1.
MAGMA ; 37(2): 295-305, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38216813

RESUMEN

OBJECTIVE: The excellent blood and fat suppression of stimulated echo acquisition mode (STEAM) can be combined with saturation recovery single-shot acquisition (SASHA) in a novel STEAM-SASHA sequence for right ventricular (RV) native T1 mapping. MATERIALS AND METHODS: STEAM-SASHA splits magnetization preparation over two cardiac cycles, nulling blood signal and allowing fat signal to decay. Breath-hold T1 mapping was performed in a T1 phantom and twice in 10 volunteers using STEAM-SASHA and a modified Look-Locker sequence at peak systole at 3T. T1 was measured in 3 RV regions, the septum and left ventricle (LV). RESULTS: In phantoms, MOLLI under-estimated while STEAM-SASHA over-estimated T1, on average by 3.0% and 7.0% respectively, although at typical 3T myocardial T1 (T1 > 1200 ms) STEAM-SASHA was more accurate. In volunteers, T1 was higher using STEAM-SASHA than MOLLI in the LV and septum (p = 0.03, p = 0.006, respectively), but lower in RV regions (p > 0.05). Inter-study, inter-observer and intra-observer coefficients of variation in all regions were < 15%. Blood suppression was excellent with STEAM-SASHA and noise floor effects were minimal. DISCUSSION: STEAM-SASHA provides accurate and reproducible T1 in the RV with excellent blood and fat suppression. STEAM-SASHA has potential to provide new insights into pathological changes in the RV in future studies.


Asunto(s)
Ventrículos Cardíacos , Interpretación de Imagen Asistida por Computador , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Miocardio/patología , Corazón/diagnóstico por imagen , Voluntarios Sanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética
2.
Int J Cardiovasc Imaging ; 40(2): 261-273, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38082073

RESUMEN

The electrocardiogram (ECG) signal is prone to distortions from gradient and radiofrequency interference and the magnetohydrodynamic effect during cardiovascular magnetic resonance imaging (CMR). Although Pilot Tone Cardiac (PTC) triggering has the potential to overcome these limitations, effectiveness across various CMR techniques has yet to be established. To evaluate the performance of PTC triggering in a comprehensive CMR exam. Fifteen volunteers and 20 patients were recruited at two centers. ECG triggered images were collected for comparison in a subset of sequences. The PTC trigger accuracy was evaluated against ECG in cine acquisitions. Two experienced readers scored image quality in PTC-triggered cine, late gadolinium enhancement (LGE), and T1- and T2-weighted dark-blood turbo spin echo (DB-TSE) images. Quantitative cardiac function, flow, and parametric mapping values obtained using PTC and ECG triggered sequences were compared. Breath-held segmented cine used for trigger timing analysis was collected in 15 volunteers and 14 patients. PTC calibration failed in three volunteers and one patient; ECG trigger recording failed in one patient. Out of 1987 total heartbeats, three mismatched trigger PTC-ECG pairs were found. Image quality scores showed no significant difference between PTC and ECG triggering. There was no significant difference found in quantitative measurements in volunteers. In patients, the only significant difference was found in post-contrast T1 (p = 0.04). ICC showed moderate to excellent agreement in all measurements. PTC performance was equivalent to ECG in terms of triggering consistency, image quality, and quantitative image measurements across multiple CMR applications.


Asunto(s)
Medios de Contraste , Gadolinio , Humanos , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética , Cafeína , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Cinemagnética
3.
MAGMA ; 37(2): 199-213, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38127221

RESUMEN

INTRODUCTION: Quality assurance (QA) of measurements derived from MRI can require complicated test phantoms. This work introduces a new QA concept using gradient and transmit RF recordings by a limited field camera (FC) to govern the previous Virtual Phantom (ViP) method. The purpose is to describe the first technical implementation of combined FC+ViP, and illustrate its performance in examples, including quantitative first-pass myocardial perfusion. MATERIALS AND METHODS: The new QA concept starts with a synthetic test object (STO) representing some arbitrary test input. Using recordings of the unmodified standard sequence by a gradient and RF waveform camera (FC), ViP calculates by Bloch simulation the continuous RF signal emitted by the STO during this sequence (hence FC+ViP). During nominally identical repetition of the sequence acquisition, ViP transmits the RF signal for scanner reception, reconstruction and any further parametric derivations by the unmodified standard scanner image reconstruction and analysis software. RESULTS: The scanner outputs were compared against the input STOs. CONCLUSION: First proof-of-principle was discussed and supported by correlation between scanner outputs and the input STO. The work makes no claim that its examples are valid QA methods. It concludes by proposing a new industrial standard for QA without the FC.


Asunto(s)
Imagen por Resonancia Magnética , Programas Informáticos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Simulación por Computador
4.
Res Sq ; 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37461505

RESUMEN

Background: The electrocardiogram (ECG) signal is prone to distortions from gradient and radiofrequency interference and the magnetohydrodynamic effect during cardiovascular magnetic resonance imaging (CMR). Although Pilot Tone Cardiac (PTC) triggering has the potential to overcome these limitations, effectiveness across various CMR techniques has yet to be established. Purpose: To evaluate the performance of PTC triggering in a comprehensive CMR exam. Methods: Fifteen volunteers and twenty patients were recruited at two centers. ECG triggered images were collected for comparison in a subset of sequences. The PTC trigger accuracy was evaluated against ECG in cine acquisitions. Two experienced readers scored image quality in PTC-triggered cine, late gadolinium enhancement (LGE), and T1- and T2-weighted dark-blood turbo spin echo (DB-TSE) images. Quantitative cardiac function, flow, and parametric mapping values obtained using PTC and ECG triggered sequences were compared. Results: Breath-held segmented cine used for trigger timing analysis was collected in 15 volunteers and 14 patients. PTC calibration failed in three volunteers and one patient; ECG trigger recording failed in one patient. Out of 1987 total heartbeats, three mismatched trigger PTC-ECG pairs were found. Image quality scores showed no significant difference between PTC and ECG triggering. There was no significant difference found in quantitative measurements in volunteers. In patients, the only significant difference was found in post-contrast T1 (p = 0.04). ICC showed moderate to excellent agreement in all measurements. Conclusion: PTC performance was equivalent to ECG in terms of triggering consistency, image quality, and quantitative image measurements across multiple CMR applications.

5.
MAGMA ; 36(6): 869-876, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37202654

RESUMEN

OBJECTIVES: Two-dimensional (2D) through-plane phase-contrast (PC) cine flow imaging assesses shunts and valve regurgitations in paediatric CMR and is considered the reference standard for Clinical quantification of blood Flow (COF). However, longer breath-holds (BH) can reduce compliance with possibly large respiratory manoeuvres altering flow. We hypothesize that reduced BH time by application of CS (Short BH quantification of Flow) (SBOF) retains accuracy while enabling faster, potentially more reliable flows. We investigate the variance between COF and SBOF cine flows. METHODS: Main pulmonary artery (MPA) and sinotubular junction (STJ) planes were acquired at 1.5 T in paediatric patients by COF and SBOF. RESULTS: 21 patients (mean age 13.9, 10-17y) were enrolled. The BH times were COF mean 11.7 s (range 8.4-20.9 s) vs SBOF mean 6.5 s (min 3.6-9.1 s). The differences and 95% CI between the COF and SBOF flows were LVSV -1.43 ± 13.6(ml/beat), LVCO 0.16 ± 1.35(l/min) and RVSV 2.95 ± 12.3(ml/beat), RVCO 0.27 ± 0.96(l/min), QP/QS were SV 0.04 ± 0.19, CO 0.02 ± 0.23. Variability between COF and SBOF did not exceed intrasession variation of COF. CONCLUSION: SBOF reduces breath-hold duration to 56% of COF. RV flow by SBOF was biased compared to COF. The variation (95% CI) between COF and SBOF was similar to the COF intrasession test-retest 95% CI.


Asunto(s)
Imagen por Resonancia Cinemagnética , Imagen por Resonancia Magnética , Humanos , Niño , Imagen por Resonancia Cinemagnética/métodos , Pulmón , Contencion de la Respiración , Espectroscopía de Resonancia Magnética , Reproducibilidad de los Resultados
6.
IEEE J Biomed Health Inform ; 27(10): 5134-5142, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35290192

RESUMEN

Synthetic digital twins based on medical data accelerate the acquisition, labelling and decision making procedure in digital healthcare. A core part of digital healthcare twins is model-based data synthesis, which permits the generation of realistic medical signals without requiring to cope with the modelling complexity of anatomical and biochemical phenomena producing them in reality. Unfortunately, algorithms for cardiac data synthesis have been so far scarcely studied in the literature. An important imaging modality in the cardiac examination is three-directional CINE multi-slice myocardial velocity mapping (3Dir MVM), which provides a quantitative assessment of cardiac motion in three orthogonal directions of the left ventricle. The long acquisition time and complex acquisition produce make it more urgent to produce synthetic digital twins of this imaging modality. In this study, we propose a hybrid deep learning (HDL) network, especially for synthetic 3Dir MVM data. Our algorithm is featured by a hybrid UNet and a Generative Adversarial Network with a foreground-background generation scheme. The experimental results show that from temporally down-sampled magnitude CINE images (six times), our proposed algorithm can still successfully synthesise high temporal resolution 3Dir MVM CMR data (PSNR=42.32) with precise left ventricle segmentation (DICE=0.92). These performance scores indicate that our proposed HDL algorithm can be implemented in real-world digital twins for myocardial velocity mapping data simulation. To the best of our knowledge, this work is the first one investigating digital twins of the 3Dir MVM CMR, which has shown great potential for improving the efficiency of clinical studies via synthesised cardiac data.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Cinemagnética , Humanos , Imagen por Resonancia Cinemagnética/métodos , Corazón/diagnóstico por imagen , Ventrículos Cardíacos , Velocidad del Flujo Sanguíneo , Imagen por Resonancia Magnética
7.
Magn Reson Imaging ; 98: 44-54, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36581215

RESUMEN

PURPOSE: Variable heart rate during single-cycle inversion-recovery Late Gadolinium-Enhanced (LGE) scanning degrades image quality, which can be mitigated using Variable Inversion Times (VTIs) in real-time response to R-R interval changes. We investigate in vivo and in simulations an extension of a single-cycle VTI method previously applied in 3D LGE imaging, that now fully models the longitudinal magnetisation (fmVTI). METHODS: The VTI and fmVTI methods were used to perform 3D LGE scans for 28 3D LGE patients, with qualitative image quality scores assigned for left atrial wall clarity and total ghosting. Accompanying simulations of numerical phantom images were assessed in terms of ghosting of normal myocardium, blood, and myocardial scar. RESULTS: The numerical simulations for fmVTI showed a significant decrease in blood ghosting (VTI: 410 ± 710, fmVTI: 68 ± 40, p < 0.0005) and scar ghosting (VTI: 830 ± 1300, fmVTI: 510 ± 730, p < 0.02). Despite this, there was no significant change in qualitative image quality scores, either for left atrial wall clarity (VTI: 2.0 ± 1.0, fmVTI: 1.8 ± 1.0, p > 0.1) or for total ghosting (VTI: 1.9 ± 1.0, fmVTI: 2.0 ± 1.0, p > 0.7). CONCLUSIONS: Simulations indicated reduced ghosting with the fmVTI method, due to reduced Mz variability in the blood signal. However, other sources of phase-encode ghosting and blurring appeared to dominate and obscure this finding in the patient studies available.


Asunto(s)
Fibrilación Atrial , Gadolinio , Humanos , Cicatriz , Medios de Contraste , Miocardio/patología , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos
8.
Int J Cardiovasc Imaging ; 38(11): 2413-2424, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36434343

RESUMEN

Cardiovascular magnetic resonance (CMR) derived ventricular volumes and function guide clinical decision-making for various cardiac pathologies. We aimed to evaluate the efficiency and clinical applicability of a commercially available artificial intelligence (AI) method for performing biventricular volumetric analysis. Three-hundred CMR studies (100 with normal CMR findings, 50 dilated cardiomyopathy, 50 hypertrophic cardiomyopathy, 50 ischaemic heart disease and 50 congenital or valvular heart disease) were randomly selected from database. Manual biventricular volumetric analysis (CMRtools) results were derived from clinical reports and automated volumetric analyses were performed using short axis volumetry AI function of CircleCVI42 v5.12 software. For 20 studies, a combined method of manually adjusted AI contours was tested and all three methods were timed. Clinicians` confidence in AI method was assessed using an online survey. Although agreement was better for left ventricle than right ventricle, AI analysis results were comparable to manual method. Manual adjustment of AI contours further improved agreement: within subject coefficient of variation decreased from 5.0% to 4.5% for left ventricular ejection fraction (EF) and from 9.9% to 7.1% for right ventricular EF. Twenty manual analyses were performed in 250 min 12 s whereas same task took 5 min 48 s using AI method. Clinicians were open to adopt AI but concerns about accuracy and validity were raised. The AI method provides clinically valid outcomes and saves significant time. To address concerns raised by survey participants and overcome shortcomings of the automated myocardial segmentation, visual assessment of contours and performing manual corrections where necessary appears to be a practical approach.


Asunto(s)
Inteligencia Artificial , Función Ventricular Izquierda , Humanos , Volumen Sistólico , Valor Predictivo de las Pruebas , Espectroscopía de Resonancia Magnética
9.
Front Bioeng Biotechnol ; 10: 962687, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36017352

RESUMEN

The patchy distribution of atherosclerosis within the arterial system is consistent with a controlling influence of hemodynamic wall shear stress (WSS). Patterns of low, oscillatory and transverse WSS have been invoked to explain the distribution of disease in the aorta. Disease of coronary arteries has greater clinical importance but blood flow in these vessels may be complicated by their movement during the cardiac cycle. Previous studies have shown that time average WSS is little affected by the dynamic geometry, and that oscillatory shear is influenced more. Here we additionally investigate effects on transverse WSS. We also investigate the influence of non-Newtonian blood rheology as it can influence vortical structure, on which transverse WSS depends; Carreau-Yasuda models were used. WSS metrics were derived from numerical simulations of blood flow in a model of a moving right coronary artery which, together with a subject-specific inflow waveform, was obtained by MR imaging of a healthy human subject in a previous study. The results confirmed that time average WSS was little affected by dynamic motion and that oscillatory WSS was more affected. They additionally showed that transverse WSS and its non-dimensional analogue, the Cross Flow Index, were affected still further. This appeared to reflect time-varying vortical structures caused by the changes in curvature. The influence of non-Newtonian rheology was significant with some physiologically realistic parameter values, and hence may be important in certain subjects. Dynamic geometry and non-Newtonian rheology should be incorporated into models designed to produce maps of transverse WSS in coronary arteries.

10.
Radiol Cardiothorac Imaging ; 4(3): e210235, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35833165

RESUMEN

Cardiac MRI has become a widely accepted standard for anatomic and functional assessment of complex Fontan physiology, because it is noninvasive and suitable for comprehensive follow-up evaluation after Fontan completion. The use of cardiac MRI in pediatric and adult patients after completion of the Fontan procedure are described, and a practical and experience-based cardiac MRI protocol for evaluating these patients is provided. The current approach and study protocol in use at the authors' institution are presented, which address technical considerations concerning sequences, planning, and optimal image acquisition in patients with Fontan circulation. Additionally, for each sequence, the information that can be obtained and guidance on how to integrate it into clinical decision-making is discussed. Keywords: Pediatrics, MRI, MRI Functional Imaging, Heart, Congenital © RSNA, 2022.

11.
Eur Radiol ; 32(4): 2581-2593, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34713331

RESUMEN

OBJECTIVES: Cardiovascular magnetic resonance (CMR) cine imaging by compressed sensing (CS) is promising for patients unable to tolerate long breath-holding. However, the need for a steady-state free-precession (SSFP) preparation cardiac cycle for each slice extends the breath-hold duration (e.g. for 10 slices, 20 cardiac cycles) to an impractical length. We investigated a method reducing breath-hold duration by half and assessed its reliability for biventricular volume analysis in a pediatric population. METHODS: Fifty-five consecutive pediatric patients (median age 12 years, range 7-17) referred for assessment of congenital heart disease or cardiomyopathy were included. Conventional multiple breath-hold SSFP short-axis (SAX) stack cines served as the reference. Real-time CS SSFP cines were applied without the steady-state preparation cycle preceding each SAX cine slice, accepting the limitation of omitting late diastole. The total acquisition time was 1 RR interval/slice. Volumetric analysis was performed for conventional and "single-cycle-stack-advance" (SCSA) cine stacks. RESULTS: Bland-Altman analyses [bias (limits of agreement)] showed good agreement in left ventricular (LV) end-diastolic volume (EDV) [3.6 mL (- 5.8, 12.9)], LV end-systolic volume (ESV) [1.3 mL (- 6.0, 8.6)], LV ejection fraction (EF) [0.1% (- 4.9, 5.1)], right ventricular (RV) EDV [3.5 mL (- 3.34, 10.0)], RV ESV [- 0.23 mL (- 7.4, 6.9)], and RV EF [1.70%, (- 3.7, 7.1)] with a trend toward underestimating LV and RV EDVs with the SCSA method. Image quality was comparable for both methods (p = 0.37). CONCLUSIONS: LV and RV volumetric parameters agreed well between the SCSA and the conventional sequences. The SCSA method halves the breath-hold duration of the commercially available CS sequence and is a reliable alternative for volumetric analysis in a pediatric population. KEY POINTS: • Compressed sensing is a promising accelerated cardiovascular magnetic resonance imaging technique. • We omitted the steady-state preparation cardiac cycle preceding each cine slice in compressed sensing and achieved an acquisition speed of 1 RR interval/slice. • This modification called "single-cycle-stack-advance" enabled the acquisition of an entire short-axis cine stack in a single short breath hold. • When tested in a pediatric patient group, the left and right ventricular volumetric parameters agreed well between the "single-cycle-stack-advance" and the conventional sequences.


Asunto(s)
Contencion de la Respiración , Imagen por Resonancia Cinemagnética , Adolescente , Niño , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Reproducibilidad de los Resultados , Volumen Sistólico , Función Ventricular Izquierda
12.
Magn Reson Imaging ; 81: 94-100, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34147599

RESUMEN

A technical note is presented on the slab-direction aliasing of 3D imaging, introducing a simple methodology for determining the minimised duration of low flip-angle sinc radiofrequency (RF) excitation pulses, with respect to a required slab profile accuracy. The various interdependent factors affected in modifying an RF pulse duration are considered and analysed in the context of a new metric for quantifying the levels of permitted slab-aliasing. A general framework is presented for the selection of standard sinc RF excitation pulses with system-minimised durations, as well as their analysis and validation, and a demonstration of this methodology is performed for an example requirement and scanner. This methodology enables implementation of standard (vendor-generated) RF pulses with minimised duration for a required application, with high confidence in their operational reliability. Parts of such a methodology may also in theory be extended to more advanced RF pulse designs.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Algoritmos , Frecuencia Cardíaca , Imagenología Tridimensional , Fantasmas de Imagen , Reproducibilidad de los Resultados
14.
J Cardiovasc Magn Reson ; 23(1): 26, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33685501

RESUMEN

INTRODUCTION: Heart failure (HF) in hypertrophic cardiomyopathy (HCM) is associated with high morbidity and mortality. Predictors of HF, in particular the role of myocardial fibrosis and microvascular ischemia remain unclear. We assessed the predictive value of cardiovascular magnetic resonance (CMR) for development of HF in HCM in an observational cohort study. METHODS: Serial patients with HCM underwent CMR, including adenosine first-pass perfusion, left atrial (LA) and left ventricular (LV) volumes indexed to body surface area (i) and late gadolinium enhancement (%LGE- as a % of total myocardial mass). We used a composite endpoint of HF death, cardiac transplantation, and progression to NYHA class III/IV. RESULTS: A total of 543 patients with HCM underwent CMR, of whom 94 met the composite endpoint at baseline. The remaining 449 patients were followed for a median of 5.6 years. Thirty nine patients (8.7%) reached the composite endpoint of HF death (n = 7), cardiac transplantation (n = 2) and progression to NYHA class III/IV (n = 20). The annual incidence of HF was 2.0 per 100 person-years, 95% CI (1.6-2.6). Age, previous non-sustained ventricular tachycardia, LV end-systolic volume indexed to body surface area (LVESVI), LA volume index ; LV ejection fraction, %LGE and presence of mitral regurgitation were significant univariable predictors of HF, with LVESVI (Hazard ratio (HR) 1.44, 95% confidence interval (95% CI) 1.16-1.78, p = 0.001), %LGE per 10% (HR 1.44, 95%CI 1.14-1.82, p = 0.002) age (HR 1.37, 95% CI 1.06-1.77, p = 0.02) and mitral regurgitation (HR 2.6, p = 0.02) remaining independently predictive on multivariable analysis. The presence or extent of inducible perfusion defect assessed using a visual score did not predict outcome (p = 0.16, p = 0.27 respectively). DISCUSSION: The annual incidence of HF in a contemporary ambulatory HCM population undergoing CMR is low. Myocardial fibrosis and LVESVI are strongly predictive of future HF, however CMR visual assessment of myocardial perfusion was not.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Circulación Coronaria , Insuficiencia Cardíaca/etiología , Imagen por Resonancia Magnética , Microcirculación , Imagen de Perfusión Miocárdica , Miocardio/patología , Adulto , Anciano , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/patología , Cardiomiopatía Hipertrófica/fisiopatología , Progresión de la Enfermedad , Femenino , Fibrosis , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda
15.
Diagnostics (Basel) ; 11(2)2021 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-33669747

RESUMEN

Three-directional cine multi-slice left ventricular myocardial velocity mapping (3Dir MVM) is a cardiac magnetic resonance (CMR) technique that allows the assessment of cardiac motion in three orthogonal directions. Accurate and reproducible delineation of the myocardium is crucial for accurate analysis of peak systolic and diastolic myocardial velocities. In addition to the conventionally available magnitude CMR data, 3Dir MVM also provides three orthogonal phase velocity mapping datasets, which are used to generate velocity maps. These velocity maps may also be used to facilitate and improve the myocardial delineation. Based on the success of deep learning in medical image processing, we propose a novel fast and automated framework that improves the standard U-Net-based methods on these CMR multi-channel data (magnitude and phase velocity mapping) by cross-channel fusion with an attention module and the shape information-based post-processing to achieve accurate delineation of both epicardial and endocardial contours. To evaluate the results, we employ the widely used Dice Scores and the quantification of myocardial longitudinal peak velocities. Our proposed network trained with multi-channel data shows superior performance compared to standard U-Net-based networks trained on single-channel data. The obtained results are promising and provide compelling evidence for the design and application of our multi-channel image analysis of the 3Dir MVM CMR data.

16.
Eur Heart J Case Rep ; 4(3): 1-4, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33043238

RESUMEN

BACKGROUND: A 53-year-old female with dyspnoea and atypical chest pain. Her electrocardiogram demonstrated a left bundle branch block, transthoracic echocardiogram demonstrated a mildly impaired left ventricle ejection fraction, and coronary angiogram revealed unobstructed coronary arteries. She was referred for cardiovascular magnetic resonance (CMR) for structural and functional assessment. Her imaging revealed an unexpected finding of an off-resonance artefact within the ventricle wall. This material was secondary to a ferromagnetic material. CASE SUMMARY: Chest X ray and computer tomography confirmed a needle-shaped structure in the ventricle wall. Understanding the basis of this off-resonance artefact aided in a new diagnosis, raised questions on the origin of the material, patient safety, and implementation of corrective strategies to optimize image acquisition. DISCUSSION: The continued development of CMR is revolutionizing our ability to establish diagnosis and guide patient treatment. The CMR sequences can be prone to artefact. This case highlights the importance of understanding the basis of CMR artefacts.

17.
Am J Cardiol ; 136: 140-148, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-32950468

RESUMEN

Atrial fibrillation (AF) in hypertrophic cardiomyopathy (HC) is associated with significant symptomatic deterioration, heart failure, and thromboembolic disease. There is a need for better mechanistic insight and improved identification of at risk patients. We used cardiovascular magnetic resonance (CMR) to assess predictors of AF in HC, in particular the role of myocardial fibrosis. Consecutive patients with HC referred for CMR 2003 to 2013 were prospectively enrolled. CMR parameters including left ventricular volumes, presence and percentage of late gadolinium enhancement in the left ventricle (%LGE) and left atrial volume index (LAVi) were measured. Overall, 377 patients were recruited (age 62 ± 14 years, 73% men). Sixty-two patients (16%) developed new-onset AF during a median follow up of 4.5 (interquartile range 2.9 to 6.0) years. Multivariable analysis revealed %LGE (hazard ratio [HR] 1.3 per 10% (confidence interval: 1.0 to 1.5; p = 0.02), LAVi (HR 1.4 per 10 mL/m2[1.2 to 1.5; p < 0.001]), age at HC diagnosis, nonsustained ventricular tachycardia and diabetes to be independent predictors of AF. We constructed a simple risk prediction score for future AF based on the multivariable model with a Harrell's C-statistic of 0.73. In conclusion, the extent of ventricular fibrosis and LA volume independently predicted AF in patients with HC. This finding suggests a mechanistic relation between fibrosis and future AF in HC. CMR with quantification of fibrosis has incremental value over LV and LA measurements in risk stratification for AF. A risk prediction score may be used to identify patients at high risk of future AF who may benefit from more intensive rhythm monitoring and a lower threshold for oral anticoagulation.


Asunto(s)
Fibrilación Atrial/etiología , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Imagen por Resonancia Magnética , Anciano , Femenino , Fibrosis , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Valor Predictivo de las Pruebas , Estudios Prospectivos
18.
J Cardiovasc Magn Reson ; 22(1): 31, 2020 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-32375896

RESUMEN

BACKGROUND: The T1 Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T1 mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformité Européenne (CE) regulatory clearance. We report T1 measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B0 and B1, and "reference" slow T1 testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T1 mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T1 mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T1 was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T1 variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B0 and B1 homogenous, and "reference" T1 stable compared to baseline (% change at 1.5 T, 1.95 ± 1.39%; 3 T, 2.22 ± 1.44%). Per degrees Celsius, 1.5 T, T1 (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T1 times with "reference" T1 was similar across Siemens and Philips CMR systems at both field strengths (adjusted R2 ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T1 was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T1 mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T1 across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T1 mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T1 times for clinical use, although temperature correction is required for native T1 tubes at least.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/normas , Fantasmas de Imagen/normas , Consenso , Humanos , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
19.
Glob Cardiol Sci Pract ; 2020(3): e202038, 2020 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-33598498

RESUMEN

Objective: Myocardial first-pass perfusion imaging with MRI is well-established clinically. However, it is potentially weakened by limited myocardial coverage compared to nuclear medicine. Clinical evaluations of whole-heart MRI perfusion by 3D methods, while promising, have to date had the limit of breathhold requirements at stress. This work aims to develop a new free-breathing 3D myocardial perfusion method, and to test its performance in a small patient population. Methods: This work required tolerance to respiratory motion for stress investigations, and therefore employed a "stack-of-stars" hybrid Cartesian-radial MRI acquisition method. The MRI sequence was highly optimised for rapid acquisition and combined with a compressed sensing reconstruction. Stress and rest datasets were acquired in four healthy volunteers, and in six patients with coronary artery disease (CAD), which were compared against clinical reference information. Results: This free-breathing method produced datasets that appeared consistent with clinical reference data in detecting moderate-to-strong induced perfusion abnormalities. However, the majority of the mild defects identified clinically were not detected by the method, potentially due to the presence of transient myocardial artefacts present in the images. Discussion: The feasibility of detecting CAD using this 3D first-pass perfusion sequence during free-breathing is demonstrated. Good agreement on typical moderate-to-strong CAD cases is promising, however, questions still remain on the sensitivity of the technique to milder cases.

20.
Magn Reson Med ; 83(6): 1949-1963, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31670858

RESUMEN

PURPOSE: The purpose of this study was to further develop and combine several innovative sequence designs to achieve quantitative 3D myocardial perfusion. These developments include an optimized 3D stack-of-stars readout (150 ms per beat), efficient acquisition of a 2D arterial input function, tailored saturation pulse design, and potential whole heart coverage during quantitative stress perfusion. THEORY AND METHODS: All studies were performed free-breathing on a Prisma 3T MRI scanner. Phantom validation was used to verify sequence accuracy. A total of 21 subjects (3 patients with known disease) were scanned, 12 with a rest only protocol and 9 with both stress (regadenoson) and rest protocols. First pass quantitative perfusion was performed with gadoteridol (0.075 mmol/kg). RESULTS: Implementation and quantitative perfusion results are shown for healthy subjects and subjects with known coronary disease. Average rest perfusion for the 15 included healthy subjects was 0.79 ± 0.19 mL/g/min, the average stress perfusion for 6 healthy subject studies was 2.44 ± 0.61 mL/g/min, and the average global myocardial perfusion reserve ratio for 6 healthy subjects was 3.10 ± 0.24. Perfusion deficits for 3 patients with ischemia are shown. Average resting heart rate was 59 ± 7 bpm and the average stress heart rate was 81 ± 10 bpm. CONCLUSION: This work demonstrates that a quantitative 3D myocardial perfusion sequence with the acquisition of a 2D arterial input function is feasible at high stress heart rates such as during stress. T1 values and gadolinium concentrations of the sequence match the reference standard well in a phantom, and myocardial rest and stress perfusion and myocardial perfusion reserve values are consistent with those published in literature.


Asunto(s)
Circulación Coronaria , Imagen de Perfusión Miocárdica , Algoritmos , Humanos , Imagen por Resonancia Magnética , Perfusión , Fantasmas de Imagen