Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Radiat Res ; 64(2): 471-479, 2023 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-36634350

RESUMEN

The purpose of the present study is to evaluate the effect of curcumin as a natural compound against radiation induced γ-foci and stable chromosome aberrations. Whole blood samples form three human volunteers were pretreated with curcumin at different concentrations (0.5, 10, 20 and 100 µg/ml). After 1-hour incubation, the lymphocytes were exposed to γ-rays (0.05, 0.5, 1 and 2 Gy). Radiation induced changes in cells were quantified using γ-H2AX/53BP1 assay and FISH analysis. Our results have shown that curcumin significantly reduced the frequency of both γ-foci and translocations. We found concentration-dependent increase of curcumin protective effect on γ-H2AX/53BP1 foci formation at all radiation doses. Concerning the translocations, after 0.05 and 0.5 Gy γ-rays the values of genomic frequencies are comparable within each dose and we did not observe any impact of curcumin. The most protective effect after 1 Gy exposure was found at 100 µg/ml curcumin. At 2 Gy irradiation, the maximum protection was achieved at 0.5 and 10 µg/ml of curcumin. Concentrations of 20 and 100 µg/ml also prevent lymphocytes but to less extent. Our in vitro study indicates radioprotective efficacy of curcumin against γ-ray induced damages in human lymphocytes. This observation suggests that curcumin may play a role to protect patients undergoing radiological procedures.


Asunto(s)
Curcumina , Histonas , Humanos , Curcumina/farmacología , Dosis de Radiación , Linfocitos , Aberraciones Cromosómicas , Translocación Genética , Relación Dosis-Respuesta en la Radiación , Rayos gamma
2.
Int J Radiat Biol ; 93(1): 99-109, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27437830

RESUMEN

PURPOSE: RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. MATERIALS AND METHODS: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. RESULTS: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. CONCLUSIONS: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.


Asunto(s)
Bioensayo/métodos , Planificación en Desastres/métodos , Laboratorios , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Administración de la Seguridad/métodos , Unión Europea , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Integración de Sistemas
3.
Int J Radiat Biol ; 93(1): 48-57, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27813725

RESUMEN

PURPOSE: Dose assessment intercomparisons within the RENEB network were performed for triage biodosimetry analyzing G0-lymphocyte PCC for harmonization, standardization and optimization of the PCC assay. MATERIALS AND METHODS: Comparative analysis among different partners for dose assessment included shipment of PCC-slides and captured images to construct dose-response curves for up to 6 Gy γ-rays. Accident simulation exercises were performed to assess the suitability of the PCC assay by detecting speed of analysis and minimum number of cells required for categorization of potentially exposed individuals. RESULTS: Calibration data based on Giemsa-stained fragments in excess of 46 PCC were obtained by different partners using galleries of PCC images for each dose-point. Mean values derived from all scores yielded a linear dose-response with approximately 4 excess-fragments/cell/Gy. To unify scoring criteria, exercises were carried out using coded PCC-slides and/or coded irradiated blood samples. Analysis of samples received 24 h post-exposure was successfully performed using Giemsa staining (1 excess-fragment/cell/Gy) or centromere/telomere FISH-staining for dicentrics. CONCLUSIONS: Dose assessments by RENEB partners using appropriate calibration curves were mostly in good agreement. The PCC assay is quick and reliable for whole- or partial-body triage biodosimetry by scoring excess-fragments or dicentrics in G0-lymphocytes. Particularly, analysis of Giemsa-stained excess PCC-fragments is simple, inexpensive and its automation could increase throughput and scoring objectivity of the PCC assay.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas/efectos de la radiación , Pruebas de Micronúcleos/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Bioensayo/normas , Europa (Continente) , Humanos , Linfocitos/citología , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Fase de Descanso del Ciclo Celular/genética , Fase de Descanso del Ciclo Celular/efectos de la radiación , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...