Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Spine Deform ; 2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39153073

RESUMEN

PURPOSE: Adolescent idiopathic scoliosis (AIS) is a common spinal deformity with varying progression, complicating treatment decisions. Artificial intelligence (AI) and machine learning (ML) are increasingly prominent in orthopedic care, aiding in diagnosis, risk-stratification, and treatment guidance. This scoping review outlines AI applications in AIS. METHODS: This study followed PRISMA-ScR guidelines and included articles that reported the development, use, or validation of AI models for treating, diagnosing, or predicting clinical outcomes in AIS. RESULTS: 40 full-text articles were included, with most studies published in the last 5 years (77.5%). Common ML techniques were convolutional neural networks (55%), decision trees and random forests (15%), and artificial neural networks (15%). Most AI applications in AIS were for imaging analysis (25/40; 62.5%), focusing on automatic measurement of Cobb angle, and axial vertebral rotation (13/25; 52%) and curve classification/severity (13/25; 52%). Prediction was the second most common application (15/40; 37.5%), with studies predicting curve progression (9/15; 60%), and Cobb angles (9/15; 60%). Only 15 studies (37.5%) reported clinical implementation guidelines for AI in AIS management. 52.5% of studies reported model accuracy, with an average of 85.4%. CONCLUSION: This review highlights the applications of AI in AIS care, notably including automatic radiographic analysis, curve type classification, prediction of curve progression, and AIS diagnosis. However, the current lack of clear clinical implementation guidelines, model transparency, and external validation of studied models limits clinician trust and the generalizability and applicability of AI in AIS management.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38743853

RESUMEN

BACKGROUND: Instrumented spinal fusions can be used in the treatment of vertebral fractures, spinal instability, and scoliosis or kyphosis. Construct-level selection has notable implications on postoperative recovery, alignment, and mobility. This study sought to project future trends in the implementation rates and associated costs of single-level versus multilevel instrumentation procedures in US Medicare patients aged older than 65 years in the United States. METHODS: Data were acquired from the Centers for Medicare & Medicaid Services from January 1, 2000, to December 31, 2019. Procedure costs and counts were abstracted using Current Procedural Terminology codes to identify spinal level involvement. The Prophet machine learning algorithm was used, using a Bayesian Inference framework, to generate point forecasts for 2020 to 2050 and 95% forecast intervals (FIs). Sensitivity analyses were done by comparing projections from linear, log-linear, Poisson and negative-binomial, and autoregressive integrated moving average models. Costs were adjusted for inflation using the 2019 US Bureau of Labor Statistics' Consumer Price Index. RESULTS: Between 2000 and 2019, the annual spinal instrumentation volume increased by 776% (from 7,342 to 64,350 cases) for single level, by 329% (from 20,319 to 87,253 cases) for two-four levels, by 1049% (from 1,218 to 14,000 cases) for five-seven levels, and by 739% (from 193 to 1,620 cases) for eight-twelve levels (P < 0.0001). The inflation-adjusted reimbursement for single-level instrumentation procedures decreased 45.6% from $1,148.15 to $788.62 between 2000 and 2019, which is markedly lower than for other prevalent orthopaedic procedures: total shoulder arthroplasty (-23.1%), total hip arthroplasty (-39.2%), and total knee arthroplasty (-42.4%). By 2050, the number of single-level spinal instrumentation procedures performed yearly is projected to be 124,061 (95% FI, 87,027 to 142,907), with associated costs of $93,900,672 (95% FI, $80,281,788 to $108,220,932). CONCLUSIONS: The number of single-level instrumentation procedures is projected to double by 2050, while the number of two-four level procedures will double by 2040. These projections offer a measurable basis for resource allocation and procedural distribution.


Asunto(s)
Medicare , Fusión Vertebral , Humanos , Estados Unidos , Medicare/economía , Fusión Vertebral/economía , Anciano , Predicción , Femenino , Costos de la Atención en Salud , Masculino , Anciano de 80 o más Años
3.
Clin Case Rep ; 12(1): e8427, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38197064

RESUMEN

Key Clinical Message: Diffuse idiopathic skeletal hyperostosis (DISH) involves spine ligament ossification. Computer-assisted navigation (CAN) effectively aids complex surgeries, such as anterior cervical osteotomy, to alleviate progressive DISH-related dysphagia. Abstract: We describe a 68-year-old man with sudden onset dysphagia to both solids and liquids. Radiographic Imaging revealed DISH lesions from C2 down to the thoracic spine. The patient was successfully treated with CAN anterior osteotomy and resection of DISH lesions from C3-C6 and had complete symptom relief within 2 weeks post-operatively.

4.
J Robot Surg ; 17(6): 2711-2719, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37606872

RESUMEN

This study aimed to compare screw accuracy and incidence of skive between two robotically navigated instrumented techniques in posterior spine fusion surgery: manual anti-skive instrumentation with an anti-skive cannula (ASC) and the use of a navigated, high-speed drill (HSD). Over a 3-year period, consecutive patients are undergoing RNA posterior fusion surgery with either ASC (n = 53) or HSD (n = 63). Both groups met a value of approximately 292 screws in our analysis (296 ASC, 294 HSD), which was determined by a biostatistician at an academic institution. Screw accuracy and skive was analyzed using preoperative CT and intraoperative three-dimensional (3D) fluoroscopy. Among 590 planned robotically inserted pedicle screws (296 ASC, 294 HSD), 245 ASC screws (82.8%) and 283 HSD screws (96.3%) were successfully inserted (p < 0.05). Skive events occurred in 4/283 (1.4%) HSD screws and 15/245 (6.2%) ASC screws (p < 0.05). HSD screws showed better accuracy in the axial and sagittal planes, being closer to planned trajectories in all directions except cranial deviation (p < 0.05). Additionally, HSD had a significantly lower time per screw (1.9 ± 1.0 min) compared to ASC (3.2 ± 2.0 min, p < 0.001). No adverse clinical effects were observed. The HSD technique showed significant improvements in time and screw accuracy compared to ASC. Biplanar fluoroscopy and 3D imaging resulted in significantly lower radiation exposure and time compared to ASC. These significant findings in the HSD group may be attributed to the lower occurrence of malpositioned screws, leading to a decrease in the need for second authentication. This represents a notable iterative improvement of the RNA platform.


Asunto(s)
Tornillos Pediculares , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Humanos , Tornillos Pediculares/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Fluoroscopía/métodos , Cirugía Asistida por Computador/métodos , ARN
5.
Bone Joint J ; 105-B(5): 543-550, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37121590

RESUMEN

The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system. The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy. A total of 1,123 pedicle screws were implanted: 1,001 screws (89%) were placed robotically, 63 (6%) were converted from robotic placement to a freehand technique, and 59 (5%) were planned to be implanted freehand. Of the robotically placed screws, 942 screws (94%) were determined to be Gertzbein and Robbins grade A with median deviation of 0.8 mm (interquartile range 0.4 to 1.6). Skive events were noted with 20 pedicle screws (1.8%). No adverse clinical sequelae were noted in the 90-day follow-up. The mean fluoroscopic exposure per screw was 4.9 seconds (SD 3.8). RNA is highly accurate and reliable, with a low rate of abandonment once mastered. No adverse clinical sequelae occurred after implanting a large series of pedicle screws using the latest generation of RNA. Understanding of patient-specific anatomical features and the real-time intraoperative identification of risk factors for suboptimal screw placement have the potential to improve accuracy further.


Asunto(s)
Tornillos Pediculares , Procedimientos Quirúrgicos Robotizados , Robótica , Fusión Vertebral , Cirugía Asistida por Computador , Adulto , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Columna Vertebral/cirugía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Cirugía Asistida por Computador/métodos , Fusión Vertebral/métodos , ARN
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...