry (SAP) in patients with obstructive sleep apnea (OSA). METHODS: Eighty OSA patients and 111 age-matched controls were consecutively and prospectively enrolled. One eye per subject was randomly selected. All participants underwent at least one reliable SAP (24-2 SITA Standard algorithm). The peripapillary retinal nerve fiber layer thickness (RNFL) was measured with spectral-domain optical coherence tomography (OCT). Patients with OSA were classified into three groups according to the apnea/hypopnea index: mild, moderate, or severe OSA. Parameters of SAP and OCT were compared between healthy controls and OSA patients. Correlation of apnea/hypopnea index with OCT and SAP measurements were calculated. RESULTS: Mean age, best-corrected visual acuity, and central corneal thickness were similar between groups. Intraocular pressure, however, was lower in the OSA group. Mean deviation of SAP was -0.23 ± 0.8 dB in the control group and -1.74 ± 2.8 dB in the OSA group (P < 0.001). Thickness of RNFL measured with OCT did not differ significantly between groups. Patients with OSA showed reduced sensitivity at most points tested by white-on-white perimetry compared with healthy individuals. The threshold values were more depressed in the peripheral visual field. The apnea/hypopnea index was related to the SAP indices: Pearson correlations were -0.432 with mean deviation, 0.467 with pattern standard deviation, and -0.416 with the visual field index (P < 0.001). CONCLUSIONS: Patients with OSA exhibited reduced retinal sensitivity measured with SAP compared with healthy controls.


Asunto(s)
Disco Óptico/fisiopatología , Enfermedades de la Retina/fisiopatología , Células Ganglionares de la Retina/fisiología , Apnea Obstructiva del Sueño/complicaciones , Campos Visuales/fisiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Disco Óptico/patología , Estudios Prospectivos , Enfermedades de la Retina/etiología , Enfermedades de la Retina/patología , Apnea Obstructiva del Sueño/patología , Apnea Obstructiva del Sueño/fisiopatología , Tomografía de Coherencia Óptica
13.
Biomed Res Int ; 2014: 514948, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25028657

RESUMEN

OBJECTIVE: To evaluate the relationship between spectral-domain optical coherence tomography (OCT) and standard automated perimetry (SAP) in healthy and glaucoma individuals. METHODS: The sample comprised 338 individuals divided into 2 groups according to intraocular pressure and visual field outcomes. All participants underwent a reliable SAP and imaging of the optic nerve head with the Cirrus OCT. Pearson correlations were calculated between threshold sensitivity values of SAP (converted to linear scale) and OCT parameters. RESULTS: Mean age did not differ between the control and glaucoma groups (59.55 ± 9.7 years and 61.05 ± 9.4 years, resp.; P = 0.15). Significant differences were found for the threshold sensitivities at each of the 52 points evaluated with SAP (P < 0.001) and the peripapillary retinal nerve fiber layer (RNFL) thicknesses, except at 3 and 9 clock-hour positions between both groups. Mild to moderate correlations (ranging between 0.286 and 0.593; P < 0.001) were observed between SAP and most OCT parameters in the glaucoma group. The strongest correlations were found between the inferior RNFL thickness and the superior hemifield points. The healthy group showed lower and weaker correlations than the glaucoma group. CONCLUSIONS: Peripapillary RNFL thickness measured with Cirrus OCT showed mild to moderate correlations with SAP in glaucoma patients.


Asunto(s)
Glaucoma/patología , Glaucoma/fisiopatología , Presión Intraocular , Fibras Nerviosas/patología , Tomografía de Coherencia Óptica/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...