1.
Anaesthesia ; 71(4): 437-42, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26849094

RESUMEN

We compared the performance of the McGrath® Series 5 videolaryngoscope with the Macintosh laryngoscope in 49 patients without suspected cervical spine pathology, whose cervical spine was immobilised using a semi-rigid collar. The primary outcome was the view obtained at laryngoscopy. Secondary outcomes included time to tracheal intubation, rates of successful intubation and incidence of complications. In all patients, the view was better (92%) or the same (8%) in the McGrath group versus the Macintosh group (p < 0.01). There were no failed intubations in the McGrath group and seven (28%) in the Macintosh group (p < 0.02). There was no statistical difference in time taken to intubate or incidence of complications. We conclude that the McGrath® Series 5 is a superior laryngoscope when cervical spine immobilisation is maintained during tracheal intubation.


Asunto(s)
Vértebras Cervicales/fisiopatología , Inmovilización , Laringoscopios , Laringoscopía/instrumentación , Grabación en Video , Estudios Cruzados , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad
2.
Anaesthesia ; 70(11): 1281-5, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26336853

RESUMEN

We compared the McGrath MAC(®) videolaryngoscope when used as both a direct and an indirect laryngoscope with a standard Macintosh laryngoscope in patients without predictors of a difficult tracheal intubation. We found higher median Intubation Difficulty Scores with the McGrath MAC as a direct laryngoscope, 1 (0-3 [0-5]) than when using it as an indirect videolaryngoscope, 0 (0-1 [0-5]) or when using the Macintosh laryngoscope, 0 (0-1 [0-5]), p = 0.04. This was mirrored in the subjective user reporting, scored out of 10, of difficulty for each method 3.0 (2.0-3.4 [0.5-80]); 2.0 (1.0-3.9 [0-70]) and 2.0 (1.0-3.3 [0-70]), respectively (p = 0.01). This difficulty is in part explained by the poorer laryngeal views recorded using the Cormack and Lehane classification system (p < 0.001) and reflected in the higher than normal operator force required (25%, 4%, 8% for each method, respectively, p < 0.001) and the increased use of rigid intubation aids (21%, 6%, 2%, respectively, p < 0.001). There was no difference between the groups in time taken to intubate or incidence of complications. There was no statistical difference in the performances as measured between the McGrath MAC used as an indirect videolaryngoscope and the Macintosh laryngoscope. We cannot recommend that the McGrath videolaryngoscope be used as a direct laryngscopic device in place of the Macintosh.


Asunto(s)
Intubación Intratraqueal/instrumentación , Laringoscopios , Laringoscopía/instrumentación , Grabación en Video/instrumentación , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad