Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Neurogastroenterol Motil ; : e14859, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38988105

RESUMEN

BACKGROUND: Esophagogastric junction outflow obstruction (EGJOO) is a heterogenous disorder in which the correct management strategy is unclear. We assessed whether functional lumen imaging probe (FLIP) topography data could select EGJOO, which would benefit from lower esophageal sphincter Botulinum toxin (Botox) injection. METHODS: This was a single-center prospective study of adult patients meeting Chicago Classification (CC) v3.0 criteria for EGJOO. We assessed differences in pretreatment physiologic measurements on high-resolution manometry (HRM) and FLIP and other relevant clinical variables in predicting Botox response (>50% in BEDQ at 2 months). KEY RESULTS: Sixty-nine patients were included (ages 33-90, 73.9% female). Of these, 42 (61%) were Botox responders. Majority of physiologic measures on HRM and FLIP and esophageal emptying were not different based on Botox response. However, a spastic-reactive (SR) FLIP contractile response (CR) pattern predicted a Botox response with OR 25.6 (CI 2.9-229.6) when compared to antegrade FLIP CR; and OR for impaired-disordered/absent CR was 22.5 (CI 2.5-206.7). Logistic regression model using backward elimination (p value = 0.0001, AUC 0.79) showed that a SRCR or IDCR/absent response and the upright IRP predicted Botox response. Response rates in tiered diagnostic groups were: (i) CCv3.0 EGJOO (60.9%), (ii) CCv4.0 EGJOO (73.1%), (iii) CCv4.0 + FLIP REO (80%), (iv) CCv4.0, FLIP REO, and abnormal FLIP CR (84.2%), and (v) CCv4.0, FLIP REO, and SR FLIP CR (90%). CONCLUSIONS AND INFERENCES: FLIP helps identify patients with EGJOO who are likely to response to LES Botox therapy. An abnormal FLIP contractile response pattern is the single-most important predictor of a Botox response.

2.
Surg Endosc ; 38(1): 291-299, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37991572

RESUMEN

BACKGROUND: Multiple factors contribute to symptom generation and treatment response in proton-pump inhibitor non-responders (PPI-NRs). We aimed to test whether PPI-NRs with normal acid exposure have a higher degree of esophageal hypersensitivity and hypervigilance and can be identified using functional lumen imaging probe (FLIP) topography at the time of endoscopy. METHODS: Data from PPI-NRs whom underwent endoscopy, FLIP and wireless 96-h pH-metry were retrospectively analyzed. Patients were grouped according to acid exposure time (AET) as (a) 0 days abnormal (AET > 6%), (b) 1-2 days abnormal, or (c) 3-4 days abnormal. The esophageal hypervigilance and anxiety scale (EHAS) score and other symptom scores were compared between groups. The discriminatory ability of the esophagogastric junction (EGJ) distensibility index (DI) and max EGJ diameter in identifying patients with 0 days abnormal AET was tested via receiver-operating-characteristic (ROC) curve analysis. RESULTS: EHAS score was 38.6 in the 0 days abnormal AET group, 30.4 in the 1-2 days abnormal AET group (p = 0.073 when compared to 0 days abnormal) and 28.2 in the 3-4 days abnormal AET group (p = 0.031 when compared to 0 days abnormal). Area-under-the-curve (AUC) for the DI in association with 0 days AET > 6% was 0.629. A DI of < 2.8 mm2/mmHg had a sensitivity of 83.3%, and negative predictive value of 88% in classifying patients with 0 days abnormal acid exposure (p = 0.004). CONCLUSIONS: FLIP complements prolonged wireless pH-metry in distinguishing the subset of PPI-NRs with completely normal acid exposure and a higher burden of esophageal hypervigilance. Proper identification of patients along the functional heartburn spectrum can improve overall surgical outcomes.


Asunto(s)
Reflujo Gastroesofágico , Humanos , Reflujo Gastroesofágico/diagnóstico , Reflujo Gastroesofágico/tratamiento farmacológico , Reflujo Gastroesofágico/complicaciones , Inhibidores de la Bomba de Protones/uso terapéutico , Estudios Retrospectivos , Monitorización del pH Esofágico/métodos
3.
Gastrointest Endosc ; 97(2): 251-259, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36228696

RESUMEN

BACKGROUND AND AIMS: Treatment options for nonachalasia obstructive disorders of the esophagogastric junction (EGJ) are limited. The aim of this study was to assess the treatment efficacy of pneumatic dilation (PD) for the disorders of EGJ outflow obstruction (EGJOO) and postfundoplication EGJ obstruction (PF-EGJO) and to assess attitudes regarding training in PD. METHODS: This was a 2-part study. The main study was a prospective, single-center study comparing treatment outcomes after PD in patients with EGJOO and PF-EGJO, defined using manometry criteria, versus achalasia. Treatment success was defined as a post-PD Eckardt score (ES) of ≤2 at the longest duration of follow-up available. In a substudy, a 2-question survey was sent to 78 advanced endoscopy fellowship sites in the United States regarding training in PD. RESULTS: Of the 58% of respondents to the advanced endoscopy program director survey, two-thirds reported no training in PD at their program. The primary rationale cited was lack of a clinical need for PD. Sixty-one patients (15 achalasia, 32 EGJOO, and 14 PF-EGJO) were included in the main study with outcomes available at a mean follow-up of 8.8 months. Overall, mean ES decreased from 6.30 to 2.89 (P < .0001), and a mean percentage of improvement in symptoms reported by patients was 55.3%. ES ≤2 was achieved by 33 of 61 patients (54.1%). CONCLUSIONS: PD is an effective treatment for the nonachalasia obstructive disorders of the EGJ. There may be a current gap in training and technical expertise in PD.


Asunto(s)
Acalasia del Esófago , Trastornos de la Motilidad Esofágica , Humanos , Estudios Prospectivos , Dilatación , Unión Esofagogástrica , Manometría
4.
Neurogastroenterol Motil ; 34(8): e14319, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35060256

RESUMEN

BACKGROUND: It is debated whether high-resolution manometric (HRM) integrated relaxation pressure (IRP) or functional lumen imaging probe (FLIP) distensibility index (DI) is the superior measure of esophagogastric junction (EGJ) opening. We examined the relationship between the DI and IRP and assessed correlations with dysphagia symptoms in patients with achalasia and EGJ outflow obstruction (EGJOO). METHODS: Patients with achalasia and those with barium tablet retention at the EGJ were grouped as follows: Group 1:Achalasia (IRP ≥ 15 mmHg + complete absence of normal peristalsis); Group 2: Manometric +FLIP EGJOO (IRP ≥ 15 mmHg with some intact peristalsis + DI ≤ 2.8 mm2 /mmHg); Group 3: Abnormal DI only (DI ≤ 2.8 mm2 /mmHg + IRP <15 mmHg); and Group 4: Normal IRP and DI (IRP ≥ 15 mmHg + DI > 2.8 mm2 /mmHg). Correlation between the DI, baseline lower esophageal sphincter pressure (BLESP), IRP, and dysphagia (Eckardt score) was assessed. Multivariable analysis was used to assess variables associated with dysphagia score ≥2. KEY RESULTS: A total of 79 patients were included: Group 1 (n = 31), Group 2 (n = 33), Group 3 (n = 14), and Group 4 (n = 1). DI did not correlate with BLESP or IRP in the whole sample or subgroups. DI was the only variable associated with dysphagia score ≥2 (p = 0.006). DI < 1.25 mm2 /mmHg had sensitivity of 87% and specificity of 52% (p = 0.0003) for dysphagia score ≥2. CONCLUSIONS & INFERENCES: DI does not correlate with HRM EGJ measurements and is the metric with the strongest effect on dysphagia severity. The various biological elements that may cause restrictive EGJ function should be the subject of future studies.


Asunto(s)
Trastornos de Deglución , Acalasia del Esófago , Acalasia del Esófago/complicaciones , Acalasia del Esófago/diagnóstico , Esfínter Esofágico Inferior , Unión Esofagogástrica , Humanos , Manometría/métodos
5.
Surg Endosc ; 35(8): 4418-4426, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32880014

RESUMEN

BACKGROUND: Esophagogastric junction obstruction (EGJO) post-fundoplication (PF) is difficult to identify with currently available tests. We aimed to assess the diagnostic accuracy of EGJ opening on functional lumen imaging probe (FLIP) and dilation outcome in FLIP-detected EGJO in PF dysphagia. METHODS: We prospectively collected data on PF patients referred to Esophageal Clinic over 18 months. EGJO diagnosis was made by (a) endoscopist's description of a narrow EGJ/wrap area, (b) appearance of wrap obstruction or contrast/tablet retention on esophagram, or (c) EGJ-distensibility index (DI) < 2.8 mm2/mmHg on real-time FLIP. In patients with EGJO and dysphagia, EGJ dilation was performed to 20 mm, 30 mm, or 35 mm in a stepwise fashion. Outcome was assessed as % dysphagia improvement during phone call or on brief esophageal dysphagia questionnaire (BEDQ) score. RESULTS: Twenty-six patients were included, of whom 17 (65%) had a low EGJ-DI. No patients had a hiatal hernia greater than 3 cm. Dysphagia was the primary symptom in 17/26 (65%). In 85% (κ = 0.677) of cases, EGJ assessment (tight vs. open) was congruent between the combination of endoscopy (n = 26) and esophagram (n = 21) vs. EGJ-DI (n = 26) on FLIP. Follow-up data were available in 11 patients who had dilation based on a low EGJ-DI (4 with 20 mm balloon and 7 with ≥ 30 mm balloon). Overall, the mean % improvement in dysphagia was 60% (95% CI 37.7-82.3%, p = 0.0001). Nine out of 11 patients, including 6 out of 7 undergoing pneumatic dilation, had improvement ≥ 50% in dysphagia (mean % improvement 72.2%; 95% CI 56.1-88.4%, p = 0.0001). CONCLUSIONS AND INFERENCES: Functional lumen imaging probe is an accurate modality for evaluating for EGJ obstruction PF. FLIP may be used to select patients who may benefit from larger diameter dilation.


Asunto(s)
Trastornos de Deglución , Acalasia del Esófago , Trastornos de Deglución/etiología , Unión Esofagogástrica/diagnóstico por imagen , Fundoplicación , Humanos , Manometría
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...