Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Abdom Radiol (NY) ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38763936

RESUMEN

Ultrasound (US) is the imaging modality of choice for evaluation of superficial palpable lesions. A large proportion of these lesions have characteristic sonographic appearance and can be confidently diagnosed with US without the need for biopsy or other intervention. The Society of Radiologists in Ultrasound (SRU) recently published a Consensus Conference Statement on superficial soft tissue masses. The goal of this manuscript is (a) to serve as a sonographic pictorial review for palpable lesions based on the SRU statement, (b) present the typical sonographic features of palpable lesions that can be confidently diagnosed with US, and (c) provide an overview of other palpable lesions with a framework to interpret the US studies and advise on appropriate further management.

2.
Radiology ; 311(2): e232369, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38805727

RESUMEN

The American College of Radiology Liver Imaging Reporting and Data System (LI-RADS) standardizes the imaging technique, reporting lexicon, disease categorization, and management for patients with or at risk for hepatocellular carcinoma (HCC). LI-RADS encompasses HCC surveillance with US; HCC diagnosis with CT, MRI, or contrast-enhanced US (CEUS); and treatment response assessment (TRA) with CT or MRI. LI-RADS was recently expanded to include CEUS TRA after nonradiation locoregional therapy or surgical resection. This report provides an overview of LI-RADS CEUS Nonradiation TRA v2024, including a lexicon of imaging findings, techniques, and imaging criteria for posttreatment tumor viability assessment. LI-RADS CEUS Nonradiation TRA v2024 takes into consideration differences in the CEUS appearance of viable tumor and posttreatment changes within and in close proximity to a treated lesion. Due to the high sensitivity of CEUS to vascular flow, posttreatment reactive changes commonly manifest as areas of abnormal perilesional enhancement without washout, especially in the first 3 months after treatment. To improve the accuracy of CEUS for nonradiation TRA, different diagnostic criteria are used to evaluate tumor viability within and outside of the treated lesion margin. Broader criteria for intralesional enhancement increase sensitivity for tumor viability detection. Stricter criteria for perilesional enhancement limit miscategorization of posttreatment reactive changes as viable tumor. Finally, the TRA algorithm reconciles intralesional and perilesional tumor viability assessment and assigns a single LI-RADS treatment response (LR-TR) category: LR-TR nonviable, LR-TR equivocal, or LR-TR viable.


Asunto(s)
Carcinoma Hepatocelular , Medios de Contraste , Neoplasias Hepáticas , Ultrasonografía , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Ultrasonografía/métodos , Sistemas de Información Radiológica , Hígado/diagnóstico por imagen , Resultado del Tratamiento
3.
Hepatology ; 79(2): 380-391, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37548928

RESUMEN

BACKGROUND AND AIMS: The objective of this study is to determine the diagnostic accuracy of the American College of Radiology Contrast-Enhanced Ultrasound (CEUS) Liver Imaging Reporting and Data System LR-5 characterization for HCC diagnosis in North American or European patients. APPROACH AND RESULTS: A prospective multinational cohort study was performed from January 2018 through November 2022 at 11 academic and nonacademic centers in North America and Europe. Patients at risk for HCC with at least 1 liver observation not previously treated, identified on ultrasound (US), or multiphase CT or MRI performed as a part of standard clinical care were eligible for the study. All participants were examined with CEUS of the liver within 4 weeks of CT/MRI or tissue diagnosis to characterize up to 2 liver nodules per participant using ACR CEUS Liver Imaging Reporting and Data System. Definite HCC diagnosis on the initial CT/MRI, imaging follow-up, or histology for CT/MRI-indeterminate nodules were used as reference standards. A total of 545 nodules had confirmed reference standards in 480 patients, 73.8% were HCC, 5.5% were other malignancies, and 20.7% were nonmalignant. The specificity of CEUS LR-5 for HCC was 95.1% (95% CI 90.1%-97.7%), sensitivity 62.9% (95% CI 57.9%-67.7%), positive predictive value 97.3% (95% CI 94.5%-98.7%), and negative predictive value 47.7% (95% CI 41.7%-53.8%). In addition, benign CEUS characterization (LR-1 or LR-2) had 100% specificity and 100% positive predictive value for nonmalignant liver nodules. CONCLUSIONS: CEUS Liver Imaging Reporting and Data System provides an accurate categorization of liver nodules in participants at risk for HCC.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Estudios Prospectivos , Estudios de Cohortes , Medios de Contraste , Estudios Retrospectivos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Europa (Continente) , América del Norte , Sensibilidad y Especificidad
4.
Ultrasound Q ; 40(1): 1-19, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37918119

RESUMEN

ABSTRACT: Percutaneous core-needle biopsy (PCNB) plays a growing and essential role in many medical specialties. Proper and effective use of various PCNB devices requires basic understanding of how they function. Current literature lacks a detailed overview and illustration of needle function and design differences, a potentially valuable reference for users ranging from early trainees to experts who are less familiar with certain devices. This pictorial aims to provide such an overview, using diagrams and magnified photographs to illustrate the intricate components of these devices. Following a brief historical review of biopsy needle technology for context, we emphasize distinctions in design between 2 major classes of PCNB devices (side- and end-cutting devices), focusing on practical implications for how each device is most effectively used. We believe a nuanced understanding of biopsy device function sheds light on certain lingering ambiguities in biopsy practice, such as the optimal needle gauge in organ biopsy, the benefits and risks associated with coaxial technique, the impact of needle selection and technique on bleeding, and the risk of unsuccessful sampling. In a subsequent pictorial, we will draw on the concepts presented here to illustrate examples of biopsy needle failure and how unrecognized needle failure can be an important and often preventable cause of increased biopsy risk and lower tissue yield.


Asunto(s)
Biopsia Guiada por Imagen , Agujas , Nitrobencenos , Humanos , Biopsia con Aguja Gruesa , Biopsia
5.
Laryngoscope ; 134(4): 1792-1801, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37772838

RESUMEN

OBJECTIVES: The paralaryngeal muscles are thought to be hyperfunctional with phonation in patients with primary muscle tension dysphonia (pMTD). However, objective, quantitative tools to assess paralaryngeal movement patterns lack. The objectives of this study were to (1) validate the use of optical flow to characterize paralaryngeal movement patterns with phonation, (2) characterize phonatory optical flow velocities and variability of the paralaryngeal muscles before and after a vocal load challenge, and (3) compare phonatory optical flow measures to standard laryngoscopic, acoustic, and self-perceptual assessments. METHODS: Phonatory movement velocities and variability of the paralaryngeal muscles at vocal onsets and offsets were quantified from ultrasound videos and optical flow methods across 42 subjects with and without a diagnosis of pMTD, before and after a vocal load challenge. Severity of laryngoscopic mediolateral supraglottic compression, acoustic perturbation, and ratings of vocal effort and discomfort were also obtained at both time points. RESULTS: There were no significant differences in optical flow measures of the paralaryngeal muscles with phonation between patients with pMTD and controls. Patients with pMTD had significantly more supraglottic compression, higher acoustic perturbations, and higher vocal effort and vocal tract discomfort ratings. Vocal load had a significant effect on vocal effort and discomfort but not on supraglottic compression, acoustics, or optical flow measures of the paralaryngeal muscles. CONCLUSION: Optical flow methods can be used to study paralaryngeal muscle movement velocity and variability patterns during vocal productions, although the role of the paralaryngeal in pMTD diagnostics (e.g., vocal hyperfunction) remains suspect. LEVEL OF EVIDENCE: 2 Laryngoscope, 134:1792-1801, 2024.


Asunto(s)
Disfonía , Flujo Optico , Humanos , Disfonía/diagnóstico , Fonación/fisiología , Laringoscopía , Músculos
6.
Med Ultrason ; 2023 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-38150695

RESUMEN

Diagnosing rare hematological malignancies in the liver is often challenging owing to their infrequency, and confirmation generally necessitates histological examination. Due to the rarity of these lesions, there are limited data concerning their appearance on ultrasound and, specifically, contrast-enhanced ultrasound. In this review, we describe the pathological and ultrasound features of several hematological malignant liver lesions, including lymphoma of the liver and chloroma. Furthermore, two specific forms of liver lymphoma are described: mucosa-associated lymphoid tissue (MALT) lymphoma andplasmacytoma of the liver.

