Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Prosthodont Res ; 67(4): 619-625, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36967125

RESUMEN

PURPOSE: This study aimed to clarify the effect of occlusal force on appropriate optical interocclusal registration in clinical practice, considering periodontal ligament and jawbone deformation. METHODS: Forty participants with natural, healthy dentition were enrolled (19 men and 21 women; mean age, 27.7 ± 2.0 years). A TRIOS3 intraoral scanner was used to scan the right lateral first premolar to the second molar areas of the upper and lower jaws. During scanning for interocclusal registration, participants were instructed to "bite normally," "bite lightly," and "bite strongly" to obtain data for the three occlusal patterns. The standard triangulated language (STL) data for each occlusion condition were superimposed using the appropriate software, following which the tooth displacement was calculated. The conventional method was also used to record the occlusal contact area for a silicone model using a dental contact analyzer. RESULTS: Tooth displacement was significantly lower for the strong-bite condition than for the weak-bite condition (0.018 mm vs. 0.028 mm, P<0.05). As the occlusal force increased, the occlusal contact area also increased, and significant differences were observed among the different occlusal conditions (P<0.05). CONCLUSIONS: Occlusal contact area changed depending on the bite force when using the silicone impression or optical intraoral scanning methods. Moreover, using optical impression methods in "strong bite force" may reduce the deviation and allow for stable interocclusal registration.


Asunto(s)
Fuerza de la Mordida , Oclusión Dental , Masculino , Humanos , Femenino , Adulto , Diente Premolar , Diente Molar , Siliconas
2.
Int J Implant Dent ; 8(1): 18, 2022 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-35416598

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the accuracy of intraoral scanners by comparing the trueness and precision of several types of scanners in measuring the distance between the ball abutments on pairs of multiple implants. METHODS: Seven implants were placed on a fully edentulous upper jaw model. After ball abutments were attached to the implants on the master model, the three-dimensional (3D) shape of the model was evaluated using a computer numerical control 3D coordinate-measuring machine. Subsequently, the 3D shape-related data of the model were obtained using two types of intraoral scanners (3M True Definition Scanner [TDS] and 3Shape Trios3 [TR3]) and two types of laboratory scanners (KaVo ARCTICA Auto Scan [KA] and Identica Hybrid [IH]). Using the obtained 3D shape-related data, the trueness and precision in measuring the distance between the balls within seven pairs of ball abutments were compared among the scanners using 3D analysis software. RESULTS: Intraoral scanners produced significantly greater errors in trueness and precision than laboratory scanners in measuring the distances between the ball abutments in all the dental regions. Between the intraoral scanners, powder-requiring TDS produced significantly lower errors at inflection points than powder-free TR3. CONCLUSIONS: These results indicate that an optical impression technique using an intraoral scanner is suitable for dental implant treatment in patients with a few missing teeth.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Diseño Asistido por Computadora , Técnica de Impresión Dental , Humanos , Imagenología Tridimensional , Modelos Dentales
3.
J Oral Sci ; 63(4): 301-305, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34408111

RESUMEN

The recent literature on maxillary implant overdenture (IOD) was reviewed in order to clarify its predictability and establish treatment guidelines. Electronic searches were performed using PubMed, and articles about maxillary IOD written after 1990 were reviewed, focusing on the following items: I. implant survival rate, II. maxillary IOD survival rate, III. number of implants, IV. attachment type, V. follow-up period, VI. implant system, and VII. opposing dentition. The review revealed an implant survival rate of 61-100% and an overdenture survival rate of 72.4-100%. The attachments used included bars, balls, locators, and telescope crowns. The minimum and maximum observation periods were 12 months and 120 months, respectively, and the number of implants used for supporting IOD ranged from 2 to 8. At present, there is no strong evidence to indicate that maxillary IOD is clearly superior for all the items examined. However, the existing data indicate that maxillary IOD has almost the same therapeutic effect as fixed implant superstructures, and is a treatment option that can be actively adopted for patients in whom fixed superstructures cannot be applied for various reasons.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Retención de Dentadura , Prótesis de Recubrimiento , Humanos , Maxilar
4.
J Oral Sci ; 63(3): 212-216, 2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34078769

RESUMEN

This narrative review aims to provide an overview of recent studies and case reports on three-dimensional (3D) printing, and to verify the applicability of 3D printers in the field of dental prostheses. This review was performed by conducting a search of PubMed. The clinical application of fabricating a prosthesis made with cobalt-chromium is considered possible depending on the material and hardware of the 3D printer. However, it is currently difficult to assess the clinical use of 3D-printed zirconia crowns. Further research is required, such as verification of materials used, margin morphology, and hardware. Clinically acceptable results have been reported for patterns using 3D printers. Interim restorations made using a 3D printer have been reported with good results that are considered clinically usable. Dentures made with 3D printers need further verification in terms of strength and deformation. Custom trays made with 3D printers are clinically useful, however, issues remain with design time and effort. Although several studies have reported the usefulness of 3D printers, further verification is required since 3D printers are still considered new technology.


Asunto(s)
Impresión Tridimensional , Prostodoncia , Coronas
5.
J Oral Sci ; 63(3): 267-269, 2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34135265

RESUMEN

PURPOSE: The purpose of this study was to examine morphological changes in the superstructure of implants in relation to the degree of attrition of the implant superstructure and its antagonists. METHODS: Thirty-three patients participated. The implant superstructures of the first molar and its antagonists were scanned with an intraoral scanner every 3 months. The amount of attrition was calculated in relation to the various materials used for the superstructure, and differences were analyzed statistically (P < 0.05). RESULTS: Attrition of the implant superstructure was 110 ± 30 µm for monolithic zirconia and 105 ± 27 µm for resin-veneered metal after 12 months. No statistically significant difference was found between the two groups. In contrast, attrition of the antagonists was 75 ± 25 µm for zirconia and 105 ± 20 µm for resin-veneered metal after 12 months. A statistically significant difference in the attrition levels between the two groups was observed after 9 and 12 months. CONCLUSION: During the 12-month observation period, there was no difference in superstructure attrition between zirconia and resin-veneered metal. Attrition of the antagonists was higher for hybrid composite resin-veneered metal than for zirconia, suggesting that surface roughness affected the degree of attrition.


Asunto(s)
Resinas Compuestas , Implantes Dentales , Porcelana Dental , Coronas con Frente Estético , Humanos , Ensayo de Materiales , Circonio
6.
J Prosthodont Res ; 61(4): 450-459, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28216020

RESUMEN

PURPOSE: We examined the accuracy, including trueness and precision, of the intraoral scanners comparing with laboratory scanner to reveal the error level of intraoral scanners. METHODS: Measurements were performed using a computer numerical control coordinate measuring machine (CNCCMM) of the reference models as a control. Subsequently, intraoral scanners and a laboratory scanner were used for measurements of the reference trueness and precision of the distance were evaluated by image analyzing software. RESULTS: With regard to reference model, there was a significant difference between in the trueness measured by C.O.S. (COS) and that measured by the other scanners. The trueness measured by the second-generation 3M™ true definition scanner (TDS2) and third-generation 3M™ true definition scanner (TDS3) was bigger than the one by TRIOS (TR) and KaVo (KA). With regard to reference model "B," error of the trueness measured by COS was significantly bigger, compared with the one measured by the other scanners. However, error range of intraoral scanners, except for COS, was considerably small and it should be covered with cement space. CONCLUSIONS: The results of this study indicated that an optical impression method with an intraoral scanner could be applied to the implant therapy for multiple teeth missing.


Asunto(s)
Diseño Asistido por Computadora , Pilares Dentales , Diseño de Implante Dental-Pilar/métodos , Técnica de Impresión Dental/instrumentación , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...