Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 23(10)2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-37430546

RESUMEN

(1) Background: Consumer smartwatches may be a helpful tool to screen for atrial fibrillation (AF). However, validation studies on older stroke patients remain scarce. The aim of this pilot study from RCT NCT05565781 was to validate the resting heart rate (HR) measurement and the irregular rhythm notification (IRN) feature in stroke patients in sinus rhythm (SR) and AF. (2) Methods: Resting clinical HR measurements (every 5 min) were assessed using continuous bedside ECG monitoring (CEM) and the Fitbit Charge 5 (FC5). IRNs were gathered after at least 4 h of CEM. Lin's concordance correlation coefficient (CCC), Bland-Altman analysis, and mean absolute percentage error (MAPE) were used for agreement and accuracy assessment. (3) Results: In all, 526 individual pairs of measurements were obtained from 70 stroke patients-age 79.4 years (SD ± 10.2), 63% females, BMI 26.3 (IQ 22.2-30.5), and NIHSS score 8 (IQR 1.5-20). The agreement between the FC5 and CEM was good (CCC 0.791) when evaluating paired HR measurements in SR. Meanwhile, the FC5 provided weak agreement (CCC 0.211) and low accuracy (MAPE 16.48%) when compared to CEM recordings in AF. Regarding the accuracy of the IRN feature, analysis found a low sensitivity (34%) and high specificity (100%) for detecting AF. (4) Conclusion: The FC5 was accurate at assessing the HR during SR, but the accuracy during AF was poor. In contrast, the IRN feature was acceptable for guiding decisions regarding AF screening in stroke patients.


Asunto(s)
Fibrilación Atrial , Neoplasias de la Mama , Accidente Cerebrovascular , Anciano , Femenino , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Determinación de la Frecuencia Cardíaca , Proyectos Piloto , Accidente Cerebrovascular/diagnóstico , Anciano de 80 o más Años , Ensayos Clínicos Controlados Aleatorios como Asunto
3.
Clin Case Rep ; 5(7): 1103-1106, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28680604

RESUMEN

Atrial flutter ablation in CHD (Congenital Heart Disease) patients is a challenging procedure because of the possibility of multiple circuits. Electroanatomical mapping and pacing maneuvers are crucial to determine critical isthmus. Moreover, vascular abnormalities and residual cardiac defects need to be known before the ablation to decide the better strategy for ablation.

4.
J Cardiovasc Electrophysiol ; 28(1): 126-131, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27759948

RESUMEN

BACKGROUND: Ablation in aortic cusps could be necessary in up to 15% of the patients, especially in para-Hisian atrial tachycardia and ventricular arrhythmias arising from outflow tracts. Risk of coronary damage has led to recommendation of systematic coronary angiography (CA) during the procedure. Other image tests as intravascular (ICE) or transesophageal echocardiography (TEE) have been proposed. Both methods have limitations: additional vascular access for ICE and need for additional CA in some patients in case of TEE. We describe an alternative method to assess relation of catheter tip and coronary ostia during ablation in aortic cusps without additional vascular accesses by performing selective angiography with the ablation catheter. METHODS AND RESULTS: We prospectively evaluated 12 consecutive patients (69.3 ± 8.5, 6 female) who underwent ablation in right (1), left (5), and noncoronary cusps (6). We performed angiography through the ablation cooled tip radiofrequency catheter at the ablation site. Ablation was effective in 91.6% of the patients (3 patients needed additional ablation out of coronary cusps: pulmonary cusp, right ventricular outflow tract (RVOT), and coronary sinus and 1 patient underwent a second procedure because recurrence). No complications occurred neither during procedure nor follow-up (6.2 ± 3.8 months). No technical problems occurred with the ablation catheter after contrast injection. CONCLUSION: Selective angiography through a cooled-tip radiofrequency ablation catheter is feasible to assess relation of coronary ostia and ablation site when ablation in aortic cusps. It allows continuous real-time assessment of this relation, avoids the need for additional vascular accesses and no complications occurred in our series.


Asunto(s)
Válvula Aórtica/cirugía , Arritmias Cardíacas/cirugía , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Angiografía Coronaria/instrumentación , Potenciales de Acción , Adulto , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos
5.
Thromb Haemost ; 115(6): 1129-37, 2016 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-26962963

RESUMEN

Therapeutic fibrinolysis is ineffective in 40 % of ST-segment elevation acute myocardial infarction (STEMI) patients, but understanding of the mechanisms is incomplete. It was our aim to compare the composition of coronary thrombus in lysis-resistant STEMI patients with that of lysis-sensitive patients. Intracoronary thrombi (n=64) were obtained by aspiration in consecutive STEMI patients. Of them, 20 had received fibrinolysis and underwent rescue percutaneous coronary intervention (r-PCI, lysis-resistant patients) and 44 underwent primary PCI (p-PCI). Lysis-sensitivity was determined in vitro by clot permeability measurements and turbidimetric lysis in plasma of 44 patients undergoing p-PCI and 20 healthy donors. Clot-lysis sensitivity was defined as a clot-lysis time not greater than 1 SD over the mean of healthy donors. Coronary thrombus composition in 20 lysis-resistant and in 20 lysis-sensitive patients was analysed by immunofluorescence with confocal microscopy. Plasma biomarkers (P-selectin, VWF, PAI-1, t-PA, D-dimer, TF pathway markers, plasmin and CD34+) were measured simultaneously on peripheral blood. Lysis-resistant clots had higher levels of fibrin (p=0.02), P-selectin (p=0.03) and VWF (p=0.01) than lysis-sensitive clots. Among thrombi obtained ≤ 6 hours after onset of symptoms, those from lysis-resistant patients showed a higher content in fibrin than those from p-PCI patients (p=0.01). Plasma PAI-1 (p=0.02) and D-dimer levels were significantly higher (p=0.003) in lysis-resistant patients, whereas plasmin levels were lower (p=0.03). Multivariate analysis showed the content of fibrin and VWF within thrombus as predictors of thrombolysis resistance. In conclusion, coronary thrombi in STEMI patients resistant to fibrinolysis are characterised by higher fibrin, P-selectin and VWF content than lysis-sensitive thrombi.


Asunto(s)
Trombosis Coronaria/sangre , Trombosis Coronaria/tratamiento farmacológico , Fibrina/metabolismo , Selectina-P/sangre , Infarto del Miocardio con Elevación del ST/sangre , Infarto del Miocardio con Elevación del ST/tratamiento farmacológico , Terapia Trombolítica , Factor de von Willebrand/metabolismo , Adulto , Anciano , Biomarcadores/sangre , Trombosis Coronaria/cirugía , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST/cirugía , Trombectomía , Factores de Tiempo , Insuficiencia del Tratamiento
6.
Bol Asoc Med P R ; 107(3): 24-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26742192

RESUMEN

Foreign body aspiration can be a life-threatening emergency. An aspirated solid or semi-solid object may lodge in the larynx, trachea or other breathing airways. If the object is large enough to cause nearly complete obstruction of the airway, asphyxia may rapidly cause death. We report a 19-year old man admitted with right lower lobe pneumonia who spontaneously expelled a foreign body, one day after admission and glucocorticoids administration. Glucocorticoids should be considered in foreign body aspiration management because improvement of the inflammatory reaction may facilitate expontaneous expulsion or foreign body extraction


Asunto(s)
Antiinflamatorios/uso terapéutico , Cuerpos Extraños/tratamiento farmacológico , Metilprednisolona/uso terapéutico , Neumonía por Aspiración/tratamiento farmacológico , Acetaminofén/administración & dosificación , Acetaminofén/uso terapéutico , Analgésicos/uso terapéutico , Antibacterianos/uso terapéutico , Antiinflamatorios/administración & dosificación , Azitromicina/administración & dosificación , Azitromicina/uso terapéutico , Broncodilatadores/administración & dosificación , Broncodilatadores/uso terapéutico , Ceftriaxona/administración & dosificación , Ceftriaxona/uso terapéutico , Tos/etiología , Quimioterapia Combinada , Disnea/etiología , Fluoroquinolonas/administración & dosificación , Fluoroquinolonas/uso terapéutico , Cuerpos Extraños/diagnóstico por imagen , Humanos , Levalbuterol/administración & dosificación , Levalbuterol/uso terapéutico , Masculino , Metilprednisolona/administración & dosificación , Moxifloxacino , Juego e Implementos de Juego , Neumonía por Aspiración/etiología , Ranitidina/administración & dosificación , Ranitidina/uso terapéutico , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...