Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Clin Anesth ; 32: 54-8, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27290945

RESUMEN

STUDY OBJECTIVE: Measure the displacements of endotracheal tube (ETT) tip displacement during head and neck movements. DESIGN: Observational study. SETTING: Ear-nose-throat (ENT) and neurosurgery operating room. PATIENTS: We performed a maximal head-neck movement trial on 50 adult patients, American Society of Anaesthesiologists 1 or 2. Patients with body mass index >35 kg · m(-2), height <150 cm, airway malformations, pulmonary diseases, difficulties in neck flexion or extension, previous ENT surgery or radiotherapy, gastroesophageal reflux, or dental instability were excluded from the study. INTERVENTIONS: ENT and neurosurgery. MEASUREMENTS: We measured the change in distance between the ETT tip and the carina, using a fiberscope through the ETT. RESULTS: After intubation, a wide disparity of tube tip distance to the carina in the neutral position was noted with a median of 5.0 (3.5-7.0) cm. Cephalad tube movement was documented following maximal head and neck extension in 34 (68%) patients and right head rotation in 25 patients (50%). Caudal tube displacement was due to maximal head and neck flexion in 38 patients (76%) and left head rotation in 25 patients (50%). Selective right main bronchus intubation was noted in 2 (4%) patients after maximal head extension. CONCLUSION: Maximal head and neck movements led to unpredictable tube displacements. Proper reassessment of tube positioning after head and neck movement of intubated patients is therefore mandatory.


Asunto(s)
Movimientos de la Cabeza , Intubación Intratraqueal/instrumentación , Posicionamiento del Paciente/efectos adversos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento , Cuello , Postura
2.
Eur J Anaesthesiol ; 31(9): 499-504, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25010745

RESUMEN

BACKGROUND: Multiple electrode aggregometry (MEA) is a point-of-care test evaluating platelet function and the efficacy of platelet inhibitors. In MEA, electrical impedance of whole blood is measured after addition of a platelet activator. Reduced impedance implies platelet dysfunction or the presence of platelet inhibitors. MEA plays an increasingly important role in the management of perioperative platelet dysfunction. In vitro, midazolam, propofol, lidocaine and magnesium have known antiplatelet effects and these may interfere with MEA interpretation. OBJECTIVE: To evaluate the extent to which MEA is modified in the presence of these drugs. DESIGN: An in-vitro study using blood collected from healthy volunteers. SETTING: Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland, 2010 to 2011. PATIENTS: Twenty healthy volunteers. INTERVENTION: Measurement of baseline MEA was using four activators: arachidonic acid, ADP, TRAP-6 and collagen. The study drugs were then added in three increasing, clinically relevant concentrations. MAIN OUTCOME MEASURE: MEA was compared with baseline for each study drug. RESULTS: Midazolam, propofol and lidocaine showed no effect on MEA at any concentration. Magnesium at 2.5 mmol l had a significant effect on the ADP and TRAP tests (31 ±â€Š13 and 96 ±â€Š39 AU, versus 73 ±â€Š21 and 133 ±â€Š28 AU at baseline, respectively), and a less pronounced effect at 1 mmol l on the ADP test (39 ±â€Š0 AU). CONCLUSION: Midazolam, propofol and lidocaine do not interfere with MEA measurement. In patients treated with high to normal doses of magnesium, MEA results for ADP and TRAP-tests should be interpreted with caution. TRIAL REGISTRATION: Clinicaltrials.gov (no. NCT01454427).


Asunto(s)
Adenosina Difosfato/metabolismo , Anestésicos/farmacología , Agregación Plaquetaria/efectos de los fármacos , Adulto , Anestésicos/administración & dosificación , Procedimientos Quirúrgicos Cardíacos/métodos , Relación Dosis-Respuesta a Droga , Impedancia Eléctrica , Electrodos , Femenino , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad
3.
Clin Orthop Relat Res ; 472(5): 1384-93, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23928707

RESUMEN

BACKGROUND: The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. QUESTIONS/PURPOSES: We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. METHODS: Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. RESULTS: With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. CONCLUSIONS: Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Asunto(s)
Amidas/administración & dosificación , Anestésicos Locales/administración & dosificación , Artroplastia de Reemplazo de Rodilla/efectos adversos , Nervio Femoral , Articulación de la Rodilla/cirugía , Bloqueo Nervioso/métodos , Dolor Postoperatorio/prevención & control , Anciano , Analgésicos Opioides/uso terapéutico , Anestésicos Locales/efectos adversos , Fenómenos Biomecánicos , Método Doble Ciego , Terminación Anticipada de los Ensayos Clínicos , Femenino , Humanos , Infusiones Parenterales , Inyecciones , Articulación de la Rodilla/inervación , Articulación de la Rodilla/fisiopatología , Tiempo de Internación , Masculino , Persona de Mediana Edad , Bloqueo Nervioso/efectos adversos , Ontario , Dimensión del Dolor , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología , Alta del Paciente , Estudios Prospectivos , Rango del Movimiento Articular , Recuperación de la Función , Ropivacaína , Tamaño de la Muestra , Factores de Tiempo , Resultado del Tratamiento
5.
Eur J Anaesthesiol ; 27(10): 890-6, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20601892

RESUMEN

BACKGROUND AND OBJECTIVE: Arterial base excess and lactate levels are key parameters in the assessment of critically ill patients. The use of venous blood gas analysis may be of clinical interest when no arterial blood is available initially. METHODS: Twenty-four pigs underwent progressive normovolaemic haemodilution and subsequent progressive haemorrhage until the death of the animal. Base excess and lactate levels were determined from arterial and central venous blood after each step. In addition, base excess was calculated by the Van Slyke equation modified by Zander (BE(z)). Continuous variables were summarized as mean +/- SD and represent all measurements (n = 195). RESULTS: Base excess according to National Committee for Clinical Laboratory Standards for arterial blood was 2.27 +/- 4.12 versus 2.48 +/- 4.33 mmol(-l) for central venous blood (P = 0.099) with a strong correlation (r(2) = 0.960, P < 0.001). Standard deviation of the differences between these parameters (SD-DIFBE) did not increase (P = 0.355) during haemorrhage as compared with haemodilution. Arterial lactate was 2.66 +/- 3.23 versus 2.71 +/- 2.80 mmol(-l) in central venous blood (P = 0.330) with a strong correlation (r(2) = 0.983, P < 0.001). SD-DIFLAC increased (P < 0.001) during haemorrhage. BE(z) for central venous blood was 2.22 +/- 4.62 mmol(-l) (P = 0.006 versus arterial base excess according to National Committee for Clinical Laboratory Standards) with strong correlation (r(2) = 0.942, P < 0.001). SD-DIFBE(z)/base excess increased (P < 0.024) during haemorrhage. CONCLUSION: Central venous blood gas analysis is a good predictor for base excess and lactate in arterial blood in steady-state conditions. However, the variation between arterial and central venous lactate increases during haemorrhage. The modification of the Van Slyke equation by Zander did not improve the agreement between central venous and arterial base excess.


Asunto(s)
Desequilibrio Ácido-Base/sangre , Análisis de los Gases de la Sangre/métodos , Hemorragia/fisiopatología , Animales , Enfermedad Crítica , Hemodilución/métodos , Lactatos/sangre , Porcinos
6.
J Cardiothorac Vasc Anesth ; 24(2): 250-6, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19700347

RESUMEN

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.


Asunto(s)
Cateterismo Periférico/métodos , Cateterismo Periférico/normas , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/normas , Arteria Pulmonar/fisiología , Punciones , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Cateterismo Periférico/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/instrumentación , Estudios Prospectivos , Termodilución/instrumentación , Termodilución/métodos
7.
Anesthesiology ; 107(3): 442-51, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17721247

RESUMEN

BACKGROUND: High-molecular-weight, low-substituted hydroxyethyl starch (HES) may not affect blood coagulation more than low-molecular-weight, low-substituted HES. The authors assessed in vivo the effect of a lowered C2/C6 ratio on pharmacokinetic characteristics and the impact on blood coagulation of high-molecular-weight, low-substituted HES. METHODS: A prospective, randomized, parallel study in 30 pigs compared HES 650/0.42/2.8 with HES 650/0.42/5.6. Before, during, and after infusion of 30 ml/kg body weight HES, blood samples were collected over 630 min to measure HES concentrations and plasmatic coagulation and to assess blood coagulation in whole blood by Thrombelastography (TEG; Haemoscope Corporation, Niles, IL). Pharmacokinetic parameters were estimated using a two-compartment model. RESULTS: The elimination constant was 0.009 +/- 0.001 min(-1) for HES 650/0.42/2.8 and 0.007 +/- 0.001 min(-1) for HES 650/0.42/5.6 (P < 0.001); the area under the plasma concentration-time curve was 1,374 +/- 340 min x g/l for HES 650/0.42/2.8 and 1,697 +/- 411 min x g/l for HES 650/0.42/5.6 (P = 0.026). The measured plasma HES concentrations were not different between HES 650/0.42/2.8 and HES 650/0.42/5.6. Both HES solutions equally affected blood coagulation: Thrombelastographic coagulation index decreased similarly at the end of infusion of HES 650/0.42/2.8 and at the end of infusion of HES 650/0.42/5.6 (P = 0.293). Also, activated partial thromboplastin and prothrombin times increased similarly for HES 650/0.42/2.8 and HES 650/0.42/5.6 (P = 0.831). CONCLUSION: Reducing the C2/C6 ratio in high-molecular, low-substituted HES solutions results in a slightly faster HES elimination. However, the blood coagulation compromising effect was unaffected.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Derivados de Hidroxietil Almidón/farmacocinética , Sustitutos del Plasma/farmacocinética , Albúminas/efectos de los fármacos , Animales , Área Bajo la Curva , Pruebas de Coagulación Sanguínea , Hemoglobinas/efectos de los fármacos , Derivados de Hidroxietil Almidón/sangre , Derivados de Hidroxietil Almidón/química , Peso Molecular , Sustitutos del Plasma/química , Sustitutos del Plasma/metabolismo , Estudios Prospectivos , Distribución Aleatoria , Relación Estructura-Actividad , Porcinos , Tromboelastografía/métodos , Factores de Tiempo
8.
Anesthesiology ; 106(1): 132-43, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17197855

RESUMEN

BACKGROUND: Carboxymethyl starch (CMS) and carboxymethylated hydroxyethyl starch (CM-HES) might offer advantages over hydroxyethyl starch (HES) with regard to their volume expansion effect and their pharmacokinetic characteristics. The goal of the current study was to determine the pharmacokinetics of CMS and CM-HES and to investigate their influence on blood coagulation in comparison with the standard low-molecular, low-substituted HES (130/0.42) used in Europe. METHODS: The study was conducted as a randomized, blinded, parallel three-group study in 30 pigs. Twenty ml/kg of 6% HES (control), 6% CMS, or 6% CM-HES was infused as a single dose, and serial blood sampling was performed over 20 h to measure plasma concentration and molecular weight and to assess blood coagulation. Concentration-effect relations were assessed by pharmacokinetic-pharmacodynamic analysis. RESULTS: CMS and CM-HES showed significantly higher plasma concentrations and molecular weights over 20 h (P for both<0.001) with smaller volumes of distribution and longer elimination rates during the terminal phase (P for both<0.01) when compared with HES. CMS and CM-HES impaired whole blood coagulation more than HES as assessed by Thrombelastograph analysis (Haemoscope Corporation, Niles, IL). However, similar effects of all three starch preparations on blood coagulation were found when related to the plasma concentrations in mass units. CONCLUSIONS: Carboxymethylation of starch results in an increased intravascular persistence and a slower fragmentation compared with HES. The greater impairment of blood coagulation by CMS and CM-HES seems to be caused by the higher plasma concentrations.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Sustitutos Sanguíneos/farmacocinética , Derivados de Hidroxietil Almidón/farmacocinética , Almidón/análogos & derivados , Animales , Coloides , Hemodilución , Hemoglobinas/análisis , Derivados de Hidroxietil Almidón/farmacología , Presión Osmótica , Almidón/farmacocinética , Almidón/farmacología , Porcinos
9.
Anesthesiology ; 105(6): 1228-37, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17122586

