Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38553310

RESUMEN

OBJECTIVE: This study aimed to assess the performance of a convolutional neural network (CNN) model in detecting the pubertal growth spurt by analyzing cervical vertebrae maturation (CVM) in lateral cephalometric radiographs (LCRs). STUDY DESIGN: In total, 600 LCRs of patients from 6 to 17 years old were selected. Three radiologists independently and blindly classified the maturation stages of the LCRs and defined the difficulty of each classification. Subsequently, the stage and level of difficulty were determined by consensus. LCRs were distributed between training, validation, and test datasets across 4 CNN-based models. The models' responses were compared with the radiologists' reference standard, and the architecture with the highest success rate was selected for evaluation. Models were developed using full and cropped LCRs with original and simplified maturation classifications. RESULTS: In the simplified classification, the Inception-v3 CNN yielded an accuracy of 74% and 75%, with recall and precision values of 61% and 62%, for full and cropped LCRs, respectively. It achieved 61% and 62% total success rates with full and cropped LCRs, respectively, reaching 72.7% for easy-to-classify cropped cases. CONCLUSION: Overall, the CNN model demonstrated potential for determining the maturation status regarding the pubertal growth spurt through images of the cervical vertebrae. It may be useful as an initial assessment tool or as an aid for optimizing the assessment and treatment decisions of the clinician.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38530071

RESUMEN

This review analyzes the occurrence and co-exposure of aflatoxins and fumonisins in conventional and organic corn, and compares the vulnerability to contamination of both. The risks of fungal contamination in corn are real, mainly by the genera Aspergillus and Fusarium, producers of aflatoxins and fumonisins, respectively. Aflatoxins, especially AFB1, are related to a high incidence of liver cancer, and the International Agency Research of Cancer (IARC) classified them in group 1A 'carcinogenic to humans'. The occurrence in conventional corn is reported in many countries, including at higher levels than those established by legislation. IARC classified fumonisins in group 2B 'possibly carcinogenic to humans' due to their link with incidence of esophageal cancer. However, comparing corn and organic and conventional by-products from different regions, different results are observed. The co-occurrence of both mycotoxins is a worldwide problem; nevertheless, there is little data on the comparison of the co-exposure of these mycotoxins in corn and derivatives between both systems. It was found that the agricultural system is not a decisive factor in the final contamination, indicating the necessity of effective strategies to reduce contamination and co-exposure at levels that do not pose health risks.


Asunto(s)
Aflatoxinas , Contaminación de Alimentos , Fumonisinas , Zea mays , Zea mays/química , Fumonisinas/análisis , Aflatoxinas/análisis , Contaminación de Alimentos/análisis , Humanos , Aspergillus , Fusarium
3.
Pharmaceuticals (Basel) ; 17(2)2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38399430

RESUMEN

The remission of obesity-related diseases following bariatric surgery appears to result from the reorganization of metabolic and hormonal pathways involving adipokines. This study aimed to investigate the relationship between changes in body adiposity and serum adipokine levels, as well as the association between variations in adiponectin or resistin levels and cardiometabolic risk blood biomarkers before and after Roux-en-Y gastric bypass. A longitudinal and prospective study was conducted with bariatric surgery patients. Anthropometric, body composition and blood biochemical parameters were measured before and at 2 and 6 months post-surgery. The data were analyzed using ANOVA, Pearson or Spearman correlation, and simple linear regression with a significance level of p < 0.05. Among 36 mostly female patients aged 30 to 39 years, significant reductions in body weight (-26.8%), fat mass (-50%), waist circumference (-18%) and waist-to-height ratio (-22%) were observed post-surgery. Serum adiponectin levels increased (+107%), while resistin (-12.2%), TNF-α (-35%), and PAI-1 (-11.1%) decreased. Glucose, insulin, CRP, cholesterol, LDL-c, triglycerides, and vitamin D also decreased. Waist circumference variation showed a positive correlation with PAI-1 and TNF-α and a negative correlation with adiponectin. The total fat mass showed a positive correlation with PAI-1. Adiponectin variation correlated negatively with glucose, resistin, and CRP but positively with HDL-c. Resistin showed a positive correlation with insulin and CRP. In conclusion, 6 months post-bariatric surgery, reducing abdominal adiposity had a more significant impact on serum adipokine levels than total fat mass. Adiponectin increase and resistin decrease acted as endocrine mediators driving the remission of cardiometabolic risk biomarkers in individuals with obesity following Roux-en-Y gastric bypass.

4.
Odontology ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38214844

RESUMEN

This study aimed to evaluate the influence of the metal post composition, tooth location in the dental arch, and metal artifact reduction (MAR) on vertical root fracture (VRF) diagnosis in cone beam computed tomography (CBCT). Twenty-two unirradicular premolars (12 sound and 10 fractured) and two alveolar sockets of a mandible (anterior and posterior regions) composed the sample. CBCT scans of each tooth with a metal post placed into the root canal-silver-palladium (Ag-Pd), cobalt-chromium (Co-Cr), or nickel-chromium (Ni-Cr)-were individually acquired for each mandibular region, and two conditions of MAR, using a OP300 device (Instrumentarium, Finland). Images were assessed by five evaluators independently for VRF detection. Diagnostic values were calculated and compared among all groups using multi-way ANOVA with Tukey post hoc test to investigate the effect of post material, anatomical region, and MAR on VRF diagnosis (α = 0.05). Values of area under the receiver operating curve and specificity were not influenced by the studied factors (p > 0.05). Sensitivity was influenced by the MAR in both mandibular regions (p < 0.05). In the anterior region, sensitivity values increased when the MAR was enabled, regardless of the metal post material (p < 0.05). Similar behavior was noticed in the posterior region for Ni-Cr (p < 0.05) but not for Ag-Pd and Co-Cr posts (p > 0.05). The MAR improved the sensitivity in VRF diagnosis for all tested metal posts in the mandibular anterior region and for the Ni-Cr post in the mandibular posterior region. Therefore, for images obtained in the OP300 CBCT device, activation of the MAR is suggested in these cases.

5.
Artículo en Inglés | MEDLINE | ID: mdl-37940483

RESUMEN

OBJECTIVE: We evaluated the influence of an adjacent zirconium implant, tube current (mA), and a metal artifact reduction algorithm (MARA) on horizontal root fracture (HRF) diagnosis in cone beam computed tomography (CBCT). STUDY DESIGN: Nineteen teeth (9 with HRF, 10 without) were individually placed in a human maxilla. Scan volumes were acquired without and with a zirconium implant adjacent to the tooth at settings of 4, 8, and 10 mA, with MARA disabled and enabled, using a 5×5 cm field of view, 0.085-mm voxel size, and 90 kV. Four maxillofacial radiologists individually assessed the scans. Diagnostic metrics were compared by multiway analysis of variance (α=5%). Inter- and intraexaminer agreements for HRF diagnosis were evaluated with the weighted kappa test. RESULTS: Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were significantly lower in the presence of the implant (P≤.005). AUC values were higher in scans obtained with 8 and 10 mA compared with 4 mA (P=0.010), but 10 mA without MARA was better with the implant present. MARA did not significantly influence outcomes (P≥0.240). Inter- and intraexaminer agreements ranged from moderate to almost perfect. CONCLUSIONS: The presence of the zirconium implant impairs HRF detection. Settings of 8 or 10 mA improve HRF detection regardless MARA condition without the implant. With an adjacent implant, 10 mA without MARA is recommended to improve diagnostic performance.


Asunto(s)
Fracturas de los Dientes , Raíz del Diente , Humanos , Raíz del Diente/diagnóstico por imagen , Circonio , Fracturas de los Dientes/diagnóstico por imagen , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Algoritmos
6.
Artículo en Inglés | MEDLINE | ID: mdl-37838553

RESUMEN

OBJECTIVE: We evaluated artifact expression in a root adjacent to a dental implant located in the endomass or exomass in cone beam computed tomography (CBCT). STUDY DESIGN: We placed a single titanium or zirconia implant adjacent to a premolar root in a dried human mandible and acquired CBCT scans using an OP300 Maxio and a Picasso Trio 3D unit exposing a 5x5cm field of view with the implant in the endomass or exomass (implant groups) or without an implant (control group). We measured the mean gray values (MGVs) for 8 lines of interest (LOIs) around the root canal of the premolar and compared the MGVs by analysis of variance, with significance established at P < 0.05. RESULTS: For the OP300 Maxio scans, the MGVs of both implant groups in the endomass were lower than the MGVs of the control group. In the exomass, the titanium group had MGVs similar to the control group, but the zirconia group produced significantly lower MGVs than control and titanium groups (P <.0001), indicating the presence of hypodense artifacts. For the Picasso Trio 3D scans, the MGVs of both implant groups in the endomass were similar to the MGVs of the control group. In the exomass, the zirconia group generated lower MGVs than control and titanium groups (P <.0001), indicating hypodense artifacts. CONCLUSIONS: When performing CBCT examination, titanium implants produce less artifact expression in the exomass, and zirconia implants have less artifact expression in the endomass.


Asunto(s)
Implantes Dentales , Titanio , Humanos , Artefactos , Circonio , Tomografía Computarizada de Haz Cónico/métodos
7.
Braz Dent J ; 34(4): 150-157, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909638

RESUMEN

This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Asunto(s)
Radiografía Dental Digital , Radiografía Dental Digital/métodos
8.
Mar Pollut Bull ; 197: 115717, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37924737

RESUMEN

The presence of marine litter in the deep ocean (>200 m depth) may represent an invisible threat that has been neglected due to the scarcity of data. Herein, we provide the first report of persistent marine litter on the Southwestern Atlantic continental slope. Marine litter was collected onboard the Brazilian R/V Alpha Crucis, using bottom trawling, in 28 out of 31 sampled stations, between 274 and 1520 m depth, in two distinct areas off the southern Brazilian coast. In total, 603 items and 13.8 kg of litter were collected and classified according to the type of material. Plastic was the most frequent and most abundant material found. Although there was no bathymetric variation along the slope, density of litter was considerably higher off São Paulo than off Santa Catarina State, supposedly due to the heavier presence of oil and gas platforms and large cargo vessels.


Asunto(s)
Monitoreo del Ambiente , Plásticos , Brasil , Residuos/análisis
9.
Pharmaceuticals (Basel) ; 16(10)2023 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-37895845

RESUMEN

The objective of this study is to assess the effectiveness of treatment for inflammatory bowel diseases in modulating oxidative stress biomarkers and cytokine levels. A systematic review of clinical trials was conducted, searching electronic databases including PubMed, Science Direct, and Scopus. After excluding articles that did not meet the inclusion criteria, 19 studies were included in the systematic review and 8 in the meta-analysis (6 for antioxidant capacity, 6 for superoxide dismutase (SOD), and 5 for lipid peroxidation analyzed through malondialdehyde (MDA) levels). SOD was significantly modulated (RR = 0.3764, 95% CI [0.0262 to 0.7267], p = 0.035) but not antioxidant capacity (RR = 0.3424, 95% CI [0.0334 to 0.7183], p = 0.0742) or MDA (RR = -0.8534, 95% CI [-1.9333 to 0.2265], p = 0.1214). Nonetheless, studies investigating oxidative stress biomarkers and cytokines in the context of alternative therapies for IBD treatment are still scarce. This review highlights the potential of antioxidant supplementation in IBD management and underscores the need for further investigations into its effects on oxidative stress biomarkers and cytokines to improve therapeutic approaches for IBD patients.

10.
Clin Oral Investig ; 27(11): 6451-6460, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37728617

RESUMEN

OBJECTIVES: To compare the multilayer panoramic radiography (MPAN) and conventional panoramic radiography (CPAN) in the evaluation of mandibular third molars using cone-beam computed tomography (CBCT) as a reference. METHODS: CPAN, MPAN, and CBCT scans from 33 dry human mandibles were acquired using the OP300 Maxio unit, totalizing 56 mandibular third molars to be evaluated. Three examiners evaluated each third molar according to their position, depth of impaction in the mandibular ramus, proximity between the dental root apexes and the mandibular canal, and the presence of radiographic signs of proximity to the mandibular canal. In addition, when there was a distance between the root apexes and the mandibular canal, it was measured. As a reference, these same parameters were assessed in the CBCT scans by a fourth examiner. For the statistical analysis, the weighted Kappa, Bland Altman, and Wilcoxon tests were performed (α = 0.05). RESULTS: The agreement between the assessments performed in the panoramic modalities with the CBCT ranged from 66.1% to 100.0% for the categorical variables. Overall, the agreement values of CPAN and MPAN with CBCT were similar. The distances between the dental root apex and the mandibular canal for both CPAN and MPAN were significantly underestimated compared to CBCT (p < 0.05). The intra- and interexaminer agreements of the examiners ranged from poor to almost perfect; in general, the agreements were higher in the evaluation performed in the MPAN than in the CPAN. CONCLUSIONS: The MPAN performs similarly to CPAN for evaluating mandibular third molars and their proximity relationship to the mandibular canal. CLINICAL RELEVANCE: Preoperative evaluation of lower mandibular third molars is usually performed using CPAN. Recently, a new tool, MPAN, was developed, which has not yet been tested for the evaluation of mandibular third molars and showed similar performance to CPAN in the present study. Future studies using MPAN are encouraged to evaluate other diagnostic tasks.


Asunto(s)
Tercer Molar , Diente Impactado , Humanos , Tercer Molar/cirugía , Radiografía Panorámica/métodos , Diente Molar , Mandíbula , Tomografía Computarizada de Haz Cónico/métodos
11.
Oxid Med Cell Longev ; 2023: 8811463, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37577725

RESUMEN

Ulcerative colitis (UC) is a chronic and recurrent inflammatory bowel disease (IBD) characterized by continuous inflammation in the colonic mucosa. Extraintestinal manifestations (EIM) occur due to the disruption of the intestinal barrier and increased permeability caused by redox imbalance, dysbiosis, and inflammation originating from the intestine and contribute to morbidity and mortality. The aim of this study is to investigate the effects of oral N-acetylcysteine (NAC) on colonic, hepatic, and renal tissues in mice with colitis induced by dextran sulfate sodium (DSS). Male Swiss mice received NAC (150 mg/kg/day) in the drinking water for 30 days before and during (DSS 5% v/v; for 7 days) colitis induction. On the 38th day, colon, liver, and kidney were collected and adequately prepared for the analysis of oxidative stress (superoxide dismutase (SOD), catalase (CAT), glutathione reduced (GSH), glutathione oxidized (GSSG), malondialdehyde (MDA), and hydrogen peroxide (H2O2)) and inflammatory biomarkers (myeloperoxidase (MPO) -, tumor necrosis factor alpha - (TNF-α, and interleukin-10 (IL-10)). In colon, NAC protected the histological architecture. However, NAC did not level up SOD, in contrast, it increased MDA and pro-inflammatory effect (increased of TNF-α and decreased of IL-10). In liver, colitis caused both oxidative (MDA, SOD, and GSH) and inflammatory damage (IL-10). NAC was able only to increase GSH and GSH/GSSG ratio. Kidney was not affected by colitis; however, NAC despite increasing CAT, GSH, and GSH/GSSG ratio promoted lipid peroxidation (increased MDA) and pro-inflammatory action (decreased IL-10). Despite some beneficial antioxidant effects of NAC, the negative outcomes concerning irreversible oxidative and inflammatory damage in the colon, liver, and kidney confirm the nonsafety of the prophylactic use of this antioxidant in models of induced colitis, suggesting that additional studies are needed, and its use in humans not yet recommended for the therapeutic routine of this disease.


