Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Blood ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38669631

RESUMEN

HLA-mismatched transplants with either in vitro depletion of CD3+TCRαß/CD19 (TCRαß) cells or in vivo T-cell depletion using post-transplant cyclophosphamide (PTCY) have been increasingly used for patients with inborn errors of immunity (IEI). We performed a retrospective multicenter study via the EBMT registry on 306 children with IEI undergoing first transplant between 2010-2019 from an HLA-mismatched donor using TCRαß (n=167) or PTCY (n=139). Median age at HSCT was 1.2 years (range, 0.03-19.6 years). The 3-year overall survival (OS) was 78% (95% confidence interval (CI), 71-84%) after TCRαß and 66% (57-74%) after PTCY (p=0.013). Pre-HSCT morbidity score (hazard ratio (HR) 2.27, 1.07-4.80, p=0.032) and non-Busulfan/Treosulfan conditioning (HR 3.12, 1.98-4.92, p<0.001) were the only independent predictors of unfavorable OS. The 3-year event-free survival (EFS) was 58% (50-66%) after TCRαß and 57% (48-66%) after PTCY (p=0.804). Cumulative incidence of severe acute GvHD was higher after PTCY (15%, 9-21%) than TCRαß (6%, 2-9%, p=0.007), with no difference in chronic GvHD (PTCY, 11%, 6-17%; TCRαß, 7%, 3-11%, p=0.173). The 3-year GvHD-free EFS was 53% (44-61%) after TCRαß and 41% (32-50%) after PTCY (p=0.080). PTCY had significantly higher rates of veno-occlusive disease (14.4% versus TCRαß 4.9%, p=0.009), acute kidney injury (12.7% versus 4.6%, p=0.032) and pulmonary complications (38.2% versus 24.1%, p=0.017). Adenoviraemia (18.3% versus PTCY 8.0%, p=0.015), primary graft failure (10%, versus 5%, p=0.048), and second HSCT (17.4% versus 7.9%, p=0.023) were significantly higher in TCRαß. In conclusion, this study demonstrates that both approaches are suitable options in IEI patients, although characterized by different advantages and outcomes.

2.
CVIR Endovasc ; 5(1): 2, 2022 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-34978632

RESUMEN

PURPOSE: To describe the interventional management and clinical outcome of pancreatico-duodenal arterio-venous malformations (PDAVMs). MATERIAL AND METHODS: Seven patients presenting a PDAVM (6 women, 1 male; mean age: 61) were retrospectively reviewed. Technical, clinical success and complications of embolization and surgical management of symptomatic PDAVMs were assessed. Technical success was defined as a complete occlusion of the PDAVM and clinical success as no clinical symptom or recurrence during follow-up. Patients with asymptomatic PDAVMs were followed clinically, by Doppler ultrasound and CT-angiography. RESULTS: Mean follow-up time was 69 months (15-180). Five symptomatic patients presented with upper gastrointestinal bleeding (n=3), ascites (n=1), and abdominal pain (n=1). Two patients were asymptomatic. The PDAVMs were classified as follow: Yakes I (1), IIIa (2), IIIb (3) and IV (1). Five symptomatic patients were treated with 9 embolization sessions with arterial approach (onyx®, glue, coils) in 7 and venous approach in 2 (plugs, coils, covered stents, STS foam and onyx®). Technical success of embolization was 60% (3/5). Devascularization was incomplete for 2 Yakes IIIB patients. Clinical success of embolization was estimated at 80% (4/5) as one patient required additional surgery (Whipple) because of persistent bleeding. One splenic vein thrombosis was treated successfully by mechanical thrombectomy and heparin. No recurrence occurred during follow-up. No progression was documented in asymptomatic patients. CONCLUSION: Embolization of symptomatic PDAVMs is effective and surgery should be performed in second intention. Complete devascularization is more difficult to obtain in Yakes III PDAVM.

3.
J Vasc Interv Radiol ; 32(3): 350-359.e2, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33483226

RESUMEN

PURPOSE: To assess whether angioplasty of hemodialysis access (HA) stenosis with a drug-coated balloon (DCB) would prevent restenosis in comparison with plain-balloon percutaneous transluminal angioplasty (PTA). MATERIALS AND METHODS: This prospective randomized clinical trial enrolled 120 patients with dysfunctional arteriovenous fistulae (n = 109) and grafts (n = 11), due to a ≥50% stenosis between March 2014 and April 2018. All patients underwent high-pressure balloon angioplasty and were then randomized to either DCB (n = 60) or PTA (n = 60). Patients were followed-up for 1 year, and angiography was performed 6 months after angioplasty. The primary endpoint was the late lumen loss (LLL) at 6 months. Secondary endpoints included other angiographic parameters at 6 months and HA failures, adverse event, and mortality at 12 months. Continuous variables were compared with a Student t-test, and Kaplan-Meier curves were used for freedom from HA failure and for mortality. RESULTS: LLL in the DCB and in the PTA group were 0.64 mm ± 1.20 and 1.13 mm ± 1.51, respectively (P = .082, adjusted P = .0498). DCB was associated with lower percentage stenosis (54.2% ± 19.3 vs 61.7% ± 18.2; P = .047) and binary restenosis ≥50% (56.5% vs 81.1%; P = .009) than PTA. The number of HA failures after 12 months was lower for DCB than for PTA (45% vs 66.7%; P = .017). Mortality at 12 months was 10% and 8.3% in the DCB and PTA groups, respectively (P = .75). CONCLUSIONS: Despite LLL improvement that failed to reach statistical significance, this study demonstrated decreased incidence and severity of restenosis with DCB compared with PTA to treat dysfunctional HA.


Asunto(s)
Angioplastia de Balón/instrumentación , Derivación Arteriovenosa Quirúrgica/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Oclusión de Injerto Vascular/terapia , Paclitaxel/administración & dosificación , Diálisis Renal , Dispositivos de Acceso Vascular , Anciano , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/mortalidad , Derivación Arteriovenosa Quirúrgica/mortalidad , Implantación de Prótesis Vascular/mortalidad , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/mortalidad , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Quebec , Recurrencia , Factores de Riesgo , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
4.
Can Assoc Radiol J ; 72(2): 317-323, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32216558

RESUMEN

PURPOSE: To quantify eye lens dose in interventional radiology and assess whether neck dosimeter is a good surrogate to evaluate eye lens dosimetry. METHODS: Radiation exposure was prospectively measured in 9 interventional radiologists between May and October 2017. Standard Hp(0,07) thermoluminescent dosimeters (TLDs) were worn at the neck outside the lead apron, and 2 dedicated eye lens Hp(3) TLDs were placed just above the eyes, one midline and another at the outer edge of the left eye. Correlations between eye lens and neck TLD doses were assessed with Pearson coefficient, and linear regression was used to predict eye lens dose from neck TLD values. RESULTS: Eye lens dose without eye protection was 0.18 ± 0.11 (mean ± standard deviation; 0.08-0.41) mSv per workday and 35.3 ± 6.6 mSv (16.3-82.9) annually (200 workdays/year). Five (56%) radiologists exceeded the 20 mSv annual eye lens dose limit. Eye lens doses from left and central TLDs were 12.46 ± 3.02 and 9.29 ± 3.38 mSv, respectively (P = .027). Mean eye lens (left and central) and neck TLD doses were 10.87 ± 2.67 and 16.56 ± 5.67 mSv, respectively (P = .008). Pearson correlation coefficient between both eye lens TLD and between mean eye lens TLD and neck TLD doses were 0.91 and 0.92, respectively. Average of eye lens dose was 0.0179 + (0.5971 × neck dose). CONCLUSION: Full-time interventional radiologists are likely to suffer from deterministic radiation effects to the eye lens, especially on the left side. Neck TLD significantly overestimates eye lens dose. However, eye lens doses are highly correlated with neck doses and may be predicted from the neck TLD values.


Asunto(s)
Cristalino , Exposición Profesional/estadística & datos numéricos , Dosis de Radiación , Dosímetros de Radiación/estadística & datos numéricos , Exposición a la Radiación/estadística & datos numéricos , Radiología Intervencionista/estadística & datos numéricos , Humanos , Estudios Prospectivos , Protección Radiológica , Reproducibilidad de los Resultados
5.
J Vasc Interv Radiol ; 31(3): 444-453.e2, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31982312

RESUMEN

PURPOSE: This study evaluated the safety and efficacy of the JETi8 peripheral thrombectomy system in treating acute deep vein thrombosis (DVT). MATERIALS AND METHODS: A retrospective study was conducted in 18 consecutive patients (mean age, 41 years old [range, 15-74 years old]; 5 men and 13 women). There were 21 instances of DVTs (9 iliofemoral, 10 axillosubclavian, and 2 portal), which were treated using the JETi8 thrombectomy device between November 2016 and July 2018. Thrombus was laced with recombinant tissue plasminogen activator (r-TPA) (9.3 mg, on average; range, 2-12 mg) in 17 procedures (81%) prior to thrombectomy. Technical success was defined as restoration of antegrade flow using the JETi8 with or without additional treatment of an underlying obstructive lesion. Procedural success was defined as technical success with or without the addition of overnight catheter-directed thrombolysis (CDT) RESULTS: Mean procedure time was 83 minutes (range, 30-160 minutes), and mean thrombus reduction with the JETi8 alone was 92% (range, 60%-100%). Stent placement was required in 6 procedures (29%). Technical success using the JETi8 system alone was 76% (16 of 21 procedures), whereas 5 procedures (24%) required subsequent overnight CDT in the intensive care unit. Procedural success rate was 100% (20 of 20 procedures). Mean aspirated volume was 531 mL (range, 250-1,230 mL). The only adverse event was a subsegmental pulmonary embolism. Seven patients (33%) were discharged the same day. Recurrent thrombosis was observed in 5 patients (24%), of whom 3 were successfully treated with the JETi8 system. CONCLUSIONS: The JETi8 system may be a safe and effective option for thrombectomy of acute DVT.


Asunto(s)
Trombectomía/instrumentación , Trombosis de la Vena/terapia , Adolescente , Adulto , Anciano , Angioplastia de Balón/instrumentación , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Quebec , Proteínas Recombinantes/administración & dosificación , Recurrencia , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Stents , Trombectomía/efectos adversos , Terapia Trombolítica , Factores de Tiempo , Activador de Tejido Plasminógeno/administración & dosificación , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Trombosis de la Vena/fisiopatología , Adulto Joven
6.
7.
J Vasc Interv Radiol ; 30(4): 523-530, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30910174

RESUMEN

PURPOSE: To compare automated measurements of maximal diameter (Dmax) of abdominal aortic aneurysm (AAA) orthogonal to luminal or outer wall envelope centerline for endovascular repair (EVAR) follow-up. MATERIAL AND METHODS: Eighty-three consecutive patients with AAA treated by EVAR who had at least 1 computed tomography (CT) scan before and 2 CT scans after EVAR with at least 5 months' interval were included. Three-dimensional reconstruction of the AAA was achieved with dedicated segmentation software. Performances of automated calculation algorithms of Dmax perpendicular to lumen or outer wall envelope centerlines were then compared to manual measurement of Dmax on double-oblique multiplanar reconstruction (gold standard). Accuracy of automated Dmax measurements at baseline, follow-up, and progression over time was evaluated by calculation of mean error, Bland-Altman plot, and regression models. RESULTS: Disagreement in Dmax measurements between outer wall envelope algorithm and manual method was insignificant (mean error: baseline, -0.07 ± 1.66 mm, P = .7; first follow-up, 0.24 ± 1.69 mm, P = .2; last follow-up, -0.41 ± 2.74 mm, P = .17); whereas significant discrepancies were found between the luminal algorithm and the manual method (mean error: baseline, -1.24 ± 2.01 mm, P < .01; first follow-up, -1.49 ± 3.30 mm, P < .01; last follow-up, -1.78 ± 3.60 mm, P < .01). Dmax progression results were more accurate with AAA outer wall envelope algorithm compared to luminal method (P = .2). CONCLUSIONS: AAA outer wall envelope segmentation is recommended to enable automated calculation of Dmax perpendicular to its centerline during EVAR follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Angiografía por Tomografía Computarizada/métodos , Procedimientos Endovasculares , Tomografía Computarizada Multidetector/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Validación de Programas de Computación , Anciano , Anciano de 80 o más Años , Automatización , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
8.
J Vasc Interv Radiol ; 29(6): 809-815, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29628299

RESUMEN

PURPOSE: To evaluate the efficacy and safety of sclerotherapy with sodium tetradecyl sulfate (STS) and bleomycin for treatment of venous malformations (VMs) of the oropharyngeal region. MATERIALS AND METHODS: A retrospective study of 33 patients with 46 VMs of the buccal and pharyngolaryngeal cavity associated with impairment of eating, respiration, or elocution was performed. Individual lesions were divided based on their anterior or posterior location, using the base of the tongue as an anatomic landmark. Lesion size was estimated with the use of orthogonal measurements on magnetic resonance or ultrasound images before and after treatment to assess radiologic response. Sclerotherapy sessions were performed under ultrasound, fluoroscopic, and, if needed, endoscopic guidance. Clinical response was assessed with the use of the Manchester Orofacial Pain Disability Scale. Methods for airway management were also compiled. RESULTS: Following sclerotherapy, average VM diameter was reduced by 31.4% (P < .0001) on a per-patient basis and by 30.8% (P < .0001) on a per-lesion basis. The Manchester score improved by an average of 37.0% (P = .013). Four patients reported a worsening of symptoms, and 11 patients experienced symptomatic recurrence. Complications include pneumonia (5 patients) and urgent placement of a post-procedure tracheostomy (4 patients). Patients with posterior malformations experienced more complications (emergency tracheostomies in 4 and pneumonias in 4). CONCLUSIONS: Sclerotherapy using STS is an efficient treatment for venous malformations of the buccal and pharyngolaryngeal cavity but can lead to significant complication for posterior lesions. Careful assessment of the airway is needed before treatment, and prophylactic tracheotomy should be considered in patients with posterior lesions.


Asunto(s)
Orofaringe/anomalías , Orofaringe/irrigación sanguínea , Escleroterapia/métodos , Malformaciones Vasculares/terapia , Adolescente , Adulto , Anciano , Bleomicina/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Soluciones Esclerosantes/administración & dosificación , Tetradecil Sulfato de Sodio/administración & dosificación , Resultado del Tratamiento
9.
J Dent Child (Chic) ; 85(3): 120-124, 2018 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-30869588

RESUMEN

Purpose: The purpose of this study was to investigate the inhibitory in vitro effects of silver diamine fluoride (SDF) with and without a saturated solution of potassium iodide (SSKI) on established Streptococcus mutans biofilm.Methods: Fifty µl of an overnight S. mutans culture (106 CFU per mL) in Tryptic Soy Broth (TSB) and three ml of fresh TSB supplemented with one percent sucrose (TSBS) were incubated for 24 hours to establish an S. mutans biofilm in six-well tissue culture plates. Four treatments (SDF, SSKI, SDF plus SSKI, and untreated control) were used to disrupt the biofilm. The biofilm groups were each treated with reagent and washed; the biofilm was collected, diluted, and spiral-plated onto blood agar plates; and an automated counting machine was used to determine the bacterial colony forming units (CFU).Results: The control had significantly more CFU than the SSKI, SDF, and SDF plus SSKI groups (P<.0001). The SSKI group had significantly more CFU than the SDF and SDF plus SSKI groups (P<.0001). The SDF group had significantly fewer CFU than the SDF plus SSKI group (P=.02). The reduction from the control was more than seven-fold for SDF, four-fold for SDF plus SSKI, and two-fold for SSKI.Conclusions: SDF alone, SDF plus SSKI, and SSKI disrupted an established S. mutans biofilm. SDF alone had the greatest overall disruption.


Asunto(s)
Biopelículas/efectos de los fármacos , Yoduro de Potasio/antagonistas & inhibidores , Compuestos de Amonio Cuaternario/antagonistas & inhibidores , Compuestos de Plata/antagonistas & inhibidores , Streptococcus mutans/efectos de los fármacos , Caries Dental/microbiología , Caries Dental/prevención & control , Combinación de Medicamentos , Fluoruros Tópicos , Viabilidad Microbiana/efectos de los fármacos
10.
Radiology ; 286(3): 1072-1083, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29206595

RESUMEN

Purpose To assess response to transcatheter arterial chemoembolization (TACE) based on immune markers and tumor biology in patients with hepatocellular carcinoma (HCC) who were bridged to liver transplantation, and to produce an optimized pretransplantation model for posttransplantation recurrence risk. Materials and Methods In this institutional review board-approved HIPAA-compliant retrospective analysis, 93 consecutive patients (73 male, 20 female; mean age, 59.6 years; age range, 23-72 years) underwent TACE with doxorubicin-eluting microspheres (DEB) (hereafter, DEB-TACE) and subsequently underwent transplantation over a 5-year period from July 7, 2011, to May 16, 2016. DEB-TACE response was based on modified Response Evaluation Criteria in Solid Tumors. Imaging responses and posttransplantation recurrence were compared with demographics, liver function, basic immune markers, treatment dose, and tumor morphology. Treatment response and recurrence were analyzed with uni- and multivariate statistics, as well as internal validation and propensity score matching of factors known to affect recurrence to assess independent effects of DEB-TACE response on recurrence. Results Low-grade tumors (grade 0, 1, or 2) demonstrated a favorable long-term treatment response in 87% of patients (complete response, 49%; partial response, 38%; stable disease [SD] or local disease progression [DP], 13%) versus 33% of high-grade tumors (grade 3 or 4) (complete response, 0%; partial response, 33%; SD or DP, 67%) (P < .001). Of the 93 patients who underwent treatment, 82 were followed-up after transplantation (mean duration, 757 days). Recurrence occurred in seven (9%) patients (mean time after transplantation, 635 days). Poor response to DEB-TACE (SD or DP) was present in 86% of cases and accounted for 35% of all patients with SD or DP (P < .001). By using only variables routinely available prior to liver transplantation, a validated model of posttransplantation recurrence risk was produced with a concordance statistic of 0.83. The validated model shows sensitivity of 83.6%, specificity of 82.6%, and negative predictive value of 98.4%, which are pessimistic estimates. Conclusion Response to DEB-TACE is correlated with tumor biology and patients at risk for posttransplantation recurrence, and it may be associated with HCC recurrence after liver transplantation. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Antineoplásicos/uso terapéutico , Carcinoma Hepatocelular , Quimioembolización Terapéutica , Doxorrubicina/uso terapéutico , Neoplasias Hepáticas , Trasplante de Hígado/estadística & datos numéricos , Adulto , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/epidemiología , Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Quimioembolización Terapéutica/estadística & datos numéricos , Preparaciones de Acción Retardada , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/epidemiología , Neoplasias Hepáticas/terapia , Masculino , Microesferas , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento , Adulto Joven
11.
Ochsner J ; 17(4): 412-416, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29230127

RESUMEN

BACKGROUND: Since the early 1990s, the minimally invasive image-guided therapies used in interventional oncology to treat hepatocellular carcinoma have continued to evolve. Additionally, the range of applications has been expanded to the treatment of hepatic metastases from colorectal cancer, neuroendocrine tumors, cholangiocarcinoma, breast cancer, melanoma, and sarcoma. METHODS: We searched the literature to identify publications from 1990 to the present on various image-guided intraarterial therapies and their efficacy, as well as their role in the management of primary and secondary liver malignancies. RESULTS: Chemoembolization and radioembolization are considered a standard of care in treating, delaying progression of disease, and downstaging to bridge to liver transplantation. Progression-free survival and overall survival outcomes are promising in patients with colorectal cancer and neuroendocrine tumors with liver metastases. Applications in the treatment of hepatic metastases from cholangiocarcinoma, breast cancer, melanoma, and sarcoma also show potential. CONCLUSION: Interventional oncology and its image-guided intraarterial therapies continue to gain recognition as treatment options for primary and secondary liver cancers. Growing evidence supports their role as a standard of care alongside medical oncology, surgery, and radiation oncology.

12.
Semin Intervent Radiol ; 34(3): 258-271, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28955115

RESUMEN

Arteriovenous malformations (AVMs) are high-flow vascular anomalies that have demonstrated a very high recurrence rate after endovascular treatment, surgical treatment, or a combination of both. Surgical treatments have shown good response when they are small and well localized but a poor response when diffuse. A better understanding of the nature of the lesion has led to a better response rate and a safer treatment for these patients. This has been accomplished through a detailed understanding of the angioarchitecture of the lesion, enabling a tailored approach in reaching and targeting the nidus of the AVM with different liquid embolic agents, more specifically ethanol. Flow reduction techniques help in exposing the nidus to sclerosant agents. A clinical classification, the Schobinger classification, will help determine the appropriate time to start or to pursue therapy.

13.
Eur J Endocrinol ; 176(2): 159-167, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27836950

RESUMEN

OBJECTIVE: Many investigators believe that basal adrenal venous sampling (AVS) should be done simultaneously, whereas others opt for sequential AVS for simplicity and reduced cost. This study aimed to evaluate the concordance of sequential and simultaneous AVS methods. DESIGN AND METHODS: Between 1989 and 2015, bilateral simultaneous sets of basal AVS were obtained twice within 5 min, in 188 consecutive patients (59 women and 129 men; mean age: 53.4 years). Selectivity was defined by adrenal-to-peripheral cortisol ratio ≥2, and lateralization was defined as an adrenal aldosterone-to-cortisol ratio ≥2, the contralateral side. Sequential AVS was simulated using right sampling at -5 min (t = -5) and left sampling at 0 min (t = 0). RESULTS: There was no significant difference in mean selectivity ratio (P = 0.12 and P = 0.42 for the right and left sides respectively) and in mean lateralization ratio (P = 0.93) between t = -5 and t = 0. Kappa for selectivity between 2 simultaneous AVS was 0.71 (95% CI: 0.60-0.82), whereas it was 0.84 (95% CI: 0.76-0.92) and 0.85 (95% CI: 0.77-0.93) between sequential and simultaneous AVS at respectively -5 min and at 0 min. Kappa for lateralization between 2 simultaneous AVS was 0.84 (95% CI: 0.75-0.93), whereas it was 0.86 (95% CI: 0.78-0.94) and 0.80 (95% CI: 0.71-0.90) between sequential AVS and simultaneous AVS at respectively -5 min at 0 min. CONCLUSIONS: Concordance between simultaneous and sequential AVS was not different than that between 2 repeated simultaneous AVS in the same patient. Therefore, a better diagnostic performance is not a good argument to select the AVS method.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Hiperaldosteronismo/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Aldosterona/metabolismo , Femenino , Humanos , Hidrocortisona/metabolismo , Vena Ilíaca , Masculino , Persona de Mediana Edad , Adulto Joven
14.
J Hypertens ; 35(2): 362-368, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27861246

RESUMEN

OBJECTIVE: Difficulty to recognize or canulate the right adrenal vein is the most frequent cause of adrenal venous sampling (AVS) failure. We aimed to assess multinomial regression modeling (MRM) of peripheral and left adrenal vein samplings to detect lateralization of aldosterone secretion when the right AVS is missing. METHODS: Simultaneous bilateral AVS samplings were performed before (basal) and after intravenous cosyntropin injection in 188 consecutive patients between December 1989 and September 2015. Different reference standards for lateralization of aldosterone secretion were defined for basal and for postcosyntropin AVS and according to lateralization index cutoffs at least 2 and at least 4. MRMs were built to detect lateralization of aldosterone secretion according to these reference standards using only peripheral and left adrenal veins samplings (without the right AVS). Detection accuracy was assessed by the area under the receiver operating characteristic (AUROC) curves and detection sensitivities were reported for specificity at least 95%. RESULTS: For basal AVS with lateralization index at least 2, AUROC were respectively 0.931 [95% confidence interval (CI) 0.894-0.968] and 0.922 (95% CI 0.882-0.962) for right and left lateralization of aldosterone secretion detection and MRM could detect respectively 65.5 and 62.7% of the right and left lateralization of aldosterone secretion. For AVS after cosyntropin with lateralization index at least 4, AUROC were respectively 0.964 (95% CI: 0.940-0.987) and 0.955 (95% CI: 0.927-0.983) for right and left lateralization of aldosterone secretion, and MRM could detect respectively 77.2 and 72.9% of the right and left lateralization of aldosterone secretion. CONCLUSION: MRM can detect lateralization of aldosterone secretion without the right AVS in most patients and could eliminate the need for repeat AVS when right adrenal vein canulation is nonselective or impossible.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Aldosterona/metabolismo , Hiperaldosteronismo/sangre , Adulto , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Cosintropina/farmacología , Femenino , Hormonas/farmacología , Humanos , Hiperaldosteronismo/diagnóstico , Masculino , Persona de Mediana Edad , Curva ROC , Análisis de Regresión , Estudios Retrospectivos , Venas , Adulto Joven
15.
Case Rep Obstet Gynecol ; 2016: 6353471, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27403360

RESUMEN

This is a case of choriocarcinoma that did not regress after chemotherapy treatment. A 30-year-old female patient (gravida 2, para 2), presented to our ER with stroke and persistent mild pelvic pain 2 months after a Caesarean section. Computed tomography (CT) revealed an ischemic left hemicerebellar region and a hypervascular mass in the pelvic region. This mass was not present on routine fetal ultrasound during pregnancy. The lesion was treated by chemotherapy after closure of a foramen ovale and insertion of an inferior vena cava (IVC) filter. After that, 2 courses of EMACO (Etoposide, Methotrexate, Actinomycin D, Cyclophosphamide, and Vincristine) chemotherapy regimen were given. Posttreatment CT showed the hypervascular mass without any changes. Arteriography showed the arteriovenous fistulae that were embolized successfully with plugs, coils, and glue. Embolization was considered due to the risk of acute hemorrhagic life-threatening complications. Eight chemotherapy courses were added after embolization. Treatment by endovascular approach and reduction of the hypervascular mass can be a valuable adjunct to chemotherapy treatment of choriocarcinoma.

16.
J Vasc Interv Radiol ; 27(8): 1168-9, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27449977
17.
J Vasc Surg ; 63(6): 1531-40, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27021377

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the safety and efficacy of external beam radiation (EBR) in preventing restenosis after superficial femoral artery (SFA) stenting in comparison with a control group treated with SFA stenting only. METHODS: In this Institutional Review Board-approved study, patients who provided written informed consent were randomly assigned to 0 Gy or 14 Gy of EBR to the stent site 24 hours after SFA stenting. The primary end point was the angiographic binary restenosis rate 2 years after stenting. Categorical and continuous end points were respectively analyzed using logistic regression models and Wilcoxon tests. End points expressed as time to event were analyzed using a log-rank test. RESULTS: The study included 155 patients, 46 women and 109 men (mean age, 66 years; range, 45-85 years). In the 0 and 14 Gy groups, binary restenosis was present, respectively, in 44% (34/77) and 68% (52/76; P = .003) 2 years after stenting. Stent thrombosis occurred in 13% (10/78) of the 0 Gy group and in 33% (25/77) of the 14 Gy group (P = .003). Target lesion revascularization at 2 years was 26% (25/78) in the 0 Gy group and 30% (23/77) in the 14 Gy group (P = .56). There were no significant differences in total walking distances change from baseline to 2 years (46 ± 100 and 26 ± 79 m, respectively, in the 0 Gy and 14 Gy group; P = .25). There were no procedure-related deaths and no major amputations. CONCLUSIONS: A single 14 Gy dose of EBR to the SFA stenting site did not prevent in-stent restenosis.


Asunto(s)
Angioplastia de Balón/instrumentación , Braquiterapia/métodos , Arteria Femoral/efectos de la radiación , Enfermedad Arterial Periférica/terapia , Stents , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Angioplastia de Balón/efectos adversos , Braquiterapia/efectos adversos , Constricción Patológica , Supervivencia sin Enfermedad , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Quebec , Dosificación Radioterapéutica , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
Eur J Radiol ; 85(1): 150-157, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26724660

RESUMEN

PURPOSE: To evaluate the sensitivity and specificity of non-enhanced chest CT to detect reperfusion after pulmonary arteriovenous malformation (PAVM) embolization. MATERIALS AND METHODS: The Institutional Review Board approved this retrospective HIPAA-compliant study and waived the need for patient consent. All consecutive patients who underwent PAVM embolization between January 2000 and April 2011 were included. Complex PAVMs and patients without available pre- and/or post-embolization CT were excluded. PAVM artery, aneurysm and vein diameters were measured on non-enhanced chest CT before and after PAVM embolization. Pulmonary angiography (PA) was the reference standard to assess PAVM reperfusion. Reperfusion detection was analyzed with receiver operating characteristic (ROC) curves according to percentage of diameter reduction cut-off. Inter-observer concordance was ascertained with intra-class correlation coefficients (ICCs). RESULTS: Out of 68 patients with PAVM embolizations, 42 (62%) had 108 PAVMs that met inclusion/exclusion criteria. Areas under the ROC curves for PAVM reperfusion detection were 0.84, 0.87, and 0.78, respectively, for PAVM artery, aneurysm and vein (p>0.05). Sensitivity varied between 51% and 56%, and specificity between 86% and 98% for the <30% diameter reduction cut-off. Sensitivity was between 98% and 100%, and specificity, between 20% and 47% for the <70% diameter reduction cut-off. ICCs for inter-observer concordance were 0.58, 0.88 and 0.68 for percentage reduction of PAVM artery, aneurysm and vein, respectively. CONCLUSION: PAVM diameter reduction cut-offs of <30% and <70%, to detect PAVM reperfusion on non-enhanced CT reported in the literature, would respectively result in low sensitivity and specificity.


Asunto(s)
Fístula Arteriovenosa/fisiopatología , Fístula Arteriovenosa/terapia , Malformaciones Arteriovenosas/fisiopatología , Malformaciones Arteriovenosas/terapia , Embolización Terapéutica , Arteria Pulmonar/anomalías , Arteria Pulmonar/fisiopatología , Venas Pulmonares/anomalías , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Angiografía , Fístula Arteriovenosa/diagnóstico , Malformaciones Arteriovenosas/diagnóstico , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Arteria Pulmonar/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
19.
Cardiovasc Intervent Radiol ; 38(6): 1458-67, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25962988

RESUMEN

PURPOSE: To compare the accuracy of C-arm computed tomography (CT) and digital subtraction angiography (DSA) in detecting incomplete stent expansion (ISE) after superficial femoral artery (SFA) stenting using intravascular ultrasound (IVUS) as a gold standard. MATERIALS: Fifty patients with symptomatic SFA occlusive disease requiring angioplasty were prospectively included. Once technical success (<30 % residual stenosis) was obtained on post-procedural DSA, C-arm CT and IVUS were acquired. DSA and C-arm CT examinations were reviewed by 2 investigators and correlated with IVUS. C-arm CT image quality was rated on a four-point scale. Doppler ultrasound was performed at 1-year follow-up. RESULTS: The ankle-brachial index was 0.69 ± 0.10 and 0.99 ± 0.40, respectively, pre- and post-procedure. C-arm CT imaging quality was rated as good or excellent in 80%. In-stent minimal luminal diameter (MLD) was evaluated at 4.71 ± 0.7 mm on DSA, 3.39 ± 0.6 mm on IVUS, and 3.12 ± 0.9 mm on C-arm CT. Compared to IVUS, DSA demonstrated an overestimation of MLD (p = 0.0001), an underestimation of ISE (DSA = 18.8% ± 7.6; IVUS = 29.8% ± 9) (p < 0.0001), and a poor inter-technique intra-class correlation coefficient (ICC = 0.24). No difference was observed between IVUS and C-arm CT in ISE as calculated by diameter (29.8 ± 9 vs. 28.2 ± 12.5%, p = 0.5) and area (30.2 ± 8.4 vs. 33.3 ± 9.5%, p = 0.2). Inter-technique ICC between C-arm CT and IVUS was 0.72 [95%CI 0.49; 0.85] for MLA measurements. The inter-observer ICC for MLD and MLA measurements on C-arm CT were, respectively, estimated at 0.75 [95% CI 0.40, 0.89] and 0.77 [95% CI 0.43, 0.90)]. CONCLUSIONS: C-arm CT presents a better correlation with IVUS than DSA to determine lumen diameter and ISE immediately after percutaneous revascularization.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Arteria Femoral/diagnóstico por imagen , Arteria Poplítea/diagnóstico por imagen , Radiografía Intervencional , Stents , Tomografía Computarizada por Rayos X/métodos , Anciano , Angiografía de Substracción Digital , Índice Tobillo Braquial , Arteriopatías Oclusivas/diagnóstico por imagen , Femenino , Arteria Femoral/cirugía , Estudios de Seguimiento , Humanos , Masculino , Arteria Poplítea/cirugía , Estudios Prospectivos , Reproducibilidad de los Resultados , Ultrasonografía Intervencional
20.
Radiology ; 277(3): 887-94, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26020437

RESUMEN

PURPOSE: To assess the sensitivity and specificity for ratios of adrenal vein cortisol level (Ca) to peripheral vein cortisol level (Cp), adrenal vein aldosterone level (Aa) to peripheral vein aldosterone level (Ap), and combined cortisol and aldosterone levels ("combined ratio") for the detection of successful adrenal vein catheterization ("selectivity") in adrenal vein sampling (AVS) without adrenocorticotropic hormone (ACTH) injection at different cutoff values. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and informed consent was waived. AVS was performed in 160 consecutive patients (49 women and 111 men; mean age, 53.6 years) between December 1989 and January 2014. Cortisol and aldosterone levels were measured in samples from the adrenal veins and left iliac vein every 5 minutes, two times before (basal) and three times after intravenous cosyntropin (ACTH 1-24) injection. Selectivity was defined by Ca/Cp or Aa/Ap ratio of at least 5 in at least one sampling after ACTH administration. Sensitivity and specificity for the detection of selective adrenal vein catheterization were calculated for basal Ca/Cp ratio, Aa/Ap ratio, and combined ratios for three cutoff values reported in the literature. The McNemar test was used to assess differences in sensitivity and specificity to detect selective adrenal vein catheterization. RESULTS: The sensitivity and specificity for the cutoff values of at least 3, at least 2, and at least 1.1 for the detection of AVS selectivity were respectively 50.4% and 100%, 70.8% and 100%, and 98.5% and 76.9% for Ca/Cp ratio; 61.3% and 100%, 70.8% and 100%, and 94.2% and 53.8% for Aa/Ap ratio; and 75.2% and 100%, 88.3% and 100%, and 99.3% and 46.2% for combined ratios (sensitivity at the ≥2 cutoff value: P < .0001 for combined ratio vs Ca/Cp ratio and for combined ratio vs Aa/Ap ratio). CONCLUSION: Basal combined ratio has the best sensitivity for the detection of AVS selectivity at all cutoff values, and for all ratios, the cutoff value of at least 2 has the best sensitivity for 100% specificity.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Aldosterona/sangre , Cateterismo Periférico/métodos , Hidrocortisona/sangre , Hiperaldosteronismo/sangre , Hormona Adrenocorticotrópica/farmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Venas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...