1.
Endoscopy ; 43(7): 604-16, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21623559

RESUMEN

BACKGROUND AND STUDY AIMS: Low dose photodynamic therapy (LDPDT) may modify the mucosal immune response and may thus provide a therapy for Crohn's disease. We evaluated the efficacy and safety of this technique in a murine T cell-mediated colitis model. METHODS: The safety of LDPDT was first tested in BALB/c mice. Naïve T cells were used to induce colitis in mice with severe combined immunodeficiency, which were followed up endoscopically, and a murine endoscopic index of colitis (MEIC) was developed. The efficacy of LDPDT (10 J/cm (2); delta-aminolevulinic acid, 15 mg/kg bodyweight) was then tested on mice with moderate colitis, while a disease control group received no treatment. The MEIC, weight, length, and histology of the colon, cytokine expression indices, number of mucosal CD4 (+) T cells, percentage of apoptotic CD4 (+) T cells, body weight, and systemic side effects were evaluated. RESULTS: LDPDT improved the MEIC ( P = 0.011) and the histological score ( P = 0.025), diminished the expression indices of the proinflammatory cytokines, interleukin-6 ( P = 0.042), interleukin-17 ( P = 0.029), and interferon-gamma ( P = 0.014), decreased the number of mucosal CD4 (+) T cells, and increased the percentage of apoptotic CD4 (+) T cells compared with the disease control group. No local or systemic side effects occurred. CONCLUSION: LDPDT improves murine T cell-mediated colitis, decreases the proinflammatory cytokines interleukin-6, interleukin-17, and interferon-gamma, and decreases the number of CD4 (+) T cells. No adverse events were observed. Therefore, this technique is now being evaluated in patients with inflammatory bowel disease.


Asunto(s)
Ácido Aminolevulínico/administración & dosificación , Colitis/tratamiento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/administración & dosificación , Animales , Apoptosis , Recuento de Linfocito CD4 , Linfocitos T CD4-Positivos/inmunología , Linfocitos T CD4-Positivos/fisiología , Colitis/inmunología , Colitis/metabolismo , Colonoscopía , Citocinas/biosíntesis , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Ratones , Ratones Endogámicos BALB C , Reacción en Cadena de la Polimerasa , Linfocitos T
2.
Photodiagnosis Photodyn Ther ; 5(2): 139-47, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19356645

RESUMEN

To detect bronchial carcinoma by autofluorescence, we measured the spectra of tumor and normal tissue in situ, in an in vivo model and in vitro by fiber optic spectrometer and two-dimensional resolved microspectroscopy. The in situ measurements were performed in bronchi of nine patients with squamous cell carcinoma during regular bronchoscopy with autofluorescence assistance. The fluorescence was monitored with a fiber optical spectrometer under blue light excitation (lambda=405nm). In an in vivo model, the resected lobe of a lung was perfused under physiological conditions. Tumorous and normal tissues were examined spectroscopically during perfusion and after blood removal and substitution with formol. In another setup the wavelength dependency of autofluorescence was examined on resected parts of physiological bronchi and central bronchial carcinomas. Under the variation of the excitation from 385 to 465nm the autofluorescence response was monitored with a fiber optic spectrometer. For investigation of the origin of autofluorescence, two-dimensional resolved spectroscopy was performed with the SpectraCube system on several sections of tumor and normal tissues All measurements, performed in vivo, in the in vivo model and in vitro agreed, that the main difference of the autofluorescence between tumor and normal bronchus tissue is the intensity of the fluorescences' main peak at 505nm. The signal on tumor tissue is in all cases significantly lower than that of normal tissue. The shape of the autofluorescence peaks is in healthy and carcinoma tissue approximately the same with two characteristic minima at 540 and 580nm. After the preparation with formaldehyde those minima disappeared from the spectra. A comparison with the absorption spectra of hemoglobin showed, that the variation of the spectra may be due to the blood content in the tissue. Two-dimensional spatially resolved spectroscopy showed, that the lower intensity of fluorescence in tumor tissue is due to the irregular and low-concentrated formation of fluorescent structures, which seen to be the elastic structures of bronchial tissue.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico , Neoplasias Pulmonares/diagnóstico , Modelos Biológicos , Espectrometría de Fluorescencia , Bronquios/citología , Carcinoma de Células Escamosas/patología , Humanos , Neoplasias Pulmonares/patología , Neoplasias , Estándares de Referencia , Espectrometría de Fluorescencia/clasificación , Espectrometría de Fluorescencia/métodos
3.
Phys Med Biol ; 52(8): N163-71, 2007 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-17404451

RESUMEN

We present the design of a sterilizable optical reference to characterize and quantify the inter-patient variations in tissue autofluorescence during autofluorescence bronchoscopy with Richard Wolf's diagnostic autofluorescence endoscopy (DAFE) system. The reference was designed to have optical and spectral properties similar to those of the human bronchial wall in spectral conditions corresponding to autofluorescence bronchoscopy conducted with the DAFE system (fluorescence excitation at 390-470 nm and red backscattering light at 590-680 nm). The reference's effective attenuation coefficient and reflectance were measured at 675 nm. In addition, its fluorescence emission spectrum was determined under 430 nm wavelength excitation. The reference is photostable, reproducible, biocompatible and small enough to be easily inserted through the working channel of a conventional bronchofibrescope. This cylindrical (length: 2 mm; diameter: 2 mm) optical reference was validated in a clinical environment.


Asunto(s)
Broncoscopios/normas , Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/normas , Microscopía Fluorescente/instrumentación , Microscopía Fluorescente/normas , Óptica y Fotónica/instrumentación , Calibración , Diseño de Equipo , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Suiza
4.
Endoscopy ; 35(8): 663-8, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12929061

RESUMEN

BACKGROUND AND STUDY AIMS: Barrett's esophagus is strongly associated with adenocarcinoma. Early malignant transformation of the Barrett's mucosa is often not visible endoscopically and may remain undetected until the invasive adenocarcinoma stage. Endoscopic surveillance is currently carried out on random four-quadrant biopsies at 1-2 cm intervals. Endoscopic fluorescence detection of protoporphyrin IX induced by 5-aminolevulinic acid can identify premalignant lesions. This study evaluates endoscopic fluorescence detection in patients having Barrett's esophagus and compares the results to those of standard endoscopy with random four-quadrant biopsies. PATIENTS AND METHODS: The study included 30 examinations in 28 patients (22 men, 6 women; age range 37-78 years, mean age 60 years,), with five patients having known intraepithelial neoplasia. A dose of 20 mg/kg of 5-aminolevulinic acid was given orally 5 hours before examination. Random four-quadrant biopsies were performed 4-6 weeks before endoscopic fluorescence detection. RESULTS: Of the biopsies taken during the endoscopic fluorescence detection procedure, 28 % (23/81) were true positives. More than one-third of the false-positive results were due to inflammation. None of the 97 control biopsies taken on nonfluorescing areas during endoscopic fluorescence detection were dysplastic. Endoscopic fluorescence detection showed low-grade intraepithelial neoplasia in five patients which was not diagnosed with random four-quadrant biopsies, while random four-quadrant biopsies alone showed three low-grade intraepithelial neoplasias that were invisible during endoscopic fluorescence detection. All high-grade intraepithelial neoplasias or adenocarcinomas (2/2) were detected with both methods. CONCLUSIONS: Fluorescence detection achieved a similar performance when compared with four-quadrant random biopsy, but resulted in fewer biopsies (81 for endoscopic fluorescence detection vs 531 for random four-quadrant biopsies).


Asunto(s)
Ácido Aminolevulínico/administración & dosificación , Esófago de Barrett/complicaciones , Esófago de Barrett/diagnóstico por imagen , Carcinoma in Situ/diagnóstico por imagen , Carcinoma in Situ/etiología , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/etiología , Esofagoscopía , Fluorescencia , Fármacos Fotosensibilizantes/administración & dosificación , Protoporfirinas/administración & dosificación , Administración Oral , Adulto , Anciano , Esófago de Barrett/patología , Carcinoma in Situ/patología , Neoplasias Esofágicas/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Radiografía , Reproducibilidad de los Resultados
5.
Br J Cancer ; 88(11): 1780-4, 2003 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-12771995

RESUMEN

The unfailing detection of micrometastases during surgery of patients suffering from ovarian cancer is mandatory for the optimal management of this disease. Thus, the present study aimed at determining the feasibility of detecting micrometastases in an ovarian cancer model using the intraperitoneal administration of the photosensitiser precursor hexaminolaevulinate (HAL). For this purpose, HAL was applied intraperitoneally at different concentrations (4-12 mM) to immunocompetent Fischer 344 rats bearing a syngeneic epithelial ovarian carcinoma. The tumours were visualised laparoscopically using both white and blue light (D-light, Karl Storz, Tuttlingen, Germany), and the number of peritoneal micrometastases detected through HAL-induced photodiagnosis (PD) was compared to standard white light visualisation. Fluorescence spectra were recorded with an optical fibre-based spectrofluorometer and the fluorescence intensities were compared to the protoporphyrin IX (PpIX) fluorescence induced by 5-aminolevulinic acid under similar conditions. The number of metastases detected by the PD blue light mode was higher than when using standard white light abdominal inspection for all applied concentrations. Twice as many cancer lesions were detected by fluorescence than by white light inspection. The hexyl-ester derivative produced higher PpIX fluorescence than its parent substance aminolevulinic acid at the same concentration and application time. Fluorescence contrast between healthy and cancerous tissue was excellent for both compounds. To overcome poor diagnostic efficiency and to detect peritoneal ovarian carcinoma foci in the large surface area of the human peritoneal cavity, HAL fluorescence-based visualisation techniques may acquire importance in future and lead to a more correct staging of early ovarian cancer.


Asunto(s)
Ácido Aminolevulínico , Neoplasias Ováricas/diagnóstico , Neoplasias Peritoneales/diagnóstico , Fármacos Fotosensibilizantes , Animales , Técnicas y Procedimientos Diagnósticos , Modelos Animales de Enfermedad , Evaluación Preclínica de Medicamentos , Epitelio/metabolismo , Epitelio/patología , Estudios de Factibilidad , Femenino , Fluorescencia , Estadificación de Neoplasias , Neoplasias Ováricas/patología , Neoplasias Peritoneales/secundario , Pronóstico , Protoporfirinas/metabolismo , Ratas , Ratas Endogámicas F344 , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...