Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Aust Endod J ; 49 Suppl 1: 194-201, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36401559

RESUMEN

This study assessed the influence of pH variation on the volumetric change of EndoSequence BC Sealer compared to AH Plus Jet. Eighteen single-rooted teeth were uniformly prepared and filled with one of the sealers. After 24-h storing, samples were scanned in a micro-CT device. Then, roots were immersed in 20 ml phosphate-buffered saline (PBS) with pH of 5, 7 or 12 at 37°C for 7 and 30 days and rescanned. Statistical analysis was performed using Shapiro-Wilk's test, one-way ANOVA and Tukey's or Student's t-tests (p < 0.05). Differences between sealers were observed only at neutral pH and after 30 days of acidic pH exposure, with a higher loss of EndoSequence (p < 0.05). After 7 days, alkaline pH reduced and increased the volumetric loss of EndoSequence and AH Plus, respectively, compared to neutral pH (p < 0.05). It can be concluded that the pH directly influenced the volumetric change of both tested root canal sealers in different ways.


Asunto(s)
Resinas Epoxi , Materiales de Obturación del Conducto Radicular , Humanos , Microtomografía por Rayos X , Compuestos de Calcio , Silicatos , Concentración de Iones de Hidrógeno , Ensayo de Materiales , Cavidad Pulpar/diagnóstico por imagen
2.
Biophys Rev ; 14(3): 625-633, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35791381

RESUMEN

Synchrotron radiation phase-contrast microtomography is sensitive to low attenuating tissues, giving an alternative visualisation of the sample and being useful for investigating microstructure inside biological specimens without staining them with a contrast medium. The phase-contrast technique has been widely used in the scientific community, as it is a technique associated with radiography and microscopy and able to enhance contrast in soft tissues, specifically at the edges, showing details that could not be seen by the absorption technique. This work aims to show the ability of synchrotron-based phase-contrast microtomography for the visualisation of soft tissues and hard internal structures of millimetre-sized biological organisms. Case studies of the anatomy of Rhodnius prolixus head and Thoropa miliaris tadpole are presented to illustrate the imaging technique.

3.
Phys Med ; 94: 43-52, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34995977

RESUMEN

PURPOSE: In the context of synchrotron microtomography using propagation-based phase-contrast imaging (XSPCT), we evaluated the performance of semiautomatic and automatic image segmentation of soft biological structures by means of Dice Similarity Coefficient (DSC) and volume quantification. METHODS: We took advantage of the phase-contrast effects of XSPCT to provide enhanced object boundaries and improved visualization of the lenses of the frog Thoropa miliaris. Then, we applied semiautomatic segmentation methods 1 and 2 (Interpolation and Watershed, respectively) and method 3, an automatic segmentation algorithm using the U-Net architecture, to the reconstructed images. DSC and volume quantification of the lenses were used to quantify the performance of image segmentation methods. RESULTS: Comparing the lenses segmented by the three methods, the most pronounced difference in volume quantification was between methods 1 and 3: a reduction of 4.24%. Method 1, 2 and 3 obtained the global average DSC of 97.02%, 95.41% and 89.29%, respectively. Although it obtained the lowest DSC, method 3 performed the segmentation in a matter of seconds, while the semiautomatic methods had the average time to segment the lenses around 1 h and 30 min. CONCLUSIONS: Our results suggest that the performance of U-Net was impaired due to the irregularities of the ROI edges mainly in its lower and upper regions, but it still showed high accuracy (DSC = 89.29%) with significantly reduced segmentation time compared to the semiautomatic methods. Besides, with the present work we have established a baseline for future assessments of Deep Neural Networks applied to XSPCT volumes.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Sincrotrones , Microscopía de Contraste de Fase , Redes Neurales de la Computación , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...