1.
J Neuroendovasc Ther ; 18(8): 213-218, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39166097

RESUMEN

Objective: The angiography systems A (A) and B (B), both incorporated at our hospital, are equipped with metal artifact reduction (MAR) applications. In clinical practice, it is crucial to understand the characteristics of MAR in both systems given that endovascular treatments are occasionally administered with both. In this study, we compared the artifact reduction effects of MAR on equipment A and B and clarified the differences between the two systems. Methods: An artifact evaluation phantom was created using a cylindrical water phantom and an iodine contrast medium. The phantom was imaged, MAR processing was performed on the obtained images, and an isotropic quantitative evaluation of artifacts was performed by extreme value statistical analysis using the Gumbel distribution. Results: The MAR reduction effects were approximately 45% and 40% for equipment A and B at concentrations of 8300 and 6000, respectively. The MAR reduction effect in both devices exhibited different trends depending on the concentration. Conclusion: In clinical procedures that make use of absorbents in medium concentrations of approximately 3000-5000, such as n-butyl-2-cyanoacrylate and Onyx, it is necessary to understand the MAR characteristics of both devices and consider the use of alternative devices as an option.

2.
Ann Nucl Med ; 38(8): 659-665, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38787504

RESUMEN

OBJECTIVE: Radioiodine (I-131) therapy for hyperthyroidism is a well-established and safe treatment option. This study aimed to investigate the relationship between the computed tomography (CT) value and the function and volume of the thyroid gland by identifying the factors that induce changes in the CT value of patients with hyperthyroidism. METHODS: This retrospective study evaluated 38 patients with Graves' disease and 10 patients with Plummer disease. To obtain the mean CT value and volume of the thyroid gland, the entire thyroid gland was set as the region of interest. A test dose of 3.7 MBq I-131 was administered before initiating I-131 therapy, and the radioiodine uptake (RIU) rate was assessed after 3, 24, 96, and 168 h. An approximate curve was plotted based on the RIU values obtained, and the effective half-life (EHL) was calculated. The correlation between the mean CT value and the volume of the thyroid gland, 24-h RIU, EHL, and the free triiodothyronine (FT3), free thyroxine (FT4), thyroid-stimulating hormone (TSH), and TSH receptor antibody (TRAb) levels was evaluated. RESULTS: The CT value exhibited a significant positive correlation with EHL in patients with Graves' disease (r = 0.62, p < 0.0001) as well as patients with Plummer disease (r = 0.74, p < 0.05). However, it did not display any correlation with the remaining parameters. CONCLUSION: The CT value is significantly correlated with EHL, suggesting that it reflects thyroid function and is mainly related to the factors associated with iodine discharge.


Asunto(s)
Hipertiroidismo , Glándula Tiroides , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Femenino , Masculino , Glándula Tiroides/diagnóstico por imagen , Persona de Mediana Edad , Adulto , Hipertiroidismo/diagnóstico por imagen , Hipertiroidismo/radioterapia , Anciano , Enfermedad de Graves/diagnóstico por imagen , Enfermedad de Graves/radioterapia , Enfermedad de Graves/fisiopatología , Pruebas de Función de la Tiroides , Radioisótopos de Yodo , Tamaño de los Órganos , Adulto Joven
3.
Phys Med ; 119: 103298, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38309102

RESUMEN

BACKGROUND: The dead-time loss reportedly degrades the accuracy of dosimetry using a gamma camera for targeted radionuclide therapy with Lu-177; therefore, the dead-time loss needs to be corrected. However, the correction is challenging. In this study, we propose a novel and simple method to shorten the apparent dead time rather than correcting it through experiments and Monte Carlo simulations. METHODS: An energy window of 208 keV ± 10 % is generally used for the imaging of Lu-177. Lower-energy gamma photons and X-rays of Lu-177 do not contribute to image formation but lead to dead-time losses. In our proposed method, a thin lead sheet was used to shield gamma photons and X-rays with energies lower than 208 keV, while detecting 208 keV gamma photons that penetrated the thin sheet. We measured and simulated the energy spectra and count rate characteristics of a clinical gamma camera system using a cylindrical phantom filled with a Lu-177 solution. Lead sheets of 1.0- and 0.5-mm thicknesses were used as thin shields, and the dead-time losses in tumour imaging with consumed Lu-177 were simulated. RESULTS: The apparent dead times with lead sheets of 1.0- and 0.5-mm thicknesses and without a lead sheet were 1.7, 1.9, and 5.8 µs for an energy window of 208 keV ± 10 %, respectively. The dead-time losses could be reduced from 10 % to 1.3 % using the 1.0-mm thick lead sheet in the simulated imaging of tumour. CONCLUSION: Our method is promising in clinical situations and studies on Lu-177 dosimetry for tumours.


Asunto(s)
Neoplasias , Radioisótopos , Humanos , Radioisótopos/uso terapéutico , Cámaras gamma , Lutecio/uso terapéutico , Fantasmas de Imagen , Método de Montecarlo
4.
Clin Neurol Neurosurg ; 236: 108110, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38171051

RESUMEN

OBJECTIVE: This study aimed to analyze whether the development of donor vessels after combined revascularization surgery for moyamoya disease (MMD) is related to cerebral blood flow (CBF) changes. METHODS: We retrospectively reviewed the charts of 11 adult (12 hemispheres) and 13 pediatric (19 hemispheres) patients who underwent combined revascularization in our department. The total vessel cross-sectional area (TVA) was the sum of the cross-sectional areas of the superficial temporal, middle meningeal, and deep temporal arteries imaged using time-of-flight magnetic resonance angiography. The ipsilateral relative CBF (RCBF) on the brain surface in the craniotomy area was calculated by single-photon emission computed tomography. ΔTVA and ΔRCBF were defined as the preoperative and postoperative ratios of TVA and RCBF, and their correlations were analyzed in adult and pediatric patients. RESULTS: The TVA and RCBF showed a significant increase after surgery, regardless of the age group. However, there was no significant correlation between ΔTVA and ΔRCBF in either the adult or pediatric groups. While the adult group exhibited significantly higher ΔRCBF values compared to the pediatric group (p < 0.01, r = -0.44), the ΔTVA values were higher in the pediatric group compared to the adult group (p = 0.06). CONCLUSIONS: In the chronic phase after combined revascularization surgery for MMD, the development of measurable TVA of donor vessels does not necessarily correlate with an increase in CBF around the craniotomy area.


Asunto(s)
Revascularización Cerebral , Enfermedad de Moyamoya , Adulto , Humanos , Niño , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/cirugía , Estudios Retrospectivos , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Circulación Cerebrovascular/fisiología
5.
Eur J Nucl Med Mol Imaging ; 51(4): 1060-1069, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38008728

RESUMEN

PURPOSE: To examine whether adherence to a low-iodine diet (LID) enhances the therapeutic efficacy of radioiodine therapy (RAI) in Graves' hyperthyroidism (GH) in iodine-rich areas. METHODS: We retrospectively evaluated 185 patients with GH from Aichi (n = 114) and Hokkaido (n = 71) Prefectures. Patients aged ≥ 18 years with GH who underwent RAI between December 2012 and March 2022 were divided into subgroups based on pretreatment with anti-thyroid drug (ATD) or potassium iodide (KI). Patients were followed up with LID from 18 days (group A) or 7 days (group H) before RAI to 3 days after RAI. The dose of radioactive iodine 131 (131I) was adjusted to deliver > 100 Gy to the thyroid. The associations between urinary iodine concentration on UIC2 vs. 24hRU and UIC2 vs. the 1-year RAI success rate (SR) were investigated. RESULTS: Compared with UIC1, UIC2 was significantly decreased in all subgroups (P < 0.01). An inverse correlation between UIC2 and 24hRU was observed in the four groups; however, the difference was insignificant. The SR in groups A and H was 85% and 89%, respectively. Univariate analysis revealed no association between UIC2 and SR in each group. Additionally, stratification of the 185 patients into quartiles using UIC2 yielded no significant differences in SR (p = 0.79). CONCLUSIONS: LID sufficiently reduced UIC in patients undergoing RAI. Although a lower UIC2 may increase 24hRU, it did not increase the success of RAI. The benefit of LID in enhancing the efficacy of RAI in GH treatment remains uncertain.


Asunto(s)
Enfermedad de Graves , Hipertiroidismo , Yodo , Neoplasias de la Tiroides , Humanos , Radioisótopos de Yodo/efectos adversos , Yodo/uso terapéutico , Estudios Retrospectivos , Neoplasias de la Tiroides/tratamiento farmacológico , Enfermedad de Graves/radioterapia , Enfermedad de Graves/tratamiento farmacológico , Dieta , Potasio , Resultado del Tratamiento
6.
JACC Cardiovasc Imaging ; 17(1): 45-58, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37452820

RESUMEN

BACKGROUND: Fluorodeoxyglucose positron emission tomography (18F-FDG-PET) can noninvasively assess active inflammatory myocardium in patients with cardiac sarcoidosis (CS). Prednisolone (PSL) is the initial drug of choice for active CS; however, its efficacy has not been prospectively evaluated. Moreover, there are no alternative systematic treatment strategies. OBJECTIVES: The goal of this study was to evaluate the efficacy of methotrexate (MTX) in patients refractory to PSL assessed by using cardiac metabolic activity (CMA) in 18F-FDG-PET. METHODS: A total of 59 patients with active CS were prospectively enrolled. CMA (standardized uptake value × accumulation area) was used as an indicator of active inflammation, and a 6-month regimen of PSL therapy was introduced, followed by a second FDG scan. Poor responders to PSL therapy (CMA reduction rate <70%) and patients with recurrent CS (CMA reduction rate ≥70% after initial PSL therapy but CMA recurred after an additional 6 months of therapy) were randomly assigned to the MTX or repeat PSL (re-PSL) therapy groups for another 6 months. RESULTS: Fifty-six patients completed the initial 6-month PSL therapy regimen. Median CMA reduced from 203.3 to 1.0 (P < 0.001), and 47 patients were allocated to the response group, 9 to the poor response group, and 2 to the recurrent group. Accordingly, 11 patients were randomly assigned to the MTX (n = 5) or re-PSL (n = 6) groups. After 6 months, neither group showed a significant reduction in CMA values. MTX was comparable to re-PSL in reducing CMA. CONCLUSIONS: The 6-month regimen of PSL was a potent therapeutic tool for active CS. When MTX was added to low-dose PSL in patients refractory to the initial PSL therapy, there was no significant difference compared with re-PSL. Further studies are needed to evaluate the therapeutic potential of MTX for active CS, including how MTX works when it is administered in higher doses or for longer periods.


Asunto(s)
Cardiomiopatías , Miocarditis , Sarcoidosis , Humanos , Fluorodesoxiglucosa F18 , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/tratamiento farmacológico , Radiofármacos , Valor Predictivo de las Pruebas , Miocardio/metabolismo , Sarcoidosis/diagnóstico por imagen , Sarcoidosis/tratamiento farmacológico , Sarcoidosis/metabolismo , Tomografía de Emisión de Positrones/métodos , Terapia de Inmunosupresión
7.
Ann Nucl Med ; 37(9): 494-503, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37243882

RESUMEN

OBJECTIVE: Tau positron emission tomography (PET) imaging is a recently developed non-invasive tool that can detect the density and extension of tau neurofibrillary tangles. Tau PET tracers have been validated to harmonize and accelerate their development and implementation in clinical practice. Whereas standard protocols including injected dose, uptake time, and duration have been determined for tau PET tracers, reconstruction parameters have not been standardized. The present study conducted phantom experiments based on tau pathology to standardize quantitative tau PET imaging parameters and optimize reconstruction conditions of PET scanners at four Japanese sites according to the results of phantom experiments. METHODS: The activity of 4.0 and 2.0 kBq/mL for Hoffman 3D brain and cylindrical phantoms, respectively, was estimated from published studies of brain activity using [18F]flortaucipir, [18F]THK5351, and [18F]MK6240. We developed an original tau-specific volume of interest template for the brain based on pathophysiological tau distribution in the brain defined as Braak stages. We acquired brain and cylindrical phantom images using four PET scanners. Iteration numbers were determined as contrast and recover coefficients (RCs) in gray (GM) and white (WM) matter, and the magnitude of the Gaussian filter was determined from image noise. RESULTS: Contrast and RC converged at ≥ 4 iterations, the error rates of RC for GM and WM were < 15% and 1%, respectively, and noise was < 10% in Gaussian filters of 2-4 mm in images acquired using the four scanners. Optimizing the reconstruction conditions for phantom tau PET images acquired by each scanner improved contrast and image noise. CONCLUSIONS: The phantom activity was comprehensive for first- and second-generation tau PET tracers. The mid-range activity that we determined could be applied to later tau PET tracers. We propose an analytical tau-specific VOI template based on tau pathophysiological changes in patients with AD to standardize tau PET imaging. Phantom images reconstructed under the optimized conditions for tau PET imaging achieved excellent image quality and quantitative accuracy.


Asunto(s)
Encéfalo , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Encéfalo/diagnóstico por imagen , Fantasmas de Imagen , Estándares de Referencia
8.
Ann Nucl Med ; 37(7): 410-418, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37160863

RESUMEN

OBJECTIVES: Standardised uptake value ratio (SUVR) is usually obtained by dividing the SUV of the region of interest (ROI) by that of the cerebellar cortex. Cerebellar cortex is not a valid reference in cases where amyloid ß deposition or lesions are present. Only few studies have evaluated the use of other regions as references. We compared the validity of the pons and corpus callosum as reference regions for the quantitative evaluation of brain positron emission tomography (PET) using 11C-PiB compared to the cerebellar cortex. METHODS: We retrospectively evaluated data from 86 subjects with or without Alzheimer's disease (AD). All subjects underwent magnetic resonance imaging, PET imaging, and cognitive function testing. For the quantitative analysis, three-dimensional ROIs were automatically placed, and SUV and SUVR were obtained. We compared these values between AD and healthy control (HC) groups. RESULTS: SUVR data obtained using the pons and corpus callosum as reference regions strongly correlated with that using the cerebellar cortex. The sensitivity and specificity were high when either the pons or corpus callosum was used as the reference region. However, the SUV values of the corpus callosum were different between AD and HC (p < 0.01). CONCLUSIONS: Our data suggest that the pons and corpus callosum might be valid reference regions.


Asunto(s)
Enfermedad de Alzheimer , Humanos , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Péptidos beta-Amiloides/metabolismo , Cuerpo Calloso/metabolismo , Cuerpo Calloso/patología , Estudios Retrospectivos , Tomografía de Emisión de Positrones/métodos , Encéfalo/metabolismo , Puente/diagnóstico por imagen , Puente/metabolismo , Puente/patología , Compuestos de Anilina
9.
Radiat Prot Dosimetry ; 198(20): 1585-1597, 2022 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-36321327

RESUMEN

The International Commission on Radiological Protection (ICRP) 118th recommendation significantly reduced the threshold dose for cataract development from 8 to 0.5 Gy. Equivalent dose limits for the crystalline lenses of radiation workers are being reviewed for individual countries. Interventional radiology (IR) procedures are less invasive than surgery and have become widespread; however, there are concerns about exposure not only to patients but also to staff, including operators. Therefore, in this study, we used a human phantom to measure the near-lens dose of the operators (cardiologists, neurosurgeons and radiologists) and estimated the operator's lens dose for every major procedure in each clinical department; this was found to vary. Owing to the different imaging and fluoroscopy conditions of each department, and the varying ratio of fluoroscopy to radiography, it is necessary to measure the lens dose for each condition, as in this study. In addition, this study explains the differences between the protective effect of various safety equipment and the appropriate use of protective plates; it can contribute to the reduction of lens doses for operators.

10.
J Appl Clin Med Phys ; 23(7): e13626, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35536775

RESUMEN

PURPOSE: Accurate tracer accumulation evaluation is difficult owing to the partial volume effect (PVE). We proposed a novel semi-quantitative approach for measuring the accumulation amount by examining the approximate image. Using a striatal phantom, we verified the validity of a newly proposed method to accurately evaluate the tracer accumulations in the caudate and putamen separately. Moreover, we compared the proposed method with the conventional methods. METHODS: The left and right caudate/putamen regions and the whole brain region as background were identified in computed tomography (CT) images obtained by single-photon emission computed tomography (SPECT)/CT and acquired the positional information of each region. SPECT-like images were generated by assigning assumed accumulation amounts to each region. The SPECT-like image, approximated to the actual measured SPECT image, was examined by changing the assumed accumulation amounts assigned to each region. When the generated SPECT-like image most approximated the actual measured SPECT image, the accumulation amounts assumed were determined as the accumulation amounts in each region. We evaluated the correlation between the count density calculated by the proposed method and the actual count density of the 123 I solution filled in the phantom. Conventional methods (CT-guide method, geometric transfer matrix [GTM] method, region-based voxel-wise [RBV] method, and Southampton method) were also evaluated. The significance of differences between the correlation coefficients of various methods (except the Southampton method) was evaluated. RESULTS: The correlation coefficients between the actual count density and the SPECT count densities were 0.997, 0.973, 0.951, 0.950, and 0.996 for the proposed method, CT-guide method, GTM method, RBV method, and Southampton method, respectively. The correlation of the proposed method was significantly higher than those of the other methods. CONCLUSIONS: The proposed method could calculate accurate accumulation amounts in the caudate and putamen separately, considering the PVE.


Asunto(s)
Proteínas de Transporte de Dopamina a través de la Membrana Plasmática , Tomografía Computarizada de Emisión de Fotón Único , Encéfalo , Proteínas de Transporte de Dopamina a través de la Membrana Plasmática/metabolismo , Humanos , Fantasmas de Imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos
11.
Neurosurg Rev ; 45(3): 2471-2480, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35319072

RESUMEN

The purpose of this study was to examine the effects of combined revascularization for ischaemic-onset moyamoya disease (MMD) on cerebral haemodynamics by comparing cerebral blood flow (CBF) during the postoperative chronic phase with preoperative CBF. A retrospective cohort of 24 MMD patients (representing 31 surgeries) who received single photon emission computed tomography (SPECT) before and more than 6 months after surgery was investigated. The CBF value of each vascular territory was extracted from SPECT data, and the value relative to the ipsilateral cerebellar value (relative CBF, or RCBF) was calculated. The correlation between the revascularization effect and the proportional change in RCBF before and after surgery (calculated as post-RCBF/pre-RCBF ("post/pre-RCBF")) was analysed. Furthermore, the relationships between changes in neurological symptoms and post/pre-RCBF were investigated. Preoperative and postoperative mean RCBF values were 0.92 ± 0.15 and 0.96 ± 0.13 (p = 0.619) in the anterior cerebral artery territory, 0.99 ± 0.17 and 1.01 ± 0.17 (p = 0.598) in the middle cerebral artery territory and 1.15 ± 0.22 and 1.14 ± 0.19 (p = 0.062) in the posterior cerebral artery territory, respectively. No significant correlation was found between the revascularization score and post/pre-RCBF. The revascularization score and post/pre-RCBF were not significant predictors of worsening neurological symptoms postoperatively. No significant change in RCBF was observed in any vascular territory in the chronic phase after revascularization. Combined revascularization may assist in the redirection of blood flow from the internal to the external carotid system and contribute to CBF maintenance.


Asunto(s)
Revascularización Cerebral , Enfermedad de Moyamoya , Revascularización Cerebral/métodos , Circulación Cerebrovascular/fisiología , Humanos , Enfermedad de Moyamoya/cirugía , Estudios Retrospectivos , Tomografía Computarizada de Emisión de Fotón Único
12.
J Appl Clin Med Phys ; 22(4): 15-25, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33779118

RESUMEN

PURPOSE: This study examined the variation in the thyroid volume determined by the ellipsoid approximation method due to differences in the measured length or area of the cross-sectional plane of CT images. METHODS: Forty-five patients with Graves' disease were included in this retrospective study. We designated the three-dimensional thyroid volumes extracted manually (VCT ) as the reference data and calculated five approximate volumes for comparison: (a) the mean volume of 8100 different thyroid volumes depending on the diameter of the cross-sectional plane at the midpoint of the major axis, (Vellipsoid,mean ); (b) the volume using the maximum diameter and its orthogonal diameter, (Vellipsoid,maxlength ); (c) the maximum (Vellipsoid,maxvolume ); (d) minimum (Vellipsoid,minvolume ) of the 8100 thyroid volumes; and (e) the volume determined with an equivalent circle diameter, (Vellipsoid,Heywood ). RESULTS: Thyroid volumes obtained via the ellipsoid approximation method varied depending on the diameter of the cross-sectional plane and included a mean error of approximately 20%, while the concordance correlation coefficient (CCC) differed for each approximate volume. Among these volumes, Vellipsoid,mean and Vellipsoid,Heywood were in good agreement with VCT , according to single regression analyses and the resultant CCC values, with mean errors of 0.1% and 10.4%, respectively. CONCLUSION: While Vellipsoid,Heywood approximated thyroid volumes with vastly reduced errors, we recommend utilizing three-dimensional thyroid volumetry if measurement accuracy is required.


Asunto(s)
Glándula Tiroides , Tomografía Computarizada por Rayos X , Estudios Transversales , Humanos , Estudios Retrospectivos , Glándula Tiroides/diagnóstico por imagen
13.
EJNMMI Phys ; 7(1): 6, 2020 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-31993828

RESUMEN

BACKGROUND: Before radioiodine therapy for Graves' disease, the estimated thyroid-absorbed dose is calculated based on various clinical parameters. However, the actual accumulation of iodine in the thyroid during radioiodine therapy is not determined. We validated the feasibility of post-therapeutic image-based thyroid dosimetry through quantitative single-photon emission computed tomography (SPECT) imaging and thyroid biokinetics and expanding the Medical Internal Radiation Dose Committee's (MIRD) voxel dosimetry guidelines. METHODS: Forty-three patients with Graves' disease who underwent radioiodine therapy were chosen as subjects for this retrospective analysis. We acquired patients' SPECT images 24 h after oral administration. SPECT images were quantified using system volume sensitivity to calculate time-integrated activity coefficients on a voxel basis. Absorbed dose was obtained by convolving MIRD guideline voxel S values with time-integrated activity coefficients. To determine accuracy, we compared the results obtained using the post-therapeutic image-based absorbed-dose method (D̅image,PVC) with absorbed doses calculated using the method described by the European Association of Nuclear Medicine (pre-therapeutic method; DEANM). RESULTS: Using image-based dosimetry as post-therapeutic dosimetry, we visualized the local accumulation and absorbed dose distribution of iodine in the thyroid. Furthermore, we determined a strong correlation (Pearson's correlation coefficient = 0.89) between both dosimetries, using the regression equation: D̅image,PVC = 0.94 × DEANM + 1.35. CONCLUSION: Post-therapeutic image-based doses absorbed in the thyroid resembled those of pre-therapeutic EANM method-based absorbed doses. Additionally, the post-therapeutic image-based method had the advantage of visualizing thyroid iodine distribution, thus determining local dose distributions at the time of treatment. From these points, we propose that post-therapeutic image-based dosimetry could provide an alternative to standard pre-therapeutic dosimetry to evaluate dose response.

14.
Sci Rep ; 8(1): 10976, 2018 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-30030499

RESUMEN

Ra-223 has recently been introduced to alpha radionuclide therapy. According to the decay scheme of Ra-223, an inert gas, Rn-219 is released from patients during alpha radionuclide therapy and its daughter radionuclides may accumulate around the patient. However, the concentration of these radon daughters during alpha radionuclide therapy was not obvious. Here, we first detected the radon daughters of Rn-219 around patients during alpha radionuclide therapy. While the Ra-223-administered patients were in a room for ~1.5 hours, the radon daughter concentration increased to 4 to 5 times higher than without the patients. When the patients were in the room, the energy spectra of the alpha particles in the air showed the peak of the radon daughter of Rn-219, Bi-211 (6.6 MeV), which was different from that without the patients. We conclude that the daughter radionuclides of Rn-219 are accumulated around the patient, and the concentration was higher than that of the natural radon daughters. However, the increase in levels of alpha emitters, while detectable, is lower than the daily variations and thus is likely not a source of concern for radiation exposure.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Partículas alfa/efectos adversos , Radioterapia/efectos adversos , Radio (Elemento)/uso terapéutico , Partículas alfa/uso terapéutico , Humanos , Exposición a la Radiación , Radio (Elemento)/análisis , Hijas del Radón/análisis
15.
Ann Nucl Med ; 32(5): 348-362, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29667143

RESUMEN

OBJECTIVE: Recent many studies have shown that whole body "diffusion-weighted imaging with background body signal suppression" (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and 18F-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma. METHODS: Subjects in this retrospective study comprised 13 consecutive pediatric patients with neuroblastoma (7 males, 6 females; mean age, 2.9 ± 2.0 years old) who underwent both 18F-FDG PET/CT and whole-body DWIBS. All patients were diagnosed as neuroblastoma on the basis of pathological findings. Eight regions of lymph nodes and 17 segments of skeletons in all patients were evaluated. The images of 123I-MIBG scintigraphy/SPECT-CT, bone scintigraphy/SPECT, and CT were used to confirm the presence of lymph node and bone metastases. Two radiologists trained in nuclear medicine evaluated independently the uptake of lesions in 18F-FDG PET/CT and the signal-intensity of lesions in whole-body DWIBS visually. Interobserver difference was overcome through discussion to reach a consensus. The sensitivities, specificities, and overall accuracies of 18F-FDG PET/CT and whole-body DWIBS were compared using McNemer's test. Positive predictive values (PPVs) and negative predictive values (NPVs) of both modalities were compared using Fisher's exact test. RESULTS: The total numbers of lymph node regions and bone segments which were confirmed to have metastasis in the total 13 patients were 19 and 75, respectively. The sensitivity, specificity, overall accuracy, PPV, and NPV of 18F-FDG PET/CT for detecting lymph node metastasis from pediatric neuroblastoma were 100, 98.7, 98.9, 95.0, and 100%, respectively, and those for detecting bone metastasis were 90.7, 73.1, 80.3, 70.1, and 91.9%, respectively. In contrast, the sensitivity, specificity, overall accuracy, PPV, and NPV of whole-body DWIBS for detecting bone metastasis from pediatric neuroblastoma were 94.7, 24.0, 53.0, 46.4 and 86.7%, respectively, whereas those for detecting lymph node metastasis were 94.7, 85.3, 87.2, 62.1, and 98.5%, respectively. The low specificity, overall accuracy, and PPV of whole-body DWIBS for detecting bone metastasis were due to a high incidence of false-positive findings (82/108, 75.9%). The specificity, overall accuracy, and PPV of whole-body DWIBS for detecting lymph node metastasis were also significantly lower than those of 18F-FDG PET/CT for detecting lymph node metastasis, although the difference between these 2 modalities was less than that for detecting bone metastasis. CONCLUSION: The specificity, overall accuracy, and PPV of whole-body DWIBS are significantly lower than those of 18F-FDG PET/CT because of a high incidence of false-positive findings particularly for detecting bone metastasis, whereas whole-body DWIBS shows a similar level of sensitivities for detecting lymph node and bone metastases to those of 18F-FDG PET/CT. DWIBS should be carefully used for cancer staging in children because of its high incidence of false-positive findings in skeletons.


Asunto(s)
Neoplasias Óseas/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Metástasis Linfática/diagnóstico por imagen , Neuroblastoma/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos , 3-Yodobencilguanidina , Neoplasias Óseas/secundario , Huesos/diagnóstico por imagen , Preescolar , Reacciones Falso Positivas , Femenino , Fluorodesoxiglucosa F18 , Humanos , Lactante , Ganglios Linfáticos/diagnóstico por imagen , Masculino , Imagen Multimodal/métodos , Neuroblastoma/patología , Variaciones Dependientes del Observador , Radiofármacos , Estudios Retrospectivos , Sensibilidad y Especificidad , Medronato de Tecnecio Tc 99m
16.
Br J Radiol ; 87(1034): 20130444, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24297809

RESUMEN

OBJECTIVE: We compared the efficacies of ¹8F-fluoride positron emission tomography (¹8F-fluoride PET)/CT, ¹8F-fludeoxyglucose PET (¹8F-FDG PET)/CT, and 99mTc bone scintigraphy [planar and single photon emission CT (SPECT)] for the detection of bone metastases in patients with differentiated thyroid carcinoma (DTC). METHODS: We examined 11 patients (8 females and 3 males; mean age 6 standard deviation, 61.968.7 years) with DTC who had been suspected of having bone metastases after total thyroidectomy and were hospitalized to be given ¹³¹I therapy. Bone metastases were verified either when positive findings were obtained on both ¹³¹I scintigraphy and CT or when MRI findings were positive if MRI was performed. RESULTS: Metastases were confirmed in 24 (13.6%) of 176 bone segments in 9 (81.8%) of the 11 patients. The sensitivities of ¹8F-fluoride PET/CT and 99mTc bone scintigraphy (SPECT) were significantly higher than those of ¹8F-FDG PET/CT and 99mTc bone scintigraphy (planar) (p,0.05). The accuracies of ¹8F-fluoride PET/CT and mTc bone scintigraphy (SPECT) were significantly higher than that of 99mTc bone scintigraphy (planar) (p,0.05). CONCLUSION: The sensitivity and accuracy of ¹8F-fluoride PET/CT for the detection of bone metastases of DTC are significantly higher than those of 99mTc bone scintigraphy (planar). However, the sensitivity and accuracy of 99mTc bone scintigraphy (planar) are improved near to those of ¹8F-fluoride PET/CT when SPECT is added to a planar scan. The sensitivity of ¹8F-FDG PET/CT is significantly lower than that of 18F-fluoride PET/CT or 99mTc bone scintigraphy (SPECT).


Asunto(s)
Adenocarcinoma Folicular/diagnóstico , Adenocarcinoma Folicular/secundario , Neoplasias Óseas/diagnóstico , Neoplasias Óseas/secundario , Carcinoma Papilar/diagnóstico , Carcinoma Papilar/secundario , Neoplasias de la Tiroides , Adenocarcinoma Folicular/cirugía , Anciano , Huesos/diagnóstico por imagen , Carcinoma Papilar/cirugía , Diagnóstico Diferencial , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Proyectos Piloto , Tomografía de Emisión de Positrones/métodos , Sensibilidad y Especificidad , Neoplasias de la Tiroides/cirugía , Tiroidectomía , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X/métodos
17.
Int J Comput Assist Radiol Surg ; 8(4): 621-33, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23263885

RESUMEN

PURPOSE: Liquid crystal display (LCD) of mammograms provides soft-copy results that differ in conventional and phase contrast mammography (PCM). PCM potentially offers the highest quality of sharpness and graininess, an edge emphasis effect on the object, and the highest image resolution. However, when the image is displayed on an LCD, the resolution depends on the pixel pitch and the PCM image data must be diminished. We investigated the observed effect on spatial resolution and contrast when conventional or phase contrast mammograms are viewed on an LCD. METHODS: Using the tissue-equivalent phantom (Model 1011A), a conventional mammogram and a magnification radiography image were obtained with a PCM system. This phantom contains simulated fibers, microcalcifications, and masses. The PCM image was reduced 1/1.75 to render it consistent with life size mammography using the nearest neighbor, bilinear, and bicubic interpolation methods. The images were displayed on a five million (5M)-pixel LCD with 100 % magnification. Ten mammography technicians observed the reduction images displayed on LCDs and reported their results. RESULTS: In the detectability of the microcalcifications, there was no significant difference between conventional mammograms and reduced PCM images. Regarding fibers and masses, detectability using reduced images was higher than those of conventional images. The detectability using images reduced by the nearest-neighbor method was lower than those of images reduced by two other interpolation methods. Bilinear interpolation was affected by the smoothing effect, while CNR was increased. In addition, since the noise of PCM image was reduced by an air gap effect, high detectability of key image features was found. CONCLUSIONS: Soft-copy display of phase-contrast mammograms is feasible with LCDs, while detectability of fibers and masses was best with bilinear interpolation and use of an air gap.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Presentación de Datos , Mamografía/métodos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Femenino , Humanos , Cristales Líquidos
18.
Clin Nucl Med ; 37(3): 258-63, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22310252

RESUMEN

OBJECTIVE: The conventional methods for the estimation of regional cerebral blood flow (rCBF) using ¹²³I-labeled N-isopropyl-p-iodoamphetamine (¹²³I IMP) autoradiography (ARG) require continuous or 1-point arterial blood sampling. Patients who need rCBF quantification benefit from the avoidance of arterial puncture. In this study, we attempted to develop a method without any blood sampling to estimate ¹²³I IMP activity in the arterial blood sample at 10 minutes after injection of ¹²³I IMP (Ca10) for the purpose of rCBF quantification. For the evaluation of validity of this method, the mean of rCBFs in various regions of the brain (mean CBF) calculated by ¹²³I IMP ARG method using the estimated Ca10 was compared with that calculated using the Ca10 directly measured with the actual arterial blood sample. Both groups of the mean CBF values were also compared with those measured by O-15 H2O PET ARG method. METHODS: I-123 IMP ARG study was applied to 23 patients, and O-15 H2O PET ARG was applied to 20 patients of them. Dynamic images of the lungs, time series of static images of the brain, and brain SPECT images were acquired after injection of ¹²³I IMP. Arterial blood sampling was done 10 minutes after injection of ¹²³I IMP. Multiple regression analysis was used to estimate Ca10 using 5 parameters from the lung washout counts, time series of brain static counts, and brain SPECT average counts as the explanatory variables and the Ca10 directly measured with the actual arterial blood sample as the objective variable, and the regression equation was calculated. RESULTS: The regression equation was calculated by multiple regression analysis as follows: Estimated Ca10 = (2.09 × 10⁻² · LW3) - (2.29 × 10⁻4 · Cb5) - (9.87 × 10⁻³ · Cbpre-SPECT) + (1.06 · CbSPECTav) + (1.03 × 10⁻² · Cbpost-SPECT) + 165 (counts/s/g), where LW3: lung washout count at 3 minutes after injection, Cb5: brain count at 5 minutes, Cb pre-SPECT: brain count before SPECT, Cb SPECT av: average brain count during SPECT, and Cb post-SPECT: brain count after SPECT. The estimated Ca10 values closely correlated with the directly measured Ca10 values (r = 0.907, P < 0.01). The mean CBF values (mL/min/100 g) calculated by ¹²³I IMP ARG method using the estimated Ca10 also closely correlated with those calculated using the directly measured Ca10 (r = 0.818, P < 0.01). The mean CBF values calculated by the ¹²³I IMP ARG method using either the directly measured or the estimated Ca10 significantly correlated (r = 0.698 and 0.590, respectively; P < 0.01) with those measured by O-15 H2O PET ARG method. CONCLUSIONS: The ¹²³I IMP arterial blood activity can be estimated reliably without any blood sampling using the ¹²³I IMP acquisition data from the lungs and brain. This method can serve for a convenient and noninvasive rCBF quantification technique instead of the conventional methods requiring arterial blood sampling.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Trastornos Cerebrovasculares/diagnóstico por imagen , Radioisótopos de Yodo , Yofetamina , Pulmón/irrigación sanguínea , Pulmón/diagnóstico por imagen , Tomografía de Emisión de Positrones , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Autorradiografía/métodos , Trastornos Cerebrovasculares/fisiopatología , Distribución de Chi-Cuadrado , Femenino , Humanos , Radioisótopos de Yodo/administración & dosificación , Radioisótopos de Yodo/farmacocinética , Yofetamina/administración & dosificación , Yofetamina/farmacocinética , Masculino , Persona de Mediana Edad , Radioisótopos de Oxígeno/administración & dosificación , Radioisótopos de Oxígeno/farmacocinética , Flujo Sanguíneo Regional , Análisis de Regresión