RESUMEN

BACKGROUND: Hydroxyethyl starches (HES) with lower impact on blood coagulation but longer intravascular persistence are of clinical interest. The current study aimed to investigate in vivo the isolated effect of molecular weight on blood coagulation during progressive acute normovolemic hemodilution. METHODS: Twenty-four pigs were normovolemically hemodiluted up to a total exchange of 50 ml . kg . body weight of HES 650/0.42 or HES 130/0.42. Serial blood sampling was performed to measure HES plasma concentration and to assess blood coagulation. Concentration-effect relations were analyzed by linear regression, followed by the Student t test on regression parameters. RESULTS: Blood coagulation was increasingly compromised toward hypocoagulability by acute normovolemic hemodilution with both treatments (P < 0.01). Significantly greater impact on activated partial thromboplastin time (P = 0.04) and significantly stronger decrease of maximal amplitude (P = 0.04), angle alpha (P = 0.02), and coagulation index (P = 0.02) was seen after acute normovolemic hemodilution with HES 650/0.42 as compared with HES 130/0.42. Except for factor VIII (P = 0.04), no significant differences between both treatments were observed when relating antihemostatic effects to HES plasma concentrations (P > 0.05). A significantly lesser decrease of hemoglobin concentration has been found with HES 650/0.42 as compared with HES 130/0.42 (P < 0.01) in relation to HES plasma concentrations. CONCLUSION: High-molecular-weight HES (650/0.42) shows a moderately greater antihemostatic effect than low-molecular-weight HES (130/0.42) during acute normovolemic hemodilution. However, similar effects on hemostasis were observed with both treatments when observed antihemostatic effects were related to measured HES plasma concentrations. In addition, HES 650/0.42 may have a lower efficacy in immediately restoring plasma volume.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Hemodilución , Derivados de Hidroxietil Almidón/química , Derivados de Hidroxietil Almidón/farmacología , Sustitutos del Plasma/química , Sustitutos del Plasma/farmacología , Animales , Viscosidad Sanguínea , Derivados de Hidroxietil Almidón/farmacocinética , Peso Molecular , Tiempo de Tromboplastina Parcial , Sustitutos del Plasma/farmacocinética , Tiempo de Protrombina , Respiración Artificial , Porcinos , Tromboelastografía
10.
Anesth Analg ; 100(2): 580-584, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15673897

RESUMEN

Positive end-expiratory pressure (PEEP) applied during induction of anesthesia prevents atelectasis formation and increases the duration of nonhypoxic apnea in nonobese patients. PEEP also prevents atelectasis formation in morbidly obese patients. Because morbidly obese patients have difficult airway management more often and because arterial desaturation develops rapidly, we studied the clinical benefit of PEEP applied during anesthesia induction. Thirty morbidly obese patients were randomly allocated to one of two groups. In the PEEP group, patients breathed 100% O(2) through a continuous positive airway pressure device (10 cm H(2)O) for 5 min. After induction of anesthesia, they were mechanically ventilated with PEEP (10 cm H(2)O) for another 5 min until tracheal intubation. In the control group, the sequence was the same but without any continuous positive airway pressure or PEEP. We measured apnea duration until Spo(2) reached 90% and we performed arterial blood gases analyses just before apnea and at 92% Spo(2). Nonhypoxic apnea duration was longer in the PEEP group compared with the control group (188 +/- 46 versus 127 +/- 43 s; P = 0.002). Pao(2) was higher before apnea in the PEEP group (P = 0.038). Application of positive airway pressure during induction of general anesthesia in morbidly obese patients increases nonhypoxic apnea duration by 50%.


Asunto(s)
Anestesia General , Apnea/etiología , Obesidad Mórbida/complicaciones , Respiración con Presión Positiva , Adolescente , Adulto , Análisis de los Gases de la Sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Estudios Prospectivos , Método Simple Ciego
11.
Eur Radiol ; 15(2): 238-46, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15565314

RESUMEN

The purpose of this study was to compare the diagnostic performance of axial and coronal views in multidetector CT enteroclysis (MDCTE). We retrospectively evaluated 48 patients with pathological correlation investigated by MDCTE for small bowel disorders. After nasojejunal administration of 2 l of 5% methylcellulose axial arterial and venous acquisition of MDCTE was followed by coronal reconstructions using equal slice thicknesses of 2.5 mm with 2 mm increments. Spatial resolution of both planes was evaluated by phantom. Three radiologists independently read axial and coronal images concerning 12 pathological features. The interobserver agreement and time of reading was calculated. Sensitivity and specificity resulted from comparison with histopathology (n=39) or follow-up (n=9). Phantom study revealed higher spatial resolution for axial than coronal views, whatever reconstruction interval was used. However, spatial frequency always remained high. Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and intraperitoneal fluid (IPF), showed better interobserver agreement on axial than coronal views (BWT: 0.61 vs. 0.44; BWE: 0.56 vs. 0.5; IPF:0.53 vs. 0.43). The Wilcoxon signed-rank test revealed significantly higher sensitivity for axial than coronal views (P=0.0453); the time of reading was significantly shorter for the latter (P=0.0146). The diagnostic value of axial slices is superior to coronal reconstructions despite the reduced data volume and display of the physiological course of bowel loops on the coronal plane.


Asunto(s)
Enfermedades Intestinales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Metilcelulosa , Persona de Mediana Edad , Fantasmas de Imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Estadísticas no Paramétricas
12.
Clin J Pain ; 21(1): 101-5, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15599137

RESUMEN

OBJECTIVE: The aim of the study was to assess whether coadministration of S(+) ketamine or ketorolac would enhance or prolong local analgesic effect of bupivacaine after inguinal hernia repair. DESIGN: Prospective double-blind randomized study evaluating pain intensity after surgery under general anesthesia. SETTING: Outpatient facilities of the University Hospital of Lausanne. PATIENT: Thirty-six ASA I-II outpatients scheduled for elective day-case inguinal herniorraphy. INTERVENTION: Analgesia strategy consisted of a wound infiltration and an inguinal field block either with 30 mL bupivacaine (0.5%) or with the same volume of a mixture of 27 mL bupivacaine (0.5%) + 3 mL S(+) ketamine (75 mg) or a 28 mL bupivacaine (0.5%) + 2 mL ketorolac (60 mg). Postoperative analgesic regimen was standardized. OUTCOME MEASURES: Pain intensity was assessed with a Visual Analog Scale, a verbal rating score, and by pressure algometry 2, 4, 6, 24, and 48 hours after surgery. RESULTS: The 3 groups of patients experienced the highest Visual Analog Scale pain score at 24 hours, which was different from those at 6 and 48 hours (P < 0.05). Apart from a significantly lower pain sensation (verbal rating score) in the ketorolac group at 24 and 48 hours and only at 48 hours with ketamine, there were no other differences in pain scores, pain pressure thresholds, or rescue analgesic consumption between groups throughout the 48-hour study period. CONCLUSION: The addition of S(+)-ketamine or ketorolac only minimally improves the analgesic effect of bupivacaine. This may be related to the tension-free hernia repair technique associated with low postoperative pain.


Asunto(s)
Anestésicos Disociativos/uso terapéutico , Anestésicos Locales , Antiinflamatorios no Esteroideos/uso terapéutico , Bupivacaína , Hernia Inguinal/cirugía , Ketamina/uso terapéutico , Ketorolaco/uso terapéutico , Bloqueo Nervioso , Dolor Postoperatorio/tratamiento farmacológico , Adulto , Anestésicos Disociativos/efectos adversos , Anestésicos Locales/efectos adversos , Antiinflamatorios no Esteroideos/efectos adversos , Bupivacaína/efectos adversos , Método Doble Ciego , Femenino , Humanos , Ketamina/efectos adversos , Ketorolaco/efectos adversos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Estudios Prospectivos
13.
Anesth Analg ; 98(5): 1491-5, table of contents, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15105237

RESUMEN

UNLABELLED: Atelectasis caused by general anesthesia is increased in morbidly obese patients. We have shown that application of positive end-expiratory pressure (PEEP) during the induction of anesthesia prevents atelectasis formation in nonobese patients. We therefore studied the efficacy of PEEP in morbidly obese patients to prevent atelectasis. Twenty-three adult morbidly obese patients (body mass index >35 kg/m(2)) were randomly assigned to one of two groups. In the PEEP group, patients breathed 100% oxygen (5 min) with a continuous positive airway pressure of 10 cm H(2)O and, after the induction, mechanical ventilation via a face mask with a PEEP of 10 cm H(2)O. In the control group, the same induction was applied but without continuous positive airway pressure or PEEP. Atelectasis, determined by computed tomography, and blood gas analysis were measured twice: before the induction and directly after intubation. After endotracheal intubation, patients of the control group showed an increase in the amount of atelectasis, which was much larger than in the PEEP group (10.4% +/- 4.8% in control group versus 1.7% +/- 1.3% in PEEP group; P < 0.001). After intubation with a fraction of inspired oxygen of 1.0, PaO(2) was significantly higher in the PEEP group compared with the control group (457 +/- 130 mm Hg versus 315 +/- 100 mm Hg, respectively; P = 0.035) We conclude that in morbidly obese patients, atelectasis formation is largely prevented by PEEP applied during the anesthetic induction and is associated with a better oxygenation. IMPLICATIONS: Application of positive end-expiratory pressure during induction of general anesthesia in morbidly obese patients prevents atelectasis formation and improves oxygenation. Therefore, this technique should be considered for anesthesia induction in morbidly obese patients.


Asunto(s)
Anestesia General/efectos adversos , Obesidad Mórbida/complicaciones , Atelectasia Pulmonar/prevención & control , Adulto , Anciano , Análisis de los Gases de la Sangre , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración con Presión Positiva , Atelectasia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X
14.
Anesth Analg ; 97(6): 1835-1839, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14633570

RESUMEN

UNLABELLED: General anesthesia promotes atelectasis formation, which is augmented by administration of large oxygen concentrations. We studied the efficacy of positive end-expiratory pressure (PEEP) application during the induction of general anesthesia (fraction of inspired oxygen [FIO(2)] 1.0) to prevent atelectasis. Sixteen adult patients were randomly assigned to one of two groups. Both groups breathed 100% O(2) for 5 min and, after a general anesthesia induction, mechanical ventilation via a face mask with a FIO(2) of 1.0 for another 5 min before endotracheal intubation. Patients in the first group (PEEP group) had continuous positive airway pressure (CPAP) (6 cm H(2)O) and mechanical ventilation via a face mask with a PEEP of 6 cm H(2)O. No CPAP or PEEP was applied in the control group. Atelectasis, determined by computed radiograph tomography, and analysis of blood gases were measured twice: before the beginning of anesthesia and directly after the intubation. There was no difference between groups before the anesthesia induction. After endotracheal intubation, patients in the control group showed an increase of the mean area of atelectasis from 0.8% +/- 0.9% to 4.1% +/- 2.0% (P = 0.0002), whereas the patients of the PEEP group showed no change (0.5% +/- 0.6% versus 0.4% +/- 0.7%). After the intubation with a FIO(2) of 1.0, PaO(2) was significantly higher in the PEEP group than in the control (591 +/- 54 mm Hg versus 457 +/- 99 mm Hg; P = 0.005). Atelectasis formation is prevented by application of PEEP during the anesthesia induction despite the use of large oxygen concentrations, resulting in improved oxygenation. IMPLICATIONS: Application of positive end-expiratory pressure during the induction of general anesthesia prevents atelectasis formation. Furthermore, it improves oxygenation and probably increases the margin of safety before intubation. Therefore, this technique should be considered for all anesthesia induction, at least in patients at risk of difficult airway management during the anesthesia induction.


Asunto(s)
Anestesia General/efectos adversos , Atelectasia Pulmonar/prevención & control , Adolescente , Adulto , Análisis de los Gases de la Sangre , Femenino , Humanos , Intubación Intratraqueal , Masculino , Respiración con Presión Positiva , Atelectasia Pulmonar/diagnóstico por imagen , Intercambio Gaseoso Pulmonar , Respiración Artificial , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
15.
Anesthesiology ; 98(6): 1315-27, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12766638

RESUMEN

BACKGROUND: Preconditioning by volatile anesthetics is a promising therapeutic strategy to render myocardial tissue resistant to perioperative ischemia. It was hypothesized that sevoflurane preconditioning would decrease postoperative release of brain natriuretic peptide, a biochemical marker for myocardial dysfunction. In addition, several variables associated with the protective effects of preconditioning were evaluated. METHODS: Seventy-two patients scheduled for coronary artery bypass graft surgery under cardioplegic arrest were randomly assigned to preconditioning during the first 10 min of complete cardiopulmonary bypass with either placebo (oxygen-air mixture only) or sevoflurane 4 vol% (2 minimum alveolar concentration). No other volatile anesthetics were administered at any time during the study. Treatment was strictly blinded to anesthesiologists, perfusionists, and surgeons. Biochemical markers of myocardial dysfunction and injury (brain natriuretic peptide, creatine kinase-MB activity, and cardiac troponin T), and renal dysfunction (cystatin C) were determined. Results of Holter electrocardiography were recorded perioperatively. Translocation of protein kinase C was assessed by immunohistochemical analysis of atrial samples. RESULTS: Sevoflurane preconditioning significantly decreased postoperative release of brain natriuretic peptide, a sensitive biochemical marker of myocardial contractile dysfunction. Pronounced protein kinase C delta and epsilon translocation was observed in sevoflurane-preconditioned myocardium. In addition, postoperative plasma cystatin C concentrations increased significantly less in sevoflurane-preconditioned patients. No differences between groups were found for perioperative ST-segment changes, arrhythmias, or creatine kinase-MB and cardiac troponin T release. CONCLUSIONS: Sevoflurane preconditioning preserves myocardial and renal function as assessed by biochemical markers in patients undergoing coronary artery bypass graft surgery under cardioplegic arrest. This study demonstrated for the first time translocation of protein kinase C isoforms delta and epsilon in human myocardium in response to sevoflurane.


Asunto(s)
Anestésicos por Inhalación/farmacología , Puente de Arteria Coronaria , Cardiopatías/metabolismo , Cardiopatías/prevención & control , Precondicionamiento Isquémico Miocárdico/métodos , Enfermedades Renales/metabolismo , Enfermedades Renales/prevención & control , Éteres Metílicos/farmacología , Adulto , Anciano , Anciano de 80 o más Años , Anestesia por Inhalación , Biomarcadores , Creatina Quinasa/sangre , Cistatina C , Cistatinas/sangre , Electrocardiografía Ambulatoria , Femenino , Cardiopatías/diagnóstico , Humanos , Inmunohistoquímica , Enfermedades Renales/diagnóstico , Masculino , Persona de Mediana Edad , Miocardio/patología , Pronóstico , Proteína Quinasa C/sangre , Sevoflurano , Resultado del Tratamiento , Troponina T/sangre
16.
Anesth Analg ; 95(6): 1777-81, table of contents, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12456458

RESUMEN

UNLABELLED: General anesthesia promotes pulmonary atelectasis, which can be eliminated by a vital capacity (VC) maneuver (inflation of the lungs to 40 cm H(2)O for 15 s). High-inspired oxygen concentration favors recurrence of atelectasis. Therefore, 100% oxygen before tracheal extubation may contribute to atelectasis. To evaluate whether the use of 100% oxygen before extubation increases the amount of postoperative atelectasis, we studied 30 adults scheduled for elective surgery of the extremities. Ten minutes before the presumed end of surgery, patients were randomly assigned to (a) a fraction of inspired oxygen (FIO(2)) = 1.0 (n = 10), (b) VC maneuver + FIO(2) = 1.0 (n = 10), or (c) VC maneuver + FIO(2) = 0.4 (n = 10). The amount of atelectasis was measured by computed tomography scan, and oxygenation was studied by arterial blood gas analysis. Data were analyzed by one-way analysis of variance with Bonferroni correction. Results are presented as mean +/- SD; P < 0.05 was considered significant. In the VC maneuver + FIO(2) = 0.4 group, postoperative atelectasis was smaller (2.6% +/- 1.1% of total lung surface, P < 0.05) than in the FIO(2) = 1.0 group (8.3% +/- 6.2%) and in the VC maneuver + FIO(2) = 1.0 group (6.8% +/- 3.4%). Oxygen 100% at the end of general anesthesia promotes postoperative atelectasis. A safety margin in terms of oxygenation during tracheal extubation is essential, and further studies should therefore evaluate whether atelectasis formation could be prevented despite the use of 100% oxygen. IMPLICATIONS: For safety reasons, it is common to ventilate patients with 100% oxygen before tracheal extubation. This study demonstrates that this practice favors postoperative atelectasis.


Asunto(s)
Intubación Intratraqueal , Oxígeno/efectos adversos , Complicaciones Posoperatorias/etiología , Atelectasia Pulmonar/etiología , Adolescente , Adulto , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Atelectasia Pulmonar/fisiopatología , Capacidad Vital
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...