Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Front Immunol ; 15: 1368399, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38596685

RESUMEN

Introduction: The complement external quality assurance (EQA) program was first organized in 2010 by a group of researchers working in diagnostic complement laboratories. Starting in 2016, INSTAND e.V., a German, non-profit interdisciplinary scientific medical society dedicated to providing expert EQA programs for medical laboratories, started organizing the EQAs for complement diagnostic laboratories together with the same group of experienced scientists and doctors who also work as EQA experts. The aim of the current work is to provide descriptive analysis of the past seven years' complement EQA results and evaluate timeline changes in proficiency testing. Methods: Each year, in March and October, blinded samples (normal, pathological) were sent to the participating diagnostic laboratories, where complement parameters were evaluated exactly as in daily routine samples. Since no reference method/target values exist for these parameters, and participants used different units for measurement, the reported results were compared to the stable mean (Algorithm A) of the participants using the same method/measurement units. A reported result was qualified as "passed" if it fell into the 30-50% evaluation/target range around the mean of reported results (depending on the given parameter). Results: While the number of participating laboratories has increased in the past years (from around 120 to 347), the number of complement laboratories providing multiple determinations remained mostly unchanged (around 30 worldwide). C3, C4, C1-inhibitor antigen and activity determinations provided the best proficiency results, with >90% passing quotas in the past years, independent of the applied method. Determination of the functional activity of the three activation pathways was good in general, but results showed large variance, especially with the pathological samples. Complement factor C1q and regulators FH and FI are determined by only a few laboratories, with variable outcomes (in general in the 85-90% pass range). Activation products sC5b-9 and Bb were determined in 30 and 10 laboratories, respectively, with typical passing quotas in the 70-90% range, without a clear tendency over the past years. Conclusion: With these accumulated data from the past seven years, it is now possible to assess sample-, method-, and evaluation related aspects to further improve proficiency testing and protocolize diagnostic complement determinations.


Asunto(s)
Laboratorios , Humanos
2.
Sci Rep ; 13(1): 13206, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37580353

RESUMEN

The COVID-19 pandemic illustrated the important role of diagnostic tests, including lateral flow tests (LFTs), in identifying patients and their contacts to slow the spread of infections. INSTAND performed external quality assessments (EQA) for SARS-CoV-2 antigen detection with lyophilized and chemically inactivated cell culture supernatant of SARS-CoV-2 infected Vero cells. A pre-study demonstrated the suitability of the material. Participants reported qualitative and/or quantitative antigen results using either LFTs or automated immunoassays for five EQA samples per survey. 711 data sets were reported for LFT detection in three surveys in 2021. This evaluation focused on the analytical sensitivity of different LFTs and automated immunoassays. The inter-laboratory results showed at least 94% correct results for non-variant of concern (VOC) SARS-CoV-2 antigen detection for viral loads of ≥ 4.75 × 106 copies/mL and SARS-CoV-2 negative samples. Up to 85% had success for a non-VOC viral load of ~ 1.60 × 106 copies/mL. A viral load of ~ 1.42 × 107 copies/mL of the Delta VOC was reported positive in > 96% of results. A high specificity was found with almost 100% negative SARS-CoV-2 antigen results for HCoV 229E and HCoV NL63 positive samples. Quantitative results correlated with increasing SARS-CoV-2 viral load but showed a broad scatter. This study shows promising SARS-CoV-2 antigen test performance of the participating laboratories, but further investigations with the now predominant Omicron VOC are needed.


Asunto(s)
COVID-19 , SARS-CoV-2 , Chlorocebus aethiops , Animales , Humanos , Pandemias , Células Vero , COVID-19/diagnóstico , COVID-19/epidemiología , Pruebas Inmunológicas , Sensibilidad y Especificidad
3.
PLoS One ; 18(4): e0285203, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37115793

RESUMEN

BACKGROUND: In May 2022, the monkeypox virus (MPXV) spread into non-endemic countries and the global community was quick to test the lessons learned from the SARS-CoV-2 pandemic. Due to its symptomatic resemblance to other diseases, like the non-pox virus varicella zoster (chickenpox), polymerase chain reaction methods play an important role in correctly diagnosing the rash-causing pathogen. INSTAND quickly established a new external quality assessment (EQA) scheme for MPXV and orthopoxvirus (OPXV) DNA detection to assess the current performance quality of the laboratory tests. METHODS: We analyzed quantitative and qualitative data of the first German EQA for MPXV and OPXV DNA detection. The survey included one negative and three MPXV-positive samples with different MPX viral loads. The threshold cycle (Ct) or other measures defining the quantification cycle (Cq) were analyzed in an assay-specific manner. A Passing Bablok fit was used to investigate the performance at laboratory level. RESULTS: 141 qualitative datasets were reported by 131 laboratories for MPXV detection and 68 qualitative datasets by 65 laboratories for OPXV detection. More than 96% of the results were correctly identified as negative and more than 97% correctly identified as positive. An analysis of the reported Ct/Cq values showed a large spread of these values of up to 12 Ct/Cq. Nevertheless, there is a good correlation of results for the different MPXV concentrations at laboratory level. Only a few quantitative results in copies/mL were reported (MPXV: N = 5; OPXV: N = 2), but the results correlated well with the concentration differences between the EQA samples, which were to a power of ten each. CONCLUSION: The EQA results show that laboratories performed well in detecting both MPXV and OPXV. However, Ct/Cq values should be interpreted with caution when conclusions are drawn about the viral load as long as metrological traceability is not granted.


Asunto(s)
COVID-19 , Mpox , Orthopoxvirus , Humanos , Monkeypox virus/genética , SARS-CoV-2/genética
4.
Ann Allergy Asthma Immunol ; 121(4): 490-495, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30025909

RESUMEN

BACKGROUND: Even though allergies are an important health issue, the detected amount of allergen-specific IgE (sIgE) has differed widely between manufacturers in the past, and even as recently as this year. These discrepancies hinder diagnostics and can even impact allergen immunotherapy. OBJECTIVE: The aim of this study was to evaluate the development and status quo of the quality of in vitro diagnostic testing for house dust mites (HDM) and cat epithelium, 2 important indoor allergen sources. METHODS: We analyzed data on the allergen sources European HDM, American HDM, and cat epithelium, which were collected by the Society for Promoting Quality Assurance in Medical Laboratories (INSTAND e.V.) during 7 years as part of External Quality Assessment schemes (EQAs). A pseudoanonymized comparison was made of the semiquantitative data and allergen-class results of the 4 main suppliers of in vitro diagnostic sIgE tests. Coefficients of variation (CV) were determined in order to evaluate interlaboratory comparability. RESULTS: In vitro allergy diagnostic testing for the major allergen sources HDM and cat epithelium still reveals manufacturer-dependent differences. Despite this, a cautious trend was found towards an alignment of the results and interlaboratory comparability, with the exception of 1 supplier. CONCLUSION: Even though these results are promising, future EQAs have to be closely monitored to ensure this positive trend is not just a snapshot.


Asunto(s)
Epitelio/inmunología , Hipersensibilidad/diagnóstico , Inmunoglobulina E/sangre , Juego de Reactivos para Diagnóstico/normas , Contaminación del Aire Interior/efectos adversos , Animales , Gatos/inmunología , Conjuntos de Datos como Asunto , Dermatophagoides farinae/inmunología , Dermatophagoides pteronyssinus/inmunología , Humanos , Variaciones Dependientes del Observador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA