Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Vasc Surg ; 77(2): 366-373, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36181994

RESUMEN

OBJECTIVE: Endovascular treatment of complex aortic pathology has been associated with increases in procedural-related metrics, including the operative time and radiation exposure. Three-dimensional fusion imaging technology has decreased the radiation dose and iodinated contrast use during endovascular aneurysm repair. The aim of the present study was to report our institutional experience with the use of a cloud-based fusion imaging platform during fenestrated endovascular aneurysm repair (FEVAR). METHODS: A retrospective review of a prospectively maintained aortic database was performed to identify all patients who had undergone FEVAR with commercially available devices (Zenith Fenestrated; Cook Medical Inc, Bloomington, IN) between 2013 and 2020 and all endovascular aneurysm repairs performed using Cydar EV Intelligent Maps (Cydar Medical, Cambridge, UK). The Cydar EV cohort was reviewed further to select all FEVARs performed with overlay map guidance. The patient demographic, clinical, and procedure metrics were analyzed, with a comparative analysis of FEVAR performed without and with the Cydar EV imaging platform. Patients were excluded from comparative analysis if the data were incomplete in the dataset or they had a documented history of prior open or endovascular abdominal aortic aneurysm repair. RESULTS: During the 7-year study period, 191 FEVARs had been performed. The Cydar EV imaging platform was implemented in 2018 and used in 124 complex endovascular aneurysm repairs, including 69 consecutive FEVARs. A complete dataset was available for 137 FEVARs. With exclusion to select for de novo FEVAR, a comparative analysis was performed of 53 FEVAR without and 63 with Cydar EV imaging guidance. The cohorts were similar in patient demographics, medical comorbidities, and aortic aneurysm characteristics. No significant difference was noted between the two groups for major adverse postoperative events, length of stay, or length of intensive care unit stay. The use of Cydar EV resulted in nonsignificant decreases in the mean fluoroscopy time (69.3 ± 28 minutes vs 66.2 ± 33 minutes; P = .598) and operative time (204.4 ± 64 minutes vs 186 ± 105 minutes; P = .278). A statistically significant decrease was found in the iodinated contrast volume (105 ± 44 mL vs 83 ± 32 mL; P = .005), patient radiation exposure using the dose area product (1,049,841 mGy/cm2 vs 630,990 mGy/cm2; P < .001) and cumulative air kerma levels (4518 mGy vs 3084 mGy; P = .02) for patients undergoing FEVAR with Cydar EV guidance. CONCLUSIONS: At our aortic center, we have observed a trend toward shorter operative times and significant reductions in both iodinated contrast use and radiation exposure during FEVAR using the Cydar EV intelligent maps. Intelligent map guidance improved the efficiency of complex endovascular aneurysm repair, providing a safer intervention for both patient and practitioner.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/etiología , Nube Computacional , Factores de Riesgo , Resultado del Tratamiento , Medios de Contraste , Estudios Retrospectivos , Diseño de Prótesis
2.
Ann Vasc Surg ; 46: 142-146, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28887248

RESUMEN

BACKGROUND: In January 2015, we created a multidisciplinary Aortic Center with the collaboration of Vascular Surgery, Cardiac Surgery, Interventional Radiology, Anesthesia and Hospital Administration. We report the initial success of creating a Comprehensive Aortic Center. METHODS: All aortic procedures performed from January 1, 2015 until December 31, 2016 were entered into a prospectively collected database and compared with available data for 2014. Primary outcomes included the number of all aortic related procedures, transfer acceptance rate, transfer time, and proportion of elective/emergent referrals. RESULTS: The Aortic Center included 5 vascular surgeons, 2 cardiac surgeons, and 2 interventional radiologists. Workflow processes were implemented to streamline patient transfers as well as physician and operating room notification. Total aortic volume increased significantly from 162 to 261 patients. This reflected an overall 59% (P = 0.0167) increase in all aorta-related procedures. We had a 65% overall increase in transfer requests with 156% increase in acceptance of referrals and 136% drop in transfer denials (P < 0.0001). Emergent abdominal aortic cases accounted for 17% (n = 45) of our total aortic volume in 2015. The average transfer time from request to arrival decreased from 515 to 352 min, although this change was not statistically significant. We did see a significant increase in the use of air-transfers for aortic patients (P = 0.0041). Factorial analysis showed that time for transfer was affected only by air-transfer use, regardless of the year the patient was transferred. Transfer volume and volume of aortic related procedures remained stable in 2016. CONCLUSIONS: Designation as a comprehensive Aortic Center with implementation of strategic workflow systems and a culture of "no refusal of transfers" resulted in a significant increase in aortic volume for both emergent and elective aortic cases. Case volumes increased for all specialties involved in the center. Improvements in transfer center and emergency medical services communication demonstrated a trend toward more efficient transfer times. These increases and improvements were sustainable for 2 years after this designation.


Asunto(s)
Aorta/cirugía , Enfermedades de la Aorta/cirugía , Procedimientos Quirúrgicos Cardíacos , Servicios Centralizados de Hospital/organización & administración , Prestación Integrada de Atención de Salud/organización & administración , Radiólogos/organización & administración , Radiología Intervencionista/organización & administración , Cirujanos/organización & administración , Centros Traumatológicos/organización & administración , Procedimientos Quirúrgicos Vasculares/organización & administración , Procedimientos Quirúrgicos Cardíacos/clasificación , Servicio de Cardiología en Hospital/organización & administración , Servicios Centralizados de Hospital/clasificación , Conducta Cooperativa , Bases de Datos Factuales , Prestación Integrada de Atención de Salud/clasificación , Procedimientos Quirúrgicos Electivos , Urgencias Médicas , Florida , Humanos , Comunicación Interdisciplinaria , Grupo de Atención al Paciente/clasificación , Grupo de Atención al Paciente/organización & administración , Transferencia de Pacientes/organización & administración , Evaluación de Programas y Proyectos de Salud , Radiólogos/clasificación , Servicio de Radiología en Hospital/organización & administración , Radiología Intervencionista/clasificación , Derivación y Consulta/organización & administración , Estudios Retrospectivos , Cirujanos/clasificación , Terminología como Asunto , Factores de Tiempo , Tiempo de Tratamiento/organización & administración , Centros Traumatológicos/clasificación , Procedimientos Quirúrgicos Vasculares/clasificación , Flujo de Trabajo , Carga de Trabajo
3.
Vasc Endovascular Surg ; 51(8): 555-561, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28914176

RESUMEN

INTRODUCTION: The natural history and potential morbidity of gutter endoleaks are unclear. We present our experience with intraoperative gutter endoleaks and strategies to determine which of these require intervention. METHODS: This is a retrospective review of all patients treated with parallel stent grafts from January 2010 to September 2015. We reviewed all operative records and intraoperative angiograms as well as all postoperative imaging and secondary interventions. All gutter leaks were classified as low-flow/nonsac-enhancing gutter endoleaks or high-flow/sac-enhancing gutter endoleaks. Adjunctive interventions to manage the gutter leaks were noted, as were all subsequent interventions for gutter leak and endoleak management. RESULTS: Seventy-eight patients had 144 parallel stents placed over a 5-year period with an average of 1.8 stents per patient. Twenty-eight patients (36%) had gutter endoleaks diagnosed intraoperatively. Seventeen patients had adjunctive procedures to reduce gutter leaks prior to leaving the operating room (OR). Patients selected for treatment had gutters filling early during completion angiography and/or contrast enhancement of the aneurysm sac. Twenty-two patients (28%) left the OR with low-flow/delayed/nonsac-enhancing gutter endoleaks. At 30 days, a total of 6 persistent gutter endoleaks were diagnosed on computed tomographic angiography. This gives a 73% rate of resolution for low-flow/nonaneurysm sac-enhancing endoleaks. There were 2 de novo endoleaks not detected at the index procedure diagnosed at 6-month follow-up. Of the 8 total postoperative endoleaks, 5 required additional intervention with a 100% success rate. Multivariate analysis revealed that the only significant predictor of having a postoperative endoleak is leaving the OR with an endoleak. CONCLUSIONS: Intraoperative treatment of gutter endoleaks has an acceptable rate of resolution. It does have a high rate of converting high-flow endoleaks to low-flow endoleaks. Low-flow/nonsac-enhancing gutter endoleaks have a high rate of spontaneous resolution. Intraoperative gutter endoleaks are not predictive of future aneurysm sac growth.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Angiografía por Tomografía Computarizada , Endofuga/diagnóstico por imagen , Endofuga/terapia , Procedimientos Endovasculares/instrumentación , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Análisis Multivariante , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA