Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
BMJ Open ; 14(1): e075141, 2024 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-38238181

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the influence of anxiety and depression on clinician decision-making in patients suffering from chronic eye disease in ophthalmological clinical practice. DESIGN AND SETTING: This multicentre observational study, in collaboration with the WHO, included ophthalmologists and their patients affected by chronic eye disease. States of anxiety and depression were screened with specific questionnaires, the Patient Health Questionnaire-9 (PHQ-9) and Generalized Anxiety Disorder-7 (GAD-7), self-administered by patients before the visit. In the present analysis, we report data from three major eye care centres in Italy between 2021 and 2022. PRIMARY AND SECONDARY OUTCOMES: To assess self-reported changes in ophthalmologists' clinical approach (communication style and their clinical-therapeutic strategies) and decisions after knowing questionnaire scores (primary aim), and to analyse the PHQ-9 and GAD-7 scores in patients with chronic eye diseases (secondary aim). RESULTS: 41 ophthalmologists and 359 patients were included. The results from PHQ-9 and GAD-7 scores showed critical depression and anxiety status scores (PHQ-9 ≥5 and GAD-7 ≥10) in 258 patients. In 74% of cases, no actions were taken by the ophthalmologists based on these scores; in 26% of cases, they changed their clinical approach; and in 14% of cases, they referred the patients for psychological/psychiatric evaluation. CONCLUSIONS: States of anxiety and depression affect many patients with chronic eye conditions and need to be detected and managed early to improve patients' well-being. Providing ophthalmologists with knowledge of their patients' psychological conditions can change the clinical management and attitude towards referral for a psychological evaluation. Further studies are needed to expand our knowledge of how to raise awareness among ophthalmologists regarding multimorbidity of patients suffering from chronic eye diseases in order to achieve better clinical outcomes.


Asunto(s)
Oftalmopatías , Cuestionario de Salud del Paciente , Humanos , Depresión/diagnóstico , Depresión/psicología , Trastornos de Ansiedad/terapia , Trastornos de Ansiedad/psicología , Ansiedad/psicología , Encuestas y Cuestionarios , Toma de Decisiones Clínicas , Oftalmopatías/diagnóstico , Oftalmopatías/terapia
2.
Orphanet J Rare Dis ; 18(1): 223, 2023 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-37525225

RESUMEN

BACKGROUND: Non-syndromic inherited retinal dystrophies (IRDs) such as retinitis pigmentosa or Leber congenital amaurosis generally manifest between early childhood and late adolescence, imposing profound long-term impacts as a result of vision impairment or blindness. IRDs are highly heterogeneous, with often overlapping symptoms among different IRDs, and achieving a definite diagnosis is challenging. This narrative review provides a clinical overview of the non-syndromic generalized photoreceptor dystrophies, particularly retinitis pigmentosa and Leber congenital amaurosis. The clinical investigations and genetic testing needed to establish a diagnosis are outlined, and current management approaches are discussed, focusing on the importance of the involvement of an interdisciplinary team from diagnosis and initial care to long-term follow-up and support. RESULTS: The effective management of IRDs requires a multidisciplinary, and ideally interdisciplinary, team of experts knowledgeable about IRDs, with experienced professionals from fields as diverse as ophthalmology, neuropsychiatry, psychology, neurology, genetics, orthoptics, developmental therapy, typhlology, occupational therapy, otolaryngology, and orientation and mobility specialties. Accurate clinical diagnosis encompasses a range of objective and subjective assessments as a prerequisite for the genetic testing essential in establishing an accurate diagnosis necessary for the effective management of IRDs, particularly in the era of gene therapies. Improvements in genome sequencing techniques, such as next-generation sequencing, have greatly facilitated the complex process of determining IRD-causing gene variants and establishing a molecular diagnosis. Genetic counseling is essential to help the individual and their family understand the condition, the potential risk for offspring, and the implications of a diagnosis on visual prognosis and treatment options. Psychological support for patients and caregivers is important at all stages of diagnosis, care, and rehabilitation and is an essential part of the multidisciplinary approach to managing IRDs. Effective communication throughout is essential, and the patient and caregivers' needs and expectations must be acknowledged and discussed. CONCLUSION: As IRDs can present at an early age, clinicians need to be aware of the clinical signs suggesting visual impairment and follow up with multidisciplinary support for timely diagnoses to facilitate appropriate therapeutic or rehabilitation intervention to minimize vision loss.


Asunto(s)
Amaurosis Congénita de Leber , Distrofias Retinianas , Retinitis Pigmentosa , Adolescente , Humanos , Preescolar , Amaurosis Congénita de Leber/diagnóstico , Amaurosis Congénita de Leber/genética , Amaurosis Congénita de Leber/terapia , Distrofias Retinianas/diagnóstico , Distrofias Retinianas/genética , Distrofias Retinianas/terapia , Retinitis Pigmentosa/diagnóstico , Retinitis Pigmentosa/genética , Retinitis Pigmentosa/terapia , Pruebas Genéticas , Terapia Genética , Mutación
3.
J Med Syst ; 47(1): 11, 2023 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-36645535

RESUMEN

To evaluate usability of and satisfaction with OrCam MyEye, a finger-size wearable assistive technology device for visually impaired during real-world tasks. This prospective multicenter study was conducted on visually impaired people recruited from 5 vision rehabilitation centers. Patients performed real-world tasks such as near and distance reading, money handling, colour identification and face recognition in 2 different scenarios: without using any low vision aid and with OrCam. System Usability Scale (SUS), Patient's Global Impression of Change (PGIC), the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0) and the Psychosocial Impact of Assistive Devices Scale (PIADS) were administered after the use of the OrCam device. Among the 100 participants, use of OrCam MyEye device improved many daily-living tasks (F = 1.67, P < .05), and in particular reading and face recognition. Multivariate logistic regression showed that age and visual field defect explained 89% of the variation in efficacy of the device. Nearly half (45%) of the participants indicated a positive rating with the SUS. The PGIC rates showed a minimal improvement with a mean score of 4.2 (SD:1.8). The most highlighted parameter with the QUEST 2.0 test was "ease of use" in 58% (48 subjects). The PIADS indicator showed that the device positively impacted on the daily-living tasks of users (r2 = 0.72, P < .05). Regression modelling demonstrated a good relation between the questionnaires scores and demographic, disease and visual factors (P < .05). OrCam MyEye allowed visually impaired people to read, handle money and face recognition independently. This device may offer to these subjects to be independent.


Asunto(s)
Equipos de Comunicación para Personas con Discapacidad , Dispositivos de Autoayuda , Personas con Daño Visual , Humanos , Satisfacción del Paciente , Estudios Prospectivos , Encuestas y Cuestionarios
4.
Eur J Ophthalmol ; 32(4): 1966-1970, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34516321

RESUMEN

PURPOSE: To evaluate the awareness of ophthalmologists about assessing the mental health of patients and usefulness of the Patient Health Questionnaire (PHQ-9) and Generalized Anxiety Disorder (GAD-7) survey. METHODS: This web-based survey was performed in 2020 at an eye hospital in Saudi Arabia. Participants included ophthalmologists and physicians. Participants were queried on the need to assess mental health of patients, usefulness of the screening tool, and barriers to assessment. Their responses were graded on a Likert scale and Rasch analysis was performed. RESULTS: Of the 100 participants, 72 were aware of assessing mental health of eye patients and 82 expressed about limited skills for such assessment. The median score for perceived usefulness of the PHQ-9 as screening tool to suspect depression was -1.0 (inter quartile range, -1.0: 0.0) [Mean Rasch score = -0.735]. The median score of perceived usefulness for the GAD-7 as screening tool to suspect anxiety was -1.0 (inter quartile range, -1.0: 0.0) [Mean Rasch score = -0.695]. The PHQ-9 related score was significantly correlated to "30-39 years" age group (Kruskal Wallis p = 0.04) and non-Saudi professionals (Mann Whitney p = 0.005). The GAD-7 related score was significantly correlated to non-Saudi professionals (Mann Whitney p = 0.04). The mental health related score was significantly and negatively correlated to the "40-59 years" age group (Kruskal Wallis p = 0.04). CONCLUSIONS: Although awareness of mental health assessment was high, eyecare professionals felt with inadequate training for performing the screening. PHQ-9 seems to be more acceptable to screen for depression than GAD-7 for screening anxiety.


Asunto(s)
Oftalmopatías , Oftalmólogos , Trastornos de Ansiedad/diagnóstico , Trastornos de Ansiedad/psicología , Depresión/diagnóstico , Humanos , Salud Mental , Cuestionario de Salud del Paciente
5.
Eur J Ophthalmol ; 30(5): 1014-1018, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31113297

RESUMEN

PURPOSE: The Veterans Affairs Low-Vision Visual Functioning Questionnaire-48 is among the most validated tools to collect patient-reported outcomes in a low-vision population. We have aimed to conduct a pilot validation of the Italian version of the Veterans Affairs Low-Vision Visual Functioning Questionnaire-48. METHODS: The Veterans Affairs Low-Vision Visual Functioning Questionnaire-48 was translated using a standardized procedure and then administered to consecutive low-vision patients attending rehabilitation services in three centers. Patients were interviewed by a trained psychologist regarding the individual items of the tool. RESULTS: We included 131 patients with a mean visual acuity of 0.91 logMAR (standard deviation: 0.42 logMAR), mostly affected by age-related macular degeneration. The Veterans Affairs Low-Vision Visual Functioning Questionnaire-48 showed high internal consistency (Cronbach's alpha: 0.98) and good item-test and item-rest correlation (median: 0.73 and 0.71, respectively). Both the overall score and the subscale (reading, visual motor, mobility and visual information) scores significantly correlated with visual acuity, reading acuity and speed. Reading speed achieved the best absolute correlation with the Veterans Affairs Low-Vision Visual Functioning Questionnaire-48 scores (Spearman r: 0.39-0.49). CONCLUSION: The Italian version of the Veterans Affairs Low-Vision Visual Functioning Questionnaire-48 is a valid tool to assess patients attending low-vision services. Revising a few items may further improve the tool.


Asunto(s)
Actividades Cotidianas/psicología , Lenguaje , Perfil de Impacto de Enfermedad , Encuestas y Cuestionarios , Baja Visión/psicología , Anciano , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Proyectos Piloto , Calidad de Vida/psicología , Estados Unidos , United States Department of Veterans Affairs , Baja Visión/rehabilitación , Agudeza Visual/fisiología
6.
Biomed Eng Online ; 16(1): 29, 2017 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-28209171

RESUMEN

BACKGROUND: Haemodynamic performance of heart valve prosthesis can be defined as its ability to fully open and completely close during the cardiac cycle, neither overloading heart work nor damaging blood particles when passing through the valve. In this perspective, global and local flow parameters, valve dynamics and blood damage safety of the prosthesis, as well as their mutual interactions, have all to be accounted for when assessing the device functionality. Even though all these issues have been and continue to be widely investigated, they are not usually studied through an integrated approach yet, i.e. by analyzing them simultaneously and highlighting their connections. RESULTS: An in vitro test campaign of flow through a bileaflet mechanical heart valve (Sorin Slimline 25 mm) was performed in a suitably arranged pulsatile mock loop able to reproduce human systemic pressure and flow curves. The valve was placed in an elastic, transparent, and anatomically accurate model of healthy aorta, and tested under several pulsatile flow conditions. Global and local hydrodynamics measurements and leaflet dynamics were analysed focusing on correlations between flow characteristics and valve motion. The haemolysis index due to the valve was estimated according to a literature power law model and related to hydrodynamic conditions, and a correlation between the spatial distribution of experimental shear stress and pannus/thrombotic deposits on mechanical valves was suggested. As main and general result, this study validates the potential of the integrated strategy for performance assessment of any prosthetic valve thanks to its capability of highlighting the complex interaction between the different physical mechanisms that govern transvalvular haemodynamics. CONCLUSIONS: We have defined an in vitro procedure for a comprehensive analysis of aortic valve prosthesis performance; the rationale for this study was the belief that a proper and overall characterization of the device should be based on the simultaneous measurement of all different quantities of interest for haemodynamic performance and the analysis of their mutual interactions.


Asunto(s)
Válvula Aórtica/fisiología , Prótesis Valvulares Cardíacas , Modelos Cardiovasculares , Aorta/metabolismo , Velocidad del Flujo Sanguíneo/fisiología , Hemólisis , Humanos , Modelos Anatómicos , Diseño de Prótesis , Flujo Pulsátil/fisiología , Estrés Mecánico
7.
Rev Sci Instrum ; 87(3): 035119, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27036831

RESUMEN

In recent years, there has been a renewed interest in the impact of turbulence on aquatic organisms. In response to this interest, a novel instrument has been constructed, TURBOGEN, that generates turbulence in water volumes up to 13 l. TURBOGEN is fully computer controlled, thus, allowing for a high level of reproducibility and for variations of the intensity and characteristics of turbulence during the experiment. The calibration tests, carried out by particle image velocimetry, showed TURBOGEN to be successful in generating isotropic turbulence at the typical relatively low levels of the marine environment. TURBOGEN and its sizing have been devised with the long-term scope of analyzing in detail the molecular responses of plankton to different mixing regimes, which is of great importance in both environmental and biotechnological processes.


Asunto(s)
Computadores , Hidrodinámica , Plancton , Calibración , Diseño de Equipo , Cinética , Agua
8.
Multisens Res ; 28(3-4): 309-30, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26288902

RESUMEN

This review has the purpose of retracing the work of Professor Bernard Sabel and his group over the last 2-3 decades, in order to understand how they achieved formulation of the 'Residual Vision Activation Theory'. The methodology proposed is described, from the first studies in 1995 with High Resolution Perimetry requiring a six-months training period, to the new technologies, such as repetitive transorbital Alternating Current Stimulation, that require ten days of training. Vision restoration therapy has shown improvement in visual responses irrespective of age at the training, lesion aetiology and site of lesion. The hypothesis that visual training may induce network plasticity, improving neuronal networks in cortical and subcortical areas of both hemispheres, appears to be confirmed by recent studies including observation of the cerebral activity by fMRI and EEG. However, the results are quite variable and the mechanisms that influence cerebral activity are still unclear. The residual vision activation theory has been much criticized, both for its methodology and analysis of the results, but it gave a new impulse to the research in this area, stimulating more studies on induced cerebral plasticity.


Asunto(s)
Plasticidad Neuronal/fisiología , Baja Visión/diagnóstico , Campos Visuales/fisiología , Humanos , Imagen por Resonancia Magnética , Baja Visión/fisiopatología , Pruebas del Campo Visual
9.
J Biomech ; 47(12): 3120-8, 2014 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-25001203

RESUMEN

Aortic root dilation and propensity to dissection are typical manifestations of the Marfan Syndrome (MS), a genetic defect leading to the degeneration of the elastic fibres. Dilation affects the structure of the flow and, in turn, altered flow may play a role in vessel dilation, generation of aneurysms, and dissection. The aim of the present work is the investigation in-vitro of the fluid dynamic modifications occurring as a consequence of the morphological changes typically induced in the aortic root by MS. A mock-loop reproducing the left ventricle outflow tract and the aortic root was used to measure time resolved velocity maps on a longitudinal symmetry plane of the aortic root. Two dilated model aortas, designed to resemble morphological characteristics typically observed in MS patients, have been compared to a reference, healthy geometry. The aortic model was designed to quantitatively reproduce the change of aortic distensibility caused by MS. Results demonstrate that vorticity released from the valve leaflets, and possibly accumulating in the root, plays a fundamental role in redirecting the systolic jet issued from the aortic valve. The altered systolic flow also determines a different residual flow during the diastole.


Asunto(s)
Aorta/fisiología , Válvula Aórtica/fisiología , Síndrome de Marfan/fisiopatología , Circulación Coronaria , Humanos , Hidrodinámica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...