1.
Phys Med Biol ; 66(3): 035005, 2021 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-33142278

RESUMEN

In both the International Commission on Radiological Protection (ICRP) and Medical Internal Radiation Dose (MIRD) schemata of internal dosimetry, the S-value is defined as the absorbed dose to a target organ per nuclear decay of the radionuclide in a source organ. Its computation requires data on the energies and yields of all radiation emissions from radionuclide decay, the mass of the target organ, and the value of the absorbed fraction-the fraction of particle energy emitted in the source organ that is deposited in the target organ. The specific absorbed fraction (SAF) is given as the ratio of the absorbed fraction and the target mass. Historically, in the early development of both schemata, computational simplifications were made to the absorbed fraction in considering both organ self-dose ([Formula: see text]) and organ cross-dose ([Formula: see text]). In particular, the value of the absorbed fraction was set to unity for all 'non-penetrating' particle emissions (electrons and alpha particles) such that they contributed only to organ self-dose. As radiation transport codes for charged particles became more widely available, it became increasingly possible to abandon this distinction and to explicitly consider the transport of internally emitted electrons in a manner analogous to that for photons. In this present study, we report on an extensive series of electron SAFs computed in a revised series of the UF/NCI pediatric phantoms. A total of 28 electron energies-0-10 MeV-along a logarithmic energy grid are provided in electronic annexes, where 0 keV is associated with limiting values of the SAF. Electron SAFs were computed independently for collisional energy losses (SAFCEL) and radiation energy losses (SAFREL) to the target organ. A methodology was employed in which values of SAFREL were compiled by first assembling organ-specific and electron energy-specific bremsstrahlung x-ray spectra, and then using these x-ray spectra to re-weight a previously established monoenergetic database of photon SAFs for all phantoms and source-target combinations. Age-dependent trends in the electron SAF were demonstrated for the majority of the source-target organ pairs, and were consistent to values given for the ICRP adult phantoms. In selected cases, however, anticipated age-dependent trends were not seen, and were attributed to anatomical differences in relative organ positioning at specific phantom ages. Both the electron SAFs of this study, and the photon SAFs from our companion study, are presently being used by ICRP Committee 2 in its upcoming pediatric extension to ICRP Publication 133.


Asunto(s)
Electrones , National Cancer Institute (U.S.)/normas , Fantasmas de Imagen , Fotones , Radiometría/instrumentación , Adulto , Niño , Humanos , Masculino , Método de Montecarlo , Dosis de Radiación , Estados Unidos
2.
Phys Med Biol ; 66(3): 035006, 2021 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-33142280

RESUMEN

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction-fraction of particle energy emitted in the source tissue that is deposited in the target tissue-and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series-male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old-for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source-target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log-log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. The results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.


Asunto(s)
National Cancer Institute (U.S.)/normas , Fantasmas de Imagen , Fotones , Radiometría/instrumentación , Adulto , Algoritmos , Niño , Preescolar , Electrones , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Método de Montecarlo , Dosis de Radiación , Estados Unidos
3.
Phys Med Biol ; 63(15): 155022, 2018 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-29999494

RESUMEN

Estimates of regional blood volumes (BVs) in humans are needed in dosimetric models of radionuclides and radiopharmaceuticals that decay in the circulation to a significant extent. These values are also needed to refine models of tissue elemental composition in computational human phantoms of both patients and exposed members of the general public. The International Commission on Radiological Protection (ICRP) in its Publication 89 provides reference values for total blood content in the full series of their reference individuals, to include the male and female newborn, 1 year-old, 5 year-old, 10 year-old, 15 year-old, and adult. Furthermore, Publication 89 provides reference values for the percentage distribution of total blood volume in 27 different blood-filled organs and tissues of the reference adult male and adult female. However, no similar distribution values are provided for non-adults. The goal of the present study is to present a volumetric scaling methodology to derive these values for the same organs and tissues at ages younger than the reference adult. Literature data on organ-specific vascular growth in the brain, kidneys, and skeletal tissues are also considered.


Asunto(s)
Volumen Sanguíneo , Órganos en Riesgo/efectos de la radiación , Protección Radiológica/normas , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Órganos en Riesgo/irrigación sanguínea , Fantasmas de Imagen , Guías de Práctica Clínica como Asunto , Radiometría/métodos , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA