Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Acta Orthop Belg ; 90(1): 5-10, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38669642

RESUMEN

The aim of the study is to determine the revision ratio after implantation of the femoral neck system (FNS) for the treatment of femoral neck fractures. A retrospective single center cohort analysis with a total of 71 patients who underwent the implantation of the FNS between December 2019 and December 2021, was performed. 31 males and 40 females were included. There was no exclusion based on BMI, ASA score, Garden classification or Pauwels classification. Primary outcome was the revision rate after FNS implantation. Secondary outcomes comprise the reason for revision surgery as well as the time toward revision surgery and the 30-day mortality. The revision ratio was 11 out of 71 patients (15.5%) with an average time to revision surgery of 10 months. Most common reason for revision was avascular necrosis (AVN) in 45.5%. Other reasons for revision surgery were implant failure due to a secondary fall on to the hip with the FNS implant in place, cut-out, cut-through and malunion in respectively 27.3%, 9%, 9% and 9% of the revision patients. The one- hole plate was used in 72% of the patients. Mean follow-up was 18.07 months (range 6-30 months). Full weight bearing instruction was given to 85.9% of the patients. Partial weight bearing in 14.1% of the patients. In conclusion, the FNS has similar revision ratio when used for femoral neck fractures compared to cannulated screw fixation in literature. The predominant reason for revision is AVN and implant failure with no difference between the use of the one- or-two-hole plate in this study.


Asunto(s)
Fracturas del Cuello Femoral , Reoperación , Humanos , Masculino , Femenino , Estudios Retrospectivos , Reoperación/estadística & datos numéricos , Fracturas del Cuello Femoral/cirugía , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Falla de Prótesis , Prótesis de Cadera , Fijación Interna de Fracturas/métodos
2.
Acta Orthop Belg ; 89(4): 595-602, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38205747

RESUMEN

The intraoperative measurement of the femoral version (FV) has gained attention in wake of an optimised combined version (CV) philosophy. Whereas some data is available utilising different approaches, to our belief this study provides the first in vivo FV data in DA-THA using the MAKO™ robot. To improve the accuracy of the femoral stem version in DA-THA, we want to ask the following question: How effectively can we reproduce the native femoral version in DA- THA using the MAKO™ robot? The first 125 total hip cases through DAA with the use of the combined anteversion concept and the help of the MAKO™ robot from a single institution, single surgeon from January 2020 to July 2021 were retrospectively analysed. The native version (NV) and broach version (BV) were determined with the use of the MAKO™ preoperative computed tomography planning software. The data of the NV and BV of 115 withheld patients was normally distributed. The native femoral version ranged from -12° till 33° (mean 7,8° +/- 8,1) and the broach version ranged from -18° till 43° (mean 8,2° +/- 9,9). The Pearson correlation coefficient between the NV and BV was 0,78. The native femoral version can be reproduced by broaching the proximal femur, in a robotically implanted direct anterior cementless THA, with 78% effectiveness. Stem placement seemed to be more precise with growing experience, however this appeared not to be significant.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Cuello Femoral/diagnóstico por imagen , Cuello Femoral/cirugía , Antivirales , Reproducibilidad de los Resultados , Estudios Retrospectivos