Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S19-S25, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32773333

RESUMEN

OBJECTIVES: To analyze the performance of cochlear implants in French patients aged 65 and over, implanted between 2012 and 2016, using data from the French national registry for cochlear implants (EPIIC). MATERIALS AND METHODS: The French national registry incorporates patient data from before implantation and for three years after implantation, stratified in different age groups (18-39, 40-64years, 65-74years and>75years). Here, we assessed the latter two categories. Hearing was assessed using mono- and disyllabic words in a silent background. The Category of Auditory Performance (CAP) scale was also implemented and subjects took the Abbreviated Profile of Hearing Aid Benefit (Aphab) questionnaire. RESULTS: The population aged over 65 accounted for 38% (n=1193) of the 3178 adult implanted patients. The performance for mono- and disyllabic words in silence, the CAP scores and the APHAB questionnaire answers for ease of communication, background noise and reverberation were dramatically improved at one year post-implantation (P<0.0001 for each score) and remained stable between one and three years thereafter. The percentage improvement was similar across all age groups. The scores for loud-noise intolerance did not change after cochlear implantation in any age group. CONCLUSION: Cochlear implants improve hearing and communication in subjects aged 65 and over, with comparable efficiency to that achieved in younger subjects. Cochlear implantation should thus be proposed whenever hearing aids provide only limited benefit. However, between 2012 and 2016, cochlear implantation was given to less than 1% of the French population aged 65 and over with profound deafness.


Asunto(s)
Implantación Coclear/estadística & datos numéricos , Implantes Cocleares/estadística & datos numéricos , Pérdida Auditiva/rehabilitación , Sistema de Registros/estadística & datos numéricos , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Percepción Auditiva , Implantación Coclear/métodos , Comunicación , Femenino , Francia , Encuestas Epidemiológicas , Pérdida Auditiva/etiología , Pruebas Auditivas/métodos , Humanos , Masculino , Persona de Mediana Edad , Ruido/efectos adversos , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
2.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137(5): 381-386, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32037230

RESUMEN

OBJECTIVES: Telephone use correlates with quality of life, and is one of the most important expectations of cochlear implant candidates. The aim of the present study was to assess the benefit of a progressive intensive 18-session training program, conducted by telephone in cochlear implant recipients. MATERIAL AND METHODS: Nine cochlear-implanted adults underwent telerehabilitation focused on telephone use, with before-and-after assessment of: auditory performance, on Lafon monosyllabic words and MBAA sentences in quiet, cocktail-party noise and by phone; telephone use, on ad-hoc surveys and number of calls per week; and quality of life on ERSA and APHAB questionnaires. RESULTS: Before training, monosyllabic word comprehension was poorer by telephone than by direct voice (64±5.7% vs. 26±5.3%; P<0.05). After the 6-week training, there was improvement in the "note taking" telephone message task (85.0±3.7 vs. 50.0±9.0 out of 100; P<0.001), daily phone use (57.0±4.3 vs. 29±5.4 out of 100; P<0.0001), and number of calls in the week before assessment (0.0±0.0 vs. 11.0±3.0; P<0.0001). CONCLUSIONS: A progressive intensive training program by telephone improved phone use in the daily life of cochlear-implanted adults.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Lenguaje , Calidad de Vida , Teléfono
3.
AJNR Am J Neuroradiol ; 39(4): 768-774, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29472297

RESUMEN

BACKGROUND AND PURPOSE: Intraoperative conebeam CT has been introduced into the operating room and provides quick radiologic feedback. This study aimed to investigate its utility in the assessment of the positioning of the electrode array after cochlear implantation. MATERIALS AND METHODS: This was a retrospective study of 51 patients (65 ears) with intraoperative imaging by conebeam CT (O-arm) after cochlear implantation between 2013 and 2017. Correct placement into the cochlea was immediately identified. Positioning assessments were later analyzed with OsiriX software. RESULTS: Intraoperative imaging was quickly performed in all cases. No misplacement into the vestibule or semicircular canals was found. A foldover of the implanted array was identified in 1 patient. Secondary analysis by 2 raters showed excellent agreement on insertion depth angle (intraclass correlation = 0.96, P < .001) and length of insertion of the electrode array (intraclass correlation coefficient = 0.93, P = .04) measurements. The evaluation of the number of extracochlear electrodes was identical between the 2 raters in 78% of cases (Cohen κ = 0.55, P < .001). The scalar position was inconsistent between raters. When we compared O-arm and high-resolution CT images in 14 cases, the agreement was excellent for insertion depth angle (intraclass correlation coefficient = 0.97, P < .001) and insertion length (intraclass correlation coefficient = 0.98, P < .001), good for the number of extracochlear electrodes (Cohen κ = 0.63, P = .01), but moderate for the scalar position (Cohen κ = 0.59, P = .02). CONCLUSIONS: Intraoperative conebeam CT using the O-arm is a safe, rapid, easy, and reliable procedure to immediately identify a misplacement or foldover of an electrode array. The insertion depth angle, insertion length, and number of electrodes inserted can be accurately assessed.


Asunto(s)
Cóclea/diagnóstico por imagen , Implantes Cocleares , Tomografía Computarizada por Rayos X/métodos , Adulto , Cóclea/cirugía , Implantación Coclear , Femenino , Humanos , Imagenología Tridimensional , Masculino , Estudios Retrospectivos
4.
Eur Ann Otorhinolaryngol Head Neck Dis ; 135(1): 25-31, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29274768

RESUMEN

OBJECTIVES: The impact of hearing loss and of auditory rehabilitation (hearing aid, cochlear implant) on quality of life is a crucial issue. Commonly used questionnaires to assess quality of life in these patients (Nijmegen, APHAB, GBI) are time-consuming, difficult for patients to fill out, and show poor sensitivity to small improvements or deterioration. The objective of the present study was to validate a dedicated quality of life scale for hearing-impaired adults with or without auditory rehabilitation. MATERIAL AND METHODS: ERSA (Évaluation du Retentissement de la Surdité chez l'Adulte: Evaluation of the Impact of Hearing Loss in Adults) is a self-administered questionnaire. It is divided into 4 domains, each comprising 5 questions graded from 1 to 10. The questions are simple, and formulated so patients will answer according to how they feel at the actual time of the session. Test-retest reliability was measured in 38 patients. Internal coherence and validity against the APHAB questionnaire as gold standard and in relation to hearing performance were measured in 122 patients at auditory assessment. Sensitivity to change in hearing was measured in 36 cochlear implant patients, before and 6 or 12 months after implantation. RESULTS: Test-retest reliability was very satisfactory (ρ=0.88). Internal coherence was good for all questions. External validity, comparing ERSA to APHAB scores in the same non-implanted hearing-impaired patients, was good (ρ=0.52). Additionally, ERSA scores correlated with hearing performance in adverse conditions (monosyllabic words: ρ=0.22; sentences in noise: ρ=0.19). In patients tested before and after cochlear implantation, improvement in hearing performance in silence and in noise correlated with an improvement in ERSA score (ρ=0.37 to 0.59, depending on the test), but not to GBI score. CONCLUSION: The ERSA questionnaire is easy and quick to use, reliable, and sensitive to change in hearing performance after cochlear implantation.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Pérdida Auditiva/rehabilitación , Calidad de Vida , Encuestas y Cuestionarios , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Percepción del Habla , Resultado del Tratamiento
5.
Clin Otolaryngol ; 42(2): 387-396, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27608143

RESUMEN

OBJECTIVE: To analyse the anatomical, functional and quality-of-life results when using bioactive glass in mastoid and epitympanic obliteration. DESIGN: Prospective clinical study. SETTING: Tertiary referral centre. PARTICIPANTS: Forty-one cases (39 patients) operated between May 2013 and January 2015. MAIN OUTCOME MEASURES: Anatomical results were evaluated by otomicroscopy 1 year after surgery and using imaging to detect residual disease. Functional results were studied by postoperative hearing gain. Quality of life was assessed with the Glasgow Benefit Inventory questionnaire and the success of surgery by a surgery-specific questionnaire. RESULTS: At 1 year, all patients presented a well-healed external auditory canal, with an intact tympanic membrane. In cases with cholesteatoma (n = 23), no recurrent retraction pockets or residual disease were observed on imaging studies. The overall air-bone gap closure was 7.7 ± 1.84 dB (mean ± se of the mean, P < 0.001, paired t-test). No significant differences were found on hearing results when comparing primary versus revision surgery, canal-wall-up versus canal-wall-down obliterations, type of tympanoplasty and presence of cholesteatoma (multifactor anova). The Glasgow Benefit Inventory improved with an average score of 28 and the success of surgery questionnaire showed a significant improvement in ear discharge and a moderate improvement in hearing and equilibrium. CONCLUSIONS: The use of bioactive glass for mastoid and epitympanic obliteration in canal-wall-down or canal-wall-up tympanoplasties is an effective procedure in both primary and revision surgery. The anatomical and functional results appear to be well correlated with patient experience and to the improvement in quality of life.


Asunto(s)
Sustitutos de Huesos/uso terapéutico , Vidrio , Mastoidectomía , Calidad de Vida , Membrana Timpánica/cirugía , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Otoscopía , Estudios Prospectivos , Reoperación/estadística & datos numéricos , Encuestas y Cuestionarios , Resultado del Tratamiento
6.
Eur Ann Otorhinolaryngol Head Neck Dis ; 134(2): 77-82, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28034706

RESUMEN

OBJECTIVES: The aim of the study was to stimulate the vagal and the recurrent laryngeal nerves during and after thyroidectomy or parathyroidectomy, to record muscle responses, interpret the electrophysiological modifications and identify prognostic factors for postoperative vocal fold mobility. PATIENTS AND METHODS: A prospective study monitored 151 vagal nerves and 144 recurrent laryngeal nerves in 114 patients. Seven patients (14 vagal nerves) underwent continuous monitoring via an automatic periodic stimulation (APS®) electrode. In 15 patients (21 vagal nerves), the stimulation threshold was studied. Muscle response was recorded on direct vagal and/or recurrent laryngeal nerve stimulation by a monopolar electrode or direct repeated stimulation via an electrode on the vagal nerve. In case of signal attenuation on the first operated side, surgery was not extended to the contralateral side. RESULTS: The vagal nerve stimulation checked inferior laryngeal nerve integrity and recurrent status, without risk of false negatives. The vagal nerve stimulation threshold, before and after dissection, that induced a muscle response of at least 100µV ranged from 0.1 to 0.8mA. Similarity between pre- and post-dissection responses to supramaximal stimulation, defined as 1mA, on the one hand, and between post-dissection vagal and laryngeal recurrent nerve responses on the other correlated with normal postoperative vocal cord mobility. Conversely, muscle response attenuation below 100µV and increased latency indicated a risk of vocal fold palsy. CONCLUSION: Vagal nerve stimulation allows suspicion or elimination of lesions on the inferior laryngeal nerve upstream of the stimulation point and detection of non-recurrent inferior laryngeal nerve. Intermittent monitoring assesses nerve function at the moment of stimulation, while continuous monitoring detects the first signs of nerve injury liable to induce postoperative recurrent nerve palsy. When total thyroidectomy is indicated, signal attenuation on the first operated side casts doubt on continuing surgery to the contralateral side in the same step.


Asunto(s)
Monitoreo Intraoperatorio , Enfermedades de las Paratiroides/cirugía , Paratiroidectomía , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Enfermedades de la Tiroides/cirugía , Tiroidectomía , Estimulación del Nervio Vago , Adulto , Anciano , Anciano de 80 o más Años , Disección , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Paratiroidectomía/métodos , Estudios Prospectivos , Tiroidectomía/métodos , Resultado del Tratamiento , Estimulación del Nervio Vago/métodos , Parálisis de los Pliegues Vocales/prevención & control
7.
Hear Res ; 330(Pt A): 51-6, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26276418

RESUMEN

Otosclerosis is a complex disease of the human otic capsule with highest incidence in adult Caucasians. So far, many possible etiological factors like genetics, HLA, autoimmunity, viruses, inflammation, and hormones have been investigated but still the development of the disease remains unclear. Currently, the surgical replacement of stapes (stapedotomy) remains the best possible treatment option. In this review, we analyze different etiological factors studied so far in otosclerosis pathophysiology and discuss most recent findings and possible new research pathways.


Asunto(s)
Pérdida Auditiva/fisiopatología , Otosclerosis/fisiopatología , Angiotensina II/metabolismo , Animales , Autoinmunidad , Colágeno/metabolismo , Predisposición Genética a la Enfermedad , Antígenos HLA/metabolismo , Humanos , Inflamación , Virus del Sarampión , Otosclerosis/metabolismo , Estrés Oxidativo , Hormona Paratiroidea/metabolismo , Especies Reactivas de Oxígeno/metabolismo , Estribo/fisiopatología , Factor de Crecimiento Transformador beta/metabolismo
8.
Rev Med Interne ; 33(3): 143-9, 2012 Mar.
Artículo en Francés | MEDLINE | ID: mdl-22217924

