1.
JBMR Plus ; 6(2): e10588, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35229065

RESUMEN

In cementless total hip arthroplasty, adequate implant stability is necessary for the success of osseointegration and rapid clinical recovery. Postoperative femoral stem migration, measured by radiostereometric analysis (RSA), defines the initial stability achieved during surgical implantation. In a recent trial of 65 postmenopausal women randomized 1:1 denosumab:placebo, denosumab failed to reduce the initial migration of a cementless femoral stem despite the successful prevention of periprosthetic bone loss. The trial applied the current RSA standard, which examined stem migration on an axis-by-axis basis and did not consider more complex three-dimensional (3D) migration. Therefore, we performed a reanalysis of the trial data using a multivariate hierarchical linear mixed model (LMM). As an additional limitation, the data included influential outliers. Women with normal bone mineral density exhibited significantly (p = 0.036) less stem subsidence compared with osteopenic and osteoporotic women. Denosumab significantly decreased the variance of stem migration in osteopenic and osteoporotic women. The mean magnitude of 3D stem migration did not differ between denosumab-treated and placebo-treated women (p = 0.820). After application of a common statistical definition for RSA outlier identification, there were eight (12%) outliers, six in the placebo group and two in the denosumab group (p = 0.149). After exclusion of the outliers, the repeated LMM analysis demonstrated a trending difference in 3D stem migration (p = 0.086), with a significant difference of z-axis rotation (valgus-varus tilt) of the femoral stem (p = 0.029). The observed effect size was small and without clinically important differences in postoperative recovery. Based on a Monte Carlo simulation with random-generated 3D migration data, multivariate LMM showed greater statistical power than univariate analyses. The application of hierarchical LMM facilitated the analysis of implant migration as a factual 3D event. The observed trend in the lower number of RSA outliers in denosumab-treated subjects warrants powered large-scale trials. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

2.
J Orthop Res ; 37(1): 239-247, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30273993

RESUMEN

We examined the feasibility of radiostereometric analysis (RSA) in the assessment of the initial stability of internally fixed femoral neck fractures. The study included 16 patients (mean age 73 years). During surgery, multiple RSA-beads were inserted on both sides of the fracture. Radiographs for RSA were taken in the supine position within the first 3 days and 6, 12, 24, and 52 weeks after surgery. To detect any inducible motion at the fracture-site, radiographs for RSA were taken with the patient resting or applying a load through the fracture. Fracture loading was achieved by the patient pressing the ipsilateral foot as much as tolerated on a force plate while providing a counterforce through both hands. Micromotion exceeding the precision values of RSA (≥0.3 mm for the translation vector and/or ≥1.2 degrees for the rotation vector) was considered significant. Permanent three-dimensional fracture-site displacement was also recorded. Voluntary loading induced fracture-site micromotion, which exhibited a dichotomous distribution. In patients with uncomplicated fracture union, inducible micromotion was detectable only at baseline-if at all. Conversely, fractures that developed a nonunion were characterized by the continuation of inducible micromotion beyond baseline. Permanent fracture-site displacement was, on average, nearly an order of magnitude greater than the inducible micromotion. Fracture unions were characterized by the cessation of permanent fracture-site displacement by 12 weeks. Nonunions presented as outliers in permanent fracture-site displacement. Large-scale studies are warranted to evaluate whether the detection of inducible micromotion beyond baseline could serve as an indicator of insufficient fixation stability. © 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society.


Asunto(s)
Fracturas del Cuello Femoral/diagnóstico por imagen , Fijación Interna de Fracturas , Complicaciones Posoperatorias/diagnóstico por imagen , Análisis Radioestereométrico , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Fracturas del Cuello Femoral/cirugía , Humanos , Masculino , Persona de Mediana Edad , Soporte de Peso
3.
Clin Orthop Relat Res ; 474(10): 2246-53, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27334320

RESUMEN

BACKGROUND: In clinical trials of THA, model-based radiostereometric analysis (RSA) techniques may be less precise than conventional marker-based RSA for measurement of femoral stem rotation. We verified the accuracy and clinical precision of RSA based on computer-aided design models of a cementless tapered wedge femoral stem. QUESTIONS: We asked: (1) Is the accuracy of model-based RSA comparable to that of marker-based RSA? (2) What is the clinical precision of model-based RSA? METHODS: Model-based RSA was performed using combined three-dimensional computer-aided design models of the stem and head provided by the implant manufacturer. The accuracy of model-based RSA was compared with that of marker-based RSA in a phantom model using micromanipulators for controlled translation in three axes (x, y, z) and rotation around the y axis. The clinical precision of model-based RSA was evaluated by double examinations of patients who had arthroplasties (n = 24) in an ongoing trial. The clinical precision was defined as being at an acceptable level if the number of patients needed for a randomized trial would not differ from a trial done with conventional marker-based RSA (15-25 patients per group). RESULTS: The accuracy of model-based RSA was 0.03 mm for subsidence (translation along the y axis) (95% CI for the difference between RSA measurements and actual displacement measured with micrometers, -0.03-0.00) and 0.39° for rotation around the y axis (95% CI, -0.41 to -0.06). The accuracy of marker-based RSA was 0.06 mm for subsidence (95% CI, -0.04-0.01; p = 0.728 compared with model-based RSA) and 0.18° for the y axis rotation (95% CI, -0.23 to -0.07; p = 0.358). The clinical precision of model-based RSA was 0.14 mm for subsidence (95% CI for the difference between double examinations, -0.02-0.04) and 0.79° for the y axis rotation (95% CI, -0.16-0.18). CONCLUSIONS: The accuracy of model-based RSA for measurement of the y axis rotation was not quite as high as that of marker-based RSA, but its clinical precision is at an acceptable level. CLINICAL RELEVANCE: Model-based RSA may be suitable for clinical trials of cementless tapered wedge femoral stem designs.


Asunto(s)
Artroplastia de Reemplazo de Cadera/psicología , Fémur/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera , Modelos Anatómicos , Análisis Radioestereométrico , Proyectos de Investigación , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos , Simulación por Computador , Femenino , Fémur/fisiopatología , Articulación de la Cadera/fisiopatología , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Diseño de Prótesis , Análisis Radioestereométrico/instrumentación , Reproducibilidad de los Resultados , Rotación , Resultado del Tratamiento
4.
Acta Orthop ; 87(1): 48-54, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26569616

RESUMEN

BACKGROUND AND PURPOSE: Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. PATIENTS AND METHODS: We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy cups with alumina-on-alumina bearings in THA of 34 female patients with a median age of 64 (41-78) years. 10 patients had normal BMD and 24 patients had low systemic BMD (T-score ≤ -1) based on dual-energy X-ray absorptiometry (DXA). Cup migration was followed with RSA for 2 years. Radiographic follow-up was done at a median of 8 (2-10) years. RESULTS: Patients with normal BMD did not show a statistically significant cup migration after the settling period of 3 months, while patients with low BMD had a continuous proximal migration between 3 and 12 months (p = 0.03). These differences in cup migration persisted at 24 months. Based on the perceived risk of cup revision, 14 of the 24 cases were "at risk" (proximal translation of 0.2 to 1.0 mm) in the low-BMD group and 2 of the 10 cases were "at risk" in the normal-BMD group (odds ratio (OR) = 8.0, 95% CI: 1.3-48). The radiographic follow-up showed no radiolucent lines or osteolysis. 2 cups have been revised for fractures of the ceramic bearings, but none for loosening. INTERPRETATION: Low BMD contributed to cup migration beyond the settling period of 3 months, but the migrating cups appeared to osseointegrate eventually.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Densidad Ósea/fisiología , Migración de Cuerpo Extraño/diagnóstico por imagen , Oseointegración/fisiología , Osteoporosis/complicaciones , Absorciometría de Fotón/métodos , Acetábulo , Adulto , Factores de Edad , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Cementos para Huesos , Estudios de Casos y Controles , Cementación , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/epidemiología , Prótesis de Cadera/efectos adversos , Humanos , Hidroxiapatitas/química , Incidencia , Modelos Lineales , Persona de Mediana Edad , Análisis Multivariante , Osteoporosis/diagnóstico por imagen , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico/métodos , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Factores de Tiempo , Titanio/química