Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38538841

RESUMEN

OBJECTIVES: To develop and test zone-specific prostate-specific antigen density (sPSAD) combined with PI-RADS to guide prostate biopsy decision strategies (BDS). METHODS: This retrospective study included consecutive patients, who underwent prostate MRI and biopsy (01/2012-10/2018). The whole gland and transition zone (TZ) were segmented at MRI using a retrained deep learning system (DLS; nnU-Net) to calculate PSAD and sPSAD, respectively. Additionally, sPSAD and PI-RADS were combined in a BDS, and diagnostic performances to detect Grade Group ≥ 2 (GG ≥ 2) prostate cancer were compared. Patient-based cancer detection using sPSAD was assessed by bootstrapping with 1000 repetitions and reported as area under the curve (AUC). Clinical utility of the BDS was tested in the hold-out test set using decision curve analysis. Statistics included nonparametric DeLong test for AUCs and Fisher-Yates test for remaining performance metrics. RESULTS: A total of 1604 patients aged 67 (interquartile range, 61-73) with 48% GG ≥ 2 prevalence (774/1604) were evaluated. By employing DLS-based prostate and TZ volumes (DICE coefficients of 0.89 (95% confidence interval, 0.80-0.97) and 0.84 (0.70-0.99)), GG ≥ 2 detection using PSAD was inferior to sPSAD (AUC, 0.71 (0.68-0.74)/0.73 (0.70-0.76); p < 0.001). Combining PI-RADS with sPSAD, GG ≥ 2 detection specificity doubled from 18% (10-20%) to 43% (30-44%; p < 0.001) with similar sensitivity (93% (89-96%)/97% (94-99%); p = 0.052), when biopsies were taken in PI-RADS 4-5 and 3 only if sPSAD was ≥ 0.42 ng/mL/cc as compared to all PI-RADS 3-5 cases. Additionally, using the sPSAD-based BDS, false positives were reduced by 25% (123 (104-142)/165 (146-185); p < 0.001). CONCLUSION: Using sPSAD to guide biopsy decisions in PI-RADS 3 lesions can reduce false positives at MRI while maintaining high sensitivity for GG ≥ 2 cancers. CLINICAL RELEVANCE STATEMENT: Transition zone-specific prostate-specific antigen density can improve the accuracy of prostate cancer detection compared to MRI assessments alone, by lowering false-positive cases without significantly missing men with ISUP GG ≥ 2 cancers. KEY POINTS: • Prostate biopsy decision strategies using PI-RADS at MRI are limited by a substantial proportion of false positives, not yielding grade group ≥ 2 prostate cancer. • PI-RADS combined with transition zone (TZ)-specific prostate-specific antigen density (PSAD) decreased the number of unproductive biopsies by 25% compared to PI-RADS only. • TZ-specific PSAD also improved the specificity of MRI-directed biopsies by 9% compared to the whole gland PSAD, while showing identical sensitivity.

2.
Eur J Radiol ; 166: 110964, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37453274

RESUMEN

PURPOSE: The ever-increasing volume of medical imaging data and interest in Big Data research brings challenges to data organization, categorization, and retrieval. Although the radiological value chain is almost entirely digital, data structuring has been widely performed pragmatically, but with insufficient naming and metadata standards for the stringent needs of image analysis. To enable automated data management independent of naming and metadata, this study focused on developing a convolutional neural network (CNN) that classifies medical images based solely on voxel data. METHOD: A 3D CNN (3D-ResNet18) was trained using a dataset of 31,602 prostate MRI volumes with 10 different sequence types of 1243 patients. A five-fold cross-validation approach with patient-based splits was chosen for training and testing. Training was repeated with a gradual reduction in training data assessing classification accuracies to determine the minimum training data required for sufficient performance. The trained model and developed method were tested on three external datasets. RESULTS: The model achieved an overall accuracy of 99.88 % ± 0.13 % in classifying typical prostate MRI sequence types. When being trained with approximately 10 % of the original cohort (112 patients), the CNN still achieved an accuracy of 97.43 % ± 2.10 %. In external testing the model achieved sensitivities of > 90 % for 10/15 tested sequence types. CONCLUSIONS: The herein developed CNN enabled automatic and reliable sequence identification in prostate MRI. Ultimately, such CNN models for voxel-based sequence identification could substantially enhance the management of medical imaging data, improve workflow efficiency and data quality, and allow for robust clinical AI workflows.


Asunto(s)
Metadatos , Próstata , Masculino , Humanos , Imagen por Resonancia Magnética , Redes Neurales de la Computación , Procesamiento de Imagen Asistido por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...