RESUMEN

Cochlear implant in adults is a procedure, dedicated to rehabilitate severe to profound hearing loss. Because of technological progresses and their applications for signal strategies, new devices can improve hearing, even in noise conditions. Binaural stimulation, cochlear implant and hearing aid or bilateral cochlear implants are the best opportunities to access to better level of comprehension in all conditions and space localisation. By now minimally invasive surgery is possible to preserve residual hearing and use a double stimulation modality for the same ear: electrical for high frequencies and acoustic for low frequencies. In several conditions, cochlear implant is not possible due to cochlear nerve tumour or major malformations of the inner ear. In these cases, a brainstem implantation can be considered. Clinical data demonstrate that improvement in daily communication, for both cochlear and brainstem implants, is correlated with cerebral activation of auditory cortex.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Sordera/cirugía , Adulto , Edad de Inicio , Implantación Coclear/instrumentación , Implantes Cocleares/estadística & datos numéricos , Contraindicaciones , Sordera/diagnóstico , Sordera/epidemiología , Audífonos , Pruebas Auditivas , Humanos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia
9.
Eur Ann Otorhinolaryngol Head Neck Dis ; 129(2): 69-76, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22226672

RESUMEN

OBJECTIVES: The aim of this study was to stimulate the recurrent laryngeal nerve during thyroidectomy or parathyroidectomy and to record the muscle responses in an attempt to predict postoperative vocal fold mobility. PATIENTS AND METHODS: Intraoperative recurrent laryngeal nerve monitoring during general anaesthesia was performed by using an electrode-bearing endotracheal tube (nerve integrity monitor EMG endotracheal tube [Medtronic Xomed, Jacksonville, Flo, USA]). Two hundred and fifteen recurrent laryngeal nerves from 141 patients undergoing total thyroidectomy (n=74), hemithyroidectomy (n=63), or parathyroidectomy (n=4) were prospectively monitored. In each case, the muscle potential was recorded after stimulation of the recurrent laryngeal nerve by a monopolar probe. RESULTS: The nerve stimulation threshold before and after dissection that induced a muscle response of at least 100 µV ranged from 0.1 to 0.85 mA (mean 0.4 mA). The supramaximal stimulation intensity was defined as 1 mA. The amplitude of muscle response varied considerably from one patient to another, but the similarity of the muscle response at supramaximal intensity between pre- and postdissection and between postdissection at the proximal and distal exposed portions of the nerve was correlated with normal postoperative vocal fold function. Inversely, alteration of the muscle response indicated a considerable risk of recurrent laryngeal nerve palsy, but was not predictive of whether or not this lesion would be permanent. CONCLUSIONS: Recurrent laryngeal nerve monitoring with a system using surface electrodes is a simple, non-invasive technique that is just as sensitive as monitoring by intramuscular electrodes. Monitoring is helpful for initial nerve identification and is useful to determine nerve function during and after surgery, and to adapt the surgical strategy accordingly.


Asunto(s)
Monitoreo Intraoperatorio/métodos , Paratiroidectomía , Tiroidectomía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estimulación Eléctrica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Nervio Laríngeo Recurrente , Adulto Joven
10.
Neuropsychologia ; 48(10): 3057-61, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20600193

RESUMEN

Normal hearing listeners exploit the formant transition (FT) detection to identify place of articulation for stop consonants. Neuro-imaging studies revealed that short FT induced less cortical activation than long FT. To determine the ability of hearing impaired listeners to distinguish short and long formant transitions (FT) from vowels of the same duration, 84 mild to severe hearing impaired listeners and 5 normal hearing listeners were asked to detect 10 synthesized stimuli with long (200 ms) or short (40 ms) FT among 30 stimuli of the same duration without FT. Hearing impaired listeners were tested with and without hearing aids. The effect of the difficulty of the task (short/long FT) was analysed as a function of the hearing loss with and without hearing aids. Normal hearing listeners were able to detect every FT (short and long). For hearing impaired listeners, the detection of long FT was better than that of short ones irrespective of their degree of hearing loss. The use of hearing aids improved detection of both kinds of FT; however, the detection of long FT remained much better than the detection of the short ones. The length of FT modified the ability of hearing impaired patients to detect FT. Short FT had access to less cortical processing than long FT and cochlea damages enhanced this specific deficit in short FT brain processing. These findings help to understand the limit of deafness rehabilitation in the time domain and should be taken into account in future devices development.


Asunto(s)
Trastornos del Conocimiento/etiología , Pérdida Auditiva/complicaciones , Procesos Mentales/fisiología , Estimulación Acústica/métodos , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Femenino , Audífonos , Humanos , Masculino , Persona de Mediana Edad , Pruebas Neuropsicológicas , Psicoacústica , Tiempo de Reacción/fisiología , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...