Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 11(1): 17492, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34471205

RESUMEN

External ventricular drainage (EVD) is an emergency neurosurgical procedure to decrease intracranial pressure through a catheter mediated drainage of cerebrospinal fluid. Most EVD catheters are placed using free hands without direct visualization of the target and catheter trajectory, leading to a high rate of complications- hemorrhage, brain injury and suboptimal catheter placement. Use of stereotactic systems can prevent these complications. However, they have found limited application for this procedure due to their long set-up time and expensive hardware. Therefore, we have developed and pre-clinically validated a novel 3D printed stereotactic system for rapid and accurate implantation of EVD catheters. Its mechanical and imaging accuracies were found to be at par with clinical stereotactic systems. Preclinical trial in human cadaver specimens revealed improved targeting accuracy achieved within an acceptable time frame compared to the free hand technique. CT angiography emulated using cadaver specimen with radio-opaque vascular contrast showed vessel free catheter trajectory. This could potentially translate to reduced hemorrhage rate. Thus, our 3D printed stereotactic system offers the potential to improve the accuracy and safety of EVD catheter placement for patients without significantly increasing the procedure time.


Asunto(s)
Drenaje/métodos , Hipertensión Intracraneal/cirugía , Procedimientos Neuroquirúrgicos/métodos , Técnicas Estereotáxicas , Humanos , Hipertensión Intracraneal/diagnóstico por imagen , Tomografía Computarizada por Rayos X
2.
J Neural Eng ; 17(6)2020 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-33142275

RESUMEN

Objective. Stereotactic technology enables fine navigation to small structures in the human body. While current stereotactic systems facilitate accurate targeting, they are mechanically cumbersome and limited in scope. Here, we hypothesized that a stereotactic system could be developed with a reduced footprint while maintaining broad targeting capabilities in order to improve versatility in frame placement location and surgical workflow.Approach. We designed a stereotactic system around the center-of-arc principle, with mechanical properties that would enable a compact design and ample targeting and trajectory maneuverability. To examine the opportunity for a low-cost rapidly-deployable system we developed two fabrication variants, one using three dimensional (3D)-printing and the other using conventional machining. Mechanical and image-guided accuracies were tested in phantom studies using magnetic resonance imaging (MRI) and computed tomography. Using human cadaver head specimens, we assessed the system's surgical workflow and its ability to reliably and accurately implant electrodes in deep brain stimulation (DBS) surgery.Main results. We developed a small 7.7 × 5.4 cm2device platform that rigidly mounts to curvilinear bone and supports the attachment of surgical instrumentation. Attachment of two surgical instruments, an imaging localizer and a compact targeting device, demonstrated successful MRI-guided intervention in phantom studies with a vector error of 1.79 ± 0.41 mm. Evaluation of the 3D-printed system for DBS surgery confirmed ease of device platform attachment and instrument functionality, as well as demonstrated a surgical targeting accuracy of 1.83 ± 0.15 mm. In addition, we found the surgical time to be 78.3 ± 5.4 min for bilateral electrode implantation.Significance. We developed a light and compact stereotactic system whose accuracy is on par with those used clinically. This technology is suitable for clinical translation and its flexibility in positioning will seamlessly expand the capabilities for stereotaxy to treat a wide range of conditions, both within neurosurgery and beyond.


Asunto(s)
Estimulación Encefálica Profunda , Imagenología Tridimensional , Estimulación Encefálica Profunda/métodos , Humanos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Procedimientos Neuroquirúrgicos , Fantasmas de Imagen , Técnicas Estereotáxicas , Tomografía Computarizada por Rayos X
3.
J Neural Eng ; 15(6): 066003, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30124202

RESUMEN

OBJECTIVE: Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. APPROACH: We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. MAIN RESULTS: Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm (p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. SIGNIFICANCE: Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Neuronavegación/instrumentación , Técnicas Estereotáxicas/instrumentación , Animales , Tornillos Óseos , Cadáver , Estimulación Encefálica Profunda , Equipo Reutilizado , Humanos , Imagen por Resonancia Magnética/métodos , Neuronavegación/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Cirugía Asistida por Computador/instrumentación , Porcinos , Tomografía Computarizada por Rayos X
4.
Spine (Phila Pa 1976) ; 41(13): E806-E813, 2016 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-26679880

RESUMEN

STUDY DESIGN: Laboratory/animal-based proof of principle study. OBJECTIVE: To validate the accuracy of a magnetic resonance imaging (MRI)-guided stereotactic system for intraspinal electrode targeting and demonstrate the feasibility of such a system for controlling implantation of intraspinal electrodes. SUMMARY OF BACKGROUND DATA: Intraspinal microstimulation (ISMS) is an emerging preclinical therapy, which has shown promise for the restoration of motor function following spinal cord injury. However, targeting inaccuracy associated with existing electrode implantation techniques remains a major barrier preventing clinical translation of ISMS. METHODS: System accuracy was evaluated using a test phantom comprised of nine target locations. Targeting accuracy was determined by calculating the root mean square error between MRI-generated coordinates and actual frame coordinates required to reach the target positions. System performance was further validated in an anesthetized pig model by performing MRI-guided intraspinal electrode implantation and stimulation followed by computed tomography of electrode location. Finally, system compatibility with a commercially available microelectrode array was demonstrated by implanting the array and applying a selection of stimulation amplitudes that evoked hind limb responses. RESULTS: The root mean square error between actual frame coordinates and software coordinates, both acquired using the test phantom, was 1.09 ±â€Š0.20 mm. Postoperative computed tomography in the anesthetized pig confirmed spatially accurate electrode placement relative to preoperative MRI. Additionally, MRI-guided delivery of a microwire electrode followed by ISMS evoked repeatable electromyography responses in the biceps femoris muscle. Finally, delivery of a microelectrode array produced repeatable and graded hind limb evoked movements. CONCLUSION: We present a novel frame-based stereotactic system for targeting and delivery of intraspinal instrumentation. This system utilizes MRI guidance to account for variations in anatomy between subjects, thereby improving upon existing ISMS electrode implantation techniques. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Electrodos Implantados , Imagen por Resonancia Magnética/métodos , Médula Espinal/diagnóstico por imagen , Técnicas Estereotáxicas , Animales , Imagen por Resonancia Magnética/instrumentación , Masculino , Microelectrodos , Traumatismos de la Médula Espinal/diagnóstico por imagen , Traumatismos de la Médula Espinal/terapia , Técnicas Estereotáxicas/instrumentación , Porcinos
5.
Epilepsia ; 55(2): 233-44, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24483230

RESUMEN

OBJECTIVE: Seizures are currently defined by their electrographic features. However, neuronal networks are intrinsically dependent on neurotransmitters of which little is known regarding their periictal dynamics. Evidence supports adenosine as having a prominent role in seizure termination, as its administration can terminate and reduce seizures in animal models. Furthermore, microdialysis studies in humans suggest that adenosine is elevated periictally, but the relationship to the seizure is obscured by its temporal measurement limitations. Because electrochemical techniques can provide vastly superior temporal resolution, we test the hypothesis that extracellular adenosine concentrations rise during seizure termination in an animal model and humans using electrochemistry. METHODS: White farm swine (n = 45) were used in an acute cortical model of epilepsy, and 10 human epilepsy patients were studied during intraoperative electrocorticography (ECoG). Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS)-based fast scan cyclic voltammetry (FSCV) and fixed potential amperometry were obtained utilizing an adenosine-specific triangular waveform or biosensors, respectively. RESULTS: Simultaneous ECoG and electrochemistry demonstrated an average adenosine increase of 260% compared to baseline, at 7.5 ± 16.9 s with amperometry (n = 75 events) and 2.6 ± 11.2 s with FSCV (n = 15 events) prior to electrographic seizure termination. In agreement with these animal data, adenosine elevation prior to seizure termination in a human patient utilizing FSCV was also seen. SIGNIFICANCE: Simultaneous ECoG and electrochemical recording supports the hypothesis that adenosine rises prior to seizure termination, suggesting that adenosine itself may be responsible for seizure termination. Future work using intraoperative WINCS-based FSCV recording may help to elucidate the precise relationship between adenosine and seizure termination.


Asunto(s)
Adenosina/biosíntesis , Corteza Cerebral/metabolismo , Líquido Extracelular/metabolismo , Convulsiones/metabolismo , Adulto , Animales , Corteza Cerebral/fisiología , Electroencefalografía/métodos , Líquido Extracelular/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Convulsiones/diagnóstico , Convulsiones/fisiopatología , Porcinos , Adulto Joven
6.
J Clin Neurosci ; 20(11): 1520-6, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23906524

RESUMEN

Deep brain stimulation (DBS) has emerged as a viable therapy for Parkinson's disease (PD). The impact of subthalamic nucleus (STN) lead placement (lateral versus medial) on motor outcome, however, has not been systematically evaluated. Forty-eight patients with PD underwent STN-DBS surgery and were evaluated postoperatively for 48 weeks for motor improvement as measured by the Unified Parkinson's Disease Rating Scale (UPDRS) part III (standardized motor examination) and levodopa equivalent daily dose (LEDD). Postoperative MRI was used to identify the location of the active stimulating contact and motor outcome was analyzed. STN-DBS was associated with significant improvement in motor outcome as determined by a reduction in the UPDRS part III subscore from 34.44 ± 1.29 at baseline to 18.76 ± 1.06 at end visit (p<0.0001) and a reduction in LEDD from 1721 ± 152 mg/day at baseline to 1134 ± 119 mg/day at end visit (p=0.0024). Patients with stimulating contacts in the medial STN compared to the lateral STN did not demonstrate any significant differences in motor outcome (UPDRS, p=0.5811; LEDD, p=0.7341). No significant differences were found in motor outcome between patients with STN stimulation compared to stimulation of surrounding fiber tracts (p=0.80). No significant difference in stimulation voltage was noted with respect to lead location. Our study did not find a significant effect for the location of active contact and motor outcome neither within the subregions of the STN nor between the STN and surrounding fibers. Further research is needed to better understand the neurophysiological basis for these results.


Asunto(s)
Estimulación Encefálica Profunda/métodos , Electrodos Implantados , Enfermedad de Parkinson/terapia , Núcleo Subtalámico , Anciano , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Actividad Motora/fisiología , Resultado del Tratamiento
7.
Brain ; 136(Pt 8): 2444-56, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23803305

RESUMEN

Eleven patients being evaluated with intracranial electroencephalography for medically resistant temporal lobe epilepsy participated in a visual recognition memory task. Interictal epileptiform spikes were manually marked and their rate of occurrence compared between baseline and three 2 s periods spanning a 6 s viewing period. During successful, but not unsuccessful, encoding of the images there was a significant reduction in interictal epileptiform spike rate in the amygdala, hippocampus, and temporal cortex. During the earliest encoding period (0-2000 ms after image presentation) in these trials there was a widespread decrease in the power of theta, alpha and beta band local field potential oscillations that coincided with emergent focal gamma frequency activity. Interictal epileptiform spike rate correlated with spectral band power changes and broadband (4-150 Hz) desynchronization, which predicted significant reduction in interictal epileptiform spike rate. Spike-triggered averaging of the field potential power spectrum detected a burst of low frequency synchronization 200 ms before the interictal epileptiform spikes that arose during this period of encoding. We conclude that interictal epileptiform spikes are modulated by the patterns of network oscillatory activity that accompany human memory offering a new mechanistic insight into the interplay of cognitive processing, local field potential dynamics and interictal epileptiform spike generation.


Asunto(s)
Amígdala del Cerebelo/fisiopatología , Epilepsia del Lóbulo Temporal/fisiopatología , Hipocampo/fisiopatología , Memoria/fisiología , Red Nerviosa/fisiopatología , Lóbulo Temporal/fisiopatología , Adulto , Mapeo Encefálico , Electroencefalografía , Humanos , Pruebas Neuropsicológicas , Reconocimiento en Psicología/fisiología
8.
Magn Reson Imaging ; 31(5): 783-8, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23228310

RESUMEN

PURPOSE: To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS: DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR GRE EPI and IR-prepped GRE sequences (SAR: 0.42 and 0.39 W/kg, respectively), and the high-SAR 4-echo RF spin echo (SAR: 2.9 W/kg). Fluoroptic thermometry was used to directly measure RF-related heating at the DBS electrodes, and at the implantable pulse generator (IPG). For reference the measurements were repeated in the same pig at 1.5 T and, at both field strengths, in a phantom. RESULTS: At 3.0T, the maximal temperature elevations at DBS electrodes were 0.46 °C and 2.3 °C, for the low- and high-SAR sequences, respectively. No heating was observed on the implanted IPG during any of the measurements. Measurements of in vivo heating differed from those obtained in the phantom. CONCLUSION: The 3.0-T MRI using GRE EPI and IR-prepped GRE sequences resulted in local temperature elevations at DBS electrodes of no more than 0.46 °C. Although no extrapolation should be made to human exams and much further study will be needed, these preliminary data are encouraging for the future use 3.0-T MRI in patients with DBS.


Asunto(s)
Temperatura Corporal/fisiología , Encéfalo/anatomía & histología , Encéfalo/fisiología , Estimulación Encefálica Profunda/instrumentación , Estimulación Encefálica Profunda/métodos , Imagen por Resonancia Magnética/métodos , Termografía/métodos , Animales , Temperatura Corporal/efectos de la radiación , Encéfalo/efectos de la radiación , Campos Magnéticos , Porcinos
9.
Neurosurgery ; 71(2 Suppl Operative): ons321-7; discussion ons327-8, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22843131

RESUMEN

BACKGROUND: Frameless stereotaxy commonly registers preoperative magnetic resonance imaging (MRI) to patients by using surface scalp anatomy or adhesive fiducial scalp markers. Patients' scalps may shift slightly between preoperative imaging and final surgical positioning with pinion placement, introducing error. This might be reduced when frameless stereotaxy is performed in a high-field intraoperative MRI (iMRI), as patients are positioned before imaging. This could potentially improve accuracy. OBJECTIVE: To compare frameless stereotactic accuracy using a high-field iMRI with that using standard preoperative MRI. METHODS: Data were obtained in 32 adult patients undergoing frameless stereotactic-guided brain tumor surgery. Stereotactic images were obtained with 1.5T MRI scanner either preoperatively (14 patients) or intraoperative (18 patients). System-generated accuracy measurements and distances from the actual center of each fiducial marker to that represented by neuronavigation were recorded. Finally, accuracy at multiple deep targets was assessed by using a life-sized human head stereotactic phantom in which fiducials were placed on deformable foam to mimic scalp. RESULTS: : System-generated accuracy measurements were significantly better for the iMRI group (mean ± SEM = 1.04 ± 0.05 mm) than for the standard group (1.82 ± 0.09 mm; P < .001). Measured distances from the actual center of scalp fiducial markers to that represented by neuronavigation were also significantly smaller for iMRI (1.72 ± 0.10 mm) in comparison with the standard group (3.17 ± 0.22 mm; P < .001). Deep accuracy in the phantom model was significantly better with iMRI (1.67 ± 0.12 mm) than standard imaging (2.28 ± 0.14 mm; P = .003). CONCLUSION: Frameless stereotactic accuracy is increased by using high-field iMRI compared with standard preoperative imaging.


Asunto(s)
Neoplasias Encefálicas/cirugía , Imagen por Resonancia Magnética/métodos , Neuronavegación/métodos , Radiocirugia/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
Mayo Clin Proc ; 87(8): 760-5, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22809886

RESUMEN

Essential tremor is often markedly reduced during deep brain stimulation simply by implanting the stimulating electrode before activating neurostimulation. Referred to as the microthalamotomy effect, the mechanisms of this unexpected consequence are thought to be related to microlesioning targeted brain tissue, that is, a microscopic version of tissue ablation in thalamotomy. An alternate possibility is that implanting the electrode induces immediate neurochemical release. Herein, we report the experiment performing with real-time fast-scan cyclic voltammetry to quantify neurotransmitter concentrations in human subjects with essential tremor during deep brain stimulation. The results show that the microthalamotomy effect is accompanied by local neurochemical changes, including adenosine release.


Asunto(s)
Adenosina/metabolismo , Estimulación Encefálica Profunda , Temblor Esencial/terapia , Anciano , Anciano de 80 o más Años , Encéfalo/patología , Técnicas Electroquímicas , Electroquímica , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Tecnología Inalámbrica
11.
Mayo Clin Proc ; 86(8): 721-9, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21803954

RESUMEN

OBJECTIVE: To review surgical results of endoscopic transthoracic limited sympathotomy for palmar-plantar hyperhidrosis during the past decade. PATIENTS AND METHODS: We retrospectively reviewed 155 consecutive patients who underwent surgery from June 30, 2000, through December 31, 2009, for medically refractory palmar-plantar hyperhidrosis using a technique of T1-T2 sympathotomy disconnection, designed for successful palmar response and minimization of complications. RESULTS: Of the 155 patients, 44 (28.4%) were male, and 111 (71.6%) were female; operative times averaged 38 minutes. No patient experienced Horner syndrome, intercostal neuralgia, or pneumothorax. The only surgical complication was hemothorax in 2 patients (1.3%); in 1 patient, it occurred immediately postoperatively and in the other patient, 10 days postoperatively; treatment in both patients was successful. All 155 patients had successful (warm and dry) palmar responses at discharge. Long-term follow-up (>3 months; mean, 40.2 months) was obtained for 148 patients (95.5%) with the following responses to surgery: 96.6% of patients experienced successful control of palmar sweating; 69.2% of patients experienced decreased axillary sweating; and 39.8% of patients experienced decreased plantar sweating. At follow-up, 5 patients had palmar sweating (3 patients, <3 months; 1 patient, 10-12 months; 1 patient, 16-18 months). Compensatory hyperhidrosis did not occur in 47 patients (31.7%); it was mild in 92 patients (62.2%), moderate in 7 patients (4.7%), and severe in 2 patients (1.3%). CONCLUSION: In this series, a small-diameter uniportal approach has eliminated intercostal neuralgia. Selecting a T1-T2 sympathotomy yields an excellent palmar response, with a very low severe compensatory hyperhidrosis complication rate. The low failure rate was noted during 18 months of follow-up and suggests that longer follow-up is necessary in these patients.


Asunto(s)
Dermatosis del Pie/cirugía , Ganglios Simpáticos/cirugía , Dermatosis de la Mano/cirugía , Hiperhidrosis/cirugía , Simpatectomía/estadística & datos numéricos , Toracoscopía/estadística & datos numéricos , Adulto , Anciano , Procedimientos Quirúrgicos Ambulatorios/estadística & datos numéricos , Causalidad , Comorbilidad , Femenino , Estudios de Seguimiento , Dermatosis del Pie/epidemiología , Respuesta Galvánica de la Piel , Dermatosis de la Mano/epidemiología , Hemotórax/epidemiología , Hemotórax/etiología , Humanos , Hiperhidrosis/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Temperatura Cutánea , Sudoración , Simpatectomía/efectos adversos , Toracoscopía/efectos adversos , Resultado del Tratamiento
12.
Epilepsia ; 52(6): e49-53, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21627648

RESUMEN

Focal cortical epilepsy is currently studied most effectively in humans. However, improvement in cortical monitoring and investigational device development is limited by lack of an animal model that mimics human acute focal cortical epileptiform activity under epilepsy surgery conditions. Therefore, we assessed the swine model for translational epilepsy research. Swine were used due to their cost-effectiveness, convoluted cortex, and comparative anatomy. The anatomy has all the same brain structures as the human, and in similar locations. Focal subcortical injection of benzyl-penicillin produced clinical seizures correlating with epileptiform activity demonstrating temporal and spatial progression. Swine were evaluated under five different anesthesia regimens. Of the five regimens, conditions similar to human intraoperative anesthesia, including continuous fentanyl with low dose isoflorane, was the most effective for eliciting complex, epileptiform activity after benzyl-penicillin injection. The most complex epileptiform activity (spikes, and high frequency activity) was then repeated reliably in nine animals, utilizing 14 swine total. There were 20.1 ± 10.8 [95% confidence interval (CI) 11.8-28.4] epileptiform events with > 3.5 Hz activity occurring per animal. Average duration of each event was 46.3 ± 15.6 (95% CI 44.0-48.6) s, ranging from 20-100 s. In conclusion, the acute swine model of focal cortical epilepsy surgery provides an animal model that mimics human surgical conditions with a large brain and gyrated cortex, and is relatively inexpensive among animal models. Therefore, we feel this model provides a valuable, reliable, and novel platform for translational studies of implantable hardware for intracranial monitoring.


Asunto(s)
Encéfalo/fisiopatología , Modelos Animales de Enfermedad , Electroencefalografía/métodos , Epilepsias Parciales/fisiopatología , Investigación Biomédica Traslacional/métodos , Animales , Electrodos Implantados , Electroencefalografía/instrumentación , Epilepsias Parciales/diagnóstico , Masculino , Porcinos
13.
World Neurosurg ; 73(5): 547-51, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20920940

RESUMEN

BACKGROUND: Awake craniotomy and electrophysiologic mapping (EPM) is an established technique to facilitate the resection of near eloquent cortex. Intraoperative magnetic resonance imaging (iMRI) is increasingly used to aid in the resection of intracranial lesions. Standard draping protocols in high-field iMRI units make awake craniotomies challenging, and only two groups have previously reported combined EPM and high-field iMRI. METHODS: We present an illustrative case describing a simple technique for combining awake craniotomy and EPM with high-field iMRI. A movable platter is used to transfer the patient from the operating table to a transport trolley and into the adjacent MRI and still maintaining the patient's surgical position. This system allows excess drapes to be removed, facilitating awake craniotomy. RESULTS: A 57-year-old right-handed man presented with new onset seizures. Magnetic resonance imaging demonstrated a large left temporal mass. The patient underwent an awake, left frontotemporal craniotomy. The EPM demonstrated a single critical area for speech in his inferior frontal gyrus. After an initial tumor debulking, the scalp flap was loosely approximated, the wound was covered with additional drapes, and the excess surrounding drapes were trimmed. An iMRI was obtained. The image-guidance system was re-registered and the patient was redraped. Additional resection was performed, allowing extensive removal of what proved to be an anaplastic astrocytoma. The patient tolerated this well without any new neurological deficits. CONCLUSIONS: Standard protocols for positioning and draping in high-field iMRI units make awake craniotomies problematic. This straightforward technique for combined awake EPM and iMRI may facilitate safe removal of large lesions in eloquent cortex.


Asunto(s)
Astrocitoma/patología , Astrocitoma/cirugía , Mapeo Encefálico/métodos , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/cirugía , Craneotomía/métodos , Electroencefalografía , Imagen por Resonancia Magnética/métodos , Cirugía Asistida por Computador/métodos , Anestesia , Lobectomía Temporal Anterior , Electrofisiología , Epilepsia Tónico-Clónica/complicaciones , Epilepsia Tónico-Clónica/cirugía , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Neuronavegación/métodos , Trastornos del Habla/etiología , Lóbulo Temporal/patología , Lóbulo Temporal/cirugía , Vigilia
14.
Neurosurg Focus ; 29(2): E6, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20672923

RESUMEN

Deep brain stimulation (DBS) is effective when there appears to be a distortion in the complex neurochemical circuitry of the brain. Currently, the mechanism of DBS is incompletely understood; however, it has been hypothesized that DBS evokes release of neurochemicals. Well-established chemical detection systems such as microdialysis and mass spectrometry are impractical if one is assessing changes that are happening on a second-to-second time scale or for chronically used implanted recordings, as would be required for DBS feedback. Electrochemical detection techniques such as fast-scan cyclic voltammetry (FSCV) and amperometry have until recently remained in the realm of basic science; however, it is enticing to apply these powerful recording technologies to clinical and translational applications. The Wireless Instantaneous Neurochemical Concentration Sensor (WINCS) currently is a research device designed for human use capable of in vivo FSCV and amperometry, sampling at subsecond time resolution. In this paper, the authors review recent advances in this electrochemical application to DBS technologies. The WINCS can detect dopamine, adenosine, and serotonin by FSCV. For example, FSCV is capable of detecting dopamine in the caudate evoked by stimulation of the subthalamic nucleus/substantia nigra in pig and rat models of DBS. It is further capable of detecting dopamine by amperometry and, when used with enzyme linked sensors, both glutamate and adenosine. In conclusion, WINCS is a highly versatile instrument that allows near real-time (millisecond) detection of neurochemicals important to DBS research. In the future, the neurochemical changes detected using WINCS may be important as surrogate markers for proper DBS placement as well as the sensor component for a "smart" DBS system with electrochemical feedback that allows automatic modulation of stimulation parameters. Current work is under way to establish WINCS use in humans.


Asunto(s)
Técnicas Biosensibles/métodos , Encéfalo/metabolismo , Estimulación Encefálica Profunda/métodos , Técnicas Electroquímicas/métodos , Retroalimentación , Monitoreo Intraoperatorio/métodos , Telemetría/métodos , Adenosina/metabolismo , Animales , Técnicas Biosensibles/instrumentación , Estimulación Encefálica Profunda/instrumentación , Dopamina/metabolismo , Técnicas Electroquímicas/instrumentación , Ácido Glutámico/metabolismo , Humanos , Modelos Animales , Monitoreo Intraoperatorio/instrumentación , Ratas , Serotonina/metabolismo , Núcleo Subtalámico/metabolismo , Núcleo Subtalámico/fisiología , Porcinos , Telemetría/instrumentación
15.
Neurosci Lett ; 475(3): 136-40, 2010 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-20347936

RESUMEN

Subthalamic nucleus deep brain stimulation (STN DBS) ameliorates motor symptoms of Parkinson's disease, but the precise mechanism is still unknown. Here, using a large animal (pig) model of human STN DBS neurosurgery, we utilized fast-scan cyclic voltammetry in combination with a carbon-fiber microelectrode (CFM) implanted into the striatum to monitor dopamine release evoked by electrical stimulation at a human DBS electrode (Medtronic 3389) that was stereotactically implanted into the STN using MRI and electrophysiological guidance. STN electrical stimulation elicited a stimulus time-locked increase in striatal dopamine release that was both stimulus intensity- and frequency-dependent. Intensity-dependent (1-7V) increases in evoked dopamine release exhibited a sigmoidal pattern attaining a plateau between 5 and 7V of stimulation, while frequency-dependent dopamine release exhibited a linear increase from 60 to 120Hz and attained a plateau thereafter (120-240Hz). Unlike previous rodent models of STN DBS, optimal dopamine release in the striatum of the pig was obtained with stimulation frequencies that fell well within the therapeutically effective frequency range of human DBS (120-180Hz). These results highlight the critical importance of utilizing a large animal model that more closely represents implanted DBS electrode configurations and human neuroanatomy to study neurotransmission evoked by STN DBS. Taken together, these results support a dopamine neuronal activation hypothesis suggesting that STN DBS evokes striatal dopamine release by stimulation of nigrostriatal dopaminergic neurons.


Asunto(s)
Cuerpo Estriado/metabolismo , Estimulación Encefálica Profunda , Dopamina/metabolismo , Núcleo Subtalámico/fisiología , Animales , Estimulación Eléctrica , Masculino , Modelos Animales , Porcinos
16.
Surg Neurol ; 71(3): 388-90, discussion 391, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18291447

RESUMEN

BACKGROUND: Percutaneous balloon compression of the gasserian ganglion is an effective management of trigeminal neuralgia and is the only percutaneous procedure that preferentially may be performed under general anesthesia. However, the anatomy of Meckle's cave dictates the degree of compression, and if capacious, the usual smaller balloons may fail to adequately compress the ganglion. METHODS: We designed a series of larger cannulas, placed over a guidewire technique for using larger balloons, or even multiple balloons, to increase the applicability of this technique in these patients. RESULTS: In select cases, where smaller balloons fail to distort and deform the ganglion, with resultant poor clinical results, larger or multiple balloons may produce the desired response of pain relief. CONCLUSION: This technique is an added resource in managing this condition.


Asunto(s)
Cateterismo/instrumentación , Procedimientos Neuroquirúrgicos/instrumentación , Procedimientos Neuroquirúrgicos/métodos , Ganglio del Trigémino/cirugía , Neuralgia del Trigémino/cirugía , Cateterismo/métodos , Diseño de Equipo , Equipo Reutilizado , Fluoroscopía , Humanos , Ganglio del Trigémino/diagnóstico por imagen , Neuralgia del Trigémino/diagnóstico por imagen
17.
J Neurosurg ; 97(2): 401-7, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12186469

RESUMEN

OBJECT: Predicting which patients with aneurysmal subarachnoid hemorrhage (SAH) will develop delayed ischemic neurological deficit (DIND) due to vasospasm remains subjective and unreliable. The authors analyzed the utility of a novel software-based technique to quantify hemorrhage volume in patients with Fisher Grade 3 aneurysmal SAH. METHODS: Patients with aneurysmal SAH in whom a computerized tomography (CT) scan was performed within 72 hours of ictus and demonstrated Fisher Grade 3 SAH were analyzed. Severe DIND was defined as new onset complete focal deficit or coma. Moderate DIND was defined as new onset partial focal deficit or impaired consciousness without coma. Fifteen consecutive patients with severe DIND, 13 consecutive patients with moderate DIND, and 12 consecutive patients without DIND were analyzed. Software-based volumetric quantification was performed on digitized admission CT scans by a single examiner blinded to clinical information. There was no significant difference in age, sex, admission Hunt and Hess grade, or time to admission CT scan among the three groups (none, moderate, or severe DIND). Patients with severe DIND had a significantly higher cisternal volume of hemorrhage (median 30.5 cm3) than patients with moderate DIND (median 12.4 cm3) and patients without DIND (median 10.3 cm3; p < 0.001). Intraparenchymal hemorrhage and intraventricular hemorrhage were not associated with DIND. All 13 patients with cisternal volumes greater than 20 cm3 developed DIND, compared with 15 of 27 patients with volumes less than 20 cm3 (p = 0.004). CONCLUSIONS: The authors developed a simple and potentially widely applicable method to quantify SAH on CT scans. A greater volume of cisternal hemorrhage on an admission CT scan in patients with Fisher Grade 3 aneurysmal SAH is highly associated with DIND. A threshold of cisternal hemorrhage volume (> 20 cm3) may exist above which patients are very likely to develop DIND. Prospective application of software-based volumetric quantification of cisternal SAH may predict which patients will develop DIND.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Volumen Sanguíneo/fisiología , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/fisiopatología , Enfermedades del Sistema Nervioso/diagnóstico por imagen , Enfermedades del Sistema Nervioso/fisiopatología , Admisión del Paciente , Programas Informáticos , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Vasoespasmo Intracraneal/diagnóstico por imagen , Vasoespasmo Intracraneal/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedades del Sistema Nervioso/etiología , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Hemorragia Subaracnoidea/complicaciones , Vasoespasmo Intracraneal/etiología
18.
J Neurosurg ; 97(6): 1460-71, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12507150

RESUMEN

High-resolution dynamic infrared (DIR) imaging provides intraoperative real-time physiological, anatomical, and pathological information; however, DIR imaging has rarely been used in neurosurgical patients. The authors report on their initial experience with intraoperative DIR imaging in 30 such patients. A novel, long-wave (8-10 microm), narrow-band, focal-plane-array infrared photodetector was incorporated into a camera system with a temperature resolution of 0.006 degrees C, providing 65,000 pixels/frame at a data acquisition rate of 200 frames/second. Intraoperative imaging of patients was performed before and after surgery. Infrared data were subsequently analyzed by examining absolute differences in cortical temperatures, changes in temperature over time, and infrared intensities at varying physiological frequencies. Dynamic infrared imaging was applied in a variety of neurosurgical cases. After resection of an arteriovenous malformation, there was postoperative hyperperfusion of the surrounding brain parenchyma, which was consistent with a loss of autoregulation. Bypass patency and increased perfusion of adjacent brain were documented during two of three extracranial-intracranial bypasses. In seven of nine patients with epilepsy the results of DIR imaging corresponded to seizure foci that had been electrocorticographically mapped preoperatively. Dynamic infrared imaging demonstrated the functional cortex in four of nine patients undergoing awake resection and cortical stimulation. Finally, DIR imaging exhibited the distinct thermal footprints of 14 of 16 brain tumors. Dynamic infrared imaging may prove to be a powerful adjunctive intraoperative diagnostic tool in the neurosurgical imaging armamentarium. Real-time assessment of cerebral vessel patency and cerebral perfusion are the most direct applications of this technology. Uses of this imaging modality in the localization of epileptic foci, identification of functional cortex during awake craniotomy, and determination of tumor border and intraoperative brain shift are avenues of inquiry that require further investigation.


Asunto(s)
Neoplasias Encefálicas/cirugía , Epilepsia/cirugía , Rayos Infrarrojos , Malformaciones Arteriovenosas Intracraneales/cirugía , Monitoreo Intraoperatorio/instrumentación , Mapeo Encefálico/métodos , Neoplasias Encefálicas/diagnóstico , Corteza Cerebral/fisiología , Epilepsia/diagnóstico , Humanos , Malformaciones Arteriovenosas Intracraneales/diagnóstico , Neurocirugia/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA