Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Radiol Cardiothorac Imaging ; 6(3): e230177, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38722232

RESUMEN

Purpose To develop a deep learning model for increasing cardiac cine frame rate while maintaining spatial resolution and scan time. Materials and Methods A transformer-based model was trained and tested on a retrospective sample of cine images from 5840 patients (mean age, 55 years ± 19 [SD]; 3527 male patients) referred for clinical cardiac MRI from 2003 to 2021 at nine centers; images were acquired using 1.5- and 3-T scanners from three vendors. Data from three centers were used for training and testing (4:1 ratio). The remaining data were used for external testing. Cines with downsampled frame rates were restored using linear, bicubic, and model-based interpolation. The root mean square error between interpolated and original cine images was modeled using ordinary least squares regression. In a prospective study of 49 participants referred for clinical cardiac MRI (mean age, 56 years ± 13; 25 male participants) and 12 healthy participants (mean age, 51 years ± 16; eight male participants), the model was applied to cines acquired at 25 frames per second (fps), thereby doubling the frame rate, and these interpolated cines were compared with actual 50-fps cines. The preference of two readers based on perceived temporal smoothness and image quality was evaluated using a noninferiority margin of 10%. Results The model generated artifact-free interpolated images. Ordinary least squares regression analysis accounting for vendor and field strength showed lower error (P < .001) with model-based interpolation compared with linear and bicubic interpolation in internal and external test sets. The highest proportion of reader choices was "no preference" (84 of 122) between actual and interpolated 50-fps cines. The 90% CI for the difference between reader proportions favoring collected (15 of 122) and interpolated (23 of 122) high-frame-rate cines was -0.01 to 0.14, indicating noninferiority. Conclusion A transformer-based deep learning model increased cardiac cine frame rates while preserving both spatial resolution and scan time, resulting in images with quality comparable to that of images obtained at actual high frame rates. Keywords: Functional MRI, Heart, Cardiac, Deep Learning, High Frame Rate Supplemental material is available for this article. © RSNA, 2024.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Cinemagnética , Humanos , Masculino , Imagen por Resonancia Cinemagnética/métodos , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Estudios Retrospectivos , Corazón/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos
2.
J Magn Reson Imaging ; 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38240166

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) intervention is an established prophylactic measure. Identifying high-benefit patients poses challenges. PURPOSE: To assess the prognostic value of cardiac magnetic resonance imaging (MRI) parameters including myocardial deformation for risk stratification of ICD intervention in non-ischemic cardiomyopathy (NICM) while accounting for competing mortality risk. STUDY TYPE: Retrospective and prospective. POPULATION: One hundred and fifty-nine NICM patients eligible for primary ICD (117 male, 54 ± 13 years) and 49 control subjects (38 male, 53 ± 5 years). FIELD STRENGTH/SEQUENCE: Balanced steady state free precession (bSSFP) and three-dimensional phase-sensitive inversion-recovery late gadolinium enhancement (LGE) sequences at 1.5 T or 3 T. ASSESSMENT: Patients underwent MRI before ICD implantation and were followed up. Functional parameters, left ventricular global radial, circumferential and longitudinal strain, right ventricular free wall longitudinal strain (RV FWLS) and left atrial strain were measured (Circle, cvi42). LGE presence was assessed visually. The primary endpoint was appropriate ICD intervention. Models were developed to determine outcome, with and without accounting for competing risk (non-sudden cardiac death), and compared to a baseline model including LGE and clinical features. STATISTICAL TESTS: Wilcoxon non-parametric test, Cox's proportional hazards regression, Fine-Gray competing risk model, and cumulative incidence functions. Harrell's c statistic was used for model selection. A P value <0.05 was considered statistically significant. RESULTS: Follow-up duration was 1176 ± 960 days (median: 896). Twenty-six patients (16%) met the primary endpoint. RV FWLS demonstrated a significant difference between patients with and without events (-12.5% ± 5 vs. -16.4% ± 5.5). Univariable analyses showed LGE and RV FWLS were significantly associated with outcome (LGE: hazard ratio [HR] = 3.69, 95% CI = 1.28-10.62; RV FWLS: HR = 2.04, 95% CI = 1.30-3.22). RV FWLS significantly improved the prognostic value of baseline model and remained significant in multivariable analysis, accounting for competing risk (HR = 1.73, 95% CI = 1.12-2.66). DATA CONCLUSIONS: In NICM, RV FWLS may provide additional predictive value for predicting appropriate ICD intervention. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 5.

3.
J Cardiovasc Magn Reson ; 25(1): 56, 2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37784153

RESUMEN

BACKGROUND: Exercise cardiovascular magnetic resonance (Ex-CMR) myocardial tagging would enable quantification of myocardial deformation after exercise. However, current electrocardiogram (ECG)-segmented sequences are limited for Ex-CMR. METHODS: We developed a highly accelerated balanced steady-state free-precession real-time tagging technique for 3 T. A 12-fold acceleration was achieved using incoherent sixfold random Cartesian sampling, twofold truncated outer phase encoding, and a deep learning resolution enhancement model. The technique was tested in two prospective studies. In a rest study of 27 patients referred for clinical CMR and 19 healthy subjects, a set of ECG-segmented for comparison and two sets of real-time tagging images for repeatability assessment were collected in 2-chamber and short-axis views with spatiotemporal resolution 2.0 × 2.0 mm2 and 29 ms. In an Ex-CMR study of 26 patients with known or suspected cardiac disease and 23 healthy subjects, real-time images were collected before and after exercise. Deformation was quantified using measures of short-axis global circumferential strain (GCS). Two experienced CMR readers evaluated the image quality of all real-time data pooled from both studies using a 4-point Likert scale for tagline quality (1-excellent; 2-good; 3-moderate; 4-poor) and artifact level (1-none; 2-minimal; 3-moderate; 4-significant). Statistical evaluation included Pearson correlation coefficient (r), intraclass correlation coefficient (ICC), and coefficient of variation (CoV). RESULTS: In the rest study, deformation was successfully quantified in 90% of cases. There was a good correlation (r = 0.71) between ECG-segmented and real-time measures of GCS, and repeatability was good to excellent (ICC = 0.86 [0.71, 0.94]) with a CoV of 4.7%. In the Ex-CMR study, deformation was successfully quantified in 96% of subjects pre-exercise and 84% of subjects post-exercise. Short-axis and 2-chamber tagline quality were 1.6 ± 0.7 and 1.9 ± 0.8 at rest and 1.9 ± 0.7 and 2.5 ± 0.8 after exercise, respectively. Short-axis and 2-chamber artifact level was 1.2 ± 0.5 and 1.4 ± 0.7 at rest and 1.3 ± 0.6 and 1.5 ± 0.8 post-exercise, respectively. CONCLUSION: We developed a highly accelerated real-time tagging technique and demonstrated its potential for Ex-CMR quantification of myocardial deformation. Further studies are needed to assess the clinical utility of our technique.


Asunto(s)
Corazón , Imagen por Resonancia Cinemagnética , Humanos , Estudios Prospectivos , Imagen por Resonancia Cinemagnética/métodos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Espectroscopía de Resonancia Magnética , Función Ventricular Izquierda
4.
Radiology ; 307(3): e222239, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36943075

RESUMEN

Background Scar burden with late gadolinium enhancement (LGE) cardiac MRI (CMR) predicts arrhythmic events in patients with postinfarction in single-center studies. However, LGE analysis requires experienced human observers, is time consuming, and introduces variability. Purpose To test whether postinfarct scar with LGE CMR can be quantified fully automatically by machines and to compare the ability of LGE CMR scar analyzed by humans and machines to predict arrhythmic events. Materials and Methods This study is a retrospective analysis of the multicenter, multivendor CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry. Patients with chronic heart failure, echocardiographic left ventricular ejection fraction (LVEF) of less than 50%, and LGE CMR were recruited (from January 2015 through December 2020). In the current study, only patients with ischemic cardiomyopathy were included. Quantification of total, dense, and nondense scars was carried out by two experienced readers or a Ternaus network, trained and tested with LGE images of 515 and 246 patients, respectively. Univariable and multivariable Cox analyses were used to assess patient and cardiac characteristics associated with a major adverse cardiac event (MACE). Area under the receiver operating characteristic curve (AUC) was used to compare model performances. Results In 761 patients (mean age, 65 years ± 11, 671 men), 83 MACEs occurred. With use of the testing group, univariable Cox-analysis found New York Heart Association class, left ventricle volume and/or function parameters (by echocardiography or CMR), guideline criterion (LVEF of ≤35% and New York Heart Association class II or III), and LGE scar analyzed by humans or the machine-learning algorithm as predictors of MACE. Machine-based dense or total scar conferred incremental value over the guideline criterion for the association with MACE (AUC: 0.68 vs 0.63, P = .02 and AUC: 0.67 vs 0.63, P = .01, respectively). Modeling with competing risks yielded for dense and total scar (AUC: 0.67 vs 0.61, P = .01 and AUC: 0.66 vs 0.61, P = .005, respectively). Conclusion In this analysis of the multicenter CarDiac MagnEtic Resonance for Primary Prevention Implantable CardioVerter DebrillAtor ThErapy (DERIVATE) registry, fully automatic machine learning-based late gadolinium enhancement analysis reliably quantifies myocardial scar mass and improves the current prediction model that uses guideline-based risk criteria for implantable cardioverter defibrillator implantation. ClinicalTrials.gov registration no.: NCT03352648 Published under a CC BY 4.0 license. Supplemental material is available for this article.


Asunto(s)
Cicatriz , Medios de Contraste , Masculino , Humanos , Anciano , Volumen Sistólico , Estudios Retrospectivos , Imagen por Resonancia Cinemagnética/métodos , Gadolinio , Función Ventricular Izquierda , Imagen por Resonancia Magnética/métodos , Sistema de Registros , Inteligencia Artificial , Valor Predictivo de las Pruebas
5.
Rev Med Suisse ; 17(723): 172-180, 2021 Jan 27.
Artículo en Francés | MEDLINE | ID: mdl-33507655

RESUMEN

In 2020, new guidelines have been published by the European Society of Cardiology including those on non-ST-segment elevation acute coronary syndromes, atrial fibrillation and adult congenital heart disease. Regarding interventional cardiology, POPular TAVI opens the possibility of anti-platelet monotherapy after transcutaneous aortic valve replacement. EMPEROR-Reduced confirms the importance of SGLT2 inhibitors in the treatment of heart failure with reduced ejection fraction. Within the field of imaging, stress MRI has now become the first-line technique for the screening of coronary artery disease, demonstrating an excellent cost-benefit ratio. Finally, renin-angiotensin-aldosterone inhibitors do not appear to increase the risk of an infection by COVID-19.


L'année 2020 a été marquée par la publication de nouvelles guidelines de la Société européenne de cardiologie dont le syndrome coronarien aigu sans élévation du segment ST, la fibrillation auriculaire et les cardiopathies congénitales à l'âge adulte. En interventionnel, POPular TAVI permet d'envisager la monothérapie antithrombotique après remplacement de la valve aortique par voie transcutanée. EMPEROR-Reduced confirme l'importance des inhibiteurs du cotransporteur sodium-glucose de type 2 dans le traitement de l'insuffisance cardiaque à fraction d'éjection réduite. En imagerie, l'IRM de stress s'impose comme examen de choix pour le dépistage de la maladie coronarienne avec un rapport coût-bénéfice favorable. Enfin, les inhibiteurs du système rénine-angiotensine-aldostérone ne semblent pas augmenter le risque d'une infection au Covid-19.


Asunto(s)
COVID-19 , Cardiología , Cardiopatías Congénitas , Humanos , SARS-CoV-2
6.
Case Rep Dermatol Med ; 2013: 894927, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23991340

RESUMEN

Cutaneous mucormycosis is a rare manifestation of an aggressive fungal infection. Early diagnosis and treatment are vitally important in improving outcome. We report an unusual case presenting with progressive necrotizing fasciitis due to mucormycosis following trauma and dressing by man-made herbal agents.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA