Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(7)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38610601

RESUMEN

Objectives: To compare complications associated with percutaneous gastrostomies performed using PUSH and PULL techniques, whether endoscopic (PEG) or radiological (PRG), in a tertiary-level hospital. Methods: This was a prospective observational study. Adult patients who underwent percutaneous PULL or PUSH gastrostomy using PEG or PRG techniques at the Virgen del Rocio University Hospital and subsequently followed up in the Nutrition Unit between 2009-2020 were included. X2 tests or Fisher's test were used for the comparison of proportions when necessary. Univariate analysis was conducted to study risk factors for PRG-associated complications. Results: n = 423 (PULL = 181; PUSH = 242). The PULL technique was associated with a higher percentage of total complications (37.6% vs. 23.8%; p = 0.005), exudate (18.2% vs. 11.2%; p = 0.039), and irritation (3.3% vs. 0%; p = 0.006). In the total sample, there were 5 (1.1%) cases of peritonitis, 3 (0.7%) gastrocolic fistulas, and 1 (0.2%) death due to complications associated with gastrostomy. Gender, age, and different indications were not risk factors for a higher number of complications. The most common indications were neurological diseases (35.9%), head and neck cancer (29%), and amyotrophic lateral sclerosis (17.2%). Conclusions: The PULL technique was associated with more total complications than the PUSH technique, but both were shown to be safe techniques, as the majority of complications were minor.

2.
Front Med (Lausanne) ; 10: 1191204, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37915325

RESUMEN

Objectives: To describe the complications associated with the different gastrostomy techniques [endoscopic (PEG), radiologic (PRG), and surgical (SG)] performed in the last 26 years in a terciary hospital. Methods: Retrospective observational study. Patients who underwent gastrostomy at the Virgen del Rocío University Hospital between 1995 and 2021 were included. For PEG, the PULL technique was performed until 2018 and subsequently the PUSH technique predominantly. For PRG, a pigtail catheter was used until 2003, a balloon catheter between 2003 and 2009, and a balloon catheter with gastropexy between 2015 and 2021. For SG, the conventional technique (CSG) was performed until 2009 and since then the laparoscopic assisted percutaneous gastrostomy (PLAG) technique. Descriptive analysis was performed obtaining the median and quartiles of the quantitative variables [P50 (P25-P75)] and the frequency for the qualitative variables [n (%)].The comparison of complications between patients who underwent different techniques was performed with Fisher's test. Results: n = 1,070 (PEG = 608, PRG = 344, SG = 118). The three most frequent indications were head and neck tumors, neurological diseases and gastroesophageal tumors. The percentage of patients who had any complication was 48.9% (PEG-PULL), 23.7% (PEG-PUSH), 38.5% (pigtail PRG), 39.2% (balloon PRG), 29.7% (balloon with gastropexy PRG), 87.3% (CSG), and 41.26% (PLAG). 2 (0.18%) patients died from gastrostomy-related complications. 18(1.68%) presented with peritonitis and 5 (0.4%) presented with gastrocolic fistula. The rest of the complications were minor. Conclusion: Gastrostomy in any of its modalities is currently a safe procedure with a low rate of complications, most of which are minor.

3.
Nutrients ; 14(22)2022 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-36432521

RESUMEN

OBJECTIVES: We aimed to describe and compare the complications associated with different percutaneous radiologic gastrostomy (PRG) techniques. METHODS: A retrospective and prospective observational study was conducted. Patients who underwent a PRG between 1995-2020 were included. TECHNIQUES: A pigtail catheter was used until 2003, a balloon catheter without pexy was used between 2003-2009 and a balloon catheter with gastropexy was used between 2015-2021. For the comparison of proportions, X2 tests or Fisher's test were used when necessary. Univariate analysis was performed to study the risk factors for PRG-associated complications. RESULTS: n = 330 (pigtail = 114, balloon-type without pexy = 28, balloon-type with pexy = 188). The most frequent indication was head and neck cancer. The number of patients with complications was 44 (38.5%), 11 (39.2%) and 54 (28,7%), respectively. There were seven (25%) cases of peritonitis in the balloon-type without-pexy group and 1 (0.5%) in the balloon-type with-pexy group, the latter being the only patient who died in the total number of patients (0.3%). Two (1%) patients of the balloon-type with-pexy group presented with gastrocolic fistula. The rest of the complications were minor. CONCLUSIONS: The most frequent complications associated with the administration of enteral nutrition through PRG were minor and the implementation of the balloon-type technique with pexy has led to a decrease in them.


Asunto(s)
Gastrostomía , Radiología , Humanos , Gastrostomía/efectos adversos , Gastrostomía/métodos , Estudios Retrospectivos , Centros de Atención Terciaria , Radiografía Intervencional/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...