Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Biomech ; 115: 110158, 2021 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-33360181

RESUMEN

Coronary artery disease (CAD), one of the leading causes of death globally, occurs due to the growth of atherosclerotic plaques in the coronary arteries, causing lesions which restrict the flow of blood to the myocardium. Percutaneous transluminal coronary angioplasty (PTCA), including balloon angioplasty and coronary stent deployment is a standard clinical invasive treatment for CAD. Coronary stents are delivered using a balloon catheter inserted across the lesion. The balloon is inflated to a nominal pressure, opening the occluded artery, deploying the stent and improving the flow of blood to the myocardium. All stent manufacturers have to perform standard in vitro mechanical testing under different physiological conditions. In this study, partially and fully bioresorbable vascular scaffolds (BVS) from Boston Scientific Limited have been examined in vitro and in silico for three different test methods: inflation, radial compression and crush resistance. We formulated a material model for poly-L-lactic acid (PLLA) and implemented it into our in-house software tool. A comparison of the different experimental results is presented in the form of graphs showing displacement-force curves, diameter - load curves or diameter - pressure curves. There is a strong correlation between simulation and real experiments with a coefficient of determination (R2) > 0.99 and a correlation coefficient (R) > 0.99. This preliminary study has shown that in-silico tests can mimic the applicable ISO standards for mechanical in vitro stent testing, providing the opportunity to use data generated using in-silico testing to partially or fully replacing the mechanical testing required for regulatory submission.


Asunto(s)
Angioplastia Coronaria con Balón , Stents Liberadores de Fármacos , Implantes Absorbibles , Simulación por Computador , Diseño de Prótesis , Stents , Resultado del Tratamiento
2.
Front Med Technol ; 3: 724062, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35047953

RESUMEN

Bioresorbable vascular scaffolds (BVS), made either from polymers or from metals, are promising materials for treating coronary artery disease through the processes of percutaneous transluminal coronary angioplasty. Despite the opinion that bioresorbable polymers are more promising for coronary stents, their long-term advantages over metallic alloys have not yet been demonstrated. The development of new polymer-based BVS or optimization of the existing ones requires engineers to perform many very expensive mechanical tests to identify optimal structural geometry and material characteristics. in silico mechanical testing opens the possibility for a fast and low-cost process of analysis of all the mechanical characteristics and also provides the possibility to compare two or more competing designs. In this study, we used a recently introduced material model of poly-l-lactic acid (PLLA) fully bioresorbable vascular scaffold and recently empowered numerical InSilc platform to perform in silico mechanicals tests of two different stent designs with different material and geometrical characteristics. The result of inflation, radial compression, three-point bending, and two-plate crush tests shows that numerical procedures with true experimental constitutive relationships could provide reliable conclusions and a significant contribution to the optimization and design of bioresorbable polymer-based stents.

3.
Artículo en Inglés | MEDLINE | ID: mdl-31921800

RESUMEN

Mass transport represents the most fundamental process in living organisms. It includes delivery of nutrients, oxygen, drugs, and other substances from the vascular system to tissue and transport of waste and other products from cells back to vascular and lymphatic network and organs. Furthermore, movement is achieved by mechanical forces generated by muscles in coordination with the nervous system. The signals coming from the brain, which have the character of electrical waves, produce activation within muscle cells. Therefore, from a physics perspective, there exist a number of physical fields within the body, such as velocities of transport, pressures, concentrations of substances, and electrical potential, which is directly coupled to biochemical processes of transforming the chemical into mechanical energy and further internal forces for motion. The overall problems of mass transport and electrophysiology coupled to mechanics can be investigated theoretically by developing appropriate computational models. Due to the enormous complexity of the biological system, it would be almost impossible to establish a detailed computational model for the physical fields related to mass transport, electrophysiology, and coupled fields. To make computational models feasible for applications, we here summarize a concept of smeared physical fields, with coupling among them, and muscle mechanics, which includes dependence on the electrical potential. Accuracy of the smeared computational models, also with coupling to muscle mechanics, is illustrated with simple example, while their applicability is demonstrated on a liver model with tumors present. The last example shows that the introduced methodology is applicable to large biological systems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...