RESUMEN
BACKGROUND: Cryoglobulins are cold-precipitable immunoglobulins that may cause systemic vasculitis including cryoglobulinaemic glomerulonephritis (CGN). Type 1 cryoglobulins consist of isolated monoclonal immunoglobulin (mIg), whereas mixed cryoglobulins are typically immune complexes comprising either monoclonal (type 2) or polyclonal (type 3) Ig with rheumatoid activity against polyclonal IgG. Only CGN related to type 1 cryoglobulins has been clearly associated with monoclonal gammopathy of undetermined significance (MGUS) using the conventional serum-, urine- or tissue-based methods of paraprotein detection. CASE PRESENTATION: We present four patients with noninfectious mixed (type 2 or 3) CGN and MGUS. Two patients had type 2 cryoglobulinaemia, one had type 3 cryoglobulinaemia, and one lacked definitive typing of the serum cryoprecipitate. The serum monoclonal band was IgM-κ in all four cases. Treatments included corticosteroids, cyclophosphamide, plasma exchange, and rituximab. At median 3.5 years' follow-up, no patient had developed a haematological malignancy or advanced chronic kidney disease. Other potential causes of mixed cryoglobulinaemia were also present in our cohort, notably primary Sjögren's syndrome in three cases. CONCLUSION: Our study raises questions regarding the current designation of type 2 CGN as a monoclonal gammopathy of renal significance, and the role of clonally directed therapies for noninfectious mixed CGN outside the setting of haematological malignancy.
Asunto(s)
Crioglobulinemia/complicaciones , Crioglobulinas , Glomerulonefritis/complicaciones , Inmunoglobulina M/sangre , Cadenas kappa de Inmunoglobulina/sangre , Gammopatía Monoclonal de Relevancia Indeterminada/complicaciones , Síndrome de Sjögren/complicaciones , Anciano , Crioglobulinemia/sangre , Crioglobulinemia/terapia , Ciclofosfamida/uso terapéutico , Femenino , Glomerulonefritis/terapia , Glucocorticoides/uso terapéutico , Humanos , Factores Inmunológicos/uso terapéutico , Inmunosupresores/uso terapéutico , Masculino , Persona de Mediana Edad , Gammopatía Monoclonal de Relevancia Indeterminada/sangre , Gammopatía Monoclonal de Relevancia Indeterminada/terapia , Intercambio Plasmático , Rituximab/uso terapéuticoRESUMEN
Background Electrophoretic methods to detect, characterize and quantify M-proteins play an important role in the management of patients with monoclonal gammopathies (MGs). Significant uncertainty in the quantification and limit of detection (LOD) is documented when M-proteins are <10 g/L. Using spiked sera, we aimed to assess the variability in intact M-protein quantification and LOD across 16 laboratories. Methods Sera with normal, hypo- or hyper-gammaglobulinemia were spiked with daratumumab or elotuzumab, with concentrations from 0.125 to 10 g/L (n = 62) along with a beta-migrating sample (n = 9). Laboratories blindly analyzed samples according to their serum protein electrophoresis (SPEP)/isotyping standard operating procedures. LOD and intra-laboratory percent coefficient of variation (%CV) were calculated and further specified with regard to the method (gel/capillary electrophoresis [CZE]), gating strategy (perpendicular drop [PD]/tangent skimming [TS]), isotyping (immunofixation/immunosubtraction [ISUB]) and manufacturer (Helena/Sebia). Results All M-proteins ≥1 g/L were detected by SPEP. With isotyping the LOD was moderately more sensitive than with SPEP. The intensity of polyclonal background had the biggest negative impact on LOD. Independent of the method used, the intra-laboratory imprecision of M-protein quantification was small (mean CV = 5.0%). Low M-protein concentration and high polyclonal background had the strongest negative impact on intra-laboratory precision. All laboratories were able to follow trend of M-protein concentrations down to 1 g/L. Conclusions In this study, we describe a large variation in the reported LOD for both SPEP and isotyping; overall LOD is most affected by the polyclonal immunoglobulin background. Satisfactory intra-laboratory precision was demonstrated. This indicates that the quantification of small M-proteins to monitor patients over time is appropriate, when subsequent testing is performed within the same laboratory.
Asunto(s)
Electroforesis de las Proteínas Sanguíneas/métodos , Laboratorios de Hospital/normas , Proteínas de Mieloma/análisis , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales Humanizados/química , Estudios de Seguimiento , Humanos , Isotipos de Inmunoglobulinas/química , Límite de Detección , Paraproteinemias/diagnósticoRESUMEN
Background Serum protein electrophoresis (SPEP) is used to quantify the serum monoclonal component or M-protein, for diagnosis and monitoring of monoclonal gammopathies. Significant imprecision and inaccuracy pose challenges in reporting small M-proteins. Using therapeutic monoclonal antibody-spiked sera and a pooled beta-migrating M-protein, we aimed to assess SPEP limitations and variability across 16 laboratories in three continents. Methods Sera with normal, hypo- or hypergammaglobulinemia were spiked with daratumumab, Dara (cathodal migrating), or elotuzumab, Elo (central-gamma migrating), with concentrations from 0.125 to 10 g/L (n = 62) along with a beta-migrating sample (n = 9). Provided with total protein (reverse biuret, Siemens), laboratories blindly analyzed samples according to their SPEP and immunofixation (IFE) or immunosubtraction (ISUB) standard operating procedures. Sixteen laboratories reported the perpendicular drop (PD) method of gating the M-protein, while 10 used tangent skimming (TS). A mean percent recovery range of 80%-120% was set as acceptable. The inter-laboratory %CV was calculated. Results Gamma globulin background, migration pattern and concentration all affect the precision and accuracy of quantifying M-proteins by SPEP. As the background increases, imprecision increases and accuracy decreases leading to overestimation of M-protein quantitation especially evident in hypergamma samples, and more prominent with PD. Cathodal migrating M-proteins were associated with less imprecision and higher accuracy compared to central-gamma migrating M-proteins, which is attributed to the increased gamma background contribution in M-proteins migrating in the middle of the gamma fraction. There is greater imprecision and loss of accuracy at lower M-protein concentrations. Conclusions This study suggests that quantifying exceedingly low concentrations of M-proteins, although possible, may not yield adequate accuracy and precision between laboratories.
Asunto(s)
Electroforesis de las Proteínas Sanguíneas/métodos , Laboratorios de Hospital/normas , Proteínas de Mieloma/análisis , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales Humanizados/química , Humanos , Isotipos de Inmunoglobulinas/química , Límite de Detección , Paraproteinemias/diagnóstico , Reproducibilidad de los ResultadosRESUMEN
A genome-wide ethyl-N-nitrosourea (ENU) mutagenesis screen in mice was performed to identify novel regulators of erythropoiesis. Here, we describe a mouse line, RBC16, which harbours a dominantly inherited mutation in the Cpox gene, responsible for production of the haem biosynthesis enzyme, coproporphyrinogen III oxidase (CPOX). A premature stop codon in place of a tryptophan at amino acid 373 results in reduced mRNA expression and diminished protein levels, yielding a microcytic red blood cell phenotype in heterozygous mice. Urinary and faecal porphyrins in female RBC16 heterozygotes were significantly elevated compared with that of wild-type littermates, particularly coproporphyrinogen III, whereas males were biochemically normal. Attempts to induce acute porphyric crises were made using fasting and phenobarbital treatment on females. While fasting had no biochemical effect on RBC16 mice, phenobarbital caused significant elevation of faecal coproporphyrinogen III in heterozygous mice. This is the first known investigation of a mutagenesis mouse model with genetic and biochemical parallels to hereditary coproporphyria.
Asunto(s)
Coproporfiria Hereditaria/genética , Etilnitrosourea/química , Mutagénesis/genética , Anemia Hipocrómica/sangre , Anemia Hipocrómica/genética , Animales , Secuencia de Bases , Vías Biosintéticas/genética , Coproporfiria Hereditaria/sangre , Coproporfirinógeno Oxidasa/genética , Modelos Animales de Enfermedad , Ayuno/sangre , Heces/química , Femenino , Hemo/biosíntesis , Masculino , Ratones Mutantes , Mutación/genética , Fenobarbital/farmacología , Fenotipo , EmbarazoRESUMEN
Twenty participants undergoing elective cataract surgery received 1% voriconazole eye drops (1 drop per eye) either 20, 40, 60, or 80 min before surgery. Median voriconazole concentrations of 1.9 to 3.2 mg/liter in aqueous humor samples were attained over the first 80 min, which were higher than in vitro MIC90 values for typical fungi that cause keratitis.
Asunto(s)
Humor Acuoso/efectos de los fármacos , Soluciones Oftálmicas/farmacocinética , Voriconazol/farmacocinética , Adulto , Anciano , Anciano de 80 o más Años , Antifúngicos/farmacocinética , Extracción de Catarata , Femenino , Humanos , Masculino , Persona de Mediana EdadRESUMEN
BACKGROUND: Despite significant interindividual variability in prednisolone pharmacokinetics and potentially serious consequences with inadequate or excessive exposure, monitoring of prednisolone levels is not employed to guide therapy. As ultrahigh-performance liquid chromatography-tandem mass spectrometry methods can now measure the active free fraction of prednisolone, this study aimed to evaluate the performance of 15 published limited sampling strategies (LSSs) for predicting free prednisolone exposure in adult kidney transplant recipients and to examine the relationship between free/total prednisolone exposure and plasma glucose. METHODS: The study was performed in 11 subjects without diabetes 3-4 weeks postkidney transplantation. Area under the concentration time curve profiles of total and free prednisolone from 0 to 12 hours postdose (AUC0â12) were determined and compared with predicted AUC0â12 values calculated from published LSSs. Venous glucose was measured concurrently with the 13 sampling time points. RESULTS: The mean (±SD) age of subjects was 52 ± 12 years, 5 were men and the median (interquartile range) daily prednisolone dose was 20.0 mg (20.0-22.5). Interindividual variation in dose-adjusted free and total prednisolone exposure was 1.9- and 3.2-fold, respectively. All 15 free prednisolone LSSs exhibited good correlation (r ≥ 0.83), with bias and imprecision less than 15%. An LSS incorporating 1.25- and 3-hour samples had the highest predictive power (r = 0.97, bias 1.2%, imprecision 5.6%). Free prednisolone AUC0â12 correlated with peak glucose levels (r = 0.65, P = 0.037), as did predicted AUC0â12 from 14/15 LSSs. CONCLUSIONS: Biologically active free prednisolone exposure can be accurately predicted postkidney transplantation by LSSs incorporating 2-point concentration sampling. Peak plasma glucose concentration correlated well with prednisolone exposure.
Asunto(s)
Monitoreo de Drogas/métodos , Glucocorticoides/farmacocinética , Trasplante de Riñón , Prednisolona/farmacocinética , Adolescente , Adulto , Anciano , Área Bajo la Curva , Glucemia/efectos de los fármacos , Recolección de Muestras de Sangre , Cromatografía Líquida de Alta Presión/métodos , Femenino , Glucocorticoides/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Prednisolona/administración & dosificación , Manejo de Especímenes , Espectrometría de Masas en Tándem/métodos , Factores de Tiempo , Adulto JovenRESUMEN
Ten participants attending elective anterior segment eye surgery received 0.5% caspofungin eye drops either 1 drop hourly for 4 h or 1 drop an hour before surgery. The eye drops were generally well tolerated. In the absence of inflammation or corneal abrasion, topical caspofungin does not achieve clinically relevant concentrations.
Asunto(s)
Humor Acuoso/metabolismo , Equinocandinas/farmacocinética , Soluciones Oftálmicas/administración & dosificación , Soluciones Oftálmicas/farmacocinética , Anciano , Anciano de 80 o más Años , Caspofungina , Equinocandinas/administración & dosificación , Femenino , Humanos , Lipopéptidos , Masculino , Persona de Mediana EdadRESUMEN
The measurement of drug concentrations, for clinical purposes, occurs in many diagnostic laboratories throughout Australia and New Zealand. However, the provision of a comprehensive therapeutic drug monitoring (TDM) service requires the additional elements of pre- and postanalytical advice to ensure that concentrations reported are meaningful, interpretable, and clinically applicable to the individual patient. The aim of this project was to assess the status of TDM services in Australia and New Zealand. A range of professions involved in key aspects of TDM was surveyed by questionnaire in late 2007. Information gathered included: the list of drugs assayed; analytical methods used; interpretation services offered; interpretative methods used; and further monitoring advice provided. Fifty-seven responses were received, of which 42% were from hospitals (public and/or private); 11% a hospital (public and/or private) and pathology provider; and 47% a pathology provider only (public and/or private). Results showed that TDM is applied to a large number of different drugs. Poorly performing assay methods were used in some cases, even when published guidelines recommended alternative practices. Although there was a wide array of assays available, the evidence suggested a need for better selection of assay methods. In addition, only limited advice and/or interpretation of results was offered. Of concern, less than 50% of those providing advice on aminoglycoside dosing in adults used pharmacokinetic tools with six of 37 (16.2%) respondents using Bayesian pharmacokinetic tools, the method recommended in the Australian Therapeutic Guidelines: Antibiotic. In conclusion, the survey highlighted deficiencies in the provision of TDM services, in particular assay method selection and both quality and quantity of postanalytical advice. A range of recommendations, some of which may have international implications, are discussed. There is a need to include measures of impact on clinical decision-making when assessing assay methodologies. Best practice guidelines and professional standards of practice in TDM are needed, supported by an active program of professional development to ensure the benefits of TDM are realized. This will require significant partnerships between the various professions involved.
Asunto(s)
Benchmarking , Monitoreo de Drogas/normas , Servicio de Farmacia en Hospital/normas , Guías de Práctica Clínica como Asunto/normas , Australia , Monitoreo de Drogas/métodos , Nueva Zelanda , Encuestas y CuestionariosRESUMEN
A rapid, precise, and sensitive liquid chromatography/mass spectrometry (LC/MS) method to quantify the caspofungin concentration in human aqueous humor was developed and validated. Sample preparation involved simple dilution of aqueous humor samples with acetonitrile. Azithromycin was the internal standard. Good linearity over 10 to 5,000 ng/ml was observed. The lower limit of quantification was 10 ng/ml. The intra- and interday accuracies (percent bias) were within 11%, while the intra- and interday precisions were within 6%.
Asunto(s)
Humor Acuoso/química , Cromatografía Liquida/métodos , Equinocandinas/análisis , Equinocandinas/metabolismo , Espectrometría de Masas/métodos , Azitromicina/análisis , Azitromicina/metabolismo , Caspofungina , Humanos , Lipopéptidos , Estándares de Referencia , Reproducibilidad de los ResultadosRESUMEN
PURPOSE: Although there have been reports describing the use of 1% voriconazole eye drops in the treatment of fungal infections, little is known about the penetration of voriconazole eye drops into the vitreous humour. The aim of this study was to elucidate if topical application of 1% voriconazole eye drops could reach therapeutic levels in the vitreous humour. METHODS: A prospective, open-label trial involving 10 participants selected from patients scheduled to undergo elective, posterior segment surgery. Participants received 1% voriconazole solution, preserved with 0.01% benzalkonium chloride, hourly for four doses or four times a day for 3 days. Vitreous humour was obtained at the start of surgery and analysed using a validated high-performance liquid chromatography assay. RESULTS: The minimum and maximum voriconazole concentration after hourly dosing (n = 5) was 0.1 and 1.1 microg/mL, respectively, whereas the median was 0.3 microg/mL. Samples were taken between 0.8 and 5.4 h after the last dose, with the median at 1.2 h. Almost all voriconazole concentrations from the four times a day group (n = 5) were below the limit of quantification. CONCLUSIONS: One per cent voriconazole eye drops are able to penetrate into human vitreous humour. Adequate concentration for treatment of sensitive Candida species can be achieved upon hourly administration.
Asunto(s)
Antifúngicos/farmacocinética , Pirimidinas/farmacocinética , Triazoles/farmacocinética , Cuerpo Vítreo/metabolismo , Anciano , Disponibilidad Biológica , Cromatografía Líquida de Alta Presión , Femenino , Humanos , Masculino , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Soluciones Oftálmicas/farmacocinética , Estudios Prospectivos , VoriconazolRESUMEN
Therapeutic drug monitoring of cyclosporin (CsA) has been established as part of the routine clinical treatment of patients following organ transplantation for more than 20 years, and based on contemporary knowledge, many consensus guidelines have been published to assist clinics and laboratories attain optimal strategies for patient care. This article addresses the newer directions in CsA monitoring, with particular reference to the Australasian situation that has evolved since the 1993 Australasian guideline. These changes have included the introduction of alternative assay methodologies, changed CsA formulation from Sandimmun to Neoral throughout Australasia, and alternatives to trough concentration (C0) monitoring, especially 2-hour concentration (C2) monitoring and associated validated dilution protocols to accurately quantitate the higher whole blood CsA concentrations. The revision was prepared following a recent survey of all Australasian CsA-monitoring laboratories where discordant practices were evident.