7.
Radiographics ; 43(8): e230032, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37498784

RESUMEN

Pelvic organ prolapse (POP) and stress urinary incontinence (SUI) are two common disorders that affect the anterior compartment of the pelvic floor in women. These can be treated conservatively or surgically. Among patients treated surgically, a substantial number present with pain, recurrent POP or SUI, or other conditions that warrant additional interventions. In many of these cases, imaging is key to identifying and characterizing the type of procedure performed, locating synthetic materials that may have been placed, and characterizing complications. Imaging may be particularly helpful when prior surgical records are not available or a comprehensive physical examination is not possible. US and MRI are the most commonly used modalities for such patients, although radiopaque surgical materials may be visible at voiding cystourethrography and CT. The authors summarize commonly used surgical treatment options for patients with SUI and POP, review imaging techniques for evaluation of such patients, and describe the normal imaging appearance and complications of pelvic floor surgical repair procedures in the anterior compartment of the pelvis. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Asunto(s)
Prolapso de Órgano Pélvico , Procedimientos de Cirugía Plástica , Incontinencia Urinaria de Esfuerzo , Humanos , Femenino , Diafragma Pélvico/diagnóstico por imagen , Diafragma Pélvico/cirugía , Prolapso de Órgano Pélvico/diagnóstico por imagen , Prolapso de Órgano Pélvico/cirugía , Incontinencia Urinaria de Esfuerzo/diagnóstico por imagen , Incontinencia Urinaria de Esfuerzo/cirugía , Incontinencia Urinaria de Esfuerzo/complicaciones , Imagen Multimodal
8.
Laryngoscope ; 133(12): 3482-3491, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37334857

RESUMEN

OBJECTIVES: It has been assumed that patients with primary muscle tension dysphonia (pMTD) have more extrinsic laryngeal muscle (ELM) tension, but tools to study this phenomenon lack. Shear wave elastography (SWE) is a potential method to address these shortcomings. The objectives of this study were to apply SWE to the ELMs, compare SWE measures to standard clinical metrics, and determine group differences in pMTD and typical voice users before and after vocal load. METHODS: SWE measurements of the ELMs from ultrasound examinations of the anterior neck, supraglottic compression severities from laryngoscopic images, cepstral peak prominences (CPP) from voice recordings, and self-perceptual ratings of vocal effort and discomfort were obtained in voice users with (N = 30) and without (N = 35) pMTD, before and after a vocal load challenge. RESULTS: ELM tension significantly increased from rest-to-voiced conditions in both groups. However, the groups were similar in their ELM stiffness levels at SWE at baseline, during vocalization, and post-vocal load. Levels of vocal effort and discomfort and supraglottic compression were significantly higher and CPP was significantly lower in the pMTD group. Vocal load had a significant effect on vocal effort and discomfort but not on laryngeal or acoustic patterns. CONCLUSION: SWE can be used to quantify ELM tension with voicing. Although the pMTD group reported significantly higher levels of vocal effort and vocal tract discomfort and, on average, exhibited significantly more severe supraglottic compression and lower CPP values, there were no group differences in levels of ELM tension using SWE. LEVEL OF EVIDENCE: 2 Laryngoscope, 133:3482-3491, 2023.


Asunto(s)
Disfonía , Diagnóstico por Imagen de Elasticidad , Voz , Humanos , Disfonía/diagnóstico por imagen , Músculos Laríngeos/diagnóstico por imagen , Tono Muscular
9.
Radiographics ; 43(7): e220178, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37289646

RESUMEN

Fatty liver disease has a high and increasing prevalence worldwide, is associated with adverse cardiovascular events and higher long-term medical costs, and may lead to liver-related morbidity and mortality. There is an urgent need for accurate, reproducible, accessible, and noninvasive techniques appropriate for detecting and quantifying liver fat in the general population and for monitoring treatment response in at-risk patients. CT may play a potential role in opportunistic screening, and MRI proton-density fat fraction provides high accuracy for liver fat quantification; however, these imaging modalities may not be suited for widespread screening and surveillance, given the high global prevalence. US, a safe and widely available modality, is well positioned as a screening and surveillance tool. Although well-established qualitative signs of liver fat perform well in moderate and severe steatosis, these signs are less reliable for grading mild steatosis and are likely unreliable for detecting subtle changes over time. New and emerging quantitative biomarkers of liver fat, such as those based on standardized measurements of attenuation, backscatter, and speed of sound, hold promise. Evolving techniques such as multiparametric modeling, radiofrequency envelope analysis, and artificial intelligence-based tools are also on the horizon. The authors discuss the societal impact of fatty liver disease, summarize the current state of liver fat quantification with CT and MRI, and describe past, currently available, and potential future US-based techniques for evaluating liver fat. For each US-based technique, they describe the concept, measurement method, advantages, and limitations. © RSNA, 2023 Online supplemental material is available for this article. Quiz questions for this article are available through the Online Learning Center.


Asunto(s)
Inteligencia Artificial , Enfermedad del Hígado Graso no Alcohólico , Humanos , Hígado/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Prevalencia
11.
J Ultrasound Med ; 42(1): 247-253, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35579375

RESUMEN

Hemoperitoneum in cirrhosis is a life-threatening condition that requires emergent evaluation. Contrast-enhanced ultrasound (CEUS) permits multiple dynamic characterizations of abdominal structures through all vascular phases, and contrast extravasation or the presence of microbubbles in the ascites could be a sensitive tool. We reviewed 13 patients with cirrhosis that underwent CEUS due to high suspicion for intra-abdominal bleeding. In 10 cases, CEUS demonstrated extravasation of contrast, including 2 instances where CEUS detected active bleeding despite negative computed tomography. These data support further study of CEUS in direct comparison to other imaging modalities in this clinical context.


Asunto(s)
Medios de Contraste , Hemoperitoneo , Humanos , Cirrosis Hepática , Ultrasonografía , Extravasación de Materiales Terapéuticos y Diagnósticos
12.
Radiographics ; 43(2): e220093, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36563094

RESUMEN

Contrast-enhanced US (CEUS), similar to other radiologic modalities, requires specific technical considerations and is subject to image artifacts. These artifacts may affect examination quality, negatively impact diagnostic accuracy, and decrease user comfort when using this emerging technique. Some artifacts are related to commonly known gray-scale US artifacts that can also appear on the contrast-only image (tissue-subtracted image obtained with the linear responses from background tissues nulled). These may include acoustic shadowing and enhancement; reverberation, refraction, and reflection; and poor penetration. Other artifacts are exclusive to CEUS owing to the techniques used for contrast mode image generation and the unique properties of the microbubbles that constitute ultrasound-specific contrast agents (UCAs). UCA-related artifacts may appear on the contrast-only image, the gray-scale image, or various Doppler mode images. Artifacts related to CEUS may include nonlinear artifacts and unintentional microbubble destruction resulting in pseudowashout. The microbubbles themselves may result in specific artifacts such as pseudoenhancement, signal saturation, and attenuation and shadowing and can confound the use of color and spectral Doppler US. Identifying and understanding these artifacts and knowing how to mitigate them may improve the quality of the imaging study, increase user confidence, and improve patient care. The authors review the principles of UCAs and the sound-microbubble interaction, as well as the technical aspects of image generation. Technical considerations, including patient positioning, depth, acoustic window, and contrast agent dose, also are discussed. Specific artifacts are described, with tips on how to identify and, if necessary, apply corrective measures, with the goal of improving examination quality. © RSNA, 2022 Online supplemental material and the slide presentation from the RSNA Annual Meeting are available for this article.


Asunto(s)
Artefactos , Medios de Contraste , Humanos , Ultrasonografía/métodos , Microburbujas
14.
Radiographics ; 43(1): e220066, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36427260

RESUMEN

The use of standardized terms in assessing and reporting disease processes has well-established benefits, such as clear communication between radiologists and other health care providers, improved diagnostic accuracy and reproducibility, and the enhancement and facilitation of research. Recently, the Liver Imaging Reporting and Data System (LI-RADS) Steering Committee released a universal liver imaging lexicon. The current version of the lexicon includes 81 vetted and precisely defined terms that are relevant to acquisition of images using all major liver imaging modalities and contrast agents, as well as lesion- and organ-level features. Most terms in the lexicon are applicable to all patients undergoing imaging of the liver, and only a minority of the terms are strictly intended to be used for patients with high risk factors for hepatocellular carcinoma. This pictorial atlas familiarizes readers with the liver imaging lexicon and includes discussion of general concepts, providing sample definitions, schematics, and clinical examples for a subset of the terms in the liver imaging lexicon. The authors discuss general, technical, and imaging feature terms used commonly in liver imaging, with the goal of illustrating their use for clinical and research applications. Work of the U.S. Government published under an exclusive license with the RSNA. Online supplemental material is available for this article.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Reproducibilidad de los Resultados , Neoplasias Hepáticas/diagnóstico por imagen , Diagnóstico por Imagen
16.
Radiographics ; 42(6): 1724-1741, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36190849

RESUMEN

With the increasing availability of contrast-enhanced US (CEUS) worldwide and in the United States, the potential applications of this modality in abdominal imaging and intervention are continuing to expand. CEUS leverages the many inherent benefits of US with a safe and unique microbubble contrast agent. When injected intravenously, US contrast agents (UCAs) function as a pure blood pool agent, augmenting diagnostic US examinations such as vascular imaging. In the procedure suite, UCA can be used to improve needle visualization and depict active extravasation. UCA may also be injected through needles and tubes into various body spaces, allowing the assessment of the urinary system, indwelling catheters, and other tracts and cavities. Some venous and lymphatic lesions may be diagnosed with the direct injection of a UCA into these lesions. The authors highlight some of the many applications that are relevant to the abdominal imaging professional and interventional radiologist but should not be considered a complete list, and users of UCAs should continue to consider uses beyond those traditionally highlighted in recent literature. Online supplemental material is available for this article. ©RSNA, 2022.


Asunto(s)
Medios de Contraste , Microburbujas , Abdomen/diagnóstico por imagen , Diagnóstico por Imagen , Humanos , Ultrasonografía/métodos
17.
Surg Oncol Clin N Am ; 31(4): 707-719, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36243503

RESUMEN

Contrast-enhanced intraoperative ultrasound (CE-IOUS) is a relatively new but valuable tool that is increasingly used as an adjunct to computed tomography, MRI, and IOUS for patients undergoing liver surgery. CE-IOUS has an important role in 2 main settings: the discrimination of indeterminate lesions detected in cirrhotic livers by conventional IOUS and in the detection of colorectal liver metastasis that may be overlooked by other imaging modalities. The intraoperative nature of the imaging and interpretation allows for CE-IOUS to directly affect surgical decision-making that may importantly affect patient outcomes.


Asunto(s)
Neoplasias Colorrectales , Neoplasias Hepáticas , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/cirugía , Medios de Contraste , Hepatectomía , Humanos , Cuidados Intraoperatorios/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética/métodos , Ultrasonografía
18.
Radiology ; 305(2): 265-276, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36098640

RESUMEN

Excessive liver fat (steatosis) is now the most common cause of chronic liver disease worldwide and is an independent risk factor for cirrhosis and associated complications. Accurate and clinically useful diagnosis, risk stratification, prognostication, and therapy monitoring require accurate and reliable biomarker measurement at acceptable cost. This article describes a joint effort by the American Institute of Ultrasound in Medicine (AIUM) and the RSNA Quantitative Imaging Biomarkers Alliance (QIBA) to develop standards for clinical and technical validation of quantitative biomarkers for liver steatosis. The AIUM Liver Fat Quantification Task Force provides clinical guidance, while the RSNA QIBA Pulse-Echo Quantitative Ultrasound Biomarker Committee develops methods to measure biomarkers and reduce biomarker variability. In this article, the authors present the clinical need for quantitative imaging biomarkers of liver steatosis, review the current state of various imaging modalities, and describe the technical state of the art for three key liver steatosis pulse-echo quantitative US biomarkers: attenuation coefficient, backscatter coefficient, and speed of sound. Lastly, a perspective on current challenges and recommendations for clinical translation for each biomarker is offered.


Asunto(s)
Hígado Graso , Enfermedad del Hígado Graso no Alcohólico , Humanos , Hígado Graso/diagnóstico por imagen , Hígado/diagnóstico por imagen , Ultrasonografía/métodos , Biomarcadores , Estándares de Referencia , Imagen por Resonancia Magnética
19.
Radiol Clin North Am ; 60(5): 717-730, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35989040

RESUMEN

Contrast-enhanced ultrasound (CEUS) is increasingly performed for focal liver lesion evaluation because of its high safety profile and ability to yield a definitive diagnosis in many patients, obviating multiphase CT or MRI. CEUS uses specific ultrasound contrast agents (UCAs) that are exceedingly safe, without the risk of renal or liver toxicity. UCAs are cleared rapidly from the body, allowing for multiple injections during a single examination, with no potential for deposition in the patient. This review highlights the performance of CEUS for liver lesion evaluation and illustrates the imaging appearance of common liver lesions in children and adults.


Asunto(s)
Neoplasias Hepáticas , Abdomen/patología , Adulto , Niño , Medios de Contraste , Humanos , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/patología , Ultrasonografía/métodos
20.
Radiology ; 305(2): 277-289, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35787200

RESUMEN

Gallbladder polyps (also known as polypoid lesions of the gallbladder) are a common incidental finding. The vast majority of gallbladder polyps smaller than 10 mm are not true neoplastic polyps but are benign cholesterol polyps with no inherent risk of malignancy. In addition, recent studies have shown that the overall risk of gallbladder cancer is not increased in patients with small gallbladder polyps, calling into question the rationale for frequent and prolonged follow-up of these common lesions. In 2021, a Society of Radiologists in Ultrasound, or SRU, consensus conference was convened to provide recommendations for the management of incidentally detected gallbladder polyps at US. See also the editorial by Sidhu and Rafailidis in this issue.


Asunto(s)
Enfermedades de la Vesícula Biliar , Neoplasias de la Vesícula Biliar , Neoplasias Gastrointestinales , Pólipos , Humanos , Enfermedades de la Vesícula Biliar/diagnóstico por imagen , Pólipos/diagnóstico por imagen , Pólipos/patología , Neoplasias de la Vesícula Biliar/diagnóstico por imagen , Neoplasias de la Vesícula Biliar/patología , Radiólogos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...