1.
Biomed Opt Express ; 15(6): 3993-4009, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38867778

RESUMEN

We demonstrate large-area robotically assisted optical coherence tomography (LARA-OCT), utilizing a seven-degree-of-freedom robotic arm in conjunction with a 3.3 MHz swept-source OCT to raster scan samples of arbitrary shape. By combining multiple fields of view (FOV), LARA-OCT can probe a much larger area than conventional OCT. Also, nonplanar and curved surfaces like skin on arms and legs can be probed. The lenses in the LARA-OCT scanner with their normal FOV can have fewer aberrations and less complex optics compared to a single wide field design. This may be especially critical for high resolution scans. We directly use our fast MHz-OCT for tracking and stitching, making additional machine vision systems like cameras, positioning, tracking or navigation devices obsolete. This also eliminates the need for complex coordinate system registration between OCT and the machine vision system. We implemented a real time probe-to-surface control that maintains the probe alignment orthogonal to the sample by only using surface information from the OCT images. We present OCT data sets with volume sizes of 140 × 170 × 20 mm3, captured in 2.5 minutes.

2.
Opt Express ; 32(4): 5809-5825, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38439298

RESUMEN

Circumferential scanning in endoscopic imaging is crucial across various disciplines, and optical coherence tomography (OCT) is often the preferred choice due to its high-speed, high-resolution, and micron-scale imaging capabilities. Moreover, real-time and high-speed 3D endoscopy is a pivotal technology for medical screening and precise surgical guidance, among other applications. However, challenges such as image jitter and non-uniform rotational distortion (NURD) are persistent obstacles that hinder real-time visualization during high-speed OCT procedures. To address this issue, we developed an innovative, low-cost endoscope that employs a brushless DC motor for scanning, and a sensorless technique for triggering and synchronizing OCT imaging with the scanning motor. This sensorless approach uses the motor's electrical feedback (back electromotive force, BEMF) as a virtual Hall sensor to initiate OCT image acquisition and synchronize it with a Fourier Domain Mode-Locked (FDML)-based Megahertz OCT system. Notably, the implementation of BEMF-triggered OCT has led to a substantial reduction in image jitter and NURD (<4 mrad), thereby opening up a new window for real-time visualization capabilities. This approach suggests potential benefits across various applications, aiming to provide a more accurate, deployable, and cost-effective solution. Subsequent studies can explore the adaptability of this system to specific clinical scenarios and its performance under practical endoscopic conditions.

3.
Sci Rep ; 14(1): 4672, 2024 02 26.
Artículo en Inglés | MEDLINE | ID: mdl-38409328

RESUMEN

Colonoscopy and endoscopic ultrasound play pivotal roles in the assessment of rectal diseases, especially rectal cancer and inflammatory bowel diseases. Optical coherence tomography (OCT) offers a superior depth resolution, which is a critical factor for individualizing the therapeutic concept and evaluating the therapy response. We developed two distinct rectoscope prototypes, which were integrated into a 1300 nm MHz-OCT system constructed at our facility. The rapid rotation of the distal scanning probe at 40,000 revolutions per minute facilitates a 667 Hz OCT frame rate, enabling real-time endoscopic imaging of large areas. The performance of these OCT-rectoscopes was assessed in an ex vivo porcine colon and a post mortem human in-situ colon. The OCT-rectoscope consistently distinguished various layers of the intestinal wall, identified gut-associated lymphatic tissue, and visualized a rectal polyp during the imaging procedure with 3D-reconstruction in real time. Subsequent histological examination confirmed these findings. The body donor was preserved using an ethanol-glycerol-lysoformin-based technique for true-to-life tissue consistency. We could demonstrate that the novel MHZ-OCT-rectoscope effectively discriminates rectal wall layers and crucial tissue characteristics in a post mortem human colon in-situ. This real-time-3D-OCT holds promise as a valuable future diagnostic tool for assessing disease state and therapy response on-site in rectal diseases.


Asunto(s)
Enfermedades del Recto , Neoplasias del Recto , Animales , Porcinos , Humanos , Tomografía de Coherencia Óptica/métodos , Proctoscopía , Endoscopía Gastrointestinal , Recto
4.
Biomed Opt Express ; 13(2): 713-727, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35284187

RESUMEN

We present continuous three-dimensional spectral zooming in live 4D-OCT using a home-built FDML based OCT system with 3.28 MHz A-scan rate. Improved coherence characteristics of the FDML laser allow for imaging ranges up to 10 cm. For the axial spectral zoom feature, we switch between high resolution and long imaging range by adjusting the sweep range of our laser. We present a new imaging setup allowing for synchronized adjustments of the imaging range and lateral field of view during live OCT imaging. For this, a novel inline recalibration algorithm was implemented that enables numerical k-linearization of the raw OCT fringes for every frame instead of every volume. This is realized by acquiring recalibration data within the dead time of the raster scan at the turning points of the fast axis scanner. We demonstrate in vivo OCT images of fingers and hands at different resolution modes and show real three-dimensional zooming during live 4D-OCT. A three-dimensional spectral zooming feature for live 4D-OCT is expected to be a useful tool for a wide range of biomedical, scientific and research applications, especially in OCT guided surgery.

5.
Biomed Opt Express ; 12(5): 2604-2616, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34123491

RESUMEN

In highly dispersion compensated Fourier domain mode locked (FDML) lasers, an ultra-low noise operation can only be achieved by extremely precise and stable matching of the filter tuning period and light circulation time in the cavity. We present a robust and high precision closed-loop control algorithm and an actively cavity length controlled FDML laser. The cavity length control achieves a stability of ∼0.18 mHz at a sweep repetition rate of ∼418 kHz which corresponds to a ratio of 4×10-10. Furthermore, we prove that the rapid change of the cavity length has no negative impact on the quality of optical coherence tomography using the FDML laser as light source.

6.
Biomed Opt Express ; 11(11): 6799-6811, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33282524

RESUMEN

In order to realize adjustable A-scan rates of fast optical coherence tomography (OCT) systems, we investigate averaging of OCT image data acquired with a MHz-OCT system based on a Fourier Domain Mode Locked (FDML) laser. Increased system sensitivity and image quality can be achieved with the same system at the cost of lower imaging speed. Effectively, the A-scan rate can be reduced in software by a freely selectable factor. We demonstrate a detailed technical layout of the strategies necessary to achieve efficient coherent averaging. Since there are many new challenges specific to coherent averaging in swept source MHz-OCT, we analyze them point by point and describe the appropriate solutions. We prove that coherent averaging is possible at MHz OCT-speed without special interferometer designs or digital phase stabilization. We find, that in our system up to ∼100x coherent averaging is possible while achieving a sensitivity increase close to the ideal values. This corresponds to a speed reduction from 3.3 MHz to 33 kHz and a sensitivity gain of 20 dB. We show an imaging comparison between coherent and magnitude averaging of a human finger knuckle joint in vivo with 121 dB sensitivity for the coherent case. Further, the benefits of computational downscaling in low sensitivity MHz-OCT systems are analyzed.

SELECCIÓN DE REFERENCIAS