Asunto(s)
Colitis Ulcerosa , Colitis , Humanos , Masculino , Ratones , Animales , Acetilcisteína/farmacología , Acetilcisteína/uso terapéutico , Acetilcisteína/metabolismo , Interleucina-10/metabolismo , Factor de Necrosis Tumoral alfa/metabolismo , Peróxido de Hidrógeno/farmacología , Disulfuro de Glutatión/metabolismo , Colitis/inducido químicamente , Colitis/complicaciones , Colitis/tratamiento farmacológico , Colon , Colitis Ulcerosa/inducido químicamente , Colitis Ulcerosa/tratamiento farmacológico , Colitis Ulcerosa/patología , Antioxidantes/farmacología , Inflamación/patología , Estrés Oxidativo , Hígado/metabolismo , Glutatión/metabolismo , Superóxido Dismutasa/metabolismo , Sulfato de Dextran/toxicidad
12.
Braz. dent. j ; 34(4): 150-157, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1520332

RESUMEN

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

13.
Artículo en Inglés | MEDLINE | ID: mdl-37468380

RESUMEN

OBJECTIVE: This study evaluated changes in image quality and the presence and size of artifacts on radiographs obtained with photostimulable phosphor (PSP) plates after disinfection with 70% ethyl alcohol and 70% isopropyl alcohol. STUDY DESIGN: Eight PSP receptors (4 Express and 4 VistaScan) were used for the investigation. Two Express and 2 VistaScan receptors were disinfected with 70% ethyl alcohol, and 2 Express and 2 VistaScan receptors were disinfected with 70% isopropyl alcohol. Before disinfection and after every 5 disinfections, 2 radiographs of an aluminum stepwedge and 2 radiographs of an acrylic block were acquired using each receptor. The gray values of the radiographs were analyzed regarding contrast, density, uniformity, and noise. Four oral radiologists evaluated the images for the presence of artifacts, and 2 measured the artifacts. RESULTS: Differences in image contrast were significantly larger with isopropyl alcohol (P < .0001). Artifact size was significantly greater with the VistaScan system when isopropyl alcohol was used as the disinfectant (P < .0001). The correlation between the number of disinfections and artifact size was moderately positive with the Express system (P < .05) and strongly positive with the VistaScan system (P < .05) with both disinfectants. CONCLUSIONS: Small artifacts restricted to the edges of the image were observed with disinfection using both types of alcohol, and a positive correlation was found between artifact size and the number of disinfections. However, artifacts appeared earlier and of greater size with the VistaScan system when disinfected with 70% isopropyl alcohol. Thus, we recommend using 70% ethyl alcohol to disinfect PSP receptors, with attention placed on its action and evaporation times.


Asunto(s)
2-Propanol , Radiografía Dental Digital , Humanos , Radiografía Dental Digital/métodos , Desinfección/métodos , Artefactos , Intensificación de Imagen Radiográfica/métodos , Etanol
14.
PLoS One ; 18(6): e0286853, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37294785

RESUMEN

Oral and maxillofacial surgeons are among the frontline healthcare workers and are classified as a high-risk group for COVID-19 infection; however, it has not yet been defined how these professionals were impacted. The aim of this study was to explore the conducts and perceptions of oral and maxillofacial surgeons during the COVID-19 pandemic in Brazil. Nine individuals, mean age 34.8 years, 66.6% men, were included in the study. A semi-structured interview with a qualitative approach was applied to professionals belonging to a messaging application group (WhatsApp). Content analysis was performed in the light of Hellerian theory in its daily theoretical framework for the interpretation of the memories reported by the participants. Four themes were identified. The lack of knowledge about COVID-19 and the fear of being contaminated during care were the main factors responsible for changes in the professionals' work routine. An important point was the collective reflection of the participants about the increase in biosafety barriers, which ensured a greater sense of security. The need for social isolation to contain the virus was also described. As a result, there was a great distance between professionals and their families, which generated high levels of anxiety in the former. Repetitive reports of slowness and reduced attendance directly related to financial loss and aggravated stress were also highlighted. The findings of this study reveal that oral and maxillofacial surgeons had their professional-personal axis affected in terms of daily habits, family life and financial strain, aspects that were responsible for impacting stress and anxiety levels.


Asunto(s)
COVID-19 , Masculino , Humanos , Adulto , Femenino , COVID-19/epidemiología , Pandemias , Cirujanos Oromaxilofaciales , Personal de Salud , Ansiedad/epidemiología , Investigación Cualitativa
15.
RECIIS (Online) ; 17(2)abr.-jun.,2023. 387^c407
Artículo en Portugués | LILACS | ID: biblio-1438495

RESUMEN

Estudo exploratório realizado entre 14/02/2021 e 06/03/2021, visando mapear e caracterizar os perfis sobre traumatismos dentários no Instagram, analisar as publicações quanto ao teor e à qualidade do conteúdo, como também examinar a interação e a prática comunicativa. Foram incluídos 25 perfis que apresentavam baixa audiência e pequena atividade, considerando-se o número de seguidores, a frequência de atualização e o número de publicações. Dezoito perfis eram brasileiros e estavam vinculados a projetos de extensão de Instituições de Ensino Superior (IES). Realizou-se a análise de 13 posts dos três perfis ativos, e verificou-se que eles estavam em conformidade com os protocolos da Associação Internacional de Traumatologia Dentária. As práticas comunicativas eram informacionais não se configurando como espaços de aprendizagem colaborativa. Redes sociais on-line constituem-se atualmente em estratégias importantes para a divulgação científica e a participação cidadã, mas os limites e os desafios do seu uso devem ser levados em conta no planejamento das ações de comunicação institucional em saúde pública


Exploratory study made from 14/02/2021 to 06/03/2021, aiming to map and characterize the profiles about dental trauma on Instagram, besides analyzing the posts according to its content and quality, interac-tions and communicative practice. Twenty-five profiles were included and presented low audience and low activity, considering the number of followers, updating frequency and number of posts. Eighteen of these profiles were Brazilian and had links with Universities Extension Projects. Thirteen posts were analyzed on the three active profiles, and it was verified that they were in conformity to the International Association of Dental Traumatology (IADT). The communicative practices were international, not being configured as collaborative learning spaces. Social media are important strategies to scientific communication and citizen participation, but limits and challenges of its use must be considered on the planning of institutional public health communication


Estudio exploratorio realizado entre el 14/02/2021 y el 06/03/2021, con el objetivo de mapear y caracteri-zar perfiles sobre trauma dental en Instagram, además de analizar publicaciones sobre contenido y calidad del contenido, interaciones y la práctica comunicativa. Se incluyeron 25 perfiles que tenían baja audiencia y poca actividad, considerando el número de seguidores, frecuencia de actualización y número de publica-ciones. Dieciocho perfiles eran brasileños y estaban vinculados a proyectos de extensión de Instituciones de Educación Superior. Se realizó un análisis de 13 publicaciones de los tres perfiles activos y se verificó que cumplían con los protocolos de la Asociación Internacional de Traumatología Dental. Las prácticas comunicativas fueron informacionales, no configuradas como espacios de aprendizaje colaborativo. Las redes sociales constituyen estrategias importantes para la divulgación científica y la participación ciuda-dana, pero los límites y desafíos de su uso deben ser tomados en cuenta a la hora de planificar acciones de comunicación institucional en salud pública


Asunto(s)
Humanos , Odontología , Red Social , COVID-19 , Comunicación , Comunicación y Divulgación Científica , Comunicación en Salud
16.
Rev. Inst. Adolfo Lutz (Online) ; 82: 39330, maio 2023. tab
Artículo en Portugués | LILACS, CONASS, ColecionaSUS, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: biblio-1524978

RESUMEN

A hiperpigmentação da pele, principalmente na região facial, resulta em um incômodo estético que afeta a qualidade de vida do indivíduo, levando a busca por produtos clareadores. Este estudo avaliou a conformidade dos rótulos de cosméticos comercializados como "produtos clareadores de pele", bem como a existência de substâncias clareadoras proibidas neste tipo de produto. Foi realizada uma análise transversal descritiva qualitativa no período de abril a maio de 2022, em busca por cosméticos comercializados em estabelecimentos farmacêuticos e lojas de produtos cosméticos localizadas no município de Juazeiro/BA. Foram selecionados 18 produtos e os desvios de rotulagem identificados com base na legislação utilizada vigente à época do estudo, foram: ausência de informações sobre advertências/restrições de uso e número de registro incompleto, equivalente a 16,7% (n = 3) das amostras. A hidroquinona, proibida nesse tipo de produto, foi encontrada em um cosmético (5,5%). Embora a maioria das amostras analisadas esteja em conformidade com as exigências legais, os resultados evidenciam descumprimentos, indicando a necessidade de uma fiscalização mais rigorosa a fim de evitar possíveis danos à saúde do usuário. (AU)


Skin hyperpigmentation, particularly in the facial region, can be an aesthetic nuisance that affects an individual's quality of life, leading them to seek out whitening products. This study evaluated the compliance of cosmetics labels marketed as "skin lightening products", and assessed the presence of whitening substances prohibited in this type of product. A qualitative, descriptive, cross-sectional analysis was conducted between April and May 2022 in Juazeiro, Bahia, Brazil, focusing on cosmetics sold in pharmaceutical establishments and cosmetic product stores. Eighteen products were selected, and labeling deviations identified based on the legislation in force at the time of the study. These included a lack of information on warnings/use restrictions and incomplete registration numbers, affecting 16.7% (n = 3) of the samples. Hydroquinone, prohibited in this type of product by the legislation, was detected in one cosmetic (5.5%). Although most of the analyzed samples comply with legal requirements, the observed non-compliance highlights the need for more stringent inspection to prevent potential harm to user's health. (AU)


Asunto(s)
Brasil , Hiperpigmentación , Etiquetado de Cosméticos , Preparaciones para Aclaramiento de la Piel
17.
Rev. Inst. Adolfo Lutz (Online) ; 82: e39330, maio 2023. tab
Artículo en Portugués | LILACS, VETINDEX, SES-SP | ID: biblio-1524321

RESUMEN

A hiperpigmentação da pele, principalmente na região facial, resulta em um incômodo estético que afeta a qualidade de vida do indivíduo, levando a busca por produtos clareadores. Este estudo avaliou a conformidade dos rótulos de cosméticos comercializados como "produtos clareadores de pele", bem como a existência de substâncias clareadoras proibidas neste tipo de produto. Foi realizada uma análise transversal descritiva qualitativa no período de abril a maio de 2022, em busca por cosméticos comercializados em estabelecimentos farmacêuticos e lojas de produtos cosméticos localizadas no município de Juazeiro/BA. Foram selecionados 18 produtos e os desvios de rotulagem identificados com base na legislação utilizada vigente à época do estudo, foram: ausência de informações sobre advertências/restrições de uso e número de registro incompleto, equivalente a 16,7% (n = 3) das amostras. A hidroquinona, proibida nesse tipo de produto, foi encontrada em um cosmético (5,5%). Embora a maioria das amostras analisadas esteja em conformidade com as exigências legais, os resultados evidenciam descumprimentos, indicando a necessidade de uma fiscalização mais rigorosa a fim de evitar possíveis danos à saúde do usuário.


Skin hyperpigmentation, particularly in the facial region, can be an aesthetic nuisance that affects an individual's quality of life, leading them to seek out whitening products. This study evaluated the compliance of cosmetics labels marketed as "skin lightening products", and assessed the presence of whitening substances prohibited in this type of product. A qualitative, descriptive, cross-sectional analysis was conducted between April and May 2022 in Juazeiro, Bahia, Brazil, focusing on cosmetics sold in pharmaceutical establishments and cosmetic product stores. Eighteen products were selected, and labeling deviations identified based on the legislation in force at the time of the study. These included a lack of information on warnings/use restrictions and incomplete registration numbers, affecting 16.7% (n = 3) of the samples. Hydroquinone, prohibited in this type of product by the legislation, was detected in one cosmetic (5.5%). Although most of the analyzed samples comply with legal requirements, the observed non-compliance highlights the need for more stringent inspection to prevent potential harm to user's health.


Asunto(s)
Hiperpigmentación/terapia , Etiquetado de Cosméticos , Preparaciones para Aclaramiento de la Piel/análisis , Hidroquinonas/toxicidad , Brasil
18.
Sci Rep ; 13(1): 6266, 2023 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-37069172

RESUMEN

Photon-counting computed tomography (PCCT) is an innovative technological advancement in relation to x-ray detectors which offers ultra-high-resolution images. The current study aimed to evaluate the visualization ability of PCCT compared to cone-beam computed tomographic (CBCT) devices for challenging endodontic diagnostic tasks. A reference image of an anthropomorphic phantom was acquired using an industrial micro-CT device. Thereafter, the phantom was scanned with three imaging devices, which included PCCT scanner (NAEOTOM Alpha) and two CBCT devices (3D Accuitomo 170 and NewTom VGi evo) having standard and high-resolution acquisition protocols. The diagnostic tasks involved visualizing fine endodontic structures (apical delta, narrow canal, and isthmus) and root cracks. Three experienced examiners assessed the images and were blinded to the PCCT and CBCT devices. Each image was rated according to a three-grade scale (appropriate, acceptable, or inappropriate) for the diagnostic tasks. In relation to fine endodontic structures grouped together, PCCT showed similar diagnostic performance compared to the reference image (p > 0.05). As for the CBCT devices, an excellent performance was only observed with the 3D Accuitomo 170 device at a high-resolution acquisition mode (p > 0.05). The visualization of root cracks was also better with 3D Accuitomo 170 compared to other devices (p < 0.05). Overall, PCCT and 3D Accuitomo 170 at a high-resolution setting showed similar performance for visualizing fine endodontic structures. In addition, the high-resolution CBCT protocol was superior for visualizing root cracks compared to both PCCT and other standard- and high-resolution CBCT protocols.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada de Haz Cónico/métodos , Estudios de Factibilidad , Microtomografía por Rayos X , Fantasmas de Imagen
19.
Braz Dent J ; 34(1): 39-44, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36888843

RESUMEN

The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Asunto(s)
Radiografía Dental Digital , Radiografía Dental Digital/métodos , Reproducibilidad de los Resultados
20.
J Appl Oral Sci ; 31: e20220374, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36753087

RESUMEN

This systematic review and meta-analysis aimed to analyze the impact of the COVID-19 pandemic on dental trauma patient attendance. The study was registered in the PROSPERO system, using the CRD42021288398 protocol. Searching was performed in PubMed, Scopus, Web of Science, Embase, Lilacs, and OpenGrey databases, using the following keywords: "Tooth injuries," "Dental trauma," "Traumatic Dental injury," and "COVID-19". We included observational studies evaluating dental trauma in the context of the COVID-19 pandemic. Quality assessment was performed using the Joanna Briggs Institute Critical Appraisal Checklist for Cross-Sectional Studies. Meta-analysis was performed in RevMan 5.4 software with Odds Ratios as a pooled measure of effect, with a 95% confidence interval, and using random-effects modeling. After applying the eligibility criteria, 32 studies were included for qualitative analysis, in which 10 were used to assess the frequency of dental trauma diagnoses in dental emergencies. Despite the decrease of visits during COVID-19, the analysis revealed no difference between the pandemic and pre-pandemic periods. Regarding the type of dental trauma, two of the studies revealed no differences for the periods before and during the pandemic. This study revealed that the COVID-19 pandemic has not impacted the frequency or type of dental trauma compared to previous periods.


Asunto(s)
COVID-19 , Traumatismos de los Dientes , Humanos , COVID-19/epidemiología , Pandemias , Estudios Transversales , Traumatismos de los Dientes/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA