Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
J Cardiol Cases ; 27(3): 132-135, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36910034

RESUMEN

The endovascular treatment using a drug-coated balloon (DCB) reduces restenosis and target vessel re-vascularization rate in patients with peripheral artery disease such as claudication and chronic limb-threatening ischemia (CLTI). However, its safety and efficacy in patients with post-below-knee amputation remain unknown. We had a patient with CLTI and a history of below-knee amputation, who suffered a no-flow phenomenon following DCB angioplasty that required above-knee amputation. DCB angioplasty might not be appropriate for those with severe CLTI and histories of amputation. Learning objective: The present report describes the risk of endovascular treatment using a drug-coated balloon for chronic limb-threatening ischemia patients with a below-knee amputated limb.

2.
Eur Heart J Case Rep ; 6(9): ytac370, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36147932

RESUMEN

Background: Secondary mitral regurgitation (SMR) is a major comorbidity in patients with heart failure with reduced ejection fraction (HFrEF). Transcatheter edge-to-edge repair (TEER) using the MitraClip™ system is a promising tool for selected patients with SMR and HFrEF. Durable success using this system in patients who have advanced heart failure and unsuitable anatomy remains a clinical challenge. Case summary: Three patients aged 67-72 years with HFrEF on inotropic support successfully underwent Impella®-assisted TEER at our centre. Following the procedure, two patients were able to be weaned off inotropic support and were discharged, while one patient expired during the index hospitalization. Discussion: Impella®-assisted TEER may be a feasible strategy for patients with SMR and HFrEF with unstable haemodynamics particularly when cardiac replacement therapy is not applicable.

3.
Medicina (Kaunas) ; 58(2)2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-35208635

RESUMEN

Cancer therapeutics-related cardiac dysfunction is currently of great concern as one of the pivotal therapeutic targets of onco-cardiology. Only a few studies have reported the occurrence of heart failure following the administration of osimertinib, a third-generation epidermal growth factor receptor (EGFR)-tyrosine kinase inhibitor for EGFR mutation-positive advanced non-small cell lung cancer. We report on a 74-year-old woman with osimertinib-induced advanced heart failure with reduced ejection fraction, which was treated by the temporal termination of osimertinib and neurohormonal blocker therapy, as well as heart rate modulation therapy using ivabradine. Despite osimertinib-induced heart failure being relatively rare, aggressive neurohormonal blocker therapy using ivabradine if applicable, as well as the temporal termination of osimertinib, might be a promising therapeutic strategy.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Insuficiencia Cardíaca , Neoplasias Pulmonares , Acrilamidas/efectos adversos , Anciano , Compuestos de Anilina , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Femenino , Insuficiencia Cardíaca/inducido químicamente , Insuficiencia Cardíaca/tratamiento farmacológico , Humanos , Neoplasias Pulmonares/tratamiento farmacológico , Mutación , Inhibidores de Proteínas Quinasas/efectos adversos
4.
Int Heart J ; 63(1): 73-76, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35095079

RESUMEN

Remote dielectric sensing (ReDS) is a recently introduced non-invasive electromagnetic-based device used to quantify lung fluid levels. Nevertheless, its inter-rater and intra-rater reliability remain uncertain. In 10 healthy volunteers, ReDS values were measured three times successively by the officially trained expert examiner to validate intra-rater reliability. Similar measures were performed by a total of three examiners to validate inter-rater reliability. Intra-class correlation (ICC) was applied to validate each reliability. Ten healthy volunteers [median 34 (32, 40) years old, 10 men, body mass index 23.0 (21.2, 23.9) ] were included. Median ReDS value was 28% (25%, 31%). For the intra-rater reliability, ICC (1, 1) and ICC (1, 3) were 0.966 and 0.988, respectively (P < 0.001). For the inter-rater reliability, ICC (2, 1) and ICC (2, 3) were 0.683 and 0.866, respectively (P < 0.001). Given almost perfect intra-rater reliability, an examiner does not need to repeat ReDS measurement. Given substantial inter-rater reliability, ReDS measurements had better be measured by multiple examiners if possible.


Asunto(s)
Agua Pulmonar Extravascular , Pulmón , Tecnología de Sensores Remotos/instrumentación , Adulto , Estudios de Cohortes , Humanos , Masculino , Variaciones Dependientes del Observador , Prueba de Estudio Conceptual , Valores de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA