1.
Diabetes Care ; 46(10): 1831-1838, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37566697

RESUMEN

OBJECTIVE: We explored longitudinal changes associated with switching to hybrid closed-loop (HCL) insulin delivery systems in adults with type 1 diabetes and elevated HbA1c levels despite the use of intermittently scanned continuous glucose monitoring (isCGM) and insulin pump therapy. RESEARCH DESIGN AND METHODS: We undertook a pragmatic, preplanned observational study of participants included in the National Health Service England closed-loop pilot. Adults using isCGM and insulin pump across 31 diabetes centers in England with an HbA1c ≥8.5% who were willing to commence HCL therapy were included. Outcomes included change in HbA1c, sensor glucometrics, diabetes distress score, Gold score (hypoglycemia awareness), acute event rates, and user opinion of HCL. RESULTS: In total, 570 HCL users were included (median age 40 [IQR 29-50] years, 67% female, and 85% White). Mean baseline HbA1c was 9.4 ± 0.9% (78.9 ± 9.1 mmol/mol) with a median follow-up of 5.1 (IQR 3.9-6.6) months. Of 520 users continuing HCL at follow-up, mean adjusted HbA1c reduced by 1.7% (95% CI 1.5, 1.8; P < 0.0001) (18.1 mmol/mol [95% CI 16.6, 19.6]; P < 0.0001). Time in range (70-180 mg/dL) increased from 34.2 to 61.9% (P < 0.001). Individuals with HbA1c of ≤58 mmol/mol rose from 0 to 39.4% (P < 0.0001), and those achieving ≥70% glucose time in range and <4% time below range increased from 0.8 to 28.2% (P < 0.0001). Almost all participants rated HCL therapy as having a positive impact on quality of life (94.7% [540 of 570]). CONCLUSIONS: Use of HCL is associated with improvements in HbA1c, time in range, hypoglycemia, and diabetes-related distress and quality of life in people with type 1 diabetes in the real world.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Adulto , Femenino , Masculino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada , Glucemia , Automonitorización de la Glucosa Sanguínea , Calidad de Vida , Medicina Estatal , Insulina , Sistemas de Infusión de Insulina
2.
Diabet Med ; 40(7): e15078, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36932929

RESUMEN

This best practice guide is written with the aim of providing an overview of current hybrid closed-loop (HCL) systems in use within the United Kingdom's (UK) National Health Service (NHS) and to provide education and advice for their management on both an individual and clinical service level. The environment of diabetes technology, and particularly HCL systems, is rapidly evolving. The past decade has seen unprecedented advances in the development of HCL systems. These systems improve glycaemic outcomes and reduce the burden of treatment for people with type 1 diabetes (pwT1D). It is anticipated that access to these systems will increase in England as a result of updates in National Institute of Health and Care Excellence (NICE) guidance providing broader support for the use of real-time continuous glucose monitoring (CGM) for pwT1D. NICE is currently undertaking multiple-technology appraisal into HCL systems. Based on experience from centres involved in supporting advanced technologies as well as from the recent NHS England HCL pilot, this guide is intended to provide healthcare professionals with UK expert consensus on the best practice for initiation, optimisation and ongoing management of HCL therapy.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Humanos , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Inglaterra , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Medicina Estatal , Tecnología
3.
Endocr Rev ; 44(2): 254-280, 2023 03 04.
Artículo en Inglés | MEDLINE | ID: mdl-36066457

RESUMEN

The significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers, and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past 6 years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapéutico , Hipoglucemiantes/uso terapéutico , Consenso , Glucemia , Automonitorización de la Glucosa Sanguínea
4.
Diabetes Obes Metab ; 23(8): 1989-1994, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33999488

RESUMEN

We report a real-world evaluation of the first commercially approved automated insulin delivery (AID) system, MiniMed 670G (670G), and open source-automated insulin delivery (OS-AID) systems. This was undertaken as a retrospective observational study in adults with type 1 diabetes using AID systems for 6 months or longer in a publicly funded health service using clinically validated data. Sixty-eight adults (38 670G, 30 OS-AID systems) were included. OS-AID system users were younger, had a shorter diabetes duration and a higher education status. OS-AID systems displayed a significantly better change in HbA1c (median -0.9% [-0.4%, -1.1%] vs. -0.1% [IQR -0.7%, 0.2%], P = .004) and time in range 3.9-10 mmol/L (mean 78.5%, SD ± 12.0% vs. 68.2% ± 14.7%, P = .024) compared with 670G. Both systems showed minimal hypoglycaemia, with OS-AID systems revealing significantly improved secondary outcomes of mean glucose and percentage of time more than 10 mmol/L, with a higher percentage of time of less than 3 mmol/L. OS-AID system users displayed improved glycaemic outcomes with no clinical safety concerns compared with 670G, although higher weight-adjusted insulin dose and weight gain were noted. The study highlights key differences in OS-AID system user characteristics that are important for interpreting real-world findings from recent OS-AID system studies.


Asunto(s)
Diabetes Mellitus Tipo 1 , Páncreas Artificial , Adulto , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina
5.
Diabetes Care ; 36(12): 4160-2, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24103902

RESUMEN

OBJECTIVE: To evaluate the effect of continuous glucose monitoring (CGM) on the frequency of severe hypoglycemia (SH) in patients with established hypoglycemia unawareness. RESEARCH DESIGN AND METHODS: We conducted a retrospective audit of 35 patients with type 1 diabetes and problematic hypoglycemia unawareness, despite optimized medical therapy (continuous subcutaneous insulin infusion/multiple daily insulin injections), who used CGM for >1 year. RESULTS: Over a 1-year follow-up period, the median rates of SH were reduced from 4.0 (interquartile range [IQR] 0.75-7.25) episodes/patient-year to 0.0 (0.0-1.25) episodes/patient-year (P < 0.001), and the mean (±SD) rates were reduced from 8.1 ± 13 to 0.6 ± 1.2 episodes/year (P = 0.005). HbA1c was reduced from 8.1 ± 1.2% to 7.6 ± 1.0% over the year (P = 0.005). The mean Gold score, measured in 19 patients, did not change: 5.1 ± 1.5 vs. 5.2 ± 1.9 (P = 0.67). CONCLUSIONS: In a specialist experienced insulin pump center, in carefully selected patients, CGM reduced SH while improving HbA1c but failed to restore hypoglycemia awareness.


Asunto(s)
Concienciación , Diabetes Mellitus Tipo 1/sangre , Hipoglucemia/prevención & control , Insulina/administración & dosificación , Adulto , Auditoría Clínica , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Técnica de Clampeo de la Glucosa , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/psicología , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Infusiones Subcutáneas , Inyecciones Subcutáneas , Insulina/efectos adversos , Sistemas de Infusión de Insulina , Masculino , Pronóstico , Proyectos de Investigación , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo