Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
MMWR Morb Mortal Wkly Rep ; 73(39): 883-887, 2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39361547

RESUMEN

Ice machines can harbor water-related organisms, and the use of ice or tap water for clinical care activities has been associated with infections in health care settings. During 2021-2022, a total of 23 cases of infection by Burkholderia multivorans (sequence type ST659) were reported at two southern California hospitals and linked to contaminated ice and water from ice machines. In addition to these 23 cases, this report also includes 23 previously unreported cases of B. multivorans ST659 infections that occurred during 2020-2024: 13 at a northern California hospital, eight at a hospital in Colorado, and two additional cases at one of the southern California hospitals. The same brand of ice machine and brands of filters, descaling, and sanitizing products were used by all four hospitals; B. multivorans was isolated from samples collected from ice machines in two of the hospitals. Whole genome sequencing indicated that all clinical and ice machine isolates were highly genetically similar (0-14 single nucleotide variant differences across 81% of the selected reference genome). Recommendations from public health officials to halt the outbreak included avoiding ice and tap water during clinical care activities. An investigation is ongoing to determine possible sources of ice machine contamination. During outbreaks of water-related organisms in health care facilities, health care personnel should consider avoiding the use of tap water, including ice and water from ice machines, for patient care.


Asunto(s)
Infecciones por Burkholderia , Hospitales , Hielo , Humanos , California/epidemiología , Colorado/epidemiología , Hospitales/estadística & datos numéricos , Infecciones por Burkholderia/epidemiología , Microbiología del Agua , Persona de Mediana Edad , Adulto , Femenino , Masculino , Anciano , Infección Hospitalaria/epidemiología , Infección Hospitalaria/prevención & control , Brotes de Enfermedades , Complejo Burkholderia cepacia/aislamiento & purificación , Adulto Joven , Adolescente , Atención al Paciente , Anciano de 80 o más Años , Niño , Contaminación de Equipos
2.
Open Forum Infect Dis ; 11(3): ofae048, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38434615

RESUMEN

Background: Bacillus cereus is a ubiquitous gram-positive rod-shaped bacterium that can cause sepsis and neuroinvasive disease in patients with acute leukemia or neutropenia. Methods: A single-center retrospective review was conducted to evaluate patients with acute leukemia, positive blood or cerebrospinal fluid test results for B cereus, and abnormal neuroradiographic findings between January 2018 and October 2022. Infection control practices were observed, environmental samples obtained, a dietary case-control study completed, and whole genome sequencing performed on environmental and clinical Bacillus isolates. Results: Five patients with B cereus neuroinvasive disease were identified. All patients had acute myeloid leukemia (AML), were receiving induction chemotherapy, and were neutropenic. Neurologic involvement included subarachnoid or intraparenchymal hemorrhage or brain abscess. All patients were treated with ciprofloxacin and survived with limited or no neurologic sequelae. B cereus was identified in 7 of 61 environmental samples and 1 of 19 dietary protein samples-these were unrelated to clinical isolates via sequencing. No point source was identified. Ciprofloxacin was added to the empiric antimicrobial regimen for patients with AML and prolonged or recurrent neutropenic fevers; no new cases were identified in the ensuing year. Conclusions: B cereus is ubiquitous in the hospital environment, at times leading to clusters with unrelated isolates. Fastidious infection control practices addressing a range of possible exposures are warranted, but their efficacy is unknown and they may not be sufficient to prevent all infections. Thus, including B cereus coverage in empiric regimens for patients with AML and persistent neutropenic fever may limit the morbidity of this pathogen.

3.
Clin Infect Dis ; 79(1): 6-14, 2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-38315890

RESUMEN

BACKGROUND: Carbapenemase-producing, carbapenem-resistant Pseudomonas aeruginosa (CP-CRPA) are extensively drug-resistant bacteria. We investigated the source of a multistate CP-CRPA outbreak. METHODS: Cases were defined as a US patient's first isolation of P. aeruginosa sequence type 1203 with carbapenemase gene blaVIM-80 and cephalosporinase gene blaGES-9 from any specimen source collected and reported to the Centers for Disease Control and Prevention during 1 January 2022-15 May 2023. We conducted a 1:1 matched case-control study at the post-acute care facility with the most cases, assessed exposures associated with case status for all case-patients, and tested products for bacterial contamination. RESULTS: We identified 81 case-patients from 18 states, 27 of whom were identified through surveillance cultures. Four (7%) of 54 case-patients with clinical cultures died within 30 days of culture collection, and 4 (22%) of 18 with eye infections underwent enucleation. In the case-control study, case-patients had increased odds of receiving artificial tears versus controls (crude matched OR, 5.0; 95% CI, 1.1-22.8). Overall, artificial tears use was reported by 61 (87%) of 70 case-patients with information; 43 (77%) of 56 case-patients with brand information reported use of Brand A, an imported, preservative-free, over-the-counter (OTC) product. Bacteria isolated from opened and unopened bottles of Brand A were genetically related to patient isolates. Food and Drug Administration inspection of the manufacturing plant identified likely sources of contamination. CONCLUSIONS: A manufactured medical product serving as the vehicle for carbapenemase-producing organisms is unprecedented in the United States. The clinical impacts from this outbreak underscore the need for improved requirements for US OTC product importers.


Asunto(s)
Proteínas Bacterianas , Brotes de Enfermedades , Farmacorresistencia Bacteriana Múltiple , Infecciones por Pseudomonas , Pseudomonas aeruginosa , beta-Lactamasas , Humanos , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/genética , Pseudomonas aeruginosa/aislamiento & purificación , Infecciones por Pseudomonas/epidemiología , Infecciones por Pseudomonas/microbiología , Estudios de Casos y Controles , Masculino , Femenino , Persona de Mediana Edad , Farmacorresistencia Bacteriana Múltiple/genética , Anciano , Estados Unidos/epidemiología , Proteínas Bacterianas/genética , beta-Lactamasas/genética , Adulto , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Anciano de 80 o más Años , Pruebas de Sensibilidad Microbiana , Adulto Joven , Cefalosporinasa/genética , Cefalosporinasa/metabolismo , Carbapenémicos/farmacología
4.
Infect Control Hosp Epidemiol ; 45(3): 292-301, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38196201

RESUMEN

OBJECTIVE: We investigated concurrent outbreaks of Pseudomonas aeruginosa carrying blaVIM (VIM-CRPA) and Enterobacterales carrying blaKPC (KPC-CRE) at a long-term acute-care hospital (LTACH A). METHODS: We defined an incident case as the first detection of blaKPC or blaVIM from a patient's clinical cultures or colonization screening test. We reviewed medical records and performed infection control assessments, colonization screening, environmental sampling, and molecular characterization of carbapenemase-producing organisms from clinical and environmental sources by pulsed-field gel electrophoresis (PFGE) and whole-genome sequencing. RESULTS: From July 2017 to December 2018, 76 incident cases were identified from 69 case patients: 51 had blaKPC, 11 had blaVIM, and 7 had blaVIM and blaKPC. Also, blaKPC were identified from 7 Enterobacterales, and all blaVIM were P. aeruginosa. We observed gaps in hand hygiene, and we recovered KPC-CRE and VIM-CRPA from drains and toilets. We identified 4 KPC alleles and 2 VIM alleles; 2 KPC alleles were located on plasmids that were identified across multiple Enterobacterales and in both clinical and environmental isolates. CONCLUSIONS: Our response to a single patient colonized with VIM-CRPA and KPC-CRE identified concurrent CPO outbreaks at LTACH A. Epidemiologic and genomic investigations indicated that the observed diversity was due to a combination of multiple introductions of VIM-CRPA and KPC-CRE and to the transfer of carbapenemase genes across different bacteria species and strains. Improved infection control, including interventions that minimized potential spread from wastewater premise plumbing, stopped transmission.


