Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 46(4): 273-278, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36751953

RESUMEN

BACKGROUND: The subcutaneous implantable-defibrillator (S-ICD) is a relatively new alternative to the transvenous ICD system to minimize intravascular lead-related complications. This paper presents outcome of SICD implantation in patients enrolled in Iran S-ICD registry. METHODS: Between October 2015 and June 2022, this prospective multicenter national registry included 223 patients with a standard indication for an ICD, who neither required bradycardia pacing nor needed cardiac resynchronization to evaluate the early post-implant complications and long-term follow-up results of the S-ICD system. RESULTS: The mean age of the patients was 45 ± 17 years. The majority (79.4%) were male. Ischemic cardiomyopathy (39.5%) was the most common underlying disorder among patients selected for S-ICD implant. Most study patients (68.6%) had ICD for primary prevention of sudden cardiac death. Seven patients (3.1%) were found to have suboptimal lead positions. Six patients (2.7%) developed a pocket hematoma; all were managed medically. During a mean follow-up of 2 years, the appropriate therapy was recorded in 13% of the patients and inappropriate ICD intervention mainly due to supraventricular tachycardia in 8.9%. Pocket infection was observed in four patients (1.8%) and five patients (2.2%) died mainly due to heart failure. CONCLUSION: S-ICDs were effective at detecting and treating both induced and spontaneous ventricular arrhythmias. Major clinical complications were rare.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Irán , Resultado del Tratamiento , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Sistema de Registros
2.
Korean Circ J ; 46(4): 580-3, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27482270

RESUMEN

Left atrial intramural hematoma is a very rare complication of radiofrequency ablation procedures. A patient with tachyarrhythmia underwent radiofrequency catheter ablation. Echocardiography performed the following morning showed a large mass in the left atrium, suggestive of intramural hematoma formation. The patient was in a stable condition; therefore, it was decided that follow-up should be conservative and her anticoagulation therapy was continued. The size of the hematoma decreased significantly over the following 50 days. This case highlights a rare complication of a complex catheter ablation procedure in the left atrium that was managed via a noninvasive approach, with which all interventionists should be familiar.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...