Asunto(s)
Proteínas Bacterianas , beta-Lactamasas , Humanos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Proteínas Bacterianas/genética , beta-Lactamasas/genética , Hospitales , Klebsiella pneumoniae , Pruebas de Sensibilidad Microbiana , Plásmidos
6.
MMWR Morb Mortal Wkly Rep ; 72(31): 844-846, 2023 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-37535466

RESUMEN

Treatment of carbapenemase-producing carbapenem-resistant Pseudomonas aeruginosa (CP-CRPA) infections is challenging because of antibiotic resistance. CP-CRPA infections are highly transmissible in health care settings because they can spread from person to person and from environmental sources such as sink drains and toilets. During September 2021-January 2022, an Idaho hospital (hospital A) isolated CP-CRPA from sputum of two patients who stayed in the same intensive care unit (ICU) room (room X), 4 months apart. Both isolates had active-on-imipenem metallo-beta-lactamase (IMP) carbapenemase gene type 84 (blaIMP-84) and were characterized as multilocus sequence type 235 (ST235). A health care-associated infections team from the Idaho Division of Public Health visited hospital A during March 21-22, 2022, to discuss the cluster investigation with hospital A staff members and to collect environmental samples. CP-CRPA ST235 with blaIMP-84 was isolated from swab samples of one sink in room X, suggesting it was the likely environmental source of transmission. Recommended prevention and control measures included application of drain biofilm disinfectant, screening of future patients who stay in room X (e.g., the next 10 occupants) upon reopening, and continuing submission of carbapenem-resistant P. aeruginosa (CRPA) isolates to public health laboratories. Repeat environmental sampling did not detect any CRPA. As of December 2022, no additional CP-CRPA isolates had been reported by hospital A. Collaboration between health care facilities and public health agencies, including testing of CRPA isolates for carbapenemase genes and implementation of sink hygiene interventions, was critical in the identification of and response to this CP-CRPA cluster in a health care setting.


Asunto(s)
Carbapenémicos , Infecciones por Pseudomonas , Humanos , Adulto , Carbapenémicos/farmacología , Antibacterianos/farmacología , Pseudomonas aeruginosa/genética , Idaho/epidemiología , Infecciones por Pseudomonas/epidemiología , beta-Lactamasas/genética , Unidades de Cuidados Intensivos , Pruebas de Sensibilidad Microbiana
7.
Emerg Infect Dis ; 29(10): 1979-1989, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37561399

RESUMEN

During May 2018‒December 2022, we reviewed transfusion-transmitted sepsis cases in the United States attributable to polymicrobial contaminated apheresis platelet components, including Acinetobacter calcoaceticus‒baumannii complex or Staphylococcus saprophyticus isolated from patients and components. Transfused platelet components underwent bacterial risk control strategies (primary culture, pathogen reduction or primary culture, and secondary rapid test) before transfusion. Environmental samples were collected from a platelet collection set manufacturing facility. Seven sepsis cases from 6 platelet donations from 6 different donors were identified in patients from 6 states; 3 patients died. Cultures identified Acinetobacter calcoaceticus‒baumannii complex in 6 patients and 6 transfused platelets, S. saprophyticus in 4 patients and 4 transfused platelets. Whole-genome sequencing showed environmental isolates from the manufacturer were closely related genetically to patient and platelet isolates, indicating the manufacturer was the most probable source of recurrent polymicrobial contamination. Clinicians should maintain awareness of possible transfusion-transmitted sepsis even when using bacterial risk control strategies.


Asunto(s)
Plaquetas , Sepsis , Humanos , Estados Unidos/epidemiología , Transfusión de Plaquetas/efectos adversos , Sepsis/epidemiología , Sepsis/etiología , Transfusión Sanguínea , Bacterias/genética
8.
Open Forum Infect Dis ; 10(5): ofad194, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37180588

RESUMEN

Background: Contaminated healthcare facility wastewater plumbing is recognized as a source of carbapenemase-producing organism transmission. In August 2019, the Tennessee Department of Health (TDH) identified a patient colonized with Verona integron-encoded metallo-beta-lactamase-producing carbapenem-resistant Pseudomonas aeruginosa (VIM-CRPA). A record review revealed that 33% (4 of 12) of all reported patients in Tennessee with VIM had history of prior admission to acute care hospital (ACH) A intensive care unit (ICU) Room X, prompting further investigation. Methods: A case was defined as polymerase chain reaction detection of blaVIM in a patient with prior admission to ACH A from November 2017 to November 2020. The TDH performed point prevalence surveys, discharge screening, onsite observations, and environmental testing at ACH A. The VIM-CRPA isolates underwent whole-genome sequencing (WGS). Results: In a screening of 44% (n = 11) of 25 patients admitted to Room X between January and June 2020, we identified 36% (n = 4) colonized with VIM-CRPA, resulting in 8 cases associated with Room X from March 2018 to June 2020. No additional cases were identified in 2 point-prevalence surveys of the ACH A ICU. Samples from the bathroom and handwashing sink drains in Room X grew VIM-CRPA; all available case and environmental isolates were found to be ST253 harboring blaVIM-1 and to be closely related by WGS. Transmission ended after implementation of intensive water management and infection control interventions. Conclusions: A single ICU room's contaminated drains were associated with 8 VIM-CRPA cases over a 2-year period. This outbreak highlights the need to include wastewater plumbing in hospital water management plans to mitigate the risk of transmission of antibiotic-resistant organisms to patients.

9.
Emerg Infect Dis ; 29(4): 761-770, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36918377

RESUMEN

SARS-CoV-2 infections among vaccinated nursing home residents increased after the Omicron variant emerged. Data on booster dose effectiveness in this population are limited. During July 2021-March 2022, nursing home outbreaks in 11 US jurisdictions involving >3 infections within 14 days among residents who had received at least the primary COVID-19 vaccine(s) were monitored. Among 2,188 nursing homes, 1,247 outbreaks were reported in the periods of Delta (n = 356, 29%), mixed Delta/Omicron (n = 354, 28%), and Omicron (n = 536, 43%) predominance. During the Omicron-predominant period, the risk for infection within 14 days of an outbreak start was lower among boosted residents than among residents who had received the primary vaccine series alone (risk ratio [RR] 0.25, 95% CI 0.19-0.33). Once infected, boosted residents were at lower risk for all-cause hospitalization (RR 0.48, 95% CI 0.40-0.49) and death (RR 0.45, 95% CI 0.34-0.59) than primary vaccine-only residents.


Asunto(s)
COVID-19 , Estados Unidos/epidemiología , Humanos , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19 , SARS-CoV-2 , Casas de Salud , Brotes de Enfermedades
10.
Infect Control Hosp Epidemiol ; 44(6): 1005-1009, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36645205

RESUMEN

Among nursing home outbreaks of coronavirus disease 2019 (COVID-19) with ≥3 breakthrough infections when the predominant severe acute respiratory coronavirus virus 2 (SARS-CoV-2) variant circulating was the SARS-CoV-2 δ (delta) variant, fully vaccinated residents were 28% less likely to be infected than were unvaccinated residents. Once infected, they had approximately half the risk for all-cause hospitalization and all-cause death compared with unvaccinated infected residents.


Asunto(s)
COVID-19 , Virosis , Humanos , SARS-CoV-2 , Vacunas contra la COVID-19 , COVID-19/epidemiología , COVID-19/prevención & control , Casas de Salud , Brotes de Enfermedades/prevención & control
12.
J Immunol ; 208(6): 1500-1508, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-35228262

RESUMEN

Oral fluids offer a noninvasive sampling method for the detection of Abs. Quantification of IgA and IgG Abs in saliva allows studies of the mucosal and systemic immune response after natural infection or vaccination. We developed and validated an enzyme immunoassay (EIA) to detect and quantify salivary IgA and IgG Abs against the prefusion-stabilized form of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein expressed in suspension-adapted HEK-293 cells. Normalization against total Ab isotype was performed to account for specimen differences, such as collection time and sample volume. Saliva samples collected from 187 SARS-CoV-2 confirmed cases enrolled in 2 cohorts and 373 prepandemic saliva samples were tested. The sensitivity of both EIAs was high (IgA, 95.5%; IgG, 89.7%) without compromising specificity (IgA, 99%; IgG, 97%). No cross-reactivity with endemic coronaviruses was observed. The limit of detection for SARS-CoV-2 salivary IgA and IgG assays were 1.98 ng/ml and 0.30 ng/ml, respectively. Salivary IgA and IgG Abs were detected earlier in patients with mild COVID-19 symptoms than in severe cases. However, severe cases showed higher salivary Ab titers than those with a mild infection. Salivary IgA titers quickly decreased after 6 wk in mild cases but remained detectable until at least week 10 in severe cases. Salivary IgG titers remained high for all patients, regardless of disease severity. In conclusion, EIAs for both IgA and IgG had high specificity and sensitivity for the confirmation of current or recent SARS-CoV-2 infections and evaluation of the IgA and IgG immune response.


Asunto(s)
Anticuerpos Antivirales/metabolismo , COVID-19/diagnóstico , Ensayo de Inmunoadsorción Enzimática/métodos , Inmunoglobulina A/metabolismo , Inmunoglobulina G/metabolismo , SARS-CoV-2/fisiología , Saliva/metabolismo , Adolescente , Adulto , Anciano , Enfermedades Asintomáticas , Niño , Preescolar , Progresión de la Enfermedad , Ensayo de Inmunoadsorción Enzimática/normas , Femenino , Humanos , Lactante , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Pandemias , Estándares de Referencia , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Adulto Joven
13.
Infect Control Hosp Epidemiol ; 43(10): 1333-1338, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34612179

RESUMEN

BACKGROUND: In 2015, an international outbreak of Mycobacterium chimaera infections among patients undergoing cardiothoracic surgeries was associated with exposure to contaminated LivaNova 3T heater-cooler devices (HCDs). From June 2017 to October 2020, the Centers for Disease Control and Prevention was notified of 18 patients with M. chimaera infections who had undergone cardiothoracic surgeries at 2 hospitals in Kansas (14 patients) and California (4 patients); 17 had exposure to 3T HCDs. Whole-genome sequencing of the clinical and environmental isolates matched the global outbreak strain identified in 2015. METHODS: Investigations were conducted at each hospital to determine the cause of ongoing infections. Investigative methods included query of microbiologic records to identify additional cases, medical chart review, observations of operating room setup, HCD use and maintenance practices, and collection of HCD and environmental samples. RESULTS: Onsite observations identified deviations in the positioning and maintenance of the 3T HCDs from the US Food and Drug Administration (FDA) recommendations and the manufacturer's updated cleaning and disinfection protocols. Additionally, most 3T HCDs had not undergone the recommended vacuum and sealing upgrades by the manufacturer to decrease the dispersal of M. chimaera-containing aerosols into the operating room, despite hospital requests to the manufacturer. CONCLUSIONS: These findings highlight the need for continued awareness of the risk of M. chimaera infections associated with 3T HCDs, even if the devices are newly manufactured. Hospitals should maintain vigilance in adhering to FDA recommendations and the manufacturer's protocols and in identifying patients with potential M. chimaera infections with exposure to these devices.


Asunto(s)
Infecciones por Mycobacterium no Tuberculosas , Infecciones por Mycobacterium , Humanos , Contaminación de Equipos , Kansas , Quimera , Infecciones por Mycobacterium/epidemiología , Infecciones por Mycobacterium/etiología , Complejo Mycobacterium avium , Aerosoles , Infecciones por Mycobacterium no Tuberculosas/epidemiología , Infecciones por Mycobacterium no Tuberculosas/etiología , Infecciones por Mycobacterium no Tuberculosas/prevención & control
14.
Infect Control Hosp Epidemiol ; 43(11): 1610-1617, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-34802478

RESUMEN

OBJECTIVE: To characterize and compare severe acute respiratory coronavirus virus 2 (SARS-CoV-2)-specific immune responses in plasma and gingival crevicular fluid (GCF) from nursing home residents during and after natural infection. DESIGN: Prospective cohort. SETTING: Nursing home. PARTICIPANTS: SARS-CoV-2-infected nursing home residents. METHODS: A convenience sample of 14 SARS-CoV-2-infected nursing home residents, enrolled 4-13 days after real-time reverse transcription polymerase chain reaction diagnosis, were followed for 42 days. After diagnosis, plasma SARS-CoV-2-specific pan-Immunoglobulin (Ig), IgG, IgA, IgM, and neutralizing antibodies were measured at 5 time points, and GCF SARS-CoV-2-specific IgG and IgA were measured at 4 time points. RESULTS: All participants demonstrated immune responses to SARS-CoV-2 infection. Among 12 phlebotomized participants, plasma was positive for pan-Ig and IgG in all 12 participants. Neutralizing antibodies were positive in 11 participants; IgM was positive in 10 participants, and IgA was positive in 9 participants. Among 14 participants with GCF specimens, GCF was positive for IgG in 13 participants and for IgA in 12 participants. Immunoglobulin responses in plasma and GCF had similar kinetics; median times to peak antibody response were similar across specimen types (4 weeks for IgG; 3 weeks for IgA). Participants with pan-Ig, IgG, and IgA detected in plasma and GCF IgG remained positive throughout this evaluation, 46-55 days after diagnosis. All participants were viral-culture negative by the first detection of antibodies. CONCLUSIONS: Nursing home residents had detectable SARS-CoV-2 antibodies in plasma and GCF after infection. Kinetics of antibodies detected in GCF mirrored those from plasma. Noninvasive GCF may be useful for detecting and monitoring immunologic responses in populations unable or unwilling to be phlebotomized.


Asunto(s)
COVID-19 , Neumonía , Humanos , SARS-CoV-2 , Formación de Anticuerpos , Líquido del Surco Gingival/química , Inmunoglobulina M , Anticuerpos Antivirales , Arkansas , Estudios Prospectivos , COVID-19/diagnóstico , Inmunoglobulina A/análisis , Inmunoglobulina G , Anticuerpos Neutralizantes , Casas de Salud
15.
JAMA Netw Open ; 4(10): e2128615, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34618037

RESUMEN

Importance: The number of clinics marketing stem cell products for joint diseases, chronic pain, and most recently, COVID-19, has increased despite warnings from the US Food and Drug Administration that stem cell products for these and other indications have not been proven safe or effective. Objective: To examine bacterial infections in 20 patients who received umbilical cord blood-derived products marketed as stem cell treatment. Design, Setting, and Participants: This case series is a national public health investigation including case-finding, medical record review and abstraction, and laboratory investigation, including sterility testing of products and whole-genome sequencing of patient and product isolates. Participants included patients who developed bacterial infections following administration of umbilical cord blood-derived products marketed as stem cell treatment during August 2017 to September 2018. Data analysis was performed from March 2019 to September 2021. Exposures: Umbilical cord blood-derived products marketed as stem cell treatment. Main Outcomes and Measures: Data were collected on patient infections and exposures. The Centers for Disease Control and Prevention performed sterility testing on undistributed and distributed vials of product marketed as stem cell treatment and performed whole-genome sequencing to compare patient and product bacterial isolates. Results: Culture-confirmed bacterial infections were identified in 20 patients (median [range] age, 63 [2-89] years; 13 male patients [65%]) from 8 US states who sought stem cell treatment for conditions including pain, osteoarthritis, rheumatoid arthritis, and injury; all but 1 required hospitalization. The most frequently isolated bacteria from patients with infections were common enteric species, including Escherichia coli (14 patients) and Enterobacter cloacae (7 patients). Of unopened, undistributed products sampled for testing, 65% (22 of 34 vials) were contaminated with at least 1 of 16 bacterial species, mostly enteric. A patient isolate from Arizona matched isolates obtained from products administered to patients in Florida, and patient isolates from Texas matched undistributed product sent from the company in California. Conclusions and Relevance: Unapproved stem cell products can expose patients to serious risks without proven benefit. Sequencing results suggest a common source of extensive contamination, likely occurring during the processing of cord blood into product. Patients and health care practitioners who are considering the use of unapproved products marketed as stem cell treatment should be aware of their unproven benefits and potential risks, including serious infections.


Asunto(s)
Infecciones Bacterianas/etiología , Seguridad de la Sangre/estadística & datos numéricos , Trasplante de Células Madre de Sangre del Cordón Umbilical/efectos adversos , Brotes de Enfermedades , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Infecciones Bacterianas/epidemiología , Infecciones Bacterianas/prevención & control , Seguridad de la Sangre/normas , Centers for Disease Control and Prevention, U.S. , Niño , Preescolar , Trasplante de Células Madre de Sangre del Cordón Umbilical/normas , Femenino , Humanos , Masculino , Mercadotecnía , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Vigilancia en Salud Pública , Estados Unidos/epidemiología , United States Food and Drug Administration , Adulto Joven
16.
medRxiv ; 2021 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-34518840

RESUMEN

Oral fluids offer a non-invasive sampling method for the detection of antibodies. Quantification of IgA and IgG antibodies in saliva allows studies of the mucosal and systemic immune response after natural infection or vaccination. We developed and validated an enzyme immunoassay (EIA) to detect and quantify salivary IgA and IgG antibodies against the prefusion-stabilized form of the SARS-CoV-2 spike protein. Normalization against total antibody isotype was performed to account for specimen differences, such as collection time and sample volume. Saliva samples collected from 187 SARS-CoV-2 confirmed cases enrolled in 2 cohorts and 373 pre-pandemic saliva samples were tested. The sensitivity of both EIAs was high (IgA: 95.5%; IgG: 89.7%) without compromising specificity (IgA: 99%; IgG: 97%). No cross reactivity with seasonal coronaviruses was observed. The limit of detection for SARS-CoV-2 salivary IgA and IgG assays were 1.98 ng/mL and 0.30 ng/mL, respectively. Salivary IgA and IgG antibodies were detected earlier in patients with mild COVID-19 symptoms than in severe cases. However, severe cases showed higher salivary antibody titers than those with a mild infection. Salivary IgA titers quickly decreased after 6 weeks in mild cases but remained detectable until at least week 10 in severe cases. Salivary IgG titers remained high for all patients, regardless of disease severity. In conclusion, EIAs for both IgA and IgG had high specificity and sensitivity for the confirmation of current or recent SARS-CoV-2 infections and evaluation of the IgA and IgG immune response.

17.
Am J Infect Control ; 49(10): 1318-1321, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34375701

RESUMEN

Facility-wide testing performed at 4 outpatient hemodialysis facilities in the absence of an outbreak or escalating community incidence did not identify new SARS-CoV-2 infections and illustrated key logistical considerations essential to successful implementation of SARS-CoV-2 screening. Facilities could consider prioritizing facility-wide SARS-CoV-2 testing during suspicion of an outbreak in the facility or escalating community spread without robust infection control strategies in place. Being prepared to address operational considerations will enhance implementation of facility-wide testing in the outpatient dialysis setting.


Asunto(s)
COVID-19 , Fallo Renal Crónico , Prueba de COVID-19 , Humanos , Pacientes Ambulatorios , Diálisis Renal/efectos adversos , SARS-CoV-2
18.
Clin Infect Dis ; 73(Suppl 1): S58-S64, 2021 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-33909063

RESUMEN

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing remains essential for early identification and clinical management of cases. We compared the diagnostic performance of 3 specimen types for characterizing SARS-CoV-2 in infected nursing home residents. METHODS: A convenience sample of 17 residents were enrolled within 15 days of first positive SARS-CoV-2 result by real-time reverse transcription polymerase chain reaction (RT-PCR) and prospectively followed for 42 days. Anterior nasal swabs (AN), oropharyngeal swabs (OP), and saliva specimens (SA) were collected on the day of enrollment, every 3 days for the first 21 days, and then weekly for 21 days. Specimens were tested for presence of SARS-CoV-2 RNA using RT-PCR and replication-competent virus by viral culture. RESULTS: Comparing the 3 specimen types collected from each participant at each time point, the concordance of paired RT-PCR results ranged from 80% to 88%. After the first positive result, SA and OP were RT-PCR-positive for ≤48 days; AN were RT-PCR-positive for ≤33 days. AN had the highest percentage of RT-PCR-positive results (21/26 [81%]) when collected ≤10 days of participants' first positive result. Eleven specimens were positive by viral culture: 9 AN collected ≤19 days following first positive result and 2 OP collected ≤5 days following first positive result. CONCLUSIONS: AN, OP, and SA were effective methods for repeated testing in this population. More AN than OP were positive by viral culture. SA and OP remained RT-PCR-positive longer than AN, which could lead to unnecessary interventions if RT-PCR detection occurred after viral shedding has likely ceased.


Asunto(s)
COVID-19 , SARS-CoV-2 , Arkansas , Humanos , Casas de Salud , ARN Viral/genética
19.
Open Forum Infect Dis ; 8(3): ofab048, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33723510

RESUMEN

BACKGROUND: To estimate the infectious period of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in older adults with underlying conditions, we assessed duration of coronavirus disease 2019 (COVID-19) symptoms, reverse-transcription polymerase chain reaction (RT-PCR) positivity, and culture positivity among nursing home residents. METHODS: We enrolled residents within 15 days of their first positive SARS-CoV-2 test (diagnosis) at an Arkansas facility from July 7 to 15, 2020 and instead them for 42 days. Every 3 days for 21 days and then weekly, we assessed COVID-19 symptoms, collected specimens (oropharyngeal, anterior nares, and saliva), and reviewed medical charts. Blood for serology was collected on days 0, 6, 12, 21, and 42. Infectivity was defined by positive culture. Duration of culture positivity was compared with duration of COVID-19 symptoms and RT-PCR positivity. Data were summarized using measures of central tendency, frequencies, and proportions. RESULTS: We enrolled 17 of 39 (44%) eligible residents. Median participant age was 82 years (range, 58-97 years). All had ≥3 underlying conditions. Median duration of RT-PCR positivity was 22 days (interquartile range [IQR], 8-31 days) from diagnosis; median duration of symptoms was 42 days (IQR, 28-49 days). Of 9 (53%) participants with any culture-positive specimens, 1 (11%) severely immunocompromised participant remained culture-positive 19 days from diagnosis; 8 of 9 (89%) were culture-positive ≤8 days from diagnosis. Seroconversion occurred in 12 of 12 (100%) surviving participants with ≥1 blood specimen; all participants were culture-negative before seroconversion. CONCLUSIONS: Duration of infectivity was considerably shorter than duration of symptoms and RT-PCR positivity. Severe immunocompromise may prolong SARS-CoV-2 infectivity. Seroconversion indicated noninfectivity in this cohort.

20.
Kidney360 ; 2(12): 1917-1927, 2021 12 30.
Artículo en Inglés | MEDLINE | ID: mdl-35419540

RESUMEN

Background: Patients with ESKD on maintenance dialysis receive dialysis in common spaces with other patients and have a higher risk of severe SARS-CoV-2 infections. They may have persistently or intermittently positive SARS-CoV-2 RT-PCR tests after infection. We describe the clinical course of SARS-CoV-2 infection and the serologic response in a convenience sample of patients with ESKD to understand the duration of infectivity. Methods: From August to November 2020, we enrolled patients on maintenance dialysis with SARS-CoV-2 infections from outpatient dialysis facilities in Atlanta, Georgia. We followed participants for approximately 42 days. We assessed COVID-19 symptoms and collected specimens. Oropharyngeal (OP), anterior nasal (AN), and saliva (SA) specimens were tested for the presence of SARS-CoV-2 RNA, using RT-PCR, and sent for viral culture. Serology, including neutralizing antibodies, was measured in blood specimens. Results: Fifteen participants, with a median age of 58 (range, 37‒77) years, were enrolled. Median duration of RT-PCR positivity from diagnosis was 18 days (interquartile range [IQR], 8‒24 days). Ten participants had at least one, for a total of 41, positive RT-PCR specimens ≥10 days after symptoms onset. Of these 41 specimens, 21 underwent viral culture; one (5%) was positive 14 days after symptom onset. Thirteen participants developed SARS-CoV-2-specific antibodies, 11 of which included neutralizing antibodies. RT-PCRs remained positive after seroconversion in eight participants and after detection of neutralizing antibodies in four participants; however, all of these samples were culture negative. Conclusions: Patients with ESKD on maintenance dialysis remained persistently and intermittently SARS-CoV-2-RT-PCR positive. However, of the 15 participants, only one had infectious virus, on day 14 after symptom onset. Most participants mounted an antibody response, including neutralizing antibodies. Participants continued having RT-PCR-positive results in the presence of SARS-CoV-2-specific antibodies, but without replication-competent virus detected.


Asunto(s)
COVID-19 , Adulto , Anciano , Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19/complicaciones , Humanos , Persona de Mediana Edad , Pacientes Ambulatorios , ARN Viral , Diálisis Renal , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...